NORTON INDUSTRIES

advertisement
NORTON INDUSTRIES
1366 West 117th Street
Lakewood, OH 44107
PH: 216-228-6650 FX: 216-228-9065
www.nortonceilings.com
REQUEST FOR APPROVAL
TO:
Cc:
Portland State University
Merryman Barnes Architects
DATE OF REQUEST: 8/21/13
PROJECT BID DATE: 9/4/13
PROJECT: PSU Student Health & Counseling
SPECIFICATION REFERENCES: 09510 Acoustical Ceilings
SPECIFIED ITEM: 9Wood, Inc.
PROPOSED SUBSTITUTION: Norton Industries 216-228-6650
MANUFACTURER: Norton Industries Inc., 1366 West 117th St, Lakewood, OH 44107
DEVIATIONS FROM SPECIFIED ITEM: None in technical function, form or quality.
None in design criteria, as compared to products specified. Terminology may vary with
individual product descriptions.
MANUFACTURER RECOMMENDATIONS FOR USE AND INSTALLATION: Refer
to accompanying portfolio for further information.
TECHNICAL DATA TO SUPPORT REQUEST FOR APPROVAL: Enclosed product
information. www.nortonceilings.com
PARTY PROPOSING SUBSTITUTION APPROVAL: Norton Industries Inc.
COMMENTS: Substitution is requested based on enclosed product and data being equal
to specification requirement and basis of design.
Respectfully Submitted,
Jennifer Bentley
Norton Industries Inc.
216-228-6650 Ext. 11
jennifer@nortonceilings.com
UCB Center for Student Health & Counseling Expansion & Remodel – GC
Portland State University
CC: Merryman Barnes Architects
August 2013
PSU Student Health and Council
9Wood
09510
3
END OF SECTION
2.02-E #2
ACT-2 Wood Ceiling Tile
NWP-Wood Panel
Jennifer Bentley
Jennifer Bentley
Norton Industries
1366 W. 117th St.
Lakewood, OH 44107
8/22/13
216-228-6650
216-228-9065
Requirements and Substitutions
Section 01630
1
NORTON INDUSTRIES
“CREATIVE CEILING ALTERNATIVES”
Substitution Product Comparison
Project: PSU Student Health and Council
Architect: Merryman Barnes Architects
General Contractor: N/A Interior Subcontractor: N/A
Date: 8/22/13
Basis of Specification: 9Wood
Section 09510
Acoustical Ceilings
Paragraph: 2.01-E #2
The undersigned requests approval by the following product comparison.
Specified
Product
Mfg. By
Material
Size
Finish
Species
Edgebanding
Core
NRC
Suspension
Edge Profile
Perforations
Flame Spread
Warranty
Dimensional
Stability
Perforated Wood Tiles
9Wood
FSC Wood
2’ x 4’ and 2’ x 2’
TBS from Standard Veneers
N/A
MDF – Particle Board
0.55
XL Channel System
3/8” Reveal
8mm Hole @ 32mm O.C.
Staggered Pattern
Class C
One (1) year limited warranty
Standard
Substitution
Product
Mfg. By
Material
Size
Finish
Species
Edgebanding
Core
NRC
Suspension
Edge Profile
Perforations
Flame Spread
Warranty
Dimensional
Stability
NWP-Wood Panels
Norton Industries
FSC Wood
2’ x 4’ and 2’ x 2’
TBS from Standard Veneers
N/A
Duraflake Fire Rated MDF
0.55
Heavy duty, 15/16” T Grid
Shadow Reveal
8mm Hole @ 32mm O.C.
Staggered Pattern
Class C
One (1) year limited warranty
Standard
Deviations From Specified Item: None in technical function, form or quality. None in
design criteria as compared to products specified. Terminology may vary with
individual product descriptions.
* NRC achieved when adding fiberglass infill pad.
NORTON INDUSTRIES
“CREATIVE CEILING ALTERNATIVES”
Similar Installations
Wood Ceiling Panels
Mead Valley Library
Perris, CA 92570
2012
WWCOT Architecture
Riverside, CA 92501
951-682-0470
Alsip Library
Alsip, IL 60803
2012
PSA-Dewberry, Inc.
