TRANSMITTAL 5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO 80111-4710 303-571-5377 303-629-7467 (fax) PROJECT: TO: ATTN: Ph/Fax: No. 12J2000-0027 DATE: 10/22/2012 Northwestern Mutual-West Denver Office Bldg Barker Rinker Seacat & Partnrs 3457 Ringsby Ct #200 Denver CO 80216 RE: 095100-Acoustical Ceilings Keith Hayes JOB: 303-455-1366 WE ARE SENDING: SUBMITTED FOR: 12J2000 ACTION TAKEN: Shop Drawings Approval Approved as Submitted Letter Your Use Approved as Noted Prints As Requested Returned After Loan Change Order Review and Comment Resubmit Submit Plans SENT VIA: Samples Returned Specifications / Product Data Attached Returned for Corrections Other: Separate Cover Via: Due Date: 10/29/2012 NOTES: Item Package Code Submittal 095100 095100.01 1 10/22/2012 Submittal 095100 095100.03 1 10/22/2012 Rev. Copies Date Description Status Acoustical Ceilings- ACT-1- Product Data Acoustical Ceilings- Suspension System- Product Data Architect Review CC: Signed: Brady McQuinn Architect Review Submittal Stamp Sheet Project: Northwestern Mutual- West Denver Office Building Phipps’ Job #: 12J2000 Submittal #: 095100- Acoustical Ceilings- Product Data Gerald H. Phipps, Inc.: Barker Rinker Seacat Architectur 3457 Ringsby Court, Unit #2000 Denver, CO 80216 Architect: SUBMITTED GH Phipps Construction Companies GH Phipps has reviewed, approved, and herby submits the attached in accordance with the contract documents. Note to Subcontractor/Material Supplier: Subcontractor/Material Supplier remains responsible for the confirmation and correlation of dimensions at the jobsite; fabrication processes and construction techniques; coordination of the work with the work of other trades; and satisfactory performance of the work. Engineer: Dedy Rusli 10/23/2012 Other: NOTES: Signed: Brady McQuinn- GH Phipps 095100- Prelude ML- Please advise if acceptable? OK (BRSA) NW Mutual - West Denver GH Phipps, Inc. Acoustical Ceilings Prelude XL 15/16" Grid - White October 16, 2012 CIRRUS ® Second Look ® Scored Tegular fine texture NW Mutual - West Denver GH Phipps, Inc. Acoustical Ceilings Arm - 513 Cirrus Second Look Tile October 16, 2012 Cirrus Second Look III with Suprafine ® 9/16" Exposed Tee grid Key Selection Attributes Ty p i c a l A p p l i c a t i o n s • Refined visual • Excellent sound absorption • 30-Year Limited System Warranty against mold/mildew and bacterial growth • Offices • Healthcare – assists in addressing HIPAA requirements • Conference rooms • Lobbies/reception areas • Department stores/retail Face View Photos Cirrus Second Look I – Scoring creates nominal 12" x 12" squares Detail Cirrus Second Look II – Scoring creates nominal 24" x 24" squares Cirrus Second Look III – Scoring creates nominal 6" linear plank Color White (WH) CIRRUS Second Look III CIRRUS Second Look III with SUPRAFINE 9/16" Exposed Tee grid 68% Recycled Content: CIRRUS ® Second Look ® LEED Credits Energy Scored Tegular ✔ fine texture Visual Selection armstrong.com/greengenie ® Waste Mgmt ✔ LEED for Schools Recycled Content ✔ Local Materials Renewable Materials ✔ Location Dependent Performance Selection ✔ Daylight & Views Acoustics ✔ Low Emitting or CHPS ✔ Dots represent highest level of performance. UL Classified Edge Profile Acoustics NRC CAC Fire Rating Light Reflect Class A 0.85 Item No. Dimensions 512 512M 2' x 4' x 3/4" 600 x 1200 x 19mm 0.65 9/16" Beveled Tegular 510 510M 2' x 4' x 3/4" 600 x 1200 x 19mm 0.65 15/16" Beveled Tegular 513 513M 2' x 4' x 3/4" 600 x 1200 x 19mm 0.65 9/16" Beveled Tegular 511 511M 2' x 4' x 3/4" 600 x 1200 x 19mm 0.65 15/16" Beveled Tegular 514 514M 2' x 4' x 3/4" 600 x 1200 x 19mm 0.65 Sag Resist AntiMicrobial VOC Formaldehyde Durable BioBlock+ No Added S Recycle Program CIRRUS Second Look I 15/16" Beveled Tegular 35 ● S ● ● Yes ● CIRRUS Second Look II 35 Class A ● 0.85 S ● 35 Class A ● 0.85 No Added S ● S ● ● No Added S ● ● CIRRUS Second Look III 35 Class A ● 0.85 S ● 35 Class A ● 0.85 ● No Added S ● S ● No Added ● S ● S = Standard Suspension Systems 9/16" Standard: Suprafine ® 15/16" Standard: Prelude ® Physical Data No-Added Formaldehyde No-added formaldehyde – free of formaldehyde-based resins. Outperforms CHPS Section 01350 requirements. (Independent test reports available upon request.) Material Wet-formed mineral fiber Surface Finish Factory-applied latex paint Fire Performance ASTM E84 and CAN/ULC S102 surface burning characteristics. Flame Spread Index 25 or less. Smoke Developed Index 50 or less. (UL labeled) Anti Mold/Mildew & Bacteria BioBlock ® Plus contains an anti-microbial treatment and provides guaranteed resistance against growth of mold/mildew and Gram-positive and Gram-negative odor/stain-causing bacteria for 30 years. ASTM E1264 Classification Type III, Form 1, Pattern E I K Fire Class A Insulation Value R Factor – 1.9 (BTU units) R Factor – 0.33 (Watts units) Application Considerations Not recommended for rooms containing MRI equipment. 30-Year Performance Guarantee & Warranty Information See warranty details at armstrong.com/warranty Weight; Square Feet/Carton 1.09 lbs/SF; 48 SF/ctn Backloading Recommendation Contact TechLine for specific information TechLineSM / 1 877 ARMSTRONG 1 877 276 7876 armstrong.com/ceilings (search: cirrus) CS-3013-610 LEED® is a registered trademark of the U.S. Green Building Council All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates © 2010 AWI Licensing Company • Printed in the United States of America