EDGE EV3P E V O L U T I O N T5, T5HO, T8 Recessed Linear with Straight and Staggered Lamp / Parabolic Louver Project Name Date Catalog Number Type CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflec- tive die-formed white painted steel reflector. Die-formed anodized(1)snap-in aluminum semi-specular parabolicLamps louver (1) Staggered or (2) Straight Lamps removable for lamp replacement. ELECTRICAL T5, T5HO: Standard programmed start UL listed Class P, T5 electronic, sound rated A, thermally protected, 5-1/8” high power factor ballasts less than 10% THD, universal voltage (120/277) with 50/60Hz operation. T8: Standard instant start UL listed Class P, T8 electronic, Sound Rated A, thermally protected, high power factor ballasts less than 10% THD, universal voltage (120/277). Through wiring with quick1T5/T5HO, connects 1T8 standard. Standard single 1T5/T5HO circuit. Integral 2T5/T5HO battery packs with remote test switch are provided with 1B and 2B options. Each ballast provided with disconnects to meet luminaire disconnect code requirement. MOUNTING Edge3”is designed to install into acoustical grid and inaccessible ceilings. Specify GXG, FLF, SFS, NFN for individual, unjoinable G1/G9/GS:units (individual units will fall on-grid). Specify GX, FL, SF, NF for continuous runs (runs designed to fall on-grid).3-13/16” Grid retention brackets are integral to housing. Each housing contains 4 grid retention brackets. Consult factory for FL detailed installation instructions. & FLF: 4-1/8” See Straight or Staggered Lamp Guide for row FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze consult configuration, wattage and numberpainted of lampsfinish, per run. factory for chip of standard paint finishes. Contact factory for additional custom color and finish options. LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted. (1) or (2) Straight Lamps Staggered Lamps YEAR LED WARRANTY Staggered Lamps (1) Staggered Lamps 5-1/8” LFL 1T5/T5HO, 1T8 LED Convertible 2T5/T5HO 1T5/T5HO Convertible LED LFL 3” G1/G9/GS: 3-13/16” FL & FLF: 4-1/8” See Straight or Staggered Lamp Guide for row configuration, wattage and number of lamps per run. L U M I N A I R E S P E C I F I C AT I O N Sample Catalog #: EV3P-1T5-24’-FL-120-1C-W EV3_P- _T___- ___’- ___- ___- HOUSING LAMPS LENGTH MOUNTING 1 VOLTAGE LFL Convertible 5-1/8” LED EV3P- Edge Evolution 3, Parabolic Louver, Straight Lamp EV3SP- Edge Evolution 3, Parabolic Louver, Staggered Lamps 1T52T51T5HO2T5HO1T8- (1) T5 (2) T510 (1) T5HO (2) T5HO10 (1) T810 __-(1) or (2) Straight__Lamps YEAR LED WARRANTY Individual Units (CANNOT BE JOINED) Acoustical Grid Ceiling12 G1G- 1” Ceiling Grid G9G- 9/16” Ceiling Grid 3” GBG- 9/16” Ceiling Grid with Bevel Trim G1/G9/GS: 3-13/16” Grid GSG- Screw Slot Ceiling 120- 120 V FL & FLF: 4-1/8” Inaccessible Ceiling 277- 277 V FLF- Standard 1/2” Flange 347- 347 V5 SFS- Spackle Flange UNV- UNV5 4 NFN- Flangeless (120-277) Continuous Runs (JOINABLE)3 Acoustical Grid Ceiling12 G1- 1” Ceiling Grid G9- 9/16” Ceiling Grid GB- 9/16” Ceiling Grid with Bevel Trim GS- Screw Slot Ceiling Grid Inaccessible Ceiling FL- Standard 1/2” Flange SF- Spackle Flange NF- Flangeless4 CIRCUITING Continuous Runs3 xx’- Specify row length to 1’ increments OPTIONS LED Convertible LFL CPW- Matte White MRFS- 1T5/T5HO, Metallic 1T8 Silver2T5/T5HO LMRFBL- Textured Black PMGR- Graphite RCBR- Bronze