Peoria, IL 61602
Rocky River High School
Rocky River, OH 44116
2012
Burt Hill Architecture
Cleveland, OH 44122
Halpern Residence
Moreland Hills, OH 44022
2011
RSA Architects
Chagrin Falls, OH 44022
Safety Clip
factory supplied
Main Tee (BO)
MDF Core
1
4
20 insert
1366 West 117th Street Lakewood, Ohio 44107
(216) 228-6650 or (888) 357-2345
1'-11 3/4"
Fax (216) 228-9065 or (800) 462-6650
3/4"
www.NortonCeilings.com
FSC# BV-COC-012533BL
Veneer
Face
1/2"
1/4"
Edge B
#
REVISIONS
DATE
Edge C
1'-11 3/4"
scale: 6"=1'-0"
ARCHITECT
2"
3"
CUSTOMER
3/8"
REPRESENTATIVE
Edge B
Wood Grain Direction*
PROJECT TITLE
scale: FULL
scale: 1"=1'-0"
Note: Standard Shadow Panel - grain runs parallel to Edge B. Grain can
run perpendicular to Edge B if requested.
\\AUTODESK\Norton Industries\00 New Masters\NWP-SM Shadow\PANELS\STANDARD PANELS\NWP22SM-P.dwg
PROJECT LOCATION
Size:
Nominal 2'x2' panel
SHEET REFERENCE
Core:
3/4 " MDF
Veneer:
Per Architect Specification
Finish:
SHEET TITLE
Stain:
Clear Lacquer, Standard low VOC
content, 20% sheen
Options Available
Rating:
Class A per ASTME84
DATE
4.23.13
Sound:
Soundtex Backer - available
SHEET NO.
PRODUCT
NWP22-sp-f-fr-SM-perf
DRWN
EA
CHECK
EA
3'-11 3/4"
NWP 24 Norton Wood Panel,
Shadow Edge
Size:
Nominal 2' x 4'
Veneer:
See catalog for options
Stain:
Custom stain available
Finish:
Core:
Standard low VOC content,
20% sheen
3/4 " MDF
Rating:
Class A per ASTME84
1366 West 117th Street Lakewood, Ohio 44107
(216) 228-6650 or (888) 357-2345
Fax (216) 228-9065 or (800) 462-6650
www.NortonCeilings.com
FSC# BV-COC-080411
Edge C
Edge C
1'-11 3/4"
Edge B
Type:
#
DATE
Safety Clip
factory supplied
Edge B
Wood Grain Direction*
REVISIONS
Panel Front
Main Tee (BO)
MDF Core
Safety Clip, factory supplied
field installed (panels come with
1
4 20 inserts for safety clip attachment
4
20 insert
ARCHITECT
3/4"
Edge B
1
1/2"
CUSTOMER
1/4"
Veneer
Face
Edge C
Edge C
Edge B
REPRESENTATIVE
PROJECT TITLE
Cross Tee (BO)
PROJECT LOCATION
SHEET REFERENCE
Edge B
Edge C
Panel Back
PRODUCT
NWP-C-24-sp-f-fr-SM
SHEET TITLE
scale: 1"=1'-0"
Note: Standard Shadow Panel - grain runs parallel to Edge B. Grain can
run perpendicular to Edge B if requested.
\\AUTODESK\Norton Industries\00 New Masters\NWP-SM Shadow\PANELS\STANDARD PANELS\NWP24SM-MS01.dwg
scale: 6"=1'-0"
DATE
10-17-12
SHEET NO.
DRWN
A.R.
CHECK
EA
l
o
o
k
i
n
g
f
o
r
w
a
r
d
t
o
l
o
o
k
i
n
Wood Panel
N
NORTON
INDUSTRIES
INC.
www.nortonceilings.com
g
u
p™
CEILINGS
& WALLS
l o o k i n g
f o r w a r d
t o
l o o k i n g
u p
™
Wood Panel
CEILINGS
& WALLS
uses solid wood veneers • class A fire-rated
coating available • FSC® certified wood available •
variety of panel sizes • perimeter caps & cutouts
for fixtures • 4 mounting styles that work with
standard t-bar suspensions • 13 standard perforation
patterns or customize your own
2' x 2' panels, flush lay-in mounting, natural select white maple, clear topcoat
STAN DARD PAN EL SIZ ES
2' x 2', 2' x 3', 2' x 4', 1' x 4', 3' x 3', 4' x 4', 1' x 5', 2' x 5'
Custom panel sizes available.
