PARTITION LEGEND
5.
6.
7.
9.
10.
WHERE THE FACE OF AN EXISTING PARTITION OR COLUMN MEETS FLUSH WITH A NEW PARTITION, REMOVE THE EXISTING
METAL CORNER BEAD BEFORE INSTALLING THE NEW PARTITION.
ALIGN THE NEW PARTITION SURFACES WITH THE EXISTING ADJACENT OR ADJOINING SURFACES WHERE INDICATED. TAPE
AND SAND SMOOTH WITHOUT ANY VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING
SURFACES.
CONTRACTOR SHALL NOTIFY ARCHITECT A MINIMUM OF THREE (3) BUSINESS DAYS BEFORE CLOSING WALLS SO THAT
REVIEWS AS REQUIRED BY THE ARCHITECT MAY TAKE PLACE.
12.
PATCH AND REPAIR EXISTING DAMAGED FIREPROOFING WORK AS REQUIRED BEFORE CONCEALING.
13.
PROVIDE FIRE EXTINGUISHERS AS NOTED, AND AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR.
14.
PROVIDE A CLEAR HORIZONTAL DIMENSION OF 1'-6" MINIMUM FROM STRIKE FACE OF DOOR JAMB TO THE NEAREST RETURNING
PARTITION OR OBSTACLE AT THE PULL SIDE OF THE DOOR. AT THE HINGE SIDE LOCATE THE DOOR JAMB SO THAT ITS FACE IS
4" FROM THE NEAREST PARTITION AND LOCATE THE DOOR STOP TO ALLOW FOR A MINIMUM 90 DEGREE SWING.
2.
3.
REFER TO THE ELECTRICAL DESIGN-BUILD DRAWINGS FOR:
A. CIRCUITING AND WIRING OF LIGHT FIXTURES AND SWITCHES.
B. LIFE SAFETY EQUIPMENT
C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURE.
D. LIGHT FIXTURE TYPES AND SPECIFICATIONS.
E. SMOKE DETECTORS
F. SWITCH TYPE.
REFER TO THE MECHANICAL DESIGN-BUILD DRAWINGS FOR:
A. DUCTS, AIR MOVEMENT REQUIREMENTS, AND SIZES OF GRILLES AND REGISTERS.
B. THERMOSTATS
C. EXHAUST FANS, AIR SUPPLY, RETURN REGISTERS.
A3
TYPE A3: NON-RATED ACOUS. DEMISING PARTITION FROM TOP OF SLAB TO UNDERSIDE OF CONCRETE DECK (4 7/8" THK)
WITH ONE LAYER OF 5/8" GYP. BD. ON TENANT SIDE
DENOTES TO BE DETERMINED
20.
CONCEALED WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED, TYPICAL.
21.
VERIFY DIMENSIONS SHOWN WITH FIELD MEASUREMENTS. CHECK LEVELS AND LINES INDICATED BEFORE COMMENCING
WORK. ARCHITECT SHOULD BE NOTIFIED OF ANY DISCREPANCIES FOR ADJUSTMENT OR CORRECTION. WORK SHALL
PROCEED ONLY AFTER THE DISCREPANCY HAS BEEN RESOLVED.
F1
VCT
1
TYPE F1: NON-RATED, FURRED, PARTITION FROM TOP OF SLAB TO 6" ABOVE SUSPENDED CEILING (3 1/8" THK)
E
F.E.C.
1i
XX
2
(E) SUITE
ENTRANCE
DENOTES DOOR TYPE - REFERENCE SHEET A9.2
DENOTES DOOR HARDWARE GROUP
( "E/E" DENOTES EXISTING DOOR TYPE AND HARDWARE)
WHERE CONFLICTS OCCUR, THE CONTRACTOR SHALL COORDINATE THE LAYOUT AND EXACT LOCATION OF PARTITIONS,
DOORS, TELEPHONE, ELECTRICAL & COMMUNICATIONS OUTLETS AND SWITCHES WITH THE ARCHITECT IN THE FIELD BEFORE
PROCEEDING WITH CONSTRUCTION.
PROVIDE FIRE SAFING IN UNUSED SLEEVES & WITHIN VOIDS AROUND CONDUIT, PIPES, & CABLING IN SLEEVES.
BRACE NEW PARTITIONS, BOOK SHELVING, LIGHT FIXTURES, CEILING SYSTEMS, AS PER STATE & LOCAL SEISMIC CODES. IF
EXISTING COMPONENTS ARE NOT BRACED AS PER LATEST CODE REQUIREMENTS, CONTRACTOR SHALL BE RESPONSIBLE
FOR SUCH WORK AS REQUIRED.
26.
CONTRACTOR TO ENSURE THAT THERE IS A MINIMUM CLEAR WIDTH OF 44" IN AISLES LEADING TO REQUIRED CORRIDORS AND
EXITS.