LOCC- Custom Color 2 Individual Units2 2- 2’, 23” fixture (Staggered not available)2 3- 3’, 35” fixture (Staggered not available)2 4- 4’, 47” fixture (Staggered not available)2 6- 6’, 71” fixture2 8- 8’, 95” fixture2 FINISH ____ (1) Staggered Lamps Chicago Plenum 1T5/T5HO Fixed MR16 Halogen11 Fixed MR16 LED11 Perimeter Mount7 Rotating Crossbar8 Lens Overlay See Straight or Staggered Lamp Guide for row configuration, wattage and number of lamps per run. Single Circuit Dual Circuit Single Circuit Dimming6 Dual Circuit Dimming6 Single Circuit with Battery Pack6,9 2B- Dual Circuit with Battery Pack6,9 1E- Single Circuit with Emergency Circuit6 2E- Dual Circuit with Emergency Circuit6 1C2C1D2D1B- 1 See back page for mounting detail. 2Individual units cannot be joined. All end trims are factory installed and cannot be removed in the field. 3Continuous rows made up of both even and odd length fixtures. Designed to fall on-grid. 4NF and NFN to be utilized for metal pan / millwork ceiling. 5347 and UNV not available with battery pack. 6Some Edge configurations will not accommodate all electrical options. Consult factory. 7Available for acoustical grid ceilings. Wall rail painted white unless otherwise specified. 81/2” to 5/8” drywall thickness. Available for standard 1/2” flange (FL). 9Integral battery packs with remote test switch are provided with 1B and 2B option. 10Staggered lamp available for 1T5 and 1T5HO only. 11Consult MR16 Resource Guide for configurations using MR16 units. 12 See page 3 for grid retention bracket details. ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® February 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. Part #: EV3H-2T5-4’ Total Luminaire Efficiency: 51.9% Part #: EV3H-1T5-4’ Total Luminaire Efficiency: 58.6% EV3A, EV3H Part #: EV3H-1T8-4’ Total Luminaire Efficiency: 54.1% Side Views 48”, 72”, 96” P H O T O M 23" ETRICS 2' 1” Grid, Standard Tile: 1” Grid, Tegular Tile: Part #: EV3R-2T8-4’ Total Luminaire Efficiency: 00% EDGE EVOLUTION 23”, 35”, 47”, 71”, 95” 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: Screw Slot Grid: lens per 2'805 unit (2’ individual unit in notpart available withG9 staggered 853in part # Use GS or GSG in part # Use GS or1737 Use G1 or(1)G1G in part # Use G1 or G1G # Use or G9Glamp) in1680 part # Use G9 or G9G in part # Use GB or GBG GSG in part # 71”639 or 72” 35" 1260 604 1303 3' 47” or 48” 4' 6' 840 403 (1) lens per 3' unit (3’ individual unit not available with staggered lamp) 420 201 Flange Detail Non-Flange 426 869 434 Rotating Crossbar 95” or 96” 8' (1) lens per 4' unit (4’ individual unit not available with staggered lamp) (1) lens per 6' unit 213Mount Perimeter Spackle Flange (1) lens per 8' unit 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. Test #: 204785 Part #: EV3P-2T5-4’ Total Luminaire Efficiency: 64.8% Test #: 204782 Part #: EV3P-1T5-4’ Total Luminaire Efficiency: 70.8% EV3P Test #: 204784 Part #: EV3P-1T8-4’ Total Luminaire Efficiency: 66.2% 1 Exposed Flange Detail: Pan or Millwork: RUN Drywall, Flangeless Look: INDIVIDUAL AND Metal CONTINUOUS MODULES Unavailable Structure Support: SideBracket Views and Wall Rail: 48”, 72”, 96” 23”,#35”, 47”, 71”, 95” Specify RC in part # Specify PM in part Specify FL or FLF 23" in part # Specify NF or NFN in part # Specify SF or SFS in part # 2' 3' 4' (1) louver per 2' unit (2’ individual unit not available