EDGE ET6R
LUMINOUS GEOMETRYTM
LED Recessed Linear with
Regress Lens
Project Name
Date
Catalog Number
Type
CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflective
die-formed white painted steel reflector, .125” diffuse snap-in acrylic lens with matte finish, removable for lamp
replacement.
ELECTRICAL Electronic, 120 to 277 volt input and 24V output, drive current not to exceed 350ma. 0-10 volt dimming
5-3/4”
standard.
LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80.
R9≥20, CRI≥80 and L70 (6K)=50,000 hours (IES TM-21)
MOUNTING Edge Techx is designed for use with Armstrong® TechZone™ and USG Logix™ Integrated Ceiling Sys-
tems. Consult factory for detailed installation instructions or for use in conventional grid ceiling systems.
5”
FINISH Standard powder-coat textured white painted finish on exposed trim, consult factory for custom colors.
6”
WARRANTY Edge LED offered with a 5-year limited warranty. Covers LED, driver and fixture.
LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted.
For use with Armstro n g ® Te c h Z o n e TM and
USG LogixTM Integrated Ceiling Systems
YEAR LED
WARRANTY
LFL
Convertible
LED
5-3/4”
YEAR LED
WARRANTY
LED
LFL
LED
Convertible
Convertible
LFL
Convertible
LED
LFL
5”
6”
L U M I N A I R E S P E C I F I C AT I O N
Sample Catalog #: ET6R-30-24’-G1-120-1C-W
ET6R-
____-
___’-
___-
___-
HOUSING
COLOR/LUMENS
LENGTH
MOUNTING
VOLTAGE
LFL
ET6R- Edge
Techx 6, Regress
Lens
30K Color Temperature Lumen Options
30- 30K, 500 lumens/ft (7.10watts/ft)
30HO- 30K, 875 lumens/ft (12.6watts/ft)
35K Color Temperature Lumen Options
35- 35K, 500 lumen/ft (7.10watts/ft)
35HO- 35K 875 lumens/ft (12.6watts/ft)
40K Color Temperature Lumen Options
40- 40K, 500 lumens/ft (7.10watts/ft)
40HO- 40K, 875 lumens/ft (12.6watts/ft)
Individual Units2
2- 2’, 23” fixture2
3- 3’, 35” fixture2
4- 4’, 47” fixture2
5- 5’, 59” fixture2
6- 6’, 71” fixture2
8- 8’, 95” fixture2
Continuous Runs3
xx’- Specify row length to 1’ increments
__-
YEAR LED
WARRANTY
1
Convertible
120- 120 V LED
277- 277 V
UNV- UNV5
(120/277)
CIRCUITING
LED
5-3/4”
Convertible
LFL
1C- Single Circuit
1D- Single Circuit Dimming4
1B- Single Circuit with
Remote Battery Pack4,5
SYS- EcoSystem® Dimming4
__-
____
FINISH
OPTIONS
W- Matte
White
CC- Custom
Color
5”
6”
Individual Units (CANNOT BE JOINED)2
Acoustical Grid Ceiling
G1G- 1” Ceiling Grid
G9G- 9/16” Ceiling Grid
GSG- Screw Slot Ceiling Grid
Continuous Runs (JOINABLE)3
Acoustical Grid Ceiling
G1- 1” Ceiling Grid
G9- 9/16” Ceiling Grid
GS- Screw Slot Ceiling Grid
CPMRFLMRFXLEDMRALMRADSMDSS-
Chicago Plenum
Fixed MR16 Halogen6
Fixed MR16 LED6
Fixed Xicato LED6
Adjustable MR16 Halogen6
Adjustable MR16 LED6
Daylight Sensor Master6,7
Daylight Sensor Satellite6,7
See back page for mounting detail. 2Individual units cannot be joined. All end trims are factory installed and cannot be removed in the field. 3Continuous Rows made up of both even and odd length
fixtures. Designed to fall on-grid. 4Some Edge configurations will not accommodate all electrical options. Consult factory. 5Integral battery packs with remote test switch are provided with 1B option. 6See
back page for configurations using MR16 units, daylight sensor and solid spacers. 7Daylight sensor requires 0-10 volt dimming ballast.