27.
NO WORK IS TO BE DONE IN AREAS MARKED "N.I.C.", U.O.N.
28.
INTERIOR FINISHES COMPLY WITH THE ALLOWABLE COMBUSTIBLE MATERIAL LIST AND INSTALLATION PER SECTION 603 OF THE
CBC. INTERIOR WALL FINISHES COMPLY WITH CLASSIFICATIONS LISTED ON TABLE 803.5 OF THE CBC FOR FLAME SPREAD AND
SMOKE-DEVELOPED INDEXES.
5.
REFER TO THE FIRE PROTECTION (DESIGN BUILD) DRAWINGS FOR:
A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER LINES AND HEADS.
B. PRESSURE REQUIREMENTS.
C. SPRINKLER HEAD SPECIFICATIONS.
29.
ALL PORTIONS OF THE BUILDING SHALL BE WITHIN 75 FEET OF A FIRE EXTINGUISHER. THE MINIMUM SIZE OF THE
EXTINGUISHER SHALL BE 2-A:10-BC. PER CFC 906.
13.
REFER TO FIRE ALARM DRAWINGS FOR ADDITIONAL INFORMATION. STROBES AND ALARMS TO CONFIRM TO TITLE 24 AND ADA STANDARDS.
14.
LICENSED FIRE ALARM CONTRACTOR SHALL SUBMIT (3) SETS OF DRAWINGS, EQUIPMENT CUT SHEETS, BATTERY CALCULATIONS, VOLTAGE
DROP CALCULATION, ETC. TO THE FIRE DEPT. FOR REVIEW AND PERMIT.
15.
LICENSED FIRE PROTECTION CONTRACTOR SHALL SUBMIT (3) SETS OF SPRINKLER DRAWINGS FOR REVIEW AND PERMIT.
16.
INSTALL SPRINKLER HEADS AND LIGHT FIXTURES AT CENTER OF ACOUSTICAL UNIT, UON.
17.
PROVIDE EXIT SIGNS AND EMERGENCY LIGHT FIXTURES AS DIRECTED BY THE FIRE MARSHALL AND AS SHOWN ON DRAWINGS. EXIT SIGNS TO
BE MINIMUM 6" HIGH BY 3/4" STROKE BLOCK LETTERS ON A CONTRASTING BACKGROUND. SPACING BETWEEN SIGNS SHALL NOT EXCEED 100
FEET. WHENEVER THE BUILDING IS OCCUPIED, EXIT SIGNS SHALL BE LIGHTED SO THAT THEY ARE CLEARLY VISIBLE.
18.
SWITCHES CONTROL LIGHTS IN THE ROOM WHERE THEY ARE LOCATED, UNLESS OTHERWISE NOTED.
19.
AT LOCATIONS WITH MORE THAN (1) SWITCH, GANG AND FINISH SWITCHES WITH (1) COVERPLATE.
20.
WIRE FLUORESCENT LIGHT FIXTURES FOR DOUBLE SWITCHING AND LOCATE AS REQUIRED BY CODE.
21.
PROVIDE SWITCHES AND COVERPLATES AS FOLLOWS: WHITE, UNLESS OTHERWISE NOTED.
REFLECTED CEILING PLAN - LEGEND
6.
REFER TO DETAILS 1,2,3,4, & 7/A9.4 FOR SUSPENDED CEILING BRACING.
7.
SUSPENDED CEILING GRID TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12'-0". ANCHOR AS REQUIRED.
8.
INSTALL PERIMETER CEILING ANGLE TIGHT TO PARTITION, FREE FROM CURVES, BREAKS & OTHER IRREGULARITIES.
9.
CUT ACOUSTICAL UNITS WITH SHARP AND NEAT EDGES. AVOID INSTALLING CUT ACOUSTICAL UNITS NARROWER THAN HALF
THE ORIGINAL WIDTH OF THE UNIT, UON.
10. COORDINATE WITH OTHER TRADES TO ENSURE THAT CLEARANCES FOR ELECTRICAL, HVAC, FIRE PROTECTION,
COMMUNICATIONS, LIGHTING, PLUMBING, SPRINKLER EQUIPMENT AND OTHER WORK ADJACENT TO CEILING, ARE CORRECT
FOR THE CEILING HEIGHT INDICATED, AND THAT THE REQUIRED CLEARANCES FOR INSTALLATION OF AND MAINTENANCE OF
THE EQUIPMENT ARE MAINTAINED. CLARIFY AND RESOLVE CONFLICTS WITH ARCHITECT.
A2
A
1
22.
RUN NEW BUILDING'S SYSTEM CABLING, DUCTWORK, SPRINKLERS AND CONDUIT, PARALLEL TO BUILDING'S GRID.
23.
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY CONFLICTING CONDITIONS PRIOR TO AND DURING CONSTRUCTION.