STAN DARD V ENEER SELECTION
There are many other veneer options available. For inquiries, please call us at 888.357.2345
AFRORMOSIA
QUARTERED (AQ)
ANIGRE, PLAIN
SLICE (AP)
ASH, WHITE
QUARTERED (AWQ)
BAMBOO, CARAMEL
NARROW CANE
(BCN)
BAMBOO, CARAMEL
WIDE CANE (BCW)
BAMBOO, NATURAL
NARROW CANE
(BNN)
BAMBOO, NATURAL
WIDE CANE (BNW)
BEECH, EUROPEAN
STEAMED
PLAIN SLICE (BEP)
BIRCH,
SELECT WHITE
ROTARY CUT (BSWR)
CHERRY,
PLAIN SLICE
BOOK MATCH (CPB)
CHERRY,
QUARTERED (CQ)
DOUGLAS FIR
ROTARY CUT (DFR)
EUCALYPTUS
PLAIN SLICE
BOOK MATCH (EPB)
HICKORY
PLAIN SLICE
BOOK MATCH (HPB)
MAHOGANY
PLAIN SLICE (MP)
MAPLE, WHITE
ROTARY CUT (MWR)
MAPLE, SELECT
WHITE PLAIN SLICE
BOOK MATCH
(MSWPB)
OAK, RED
PLAIN SLICE
BOOK MATCH
(ROPB)
OAK, RED
RIFT CUT
BOOK MATCH
(RORB)
OAK, WHITE
RIFT CUT (WOR)
SAPELE
PLAIN SLICE (SP)
WALNUT (W)
UN -W RAP P ED
Norton Industries uses solid woods and veneers harvested
by suppliers certified by one of The Forest Stewardship
Council™ third party organizations. We also offer solid woods
and veneers that carry the FSC® Chain of Custody Certificate.
PARTICLE BOARD
(PB)
PLAIN MDF (MDF)
Note: the veneer colors and grain shown here are representative of the species only
F INISHING
FIRE RAT IN G
Our standard panel finishing process uses low
VOC sealers and lacquers that have a 20% sheen.
Our standard Norton Wood Panel product is made
of a core that carries a Class A fire-rating in accordance with test ASTM E84. Non fire-rated cores
are also available where applicable due to sprinkler
systems and other factors and do provide cost
savings when used.
It is important to note that wood color, grain and
texture can vary from panel to panel when in its
natural state. Staining can reduce these variations.
The standard panels we provide are matched by
architectural grade quality standards. Panels should
be viewed prior to installation into the ceiling to
assure color variance is appropriately positioned.
Panels can be stained to either match existing
wood in the space, match architectural selection,
or to minimize the color variance in panels.
tel: 888.357.2345
RECYCLED CON T EN T
Norton Wood Panels have a 96-99% recycled
content. Of that recycled content, 96.47% is preconsumer and 3.53% is recovered/other material.
In addition, our packaging is designed to be
entirely recyclable, making it easy to divert
construction waste from landfills
fax: 800.462.6650
www.nortonceilings.com
AVAILABLE LEED ® CREDITS
✓ MR Credit 2.1/2.2
Construction Waste Management
✓ MR Credit 4.1/4.2
Recycled Content
✓ MR Credit 5.1/5.2
Regional Materials (location dependent)
✓ MR Credit 6.0
Rapidly Renewable Materials
✓ MR Credit 7.0
Certified Wood
✓ EQ Credit 3.1/3.2
Construction IAQ Management Plan
✓ EQ Credit 4.1/4.2/4.4
Low Emitting Materials
NORTON
INDUSTRIES
INC.
W O O D
P A N E L
standard z-clip
WALL M O UN TIN G
z-clip attached to
the wood panel
Wood panels mount to wall/furring
system using factory supplied Z-clips or
exposed decorative fasteners. The reveal
between panels is a minimum of 1/8"
and has no maximum.
■
■
z-bracket attached
to the wall
all visible edges of wall panels are
covered with veneer, optional stain
and double clear topcoat
exposed fasteners
typical panels are 3/4" thick, but
thicker panels are available
CO RNER TREAT M ENT
OP TIO NS
option 1
Wall angle on the outside
of the corner. Matching
veneer and finish.
REV EAL O P T IO N S
panel spline
black, silver satin, matching or complimentary
veneer or custom finish
veneer
3/8"
MDF core
1/16" minimum reveal between panels
PERIMETER CAP
T-BAR
SHADO W 1/ 4" REVEAL
CO NCEALED SUSPENSION
The perimeter of the wood ceiling panel is routed
with a series of two different cuts to allow the ceiling
panel to install into heavy-duty 15/16" t-bar grid,
supplied by Norton Industries or others. Once the
panel is in position, the grid is concealed, leaving
only a 1/4" gap between panels where the t-bar grid
is 1/2" behind the surface of the panel.
Available in heavy-duty
15/16" t-bar grid
2" - 10"
ceiling
MOUNTING STYLE
option 4
Other side extended.
All edges veneered and
finished to match.
option 3
One side extended.
All edges veneered and
finished to match.
option 2
Wall angle on the inside
of the corner. Matching
veneer and finish.
3/4"
wall
ASSEMBLY & MOUN TIN G
shadow perimeter cap
Special safety clips and brackets are supplied
with Concealed Mount Panels.
