Gyptone GRID

advertisement
Gyptone GRID
Suspended grid ceiling system
www.gyproc.ae
184
Alruwad International School - Sultanate of Oman
Gyptone GRID
0.40
-
0.80
αw
Sound Absorption
37
39
DncwdB
Gyptone GRID
Gyptone GRID is a lightweight ceiling system available in concealed or exposed grid options. It presents an
attractive pre-finished white ceiling possible by selecting the desired tile or plank edge profile. Pre-finished plank
is available in smooth or perforated options.
Key facts
• Concealed or exposed grid options
• Attractive pre-finished white surface
• Wide range of ceiling tiles and planks giving smooth or perforated effect
• Provides sound attenuation and absorption
• Electrical and other services accommodated in plenum
• Will support loads up to 3kg per tile without a pattress (1kg per tile for D2 edge)
Applications
Due to the design flexibility of Gyptone
applications.
GRID,
this system can be tailored to meet the requirements of a wide range of
Sector
Office / commercial
Retail
Sport and leisure
Education
Healthcare
Auditoria
Apartment buildings
High-rise multi-occupancy
www.gyproc.ae
185
System components
Gyptone metal products
Gyptone GRID
Gyptone Main ‘T’
24mm Main ‘T’
section, for Gyptone
A&E edge tiles
Cross Lock connector
For Gyptone D2 Edge tiles
Length
3600mm
Gyptone Cross ‘T’
24mm Cross ‘T’
section, for Gyptone
A&E edge tiles
Adjustable hangers
for length between
90-1500 mm
(refer Table-1 for available lengths)
Length
600mm
1200mm
Connecting bracket
Gyptone Main ‘T’
15mm
for Gyptone
A&E edge
Length
3600mm
Gyptone Cross ‘T’ section
15mm
for Gyptone
A&E edge
Length
600mm
1200mm
Wall springs
For Gyptone D2 Edge tiles
Gyptone Main ‘T’
15mm Main ‘T’
section, for 1800mm
Gyptone planks. 19
Lighting fitting bracket XT
Length
24
1830mm
25
5
12
15
24
Gyptone Main ‘T’
15mm Main ‘T’
section, for 2100mm
Gyptone planks.
Length
Gyptone Main ‘T’
15mm Main ‘T’
section, for 2400mm
Gyptone planks.
Length
Gyptone Wall Angle
22x19mm Wall Angle.
Length
Metal products (by others)
2130mm
Suspension wire by others
Ceiling tile and plank products
2430mm
A wide range of products available in
Gyptone options.
3600mm
For more info, see Products - Section 10
NB
Gyptone Shadow Angle
19+9 x 19+9mm
Shadow Angle.
Length
Plank Edge Profile
Plank Edge Profile
for Gyptone planks.
Length
38
3600mm
3000mm
Edge Details
38
Gypframe Soffit Cleat
24
15
with Nut & Bolt
Suspension point from structural soffit
A
T15/T24
Length
T-24
3600mm
For Gyptone D2 Edge tiles
and XtensivTM range
E15
Length
T-24
3600mm
For Gyptone D2 Edge tiles
and XtensivTM range
E24
Main beam unipro
Cross profile unipro
Wall angle
24x24mm
For Gyptone D2 Edge tiles
25+5 x 15+15mm
Shadow Angle.
3000mm
D2
24mm T sections
T24D2
Length
3000mm
Eligible for the
SpecSure warranty
from Gyproc
186
24
25
5
19
24
12
15
www.gyproc.ae
FUTURE PROOF
Gyptone XtensivTM
Shadow Angle
Length
15mm T sections
System components (continued)
Edge Details (continued)
Insulation products
Plank - E15/A
Isover Acoustic Partition Roll
Long Edge
70mm and 100mm, for improved acoustic performance.