24.
EXIT SIGNS SHALL BE ADDED OR RELOCATED AT THE DIRECTION OF THE BUILDING OR FIRE DEPARTMENT INSPECTORS.
25.
INTERIOR FINISHES WILL COMPLY WITH THE ALLOWABLE COMBUSTIBLE MATERIAL LIST AND INSTALLATION PER SECTION 603 OF THE CBC.
INTERIOR CEILING FINISHES COMPLY WITH CLASSIFICATIONS LISTED ON TABLE 803.5 OF THE CBC FOR FLAME SPREAD AND SMOKEDEVELOPED INDEXES.
26.
COFFEE/
WORK RM
302
CEILING TYPES
F1
15' - 4"
A4
1718 Third Street, Suite 101
Sacramento, CA 95811
B
2
A
2
5
BL
1
2
OPEN
OFFICE
301
B
2
CONFERENCE
RM
304
Tel 916.449.1400
Fax 916.449.1414
www.rmw.com
3
TYP.
1
4
+64"
+64" +64"
7
1/8" = 1'-0"
F1
1
LIGHT FIXTURE TYPES
NEW 2'x4' SUSPENDED ACCOUSTICAL CLG
MFR : ARMSTRONG
TILE : DUNE TEGULAR, 24" x 48" x 3/4"
GRID : PRELUDE 15/16"
2x2 LAY-IN 18 CELL PARABOLIC
FLUORESCENT LIGHT FIXTURE
SPEC: BUILDING STANDARD
(E) DENOTES EXISTING
(R) DENOTES RELOCATE
(N) DENOTES NEW
(D) DENOTES DEMOLISH/REMOVE
4"
ALIGN
2x4 LAY-IN 18 CELL PARABOLIC
FLUORESCENT LIGHT FIXTURE
SPEC: BUILDING STANDARD
5
ISOLITE, SINGLE SIDED,
WALL-MOUNTED EXIT SIGN
GYP. BD. CEILING
ISOLITE, DOUBLE SIDED,
CEILING MOUNTED EXIT SIGN
X'-X" A.F.F.
7
PARTITION/ POWER & SIGNAL/ FINISH PLAN - FLOOR 3
CEILING HEIGHT ABOVE FINISHED FLOOR
VANTAGE POINT MEDIA
COFFEE/
WORK RM
302
CLOSET
303
2020 L STREET, 3RD FLOOR
SACRAMENTO, CA
TWO-WAY
10'-0" A.F.F.
NON-DIRECTIONAL
PREPARE AND SUBMIT THE FOLLOWING DRAWINGS TO THE ARCHITECT FOR REVIEW PRIOR TO ORDER OR FABRICATION OF
MATERIALS AND/OR INSTALLATION OF SYSTEM:
A. HVAC DRAWINGS
C. ELECTRICAL DRAWINGS
B. SPRINKLER DIAGRAMS
D. PLUMBING DRAWINGS
B
2
1
CLOSET
303
A3
C
1
E
ONE-WAY
4.
4
+44" D.W.
+44"
3
3 A9.2
2
+44" 11' - 11"
G.D. 1
2' - 11"
A2
ALIGN
COORDINATE LOCATIONS OF MECHANICAL, ELECTRICAL, TELEPHONE, LIGHTING, PLUMBING AND SPRINKLER INCLUDING PIPING,
DUCTWORK AND CONDUIT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION TO ASSURE THAT REQUIRED
CLEARANCES FOR INSTALLATION AND MAINTENANCE OF THE ABOVE EQUIPMENT IS PROVIDED.
25.
3' - 0"
3' - 11"
PROVIDE THE REQUIRED BACKING, BRACING, AND BLOCKING FOR ATTACHMENT OF CABINETWORK, EQUIPMENT, AND OTHER
WORK.
REFER TO THE REFLECTED CEILING PLAN SHEETS FOR THE LOCATION OF:
A. LIGHT FIXTURES BY TYPE
B. EXIT SIGNS
T.B.D.
FIRE EXTINGUISHER CABINET
24.
REFLECTED CEILING PLAN NOTES
1.
DENOTES EXISTING TO REMAIN
NOT IN CONTRACT
23.
CUT AND FIT COMPONENTS AS REQUIRED TO ALTER EXISTING WORK FOR INSTALLATION OF NEW WORK. PATCH DAMAGED
AREAS TO MATCH ADJACENT MATERIALS AND FINISHES.
(E)
INTERIOR OPEN JOINTS, PENETRATIONS AND OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED,
GASKETED AND WEATHER-STRIPPED TO LIMIT AIR LEAKAGE. PENETRATIONS AT RATED PARTITIONS SHALL BE FIRE SAFE TO
MAINTAIN RATING.
22.
THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AFTER WALL LOCATIONS HAVE BEEN MARKED ON THE FLOOR. THE
ARCHITECT SHALL REVIEW THE WALL LOCATION LAYOUT BEFORE THE CONTRACTOR PROCEEDS WITH WALL CONSTRUCTION.
PATCH AND REPAIR EXISTING PARTITION SURFACES AS REQUIRED FOR A SMOOTH FINISHED WORK.
15
19.
WHERE NEW PARTITIONS MEET INTERIOR OR EXTERIOR MULLIONS (OR COLUMNS), INSTALL THE NEW PARTITION CENTERED
ON THE MULLIONS (OR COLUMNS) AND PERPENDICULAR TO IT.
11.
THE EXISTING ENTRANCE DOORS, STAIRWAYS, AND ELEVATORS LEADING TO THIS AREA OF REMODEL COMPLY WITH THE
HANDICAP ACCESS REQUIREMENTS. INSPECTOR TO VERIFY.
TYPE A2: NON-RATED ACOUS. PARTITION FROM TOP OF SLAB TO UNDERSIDE OF CONCRETE DECK (4 7/8" THK)
FEC
8.
18.
DENOTES NEW
1' - 6"
WHERE NEW PARTITIONS MEET EXISTING (EXTERIOR OR INTERIOR), INSTALL THE NEW PARTITIONS PERPENDICULAR TO THE
EXISTING.
(N)
12' - 5"
4.
A2
EXISTING WALL TO REMAIN
CC
UNLESS OTHERWISE INDICATED, INSTALL PARTITIONS PARALLEL TO THE STRUCTURAL GRID OF THE BUILDING.
DIMENSIONS ON THIS SHEET ARE FROM FACE OF FINISHED SURFACE TO FACE OF FINISHED SURFACE, U.O.N.
TYPE A1: NON-RATED ACOUS. PARTITION FROM TOP OF SLAB TO 6" ABOVE SUSPENDED CEILING (4 7/8" THK)
2' - 0"
3.
17.
A1
1' - 2 1/2"
REFER TO DETAILS 1 & 2/A9.1 FOR TYPICAL PARTITION BRACING.
NEW TENANT IMPROVEMENT CONSTRUCTION
INSTALL TEMPERED GLASS WITH MANUFACTURER'S SEAL LOCATED IN THE LOWER CORNER OF THE GLAZED PANEL.
CONCEAL TONG MARKS, IF ANY. GLAZING SHALL CONFORM TO FEDERAL REGULATIONS & CHAPTER 24 OF CALIFORNIA
BUILDING CODE.
CLR
2.
16.
4' - 11"
ERECT TYPE "A1" PARTITIONS, UNLESS OTHERWISE NOTED. FIRMLY ANCHOR & BRACE PARTITIONS PER CODE AND DETAILS.
REFER TO SHEET A9.1 FOR TYPICAL PARTITION DETAILS.
5' - 4"
1.
PARTITION TYPES
CC
PARTITION PLAN NOTES
TYP.
6
4
NIC
approved for the owner by :
OPEN
OFFICE
301
CONFERENCE
RM
304
approved for the architect by :
ISSUE :
AT ANY TIME THE BUILDING IS OCCUPIED, THE MEANS OF EGRESS SHALL BE ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOTCANDLE AT WALKING SURFACE LEVEL PER CBC 1006.1.
27.
ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM THAT WILL PROVIDE POWER FOR NOT LESS THAN 90
MINUTES PER CBC 1006.3.
28.
PER CMC 609 & NFPA 90A: EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING AIR IN EXCESS OF 2,000 CFM SHALL BE EQUIPIPED WITH
AN AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS. DECT DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM SYSTEM.
29.
THE PLANS SHALL COMPLY WITH CBC 1117B.5.1 NO. 1.
Approver
REVISIONS :
1
REFLECTED CEILING PLAN - FLOOR 3
1/8" = 1'-0"
#
Description:
Date:
ISSUE FOR BID
TENANT REVISIONS
2
11/23/10
12/07/10
11. VERIFY REQUIREMENTS FOR LIFE SAFETY SYSTEMS (I.E. SMOKE DETECTORS, ALARMS, EARLY WARNING SYSTEMS ETC.) WITH
FIRE INSPECTOR AND/OR FIRE MARSHALL. COORDINATE REQUIREMENTS WITH ARCHITECT PRIOR TO INSTALLATION.
12. ALIGN WALL MOUNTED ITEMS IN CLOSE PROXIMITY (E.G., STROBES LIGHT SWITCHES, THERMOSTATS) VERTICALLY. REFER TO
DETAIL 1/A9.3 FOR MOUNTING HEIGHTS.
LEED COMPLIANCE NOTES
FINISH LEGEND
FLOOR FINISHES
1.
NO WORK TO BE DONE IN AREAS MARKED "N.I.C.", U.O.N.
17.