Available in heavy-duty
15/16", standard 9/16",
1-1/2" and 3" t-bar grid
2" - 10"
The perimeter of the wood ceiling panel is routed to
allow the panel to drop slightly below the t-bar grid
surface. The standard depth of the tegular route is 1/8".
All four suspension sizes of t-bar grid are available for
a tegular ceiling panel. If our suspension system is
not being used with our ceiling panel, it is important
we know the dimension of the grid being used to
assure proper edge treatment. The grid can have
matching veneer or a painted finish.
2" - 10"
T EGULAR M O UN T IN G
9/16" tegular
perimeter cap
15/16" tegular
perimeter cap
The wood ceiling panel rests flush on exposed t-bar
grid. All four t-bar grid sizes will work with this mounting system. The t-bar grid is fully exposed in this
application which makes finish selection important.
Available in heavy-duty
15/16", standard 9/16",
1-1/2" and 3" t-bar grid
2" - 10"
F LUSH M O UNTIN G
flush mount perimeter cap
www.nortonceilings.com/panel
W O O D
P A N E L
P ERF ORAT ION OPTIO N S - CEILIN G & WALL
Perforation options are available on ALL panel sizes. Standard panels are solid (non-perforated). Perforated panels can simply be an aesthetic design — or one of performance.
Perforated panels can have acoustical fleece factory installed and/or an acoustical pad installed on top of the panel for increased acoustical performance.
D10X40W
R6X31W
R6X31N
R10X40W
R10X40N
3/8" diamond hole
1 9/16" on center
wide border (3.52% open)
1/4" round hole
1 1/4" on center
wide border (1.9% open)
1/4" round hole
1 1/4" on center
narrow border (2.5% open)
3/8" round hole
1 9/16" on center
wide border (3.24% open)
3/8" round hole
1 9/16" on center
narrow border (3.76% open)
S6X31W
S6X31N
S10X40W
S10X40N
S10X40W-S
1/4" square hole
1 1/4" on center
wide border (2.44% open)
1/4" square hole
1 1/4" on center
narrow border (3.14% open)
3/8"
3/8" square hole
1 9/16" on center
narrow border (4.78% open)
3/8" square hole
1 9/16" on center
staggered border (3.76% open)
SLT25SW
SLT25MW
SLT25LW
square hole
1 9/16" on center
wide border (3.51% open)
CUSTOM PERFORATION
PATTERNS AVAILABLE...
1/8" x 3/8" slot
1 1/8" on center
(3.52% open)
1/8" x 1 5/32" slot
1 7/8" on center
(6.9% open)
1/8" x 3 7/16" slot
4 29/32" on center
(8.5% open)
We can create any perforation pattern you
choose! Corporate logos, letters, numbers,
geometric designs, random lines and/or
patterns. For full details, call one of our
representatives at 888.357.2345.
Complimentary Engineering Services Include:
Autocad Shop Drawings • Product Samples • Custom Stain Matches •
Custom Panel Sizes to Minimize Field Modification • Light Hole Cutouts
GEN ERAL IN STALLATIO N
Storage
Our panels are made of wood products, so they
should be stored flat, in their cartons, in a dry
location prior to installation. Use care when
handling to avoid damaging the panels or getting
them stained or scratched. The ideal conditions
for storage are humidity levels between 20% and
55% and temperatures between 50ºF and 86ºF.
Panels must not be exposed to extreme temperatures, for example, close to a heating source or
near a window where there is direct sunlight. All
climate control systems should be in place and
operational and the panels should be allowed to
adjust to conditions similar to those in which they
will be installed for a minimum of 72 hours prior
to installation. They should not, however, be
installed in spaces where the temperature or
humidity conditions vary greatly from the temperatures and conditions that will be normal in the
occupied space. Obviously, any and all construction and subsequent clean-up should be completed prior to installation.
Ceiling Suspension Requirements
■
■
Heavy-duty grid using no less than 12-gauge
steel wire.
Must conform to ASTM C-636 requirements
and ASTM E-580 seismic recommendations.
■
■
■
■
Panels are 2.75 lbs. per square foot, and the
mains should be capable of carrying 12 lb/lf
and the cross tees 6 lb/lf.
The suspension system must be leveled to
within 1/4" in 10' and must be squared to within
1/16" in 2'. Installation of grid systems that do
not meet this tolerance will produce unacceptable panel alignment.
Flush Mount and Tegular Mount panels simply
lay into t-bar grid.
Shadow Mount panels lift and shift into heavyduty 15/16" t-bar grid.
www.nortonceilings.com/panel
Download