Density 16Kg/m3
Gyptone GRID
Short Edge
Table 1: T-grid cross lock system with adjustable hangers
T-24
Adjustable 115-150
Min. Height
195
mm
Max. Height
235
mm
T-24
Adjustable 165-250
Min. Height
245
mm
Max. Height
335
mm
T-24
Adjustable 190-300
Min. Height
270
mm
Max. Height
385
mm
T-24
Adjustable 340-600
Min. Height
420
mm
Max. Height
685
mm
T-24
Adjustable 540-1000
Min. Height
620
mm
Max. Height
1095
mm
T-24
Adjustable 1040-1300
Min. Height
1120
mm
Max. Height
1395
mm
T-24
Adjustable 1040-1500
Min. Height
1120
mm
Max. Height
1595
mm
Installation overview
T15 grid for Gyptone planks
Plank edge profile is fixed to the wall at 300mm centres.
Reduce the Main ‘T’ sections by a maximum of 10mm, in
relation to the width of the room or corridor and fit into Plank
edge profile on the upper recessed flange. There is no
requirement to install hangers to support the Main ‘T’
sections. Main ‘T’ sections should not be joined.
No soffit supports / hangers required. Gyptone planks are
located on the lower flange of the Plank edge profile. Corners
and alcoves require specific detailing, see Construction
details – 8.
Gyptone 15mm and 24mm grids for A and E edge tiles
Gyptone GRID should be used to form a 600mm x 600mm grid.
For Installation of Gyptone D2 edge tiles, see Construction
details – 3.
www.gyproc.ae
187
Table 2 – Sound absorption data for Gyptone Activ’Air Tiles and Planks
Gyptone Activ’Air
Quattro 20
Practical absorption coefficient
p
1.0
0.8
0.45
0.40
0.6
0.75
0.80
0.80
0.70
0.80
0.70
0.70
0.60
0.75
0.70
0.80
0.70
0.65
0.55
0.75
0.70
0.75
0.70
0.65
0.55
0.70
0.65
0.75
0.65
0.60
0.50
0.70
0.70
0.70
0.65
0.75
0.60
0.75
0.70
0.80
0.70
Construction height 300mm with
70mm Isover APR
Construction height 200mm
0.4
0.2
Gyptone GRID
0.70
0.70
0.0
125
250
Frequency
Gyptone Activ’Air
Quattro 50
500
1k
Practical absorption coefficient
2k
4k
Hz
p
1.0
0.8
0.45
0.45
0.6
0.70
0.70
0.75
0.80
0.80
0.70
0.75
0.65
Construction height 300mm with
70mm Isover APR
Construction height 200mm
0.4
0.2
0.0
125
250
Frequency
Gyptone Activ’Air
Point 11
500
1k
Practical absorption coefficient
2k
4k
Hz
p
1.0
0.8
0.45
0.45
0.6
0.65
0.65
0.75
0.75
0.75 0.70
0.65 0.60
Construction height 300mm with
70mm Isover APR
Construction height 200mm
0.4
0.2
0.0
125
250
Frequency
Gyptone Activ’Air
Line 4
500
1k
Practical absorption coefficient
2k
4k
Hz
p
1.0
0.8
0.45
0.40
0.6
0.65
0.70
0.75
0.80
0.75
0.65
0.65
0.60
Construction height 300mm with
70mm Isover APR
Construction height 200mm
0.4
0.2
0.0
125
250
Frequency
Gyptone Activ’Air
Sixto 60
500
1k
Practical absorption coefficient
2k
4k
Hz
p
1.0
0.8
0.50
0.45
0.6
0.70
0.70
0.75
0.80
0.80 0.80
0.70 0.70
Construction height 300mm with
70mm Isover APR
Construction height 200mm
0.4
0.2
0.0
125
250
Frequency
500
1k
2k
4k
Hz
Gyptone Activ’Air
Base 31
188
NB All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw is calculated in accordance with
EN ISO 11654.