REMOVE FOREIGN PAINT AND DIRT FROM WINDOW TRIM, SILL, AND HEAD.
REFER TO "LEED REFERENCE GUIDE FOR GREEN INTERIOR DESIGN AND CONSTRUCTION" FOR ADDITIONAL INFORMATION
2.
UNLESS OTHERWISE NOTED, ROOM FINISHES SHALL BE:
18.
PAINT (PARTITIONS, WALLS, EXISTING PARTITIONS, etc.) WITH PRIME COAT P.V.A. SEALER AND TWO FINISH COATS OF
LATEX, LIGHT STIPPLE. U.O.N., PROVIDE LEVEL 4 FINISH.
1.
P-1
CEILING SOFFITS
BUILDING STD FIN.
MATCH (E) AT EXIT HALL
THE FINISH PLANS INDICATE THE TYPES AND EXTENTS OF FINISHES. REFER TO THE PROJECT & MANUFACTURERS' MANUALS
FOR ADDITIONAL INFORMATION AND INSTALLATION.
19.
PAINT FIRE EXTINGUISHER CABINETS WITH (2) COATS OF SEMI-GLOSS PAINT TO MATCH ADJACENT PARTITION.
20.
PAINT ACCESS PANELS AND BOXES TO MATCH ADJACENT WALL/CEILING SURFACES, U.O.N.
21.
GYPSUM BOARD CEILINGS TO BE PAINTED FLAT FINISH, U.O.N.
4.
PATCH AND REPAIR AREAS AFFECTED BY DEMOLITION. FINISH TO MATCH ADJACENT SURFACES, U.O.N.
22.
PLASTIC LAMINATE MILLWORK SHALL BE PER A.W.I. STANDARDS FOR CUSTOM GRADE FABRICATION.
5.
MILLWORK FINISHES SHALL BE PLASTIC LAMINATE, UNLESS OTHERWISE NOTED. OPEN CABINETS SHALL BE PLASTIC
LAMINATE; CABINET INTERIORS SHALL BE WHITE MELAMINE, U.O.N. (SUBMIT SAMPLE).
23.
SUBMIT THE FOLLOWING FOR THE ARCHITECT'S REVIEW PRIOR TO ORDER OR FABRICATION.
6.
FINISH DOORS SIX SIDES TYP.
7.
FLOOR SLAB SHALL BE LEVELED AS REQUIRED FOR INSTALLATION OF SCHEDULED FLOOR COVERINGS.
A)
B)
C)
D)
E)
F)
G)
(3) 5" LONG SAMPLES OF BASE TO BE USED
(3) CARPET SEAMING DIAGRAM.
(3) 8 1/2" X 11" BRUSH OUT SAMPLES OF PAINT COLORS.
(3) 5" X 7" SAMPLES OF CARPET.
(3) 3" X 3" SAMPLES OF VCT.
SAMPLES OF ANY OTHER FINISH MATERIALS
MILLWORK SHOP DRAWINGS PER INDUSTRY STANDARDS & REQUIREMENTS.
8.
CENTER THE TRANSITION OF FLOORS OCCURRING IN DOOR OPENINGS UNDER THE CENTER OF THE DOOR IN THE CLOSED
POSITION, U.O.N.
9.
WHERE FLOOR MATERIAL TRANSITION OCCURS AT CASED OPENING, TRANSITION IS TO OCCUR AT INSIDE OF FACE OF
OPENING, U.O.N.
24.
10.
PROVIDE VINYL REDUCER STRIP WHERE DISSIMILAR FLOOR SURFACES MEET COLOR TO MATCH RUBBER BASE IN ROOM,
U.O.N.
25.
DO NOT SCALE THE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR SITE REVIEW AND VERIFICATION OF
QUANTITIES OF MATERIALS REQUIRED TO COMPLETE THE INSTALLATION.
11.
ALIGN JOINTS IN TILES (CERAMIC and/or RESILIENT) WHERE PARTITIONS AND FLOORS MEET. U.O.N.
26.
CLEANING AND RETOUCHING:
12.
CENTER THE (CARPET, CERAMIC, etc.) TILES IN THE ROOMS WITH NO TILES AT THE ROOM PERIMETER LESS THAN HALF THE
WIDTH OF THE TILE, U.O.N
13.
LAY CARPET IN THE SAME DIRECTION IN OPEN AREAS. PATTERN DEVIATION (SKEW) SHALL NOT EXCEED 1/4" IN 12'-0" AFTER
INSTALLATION.
14.
FABRICATE CARPET FROM A SINGLE DYE LOT.
15.
INSTALL STRAIGHT RESILIENT BASE WHERE CARPETED AREAS AND COVE BASE AT VCT FLOORING, U.O.N.
16.
RESILIENT BASE SHALL BE FROM A CONTINUOUS ROLL.
2.