with staggered lamp) 1049 1242 35" 1175 787 931 6' 525staggered lamp) (1) louver per621 3' unit (3’ individual unit not available with 31047” or 48” 262 8' 1208 1051 906 604 789 71” or 72” 881 (2) louvers per 6' unit 587 526 95” or30296” 294 (1) louver per 4' unit (4’ individual unit not available with staggered lamp) Test #: 000000 Part #: EV3P-2T8-4’ Total Luminaire Efficiency: 00% 263 (2) louvers per 8' unit 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. MOUNTING DETAILS Test #: 204795 Test #: 204775 Part #:1”EV3C-2T5-4’ Grid Mounting OptionsPart #: EV3CL-2T5-4’ Total Luminaire Efficiency: 57.3% Total Luminaire Efficiency: 49.3% Test #: 204800 Test #: 204790 Part #: EV3CM-2T5-4’ Part #: EV3CG-2T5-4’ 9/16” Grid Mounting Options Total Luminaire Efficiency: 50.7% Total Luminaire Efficiency: 55.3% Test #: 204805 Part #: EV3CR-2T5-4’ Screw Slot Total Luminaire Efficiency: 47% Mounting 1473 1236 1430 1437 1246 1105 927 1072 934 737 618 715 1078 719 623 1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: Screw Slot Grid: 368 305 355 357 311 Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part # SPECIALTY MOUNTS INACCESSIBLE CEILING MOUNTING Flange Detail Non-Flange Test #: 204810 Part #: EV3D-2T5-4’ Total Luminaire Efficiency: 66.8% Spackle Flange Test #: 204820 Part #: EV3DL-2T5-4’ Total Luminaire Efficiency: 58% Test #: 204825 Part #: EV3DM-2T5-4’ Total Luminaire Efficiency: 59.8% Exposed Flange Detail: Metal Pan or Millwork: Drywall, Flangeless Look: Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part # MR16 LAMPS APPLICATION: MR16’s are ideal for conference rooms, corridors, wall washing, retail spaces and training facilities where accent lighting is required. TECHNICAL: MR16 fully enclosed compartment eliminates light from entering into other fixture areas. Available in 20, 35 and 50 watt halogen lamps, 4 and 8 watt LED lamps. (lamps not included). Consult factory for other lamp types. MR16 lamp is in a fixed position. ELECTRICAL: Standard 50 watt max halogen lamp transformer (120v or 277v), 60 watt max LED electronic transformer (120v only). MR16 installed as independent circuit. MR16 voltage to match fluorescent voltage. ® Perimeter Mount Rotating Crossbar Test #: 204814 Part #: EV3DG-2T5-4’ Total Luminaire Efficiency: 64.8% Bracket and Wall Rail: Specify PM in part # Test #: 204830 Part #: EV3DR-2T5-4’ Total Luminaire Efficiency: 56% Unavailable Structure Support: Specify RC in part # LABELS: UL and cUL Listed, approved for dry/damp location unless otherwise noted. ORDERING INFORMATION: Specify MR16 layout and lens in the options section of the part number. Sample Catalog #: EV3P-1T5-4G1-120-1C-W-M4M. See MR16 Resource Guide for Layout and Lens Options. Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® February 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. GRID RETENTION BRACKET EDGE EVOLUTION Joint holes Joint for holes #8-32 for #8-32 ScrewsScrews GRID RETENTION: At every joint, the addition of grid retention brackets results in a sturdy connection between the fixtures and the grid. Insert screws through the bracket into the grid to secure. JOINT ALIGNMENT: Incorporating biscuits and screws not only creates a secure joint but also aids in fixture alignment. BiscuitBiscuit ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® February 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.