www.gyproc.ae
Table 2(continued) – Sound absorption data for Gyptone Activ’Air Tiles and Planks
Gyptone Plank
Point 15
Practical absorption coefficient
p
1.0
0.8
0.45
0.6
0.65
0.75
0.65 0.60 0.55
0.65
0.65
0.55
0.50
0.30
0.30
0.30
0.35
0.60
0.60
0.45
0.45
0.50
0.50
0.55
0.50
0.45
0.45
0.45
0.45
Construction height 200mm
0.4
Gyptone GRID
0.2
0.0
125
250
Frequency
500
1k
2k
4k
Hz
Other Plank products
Line 8
125
0.40
250
0.70
500
0.80
1000
0.65
2000
0.60
4000
0.50
125
0.45
250
0.70
500
0.80
1000
0.70
2000
0.65
4000
0.55
0.70
0.65
Quattro 55
Xtensiv
Line 8
Base 33
Practical absorption coefficient
0.70 0.70
p
1.0
0.8
0.30
0.35
0.6
0.25
0.25
0.25
0.30
0.30 0.35
0.30 0.35
Construction height 300mm with
70mm Isover APR
Construction height 200mm
0.4
0.2
0.0
125
250
Frequency
Xtensiv
Point 15
500
1k
Practical absorption coefficient
2k
4k
Hz
p
1.0
0.8
0.40
0.35
0.6
0.40
0.40
0.40
0.45
0.50 0.50
0.45 0.50
Construction height 300mm with
70mm Isover APR
Construction height 200mm
0.4
0.2
0.0
125
250
Frequency
Xtensiv
Quattro 55
500
1k
Practical absorption coefficient
2k
4k
Hz
p
1.0
0.8
0.35
0.35
0.6
0.35
0.35
0.35
0.40
0.45 0.60
0.45 0.55
Construction height 300mm with
70mm Isover APR
Construction height 200mm
0.4
0.2
0.0
125
250
Frequency
500
1k
2k
4k
Hz
Xtensiv
Base 33
www.gyproc.ae
189
Table 3 - Sound insulation
Ceiling product
Dn,c,w dB
no insulation
Dn,c,w dB
100mm Isover Spacesaver Plus
System
reference
Gyptone GRID
Tiles
Gyptone BASE 31
37
-
C10A008
Gyptone SIXTO 60
-
39
C10A105
Gyptone LINE 4
-
39
C10A004
Gyptone QUATTRO 20
-
39
C10A003
Gyptone QUATTRO 50
-
39
C10A003
Gyptone POINT 11
-
39
C10A005
NB Figures quoted for sound insulation refer to room-to-room tests to BS EN 20140-9. Where higher levels are required other design considerations can be
adopted, such as extending partitions into the ceiling void or installing a plenum barrier.
Design
Planning - key factors
Ceilings should be set out from the centre to give balanced
widths of tiles at the perimeter. A number of grid layouts are
possible, depending on the grid selected and the choice of
ceiling tile or plank.
See Construction details – 1 - 8 for alternative configurations.
Designers and installers should take due regard of EN 13964,
suspended ceiling - requirements and test methods.
NB
Relative humidity (RH)
The grid is suitable for use in occupied buildings in conditions
up to 90% relative humidity (RH90). However, Gyptone tiles
and planks are only suitable up to RH70.
Cavity barriers
Where cavity barriers are required, they can be formed using
Gyproc FireStop screw-fixed to a simple metal frame. The
framing should be fixed to the structure to avoid undue
loading of the ceiling suspension grid. The bottom of the
framework should be fixed to the ceiling grid.
Fire-stopping
It is necessary to provide suitable non-combustible
fire-stopping material at the junction of a cavity barrier with
the structural perimeter and the ceiling. Fire-stopping must
also be provided around any service penetrations through the
cavity barrier.
Fixtures
Unperforated Gyptone ceiling tiles will support a point load
of up to 3kg / tile for maximum 2mm deflection (1kg / tile for
D2 edge tiles). This will normally allow items such as
spotlights and down-lighters to be installed without the
need for a support pattress. A support pattress should,
however, be installed where the prevailing environmental
conditions exceed 25°C and RH70, or where the size of the
cut-out required is greater than 150mm diameter or 150mm
square. Perforated tiles should not be used to support
fixtures. Apertures for spotlights and down-lighters can be
cut into Gyptone ceiling tiles using a circular tank cutter on a
power drill or using a pad saw.