ALL PAINTS AND COATINGS MUST NOT EXCEED VOC LIMITS ESTABLISHED IN SCAQMD RULE 1113. ANTI-CORROSIVE
AND ANTI-RUST PAINTS MUST NOT EXCEED VOC CONTENT OF 250g/L. CLEAR WOOD FINISHES, FLOOR COATINGS,
STAINS, PRIMERS, AND SHELLACS MUST NOT EXCEED VOC LIMITS ESTABLISHED IN SCAQMD RULE 1113.
3.
ALL CARPET INSTALLED MUST MEET REQUIREMENTS OF CARPET AND RUG INSTITUTE (CRI) GREEN LABEL PLUS
PROGRAM. ALL CARPET CUSHION INSTALLED MUST MEET REQUIRMENTS OF CRI GREEN LABE PROGRAM. CARPET
ADHESIVES MUST HAVE LESS THAN 50g/L VOC. ALL HARD SURFACE FLOORING MUST BE CERTIFIED AS COMPLIANT
WITH THE FLOORSCORE STANDARD. CONCRETE SEALER MUST MEET THE REQUIREMENTS OF SCAQMD RULE 1113.
TILE SETTING ADHESIVES AND GROUT MUST MEET REQUIREMENTS OF SCAQMD RULE 1168.
4.
ALL COMPOSITE WOOD AND AGRIFIBER PRODUCTS USED ON THE INTERIOR OF THE BUILDING MUST CONTAIN NO
ADDED UREA-FORMALDEHYDE RESINS.
28.
4. REFER TO THE MECHANICAL DESIGN-BUILD DRAWINGS FOR MECHANICAL EQUIPMENT REQUIREMENTS.
5. MOUNT TELEPHONE, DATA, AND ELECTRICAL OUTLETS VERTICALLY, UNLESS OTHERWISE NOTED.
POWER & SIGNAL LEGEND
FLOOR MONUMENT RECEPTACLE
18. TELEPHONE AND COMMUNICATION OUTLETS SHALL BE FURNISHED WITH TRIM RING IN WALL
AND A PULL STRING THROUGH THE WALL TO THE CEILING PLENUM OR THE NEAREST READILY ACCESSIBLE LOCATION,
ONE PULL STRING PER CONNECTION PORT. TENANT'S VENDOR TO PROVIDE & INSTALL RECEPTACLE & COVER PLATE.
FLOOR FLUSH MOUNTED RECEPTACLE
19. PROVIDE TELEPHONE AND COMMUNICATION CABLES THAT MAY BE USED IN CEILING PLENUMS WITHOUT CONDUITS.
MONOPLEX POWER
20. EXPOSED VOICE/DATA CABLES RUNNING IN CEILING PLENUM ARE REQUIRED TO BE PLENUM RATED.
DUPLEX POWER
21. NOT USED
FOURPLEX POWER
PL
2
PLASTIC LAMINATE ( COUNTER TOP)
TBD
MFR:
TBD
NO:
TBD
COLOR:
SYMBOL ATTRIBUTE
NEW
2
DISHWASHER (CONTRACTOR FURNISHED)
(D)
DEMOLISH
3
REFRIGERATOR (TENANT FURNISHED)
(E)
EXISTING TO REMAIN
4
FLAT SCREEN TV (TENANT FURNISHED) - WALL MOUNTED. PROVIDE BACKING
AS REQUIRED
(R)
RELOCATE
5
FLAT SCREEN TV (TENANT FURNISHED) MOUNTED ON STAND
C
EXISTING TO BE CAPPED
IG
ISOLATED GROUND
3
TENANT PROVIDED FURNITURE SHOWN FOR REFERENCE ONLY
4
PROVIDE (N) GYP. BD. CEILING AT (N) SUITE ENTRANCE; HEIGHT & FINISH TO MATCH
ADJACENT (E) CEILING AT EXIT HALLWAY. INSTALL (N) BLDG STD DOWNLIGHT,
CENTERED IN ALCOVE
7
ACCESS POINT FOR WIRELESS HIGH SPEED INTERNET; COORDINATE WITH TENANT
FOR EXACT LOCATION, MOUNTING HEIGHT, & WIRING REQUIREMENTS
26. IMMEDIATELY NOTIFY ARCHITECT OF CONFLICTING CONDITIONS PRIOR AND DURING CONSTRUCTION.
PROCEED WITH WORK ONLY AFTER THE DISCREPANCIES HAVE BEEN RESOLVED.
(2) TELEPHONE & (2) DATA
MONOPLEX DATA
TELEPHONE / DATA
drawn by :
JT
plot date : 12/7/2010
3:55:03 PM
checked by : MA
stamp :
scale :
project number :
SED ARCH I T
N
E
STEPHEN D.
