EDGE EV6D
E V O L U T I O N
LED Recessed Linear with
Diffuse Articulated Lens
1”
5” (127mm)
Project Name
Grid: 5-13/16”
(147.6mm)
FL: 6-1/8” (155.6mm)
(25.4mm)
Date
5” (127mm)
Grid: 5-13/16” (147.6mm)
FL: 6-1/8” (155.6mm)
Catalog Number
Type
CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflective
die-formed white painted steel reflector, single piece extruded diffuse acrylic lens with convex wings and articulated
center spine creating a fully luminous lens.
ELECTRICAL Electronic, 120 to 277 volt input and 36V5-3/4”
output. 0-10 volt dimming standard. Must specify 1D in circuiting
for dimming.
(146.1mm)
LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80.
R9≥20, 27K is CRI≥90, 30K, 35K, and 40K is CRI≥82. Minimum lifetime greater than 60,000 hours.
MOUNTING Edge is designed to install into acoustical grid and inaccessible ceilings. Specify GXG, FLF, SFS, NFN for
individual, unjoinable units (individual units will fall on-grid). Specify GX, FL, SF, NF for continuous runs (runs designed
to fall on-grid). Grid retention brackets
are integral to housing. Each housing contains 4 grid retention brackets. Consult
5” (127mm)
factory for detailed installation
instructions.
Grid: 5-13/16”
(147.6mm)
FINISH Standard powder-coat
textured
white, metallic silver, textured black, graphite or bronze painted finish, consult
FL: 6-1/8”
(155.6mm)
factory for chip of standard paint finishes. Contact factory for additional custom color and finish options.
WARRANTY Edge LED offered with a 5-year limited warranty. Covers LED, driver and fixture.
LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted.
YEAR LED
WARRANTY
LFL
Convertible
LED
YEAR LED
WARRANTY
LED
5-3/4”
(146.1mm)
LFL
LED
Convertible
Convertible
LFL
Convertible
LED
LFL
5” (127mm)
Grid: 5-13/16” (147.6mm)
FL: 6-1/8” (155.6mm)
L U M I N A I R E S P E C I F I C AT I O N
EV6
HOUSING
D_-
Sample Catalog #: EV6D-30-24’-FL-120-1C-W
____-
SHIELDING COLOR/LUMENS
1
___’-
___-
LENGTH
MOUNTING
___-
__-
__-
____
VOLTAGE
CIRCUITING
FINISH
OPTIONS
YEAR LED
WARRANTY
10
LFL
Individual Units2
2- 2’, 23” (584.2mm) fixture2
3- 3’, 35” (889mm) fixture2
4- 4’, 47” (1193.8mm) fixture2
5- 5’, 59” (1498.6mm) fixture2
6- 6’, 71” (1803.4mm) fixture2
8- 8’, 95” (2413mm) fixture2
Continuous Runs3
xx’- Specify row length to 1’ (304.8mm)
increments
EV6- Edge
Evolution 6
D- Diffuse Articulated Lens
DL- Diffuse Articulated Lens
with Linear Slot Insert
DM- Diffuse Articulated Lens
with Micro Conical Insert
DG- Diffuse Articulated Lens
with Grooved Insert
DR- Diffuse Articulated Lens 27K Color Temperature Lumen Options
27- 27K, 398 lumens/ft (5.2 watts/ft)
with Round Perf Insert
27HO- 27K, 744 lumens/ft (10.1 watts/ft)
30K Color Temperature Lumen Options
30- 30K, 485 lumens/ft (5.2 watts/ft)
30HO- 30K, 906 lumens/ft (10.1 watts/ft)
35K Color Temperature Lumen Options
35- 35K, 506 lumens/ft (5.2 watts/ft)
35HO- 35K, 946 lumens/ft (10.1 watts/ft)
Convertible
LED
120- 120 V
277- 277 V
UNV- UNV
(120-277)
LED
Convertible
LFL
1C- Single Circuit
1D- Single Circuit Dimming5
1B- Single Circuit with
Battery Pack5,6
1E- Single Circuit with
Emergency Circuit
Individual Units (CANNOT BE JOINED)2
Acoustical Grid Ceiling11
G1G- 1” (25.4mm) Ceiling Grid
G9G- 9/16” (14.3mm) Ceiling Grid
GBG- 9/16” (14.3mm) Ceiling Grid with Bevel Trim
GSG- Screw Slot Ceiling Grid
Inaccessible Ceiling
FLF- Standard 1/2” (12.7mm) Flange
SFS- Spackle Flange
NFN- Flangeless4
Continuous Runs (JOINABLE)3
Acoustical Grid Ceiling11
G1- 1” (25.4mm) Ceiling Grid
40K Color Temperature Lumen Options
G9- 9/16” (14.3mm) Ceiling Grid
40- 40K, 519 lumens/ft (5.2 watts/ft)
GB- 9/16” (14.3mm) Ceiling Grid with Bevel Trim
40HO- 40K, 970 lumens/ft (10.1 watts/ft)
GS- Screw Slot Ceiling Grid
Inaccessible Ceiling
Custom Output
CL_____- Specify color temp. and lumens/ft. (i.e. CL35600) FL- Standard 1/2” (12.7mm) Flange
CW____- Specify color temp. and wattage/ft. (i.e. CW407.5) SF- Spackle Flange
4
(Specify lumens/watts between standard offering listed above. NF- Flangeless
W- Matte White
S- Metallic Silver
BL- Textured Black
GR- Graphite
BR- Bronze
CC- Custom Color
CPMRFLMRFXLEDMRA-
Chicago Plenum
Fixed MR16 Halogen9
Fixed MR16 LED9
Fixed Xicato LED9
Adjustable MR16
Halogen9
LMRA Adjustable MR16 LED9
PM- Perimeter Mount7
RCRotating Crossbar8
Lumens are specified per color temp.)
