CATALOG # TYPE JOB NAME WATTAGE VOLTAGE Lighting Since 1895 SmartLED™ MRI Lighting Systems MRP-22290 2’ x 2’ Scenic Panel Luminaire Ultra-slim 20W LED Illuminated Artwork Use Multiple Luminaires to Create a Soothing and Attractive “SkyLight” Effect Specifications Luminaire Features • Driverless, 20 watt, low voltage, Class II, DC powered. • Must use in conjunction with SmartSupply™ LPS-0700A. • Ultra-thin (2”) extruded aluminum housing. White finish; for custom color see Option -94. • Completely non-ferro magnetic. Thermal Management • Housing / heat sink provides maximum heat dissipation for side-fire LED technology. SmartSupply™ (Remote Power Supply) Required - Order Separately • LPS-0700A: Digitally controlled. Drives up to 12 scenic panels. Maximum 100 ft. distance. • 100-0.2% full range dimming in up to 4 zones. • Compatible with 0-10V DC dimming controls. See vendor qualified list in the owner’s manual. • Suitable for dry, non-plenum locations only with ambient temperature range of -20°C (-4°F) to 40°C (104°F). 115 - 277V isolated circuit only; maximum 290V; 50-60 Hz. • For more information, see specification sheet for LPS-0700A. SmartFilter™ (RFI / EMI Filter) Required - Order Separately • RFI-3100D: Protects up to 3 luminaires (SmartSupply channels). • Provides 100 db of RF signal attenuation, matching the most stringent MRI requirements. • For more information see specification sheet for RFI-3100D. SmartPower™ Battery Backup • EMI-21220 for emergency power. • See specification sheet; order separately. Trim / Lens • Regressed trim provides a unique, architectural “skylight” effect when installed in grid ceiling. • Extruded acrylic, wave guide lens provides unparalleled uniformity and even illumination of the image. See specification sheet; order separately. Installation • Requires minimum 18 AWG twisted pair shielded wire from SmartSupply™ to fixtures. • Drops into 2’ x 2’ ceiling grid. Use With: •SmartSupply™ LPS-0700A •SmartFilter™ RFI-3100D Use of SmartSupply™ and SmartFilter™ REQUIRED or Kirlin warranty is null and void UL, C-UL (Canada) Listings • Wet, damp, dry locations, covered ceilings. • Type IC for direct contact with insulation. CE & FCC Compliance • Meets IEC/EN 60601-1-2 electromagnetic compatibility standard for medical electrical equipment. • FCC Part 15 certified for EMI/RFI emissions. FIVE YEAR Limited Warranty • Complete standard fixture. Dimensions 23¾” Sq. [603mm] Luminaire is available in nominal 2’ x 2’ size only. Specify a scenic array as large as required. See following pages for complete ordering & configuration information. SmartLED MRI MAY 2016 3401 EAST JEFFERSON AVENUE • DETROIT, MICHIGAN 48207-4232 (313) 259-6400 • Fax: (313) 259-9409 OR (313) 259-3121 • www.kirlinlighting.com SmartLED™ MRI Lighting Systems Luminaires • SmartSupply • SmartFilter DUE TO OUR CONTINUING EFFORT TO IMPROVE PRODUCTS, TECHNICAL INFORMATION IS SUBJECT TO CHANGE WITHOUT NOTICE. THE KIRLIN COMPANY EXPECTS PHOTOMETRIC PERFORMANCE TO IMPROVE SIGNIFICANTLY AND FREQUENTLY AS LED SOURCE TECHNOLOGY IMPROVES. CATALOG NUMBER MRP-22290 SmartLED™ MRI Lighting Systems Since 1895 MRP-22290 2’ x 2’ SCENIC PANEL 20 WATT Step 1: Select Size and Artwork Orientation • Specify overall size (panel quantity) and orientation using Size Option added to base catalog number MRP-22290 • See Product Numbering Guide below When specifying size, orientation and artwork, consider how the image will be divided and cropped. For example: Overall Size and Orientation Landscape Nominal Dimensions Fixture Qty. Arrangement Option Portrait Preferred Resolution (Pixels) 2’ x 2’ 1 -2x2 1800 x 1800 2’ x 4’ 2 -4x2 3600 x 1800 4’ x 4’ 4 -4x4 3600 x 3600 4’ x 6’ 6 -6x4 5400 x 3600 6’ x 6’ 9 -6x6 5400 x 5400 6’ x 8’ 12 -8x6 7200 x 5400 8’ x 8’ 16 -8x8 7200 x 7200 Arrangement Option Preferred Resolution (Pixels) -2x4 1800 x 3600 -4x4 -4x6 3600 x 5400 -6x4 -6x8 5400 x 7200 -4x6 Custom Size To see how your artwork will appear in an arrangement, consult factory. -9x9 Specify number of panels and orientation of artwork Product Numbering Guide M R P - 2 2 2 9 0 - 4 x 6 - A 0 1 - 9 4 Example: Scenic Panel Base Product Number Custom Color Trim Option Size and Orientation Option* Artwork Option *-4x6 is not the same as -6x4, see above. SmartLED™ MRI Lighting Systems Since 1895 Step 2: Select Artwork 2’ x 2’ SCENIC PANEL MRP-22290 20 WATT Add Artwork Option Code to Catalog Number -A01 -A02 -A03 -A04 -A05 -A06 Artwork Selection Continued Next Page Step 2: Select Artwork - continued Add Artwork Option to Catalog Number QUALIFIED ARRA JOB NAME TYPE APPROVAL STAMP SUBMITTAL DATA 1800 x 1800 pixels (or greater) per 24” x 24” panel See “Overall Size and Orientation” table on page 2 for preferred image resolution for each configuration -A99 Step 3: Select Additional Options -94 Custom color trim. Consult factory. -99 Special modification. Consult factory. -BG Anti-microbial Kirlin BioGard™ white (only) frame finish. 3. Use a 0-10V wall box dimmer that is approved for use with SmartSupply™ (consult Owner’s Manual); wall dimmers must be located outside of room shield and must not be filtered through RFI-3100D SmartFilter™ SmartLED MRI FEBRUARY MAY 2016 2015 LIMITED WARRANTY: CATALOGED KIRLIN FIXTURES ARE WARRANTIED FREE OF DEFECTS IN WORKMANSHIP OR MATERIAL FOR THREE YEARS FROM DATE OF PURCHASE, INSTALLED TO N.E.C., IN NORMAL USE. Manufacturer at his option will replace or repair such fixture or refund the purchase price on presentation of proof of purchase and defective fixture at the offices of manufacturer within three years of original shipment. Liability of manufacturer is limited to the foregoing, and manufacturer shall not be liable for any other damages, direct or indirect, sustained or suffered by purchaser or any person. This warranty is supplied to the buyer in place of all other warranties, expressed or implied. Seller does not warrant as to merchantability or fitness for a particular use, nor will any oral statement constitute a warranty or amend this specific warranty. Abnormal use, abuse of the fixture, improper installation, or repair, or modification of the fixture without prior written authorization from the manufacturer will render the warranty void. CATALOG NUMBER VOLTAGE WATTAGE 2. Use a minimum #18 AWG twisted, shielded pair wire “Artifact-Free” Imaging 1. Use complete Kirlin SmartLED™ MRI system: luminaires, filters, drivers 3 Steps To Custom Artwork Preferred Image Resolution Custom Image Consult Factory 20 WATT SCENIC PANEL 2’ x 2’ MRP-22290 Since 1895 SmartLED™ MRI Lighting Systems