GUEST
NO. C12502
REN.10-31-11
TE
A
DEDICATED FOURPLEX POWER
9. HORIZONTAL DIMENSIONS SHOWN ARE FROM/TO THE MIDPOINT OF A GROUP OF ADJACENT OUTLETS
OR THE MIDPOINT OF A SINGLE OUTLET. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION
BETWEEN EACH DEVICE.
29. PREPARE AND SUBMIT REQUIRED DOCUMENTS TO THE (ARCHITECT, OWNER,
AND/OR APPROPRIATE GOVERNMENT AGENCY) SUBSTANTIATING COMPLIANCE
WITH C.A.C. TITLE 24 ENERGY REQUIREMENTS.
REUSE (E) DOOR, FRAME, & SIDELITE ASSEMBLY AT (N) SUITE ENTRANCE; REMOVE &
RELOCATE UPON DEMOLITION OF (E) SUITE ENTRANCE
(E) GYP. BD. CEILING & LIGHTING TO REMAIN
DUPLEX TELEPHONE
12. PROVIDE GROMMETS IN WORKSURFACES DIRECTLY OVER DEVICES SHOWN ON PLAN. COORDINATE LOCATIONS WITH ARCHITECT.
2
6
25. ELECTRICAL EQUIPMENT SHALL BE INSTALLED TO COMPLY WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS.
O
OF CA L I F
R
As indicated
23470.21
JUNCTION BOX FOR POWER
J
J
PROVIDE FIRE RESISTANT PLYWOOD BACKBOARD FOR TELEPHONE PANEL;
COORDINATE EXACT LOCATION & SIZE WITH TENANT
DEDICATED DUPLEX POWER
8. GANG DEVICES SHOWN ADJACENT WITH A SINGLE COVER PLATE WHERE POSSIBLE.
J
1
DEMOLISH (E) GYP. BD. CEILING AT (E) SUITE ENTRANCE
7. MOUNT UNDIMENSIONED OUTLETS WITHIN 12" HORIZONTALLY FROM THE LOCATION SHOWN.
28. WIRE EXIT SIGNS AND LIGHT FIXTURES WITH 2 SEPARATE CIRCUITS. TIE TO (E) BUILDING EMERGENCY CIRCUITS.
BUILDING STANDARD ADA COMPLIANT SINK & FAUCET W/ GARBAGE DISPOSAL
(N)
23. FURNITURE & EQUIPMENT IS DRAWN FOR REFERENCE ONLY AND TO BE SUPPLIED BY OWNER, U.O.N.
11. OWNER'S FURNITURE VENDOR TO VERIFY LOCATIONS OF FLOOR MONUMENTS FOR SYSTEMS FURNITURE PRIOR TO CORING.
1
KEYNOTES
5
22. TELEPHONE/DATA CABLES TO BE TIED INDEPENDENTLY TO STRUCTURE PER CODE.
MONOPLEX TELEPHONE
SPECIAL 220 VOLT POWER
220v
220v
220v
CC
CC
COAXIAL CABLE
CC
14. DEDICATED OUTLETS SHALL HAVE GRAY RECEPTACLES & ISOLATED, DEDICATED OUTLETS SHALL BE ORANGE.
RED OUTLETS SHALL BE USED FOR EMERGENCY POWER ONLY.
BLANK / OPEN BOX
SP
15. FIELD VERIFY POWER AND SIGNAL FLOOR MOUNTED LOCATIONS WITH THE ARCHITECT PRIOR TO CORING.
16. NOT USED
PLASTIC LAMINATE (CABINET FRONTS)
TBD
MFR:
TBD
NO:
TBD
COLOR:
EQUIPMENT LEGEND
17. ELECTRICAL OUTLETS IN VICINITY OF WET AREAS (E.G. SINKS, LAVATORIES) SHALL BE G.F.I., TYP.
24. OWNER'S FURNITURE VENDOR TO FURNISH ELECTRICAL WHIP WHERE APPLICABLE.
GENERAL CONTRACTOR TO INSTALL.
13. WHERE OUTLETS ARE SHOWN BACK-TO-BACK, INSTALL THE OUTLETS WITH A STUD IN BETWEEN THE OUTLETS.
PL
1
IN AREAS OF OPEN/EXPOSED CEILING, PAINT ELEMENTS & CONCRETE DECK P-4.
27. REFER TO ELECTRICAL DESIGN-BUILD DRAWINGS AND FURNITURE SPECIFICATIONS
FOR WORKSTATION CIRCUITING REQUIREMENTS.
TBD
LOW VOC
TBD
EGGSHELL
CASEWORK FINISHES
INTERIOR FINISHES WILL COMPLY WITH THE ALLOWABLE COMBUSTIBLE MATERIAL LIST AND INSTALLATION PER
SECTION 603 OF THE CBC. INTERIOR CEILING FINISHES COMPLY WITH CLASSIFICATIONS LISTED ON TABLE 803.5 OF
THE CBC FOR FLAME SPREAD AND SMOKE-DEVELOPED INDEXES. FLOOR FINISHES TO COMPLY WITH CBC 804.4.1.