1
®
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2013 Pinnacle Architectural Lighting® May 2013
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
EDGE TECHX
INDIVIDUAL AND CONTINUOUS RUN MODULES 1
Side Views
48”, 72”, 96”
59”
23"
23”, 35”, 47”, 71”, 95”
5'
2'
(1) lens per 2' unit
(1) lens per 5' unit
35"
71” or 72”
6'
3'
(1) lens per 3' unit
(1) lens per 6' unit
47” or 48”
95” or 96”
8'
4'
(1) lens ET3H
per 4' unit
ET3A,
(1) lens per 8' unit
1Acoustical Grid Ceiling available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings.
CONFIGURATION OPTIONS
MR16 Standard Layouts
5-1/2"
Blanks Standard Layouts
5-1/2"
24"
5-1/2"
M2M
2'
5-1/2"
M2M2M
5-1/2"
5-1/2"
48"
12"
5-1/2"
Side Views
48”, 72”, 96”
5-1/2"
36"
5-1/2"
36"
12"
36"
5-1/2"
(1) louver per 4' unit
M3M3M
5-1/2"
N3N3N
5-1/2"
12"
5-1/2"
24"
5-1/2"
(2) louvers per 6' unit
5-1/2"
48"
71” or 72” D4N
6'
24"
N2N2N
47” or 48”
5-1/2"
5-1/2"
48"
5-1/2"
36"
23”, 35”, 47”, 71”, 95”
D3N
5-1/2"
5-1/2"
24"
5-1/2"
24"
D2N
N4N
24"
(1) louver per 3' unit
4'
5-1/2"
N3N
35"
M4M
5-1/2"
36"
23"
5-1/2"
(1) louver
per 2' unit
3'
24"
N2N
5-1/2"
M3M
Daylight Sensor Standard Layouts
5-1/2"
24"
12"
5-1/2"
24"
D2N2N
95” or 96”
8'
12"
36"
36"
(2) louvers per 8' unit
5-1/2"
5-1/2"
36"
12"
5-1/2"
36"
D3N3N
1Acoustical Grid Ceiling vailable as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings.
MOUNTING DETAILS
1” Grid Mounting Options
9/16” Grid Mounting Options
Screw Slot Mounting
1” Grid, Standard Tile:
1” Grid, Tegular Tile:
Specify G1 or G1G in part # Specify G1 or G1G in part #
9/16” Grid, Tegular Tile:
9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile:
Specify G9 or G9G in part # Specify G9 or G9G in part # Specify GS or GSG in part #
Screw Slot Grid:
Specify GS or GSG in part #
MR16 LAMPS
APPLICATION: MR16’s are ideal for conference rooms,
corridors,
wall washing, retailSpackle
spaces and
training facilNon-Flange
Flange
ities where accent lighting is required.
TECHNICAL: MR16 fully enclosed compartment eliminates light from entering into other fixture areas. Available in 20, 35 and 50 watt halogen lamps, 4 and 8 watt
LED lamps. (lamps not included). Consult factory for
other lamp types. Select from an adjustable or fixed unit.
ELECTRICAL: Standard 50 watt max halogen lamp transformer (120v or 277v),
60 watt max LED electronic transformer (120v only). MR16 installed as independent
circuit.
MR16
voltage to
match
voltage. Drywall, Flangeless Look:
Exposed
Flange
Detail:
Metal
PanLED
or Millwork:
Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part #
Flange Detail
®
LABELS: UL and cUL Listed, approved for dry/damp location unless othMount
Rotating Crossbar
erwise Perimeter
noted.
ORDERING INFORMATION: Specify MR16 layout and lens in the
options section of the part number. Sample Catalog #: ET6R-30-4G1-120-1C-W-M4M. See MR16 Resource Guide for Layout and Lens
Options.
Drywall, Flangeless Look:
Specify SF or SFS in part #
Unavailable Structure Support:
Specify RC in part #
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2013 Pinnacle Architectural Lighting® May 2013
Grid Mounting
Options
9/16” Grid Mounting
Options
Mounting
Specifications and1”
dimensions
subject to change
without notice. Specification sheets that appear on pinnacle-ltg.com
are the most recent
version and supersede all other previouslyScrew
printed orSlot
electronic
versions.
Download