190
The Gyptone T24D2 grid should not be point-loaded with
more than 1kg between points of suspension. Distributed
loads may be max. 2kg/m of section. Built-in light fittings
that are placed between grid sections are suspended
separately.
Gyptone plank installed in the Gyptone TI5 grid must not be
loaded. Light fittings and other fixtures should be
independently supported. If mineral wool is placed above the
ceiling, the maximum self-supporting distance is reduced to
1800mm. Hangers should be used for increased spans
Services
The ceiling void above the suspension grid can be used to
route all service requirements including ducting, pipework,
electrical cables, and conduits. Ducting, ventilation units, etc,
must be independently supported from the structure.
Maintenance
Ceiling tiles and planks can be cleaned using a damp cloth or
soft brush. Most standard mild detergents can be used. Tiles
can be re-decorated if required using a suitable emulsion
paint and a short-haired brush or roller (spray painting will
impair sound absorption).
Gyptone tiles with Activ’Air
Though we don’t notice them, impurities are often present in
the air we breathe – emitted from furniture, carpets and
building materials. Long-term exposure to these can
potentially cause health problems and reduce general
wellbeing.
Clean air, on the other hand, can speed up patient recovery in
hospitals, reduce absence at work, and increase pupils’
concentration at school.
Activ‘Air is our latest innovative technology that improves
indoor air quality by permanently removing formaldehyde
circulating indoors. Formaldehyde concentration will be
reduced by 70% when 1m2 of Activ’Air is installed per m3.
www.gyproc.ae
Construction Details
1
2
15mm and 24mm exposed lay-in grid with interlocking Main and Cross ‘T’s
- for square edge A and regular edge E15 and edge E24
Gyptone GRID
6
5
1
B , C or E
D
2
7
A
3
4
A
Square edge
A
Tegular edge
T24 grid-cross section
T15 grid-cross section
7
B
1
2
3
4
Gyptone Main ‘T’
Gyptone Cross ‘T’ 1200mm
Gyptone Wall Angle
Gyptone Shadow Angle
C
D
E
5 Suspension wire (by others)
6 Gypframe Soffit Cleat
7 Gyptone Cross ‘T’ 600mm
www.gyproc.ae
191
Construction Details
2
2
Gyptone 15mm and 24mm exposed lay-in grid with interlocking Main and Cross ‘T’s
- for square edge A and regular edge E15 and edge E24
Gyptone GRID
1
x
x
2
Layout 1
Gyptone Tiles 600mm x 600mm (modular dimensions)
Gyptone Main ‘T’ at 1200mm centres
Gyptone Hangers at 1200mm centres
4
x
x
3
1
1
x
x
4
Layout 2
x
x
Gyptone Tiles 600mm x 600mm (modular dimensions)
Gyptone Main ‘T’ at 600mm centres
Gyptone Hangers at 1200mm centres
1
x
x
3
1
1 Gyptone Main ‘T’ section
2 Gyptone Cross ‘T’ section 1200mm
NB
192
3 Hanger shown as ‘x’
4 Gyptone Cross ‘T’ section 600mm
These details are for illustrative purposes only. Precise details will vary according to the proprietary grid system used.
www.gyproc.ae
Construction Details
Installation of API Cross-Lock Unipro and Gyptone D2 edge tiles
m
300 m
Gyptone GRID
3
B
A
The placement of the wall angle should be marked with a
bubble level/chalk line and mounted with a flatheaded screw
suitable for the foundation per max. 300 mm, the first screw
one no more than 50 mm from a corner. The wall angle should
not be shorter than 300 mm. Cut the profiles in close mitre
at the corner joint. If the foundation is uneven mount a thin
wooden list behind the wall angle.
C
Hangers for the main beams should be placed in rows per
1200 mm. The first main beam max. 300 mm from the wall.