10. TYPICAL ELECTRICAL DUPLEX WALL OUTLETS TO BE MOUNTED AT 1'-6" AFF TO CENTERLINE TO COMPLY WITH ADA AND TITLE 24.
BUILDING STANDARD
1" ALUMINUM BLADE
BUILDING STANDARD
ST
6. WALL-MOUNTED DEVICES (POWER & SIGNAL) AT CABINETRY SHALL BE MOUNTED HORIZONTALLY, TYP.(U.O.N.)
MINI BLINDS
MFR:
STYLE:
FINISH:
T
EC
3. REFER TO 1/A9.3 FOR THE LOCATION OF THERMOSTATS, PULLBOXES, SWITCHES AND OUTLETS.
BL
1
ACCENT PAINT - CORE
MFR:
TBD
TYPE:
LOW VOC
COLOR NAME/NO: TBD
FINISH:
EGGSHELL
P
2
WALL-MOUNTED OUTLET
2. REFER TO THE ELECTRICAL DESIGN-BUILD DRAWINGS FOR:
A. WIRING AND CIRCUITING LAYOUT.
B. SWITCHING
C. PULLBOXES
D. EXPOSED CONDUIT RUNS
GENERAL PAINT
MFR:
TYPE:
COLOR NAME/NO:
FINISH:
BURKE
RUBBER
TBD
4" HIGH
COVED - HARD FLOOR SURFACES
STRAIGHT - CARPET
MISC FINISHES
WALL FINISHES
SUBMIT SAMPLES IN ACCORDANCE WITH SPECIFICATIONS OF EACH FINISH AND FLOOR COVERING TO THE ARCHITECT
FOR REVIEW PRIOR TO ORDERING.
POWER & SIGNAL PLAN NOTES
1. REFER TO THE POWER AND SIGNAL PLAN SHEETS FOR:
A. TYPE AND LOCATION OF ELECTRICAL, TELEPHONE AND DATA OUTLET, EQUIPMENT,ETC.
B. LOCATION OF PULLBOXES AND OUTLETS.
VCT
1
P
1
A)
AT COMPLETION OF PAINTING, PAINT MATERIALS AND EQUIPMENT SHALL BE REMOVED. PAINT SPOTS
REMOVED AND AREAS THOROUGHLY CLEANED. ANY DIRT OR DEBRIS CAUSED BY WORK SHALL BE CLEANED UP AS
WORK PROGRESSES.
B)
RETOUCH OR REFINISH PAINTED SURFACES DAMAGED BY SUBSEQUENT WORK AS DIRECTED BY GENERAL
CONTRACTOR. THE COST OF SUCH WORK SHALL BE BORNE BY THE TRADE RESPONSIBLE FOR THE DAMAGE.
27.
VCT - STORAGE ROOM
MFR:
ARMSTRONG
STYLE NAME:
STANDARD EXCELON
COLOR NAME:
TBD
SIZE:
12" SQUARE
RUBBER BASE
MFR:
STYLE NAME:
COLOR NAME:
SIZE:
TYPE:
IA
PARTITIONS
DOORS
RB
1
N
3.
CODE NO:
C-1
B-1
BROADLOOM CARPET
BIGELOW
MFR:
QUICKSHIP 5
STYLE:
TBD
COLOR:
12'-0" WIDE
SIZE:
DIRECT GLUE DOWN
INSTALL:
C
1
N
SURFACE
FLOOR
BASE
ALL ADHESIVES, SEALANTS, AND SEALANT PRIMERS MUST COMPLY WITH SOUTH COAST AIR QUALITY MANAGEMENT
DISTRICT (SCAQMD) RULE 1168. AEROSOL ADHESIVES MUST COMPLY WITH GREEN SEAL STANDARD FOR
COMMERCIAL ADHESIVES GS-36.
BASE FINISHES
L IC
FINISH PLAN NOTES
SP
SP
SPECIAL DEDICATED OUTLET - VERIFY SPECIFIC EQUIPMENT REQUIREMENTS
CARD READER
CR
T P
P
T
ELECTRIFIED FURNITURE PARTITION COMBINATION POWER/TELECOMMUNICATION FEEDS,
MOUNTED WITH KO'S TO ACCEPT FURNITURE WHIP.
- COORDINATE AND CONFIRM LOCATIONS, TYPE AND QUANTITY WITH FURNITURE VENDOR
FLUSH FLOOR POKE-THRU w/ FOURPLEX AND COMMUNICATION JACKS - VERIFY LOCATIONS W/
FURNITURE VENDOR
PARTITION/ POWER &
SIGNAL/ FINISH/
REFLECTED CEILING
PLAN