First hanger in main beam max. 300 mm. from the wall. The
other hangers per max. 1200 mm. See page 195. The hook of
the hanger is squeezed together with a pair of Pliers. The
hangers should be adjusted, so the main beam is elevated
44 mm above the wall angle.
D
At the longitudinal assembly of the main beams the couplings
should be pushed together until they click.
E
The cross-lock connectors are to be placed with a center
distance of 600 mm on the main beam (maximum 600 mm
from the wall). The tap in the connector should aligned with
the vertically slot in the main beam. The connectors should
be pushed down on the main beam until they click.
F
Connect the cross profile to the main beam, by twisting the
cross profile onto the cross-lock connector. This is done by
placing the legs of the connector into the dedicated cut-outs
on the cross profile.
For safety and for a stabile connection between the main
beam and the cross profile, fold the locking mechanism on
the cross lock connector with a pair of Pliers.
www.gyproc.ae
193
Construction Details
Gyptone GRID
Installation of API Cross-Lock Unipro and Gyptone D2 edge tiles (continued)
6 mm
G
H
Make final adjustments to the grid system, to make sure that
the cross profiles is elevated 6 mm above the wall angle, like
seen in the lower right corner.
This means that the cross profiles and main beams are located
above the wall angle. Ones the grid system is adjusted, every
second main beam should be connected to the wall with a
connecting bracket. This is due to better stability in the grid
system.
E
GYPTON
I
J
When installing the Gyptone edge D2, use cotton gloves.
Lift one side of the tile, the E edge, up above the cross profile.
Then slide the opposite side of the tile, the D2 edge, into the
opposite cross profile. When the tile is mounted in the grid
system, it can be slide into place. Be careful not to damage
the tiles during installation. All tiles a demountable after
installation. All installations should be finished before
mounting the D2 tiles. Always start in the center of the room,
when laying the tiles into the grid system.
K
L
The last tile against the wall, should be cut into size with either
a saw or a knife. It is important to protect the front side of the
tile, to avoid any damage to the painted surface. The tiles
should not be cut with an undersized of more than max. 5 mm.
194
When mounting the last tile against the wall, place 2 wall
springs for each tile. The short side of the spring is squeezed
down between the wall angle and the wall. The wall springs
is installed before the last tiles are laid into the grid system.
Gyptone edge D2 installed in concealed Cross-Lock Unipro
24 mm grid system.
www.gyproc.ae
Construction Details
2
Gyptone T24D2 concealed grid system consisting of interlocking Main ‘T’s and Cross ‘T’ spacers
- for concealed / demountable edge Gyptone D2 edge tiles
Distance to 1. cross profile X + 24 mm
Gyptone GRID
4
Distance to 1. cross profile X
Frieze width Y
Frieze width Y
12 mm
3
Max
300 mm
2
1
Max
1200 mm
6
5
4
Max
300 mm
Max 1200 mm
600 mm
6
4
3
2
1
5
38
15
1
2
3
4
Main beam unipro
Cross profile unipro
Wall angle
Cross Lock connector
Grid system
Dimension på T-24
grid system
38
24
5 Adjustable hangers
6 Connecting bracket
7 Wall springs
www.gyproc.ae
195
Construction Details
5
Installation of API grid system and Gyptone Xtensiv
m
Gyptone GRID
300 m
A
B
The placement of the shadow moulding is marked with a
bubble level/chalk line and mounted with a flatheaded screw
suitable for the foundation per max. 300 mm, the first one
no more than 50 mm from a corner. The shadow mouldings
should not be shorter than 300 mm. Cut the profiles in close
mitre at the corner joint. If the foundation is uneven mount a
thin wooden list behind the wall angle.
C
D
At the longitudinal assembly of the main beams the couplings
should be pushed together until they click
E
The cross lock connectors are to be placed with a centre
distance of 300 mm on the main beam. The tap in the connector should aligned with the vertically slot in the main beam.
The connectors should be pushed down on the main beam
until they click.
F
Connect the cross profile to the main beam, by twisting the
cross profile onto the cross connector. This is done by placing
the legs of the connector into the dedicated cut-outs on the
cross profile.
196
Hangers for the main beams are placed in rows per 1200 mm.
The first main beam max. 300 mm from the wall. First hanger
in main beam max. 300 from the wall. The other hangers per
max. 1200 mm. See the illustration to the right. The hook of
the hanger is squeezed together with a pair of nippers.
For safety and for a stabile connection between the main
beam and the cross profile, fold the locking mechanism on
the cross lock connector with a pair of nippers.
www.gyproc.ae
Construction Details
G
Gyptone GRID
Installation of API grid system and Gyptone Xtensiv (continued)
H
Adjust the entire grid system, so the cross profiles is laying on
the top step of the shadow moulding, like seen in the lower
right corner. This means that the main profiles are located
above the shadow moulding. Ones the grid system is adjusted,
every second main beam should be connected to the wall for
stability. This is done with an connecting bracket.
I
When installing the Gyptone Xtensiv, use cotton gloves. Lift
one side of the Xtensiv up above the grid system. Then there is
enough space to lift the other side of the Xtensiv up, laying it
in place on the opposite cross profile. All installations should
be finished before mounting the Xtensiv plates.
J
It is possible to slide the Xtensiv along the cross profiles, ones
it is in place in the grid system. This is needed when installing
the Xtensiv plates in the perimeter of the room.
K
Gyptone Xtensiv can be shortened with a knife. It is possible
to shorten the Xtensiv by cutting in the perforated area, if it is
necessary. It is not recommended to cut in the perforated area
of an Xtensiv Line, as cutting into the Line perforation will
weaken the Xtensiv.
L
In case lighting fittings are planned, supporting profiles have
to be mounted using the light fitting XT. This bracket is needed
to give the Xtensiv ceiling the same visual appearance regarding
the light installation, as the photo on the front page of the
installation manual. The position of the brackets is related of
the light fitting and ceiling layout. The light fitting XT needs
to be secured with Gyproc Wafer Head Screws. To support the
cut in the main beam, place a hanger near the light fitting XT.
It is also possible to make a 600x600 mm recess, for a light
fitting in the Xtensiv ceiling system. The method is shown on
page 198. Page 198 shows the 2 possible connections
between the cross profile and the cross tee. In case of a square
recess in the Xtensiv ceiling, the recess should be placed between the main profiles and not under the main profiles.
www.gyproc.ae
197
Construction Details
6
Gyptone Xtensiv
3
Max
300 mm
2
Gyptone GRID
1
Max
1200 mm
6
5
4
Max
300 mm
Max 1200 mm
Max 300 mm
How to make a 600x600 mm recess in an Xtensiv ceiling
8
6
How to connect Cross Tee and Cross Profile, when making a recess in the Cross Lock system
Option 1
1
2
3
4
198
Main beam unipro
Cross profile unipro
Shadow moulding
Cross Lock connector
Option 2
5
6
7
8
Adjustable hangers
Connecting bracket
Light fitting XT
Cross profile
www.gyproc.ae
Construction Details
7
2
Gyptone T15 exposed metal grid fixing system - for Gyptone plank, edge E15/A
A
Gyptone GRID
2
1
B
A
C
3
(See example layouts on page 200)
1 Gyptone Main ‘T’ section
2 Gyptone Plank edge profile
3 Gyproc Wafer Head Jack-Point Screws at 300mm centres
www.gyproc.ae
199
Construction Details
8
2
Gyptone T15 exposed metal grid fixing system - for Gyptone plank, edge E/A
2
Gyptone GRID
1
Layout 1 - Corridor
Planks 300mm x 1800mm (modular dimensions)
2
Layout 2 - Corridor corners
300
600
x
C
600
x
300
Dimensions in mm
x
3
B
B
Layout 3 - Alcoves
300 600
x
C
x
x
Dimensions in mm
x
x
3
B
1 Gyptone Main ‘T’ section
2 Gyptone Plank edge profile
200
3 Hanger shown as ‘x’
www.gyproc.ae
Gyptone GRID
Notes
www.gyproc.ae
201
Download