Diode imaging will be apparent in Diffuse Lens 2Individual units cannot be joined. All end trims are factory installed and cannot be removed in the field. 3Continuous Rows made up of both even and odd
length fixtures. Designed to fall on-grid. 4NF and NFN to be utilized for metal pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Integral battery
packs with remote test switch are provided with 1B option. 7Available for acoustical grid ceilings. Wall rail painted white unless otherwise specified. 81/2” to 5/8” drywall thickness. Available for standard
1/2” flange (FL). 9Consult MR16 Resource Guide for configurations using MR16 units. 10See back page for mounting detail. 11 See page 3 for grid retention bracket details.
1
®
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting®
August 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
EDGE EVOLUTION
EV6C, EV6D
INDIVIDUAL AND CONTINUOUS RUN MODULES 1
23" (584.2mm)
59” (1498.6mm) or 60” (1524mm)
5'
2'
(1) lens per 2' unit
(1) lens per 5' unit
35" (889mm)
71” (1803.4mm) or 72” (1828.8mm)
6'
3'
(1) lens per 3' unit
(1) lens per 6' unit
47” (1193.8mm) or 48” (1219.2mm)
95” (2413mm) or 96” (2438.4mm)
4'
8'
(1) lens per 4' unit
(1) lens per 8' unit
1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings.
MOUNTING DETAILS
1” Grid Mounting Options
EV6A,
EV6H, EV6AL
9/16” Grid Mounting Options
23" (584.2mm)
Screw Slot
Mounting
59” (1498.6mm) or 60” (1524mm)
2'
5'
(1) lens per 2' unit
(1) lens per 5' unit
35" (889mm)
3'
71” (1803.4mm) or 72” (1828.8mm)
6'
lens per 3'
unit 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular
1” Grid,(1)
Standard
Tile:
Screw Slot Grid:
(1) lensTile:
per 6'9/16”
unit Grid, Tegular Tile: 9/16” Grid, Tegular Tile:
Use G1 or47”
G1G(1193.8mm)
in part # Use
G1 or
G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or95”
GBG
in part #orUse
or GSG in part # Use GS or GSG in part #
or 48”
(1219.2mm)
(2413mm)
96”GS
(2438.4mm)
8'
4'
INACCESSIBLE CEILING MOUNTING
SPECIALTY MOUNTS
(1) lens per 8' unit
(1) lens per 4' unit
1Acoustical
Perimeter
Mount
Flange
Detail
Non-Flange
Spackle
Grid Ceiling
and Inaccessible Ceilings
available as individual units or continuous
rows.Flange
Individual units and rows are available for
on-grid installation
with acoustical ceilings.
Rotating Crossbar
EV6P
Side Views
48”, 72”, 96”
23"
23”, 35”, 47”, 71”, 95”
2'
(1) louver per 2' unit
Exposed Flange
Metal Pan or Millwork:
Drywall, Flangeless Look:
35"Detail:
Specify
FL
or
FLF
in
part
#
Specify
NF
or
NFN
in
part
#
Specify
SF or SFS in part
6'#
3'
(1) louver per 3' unit
MR16 LAMP
4'
Unavailable Structure Support:
Specify RC in part #
Bracket
Wall Rail:
71”and
or 72”
Specify PM in part #
(2) louvers per 6' unit
47” or 48”APPLICATION: MR16’s are ideal for conference rooms,
corridors, wall washing, retail spaces and training
8' facilities where accent lighting is required.
ELECTRICAL: Standard
watt max halogen lamp transformer (120v
95” or5096”
or 277v), 60 watt max LED electronic transformer (120v or 277v). MR16
installed as independent circuit. MR16 voltage to match LED voltage.
(2) louvers per 8' unit
(1) louver per 4' unit
LABELS: UL and cUL Listed, approved for dry/damp location unless otherwise noted.
TECHNICAL:
MR16 fully enclosed compartment elimi1Acoustical Grid Ceiling and Inaccessible
Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings.
nates light from entering into other fixture areas. Available in 20, 35 and 50 watt halogen lamps, up to 12 watt
LED lamps (lamps not included). Consult factory for other lamp types/ wattages.
1” Grid Mounting Options
ORDERING INFORMATION:
MR16 layout guide.
9/16” Grid Mounting Options
MR16’s should be specified utilizing
Screw Slot
Mounting
1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile:
Screw Slot Grid:
Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part #
Flange Detail
Non-Flange
Spackle Flange
Metal Pan or Millwork:
Rotating Crossbar
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
®
Exposed Flange Detail:
Perimeter Mount
Drywall, Flangeless Look:
© 2016 PinnacleBracket
Architectural
Lighting®
August 2016
Unavailable Structure Support:
and Wall
Rail:
Specifyand
FL dimensions
or FLF in part
# to
Specify
RC in
# versions.
Specify
in part
#
Specify
or NFN
in Specification
part # Specify
SFthat
or SFS
in on
part
#
Specifications
subject
changeNF
without
notice.
sheets
appear
pinnacle-ltg.com
are the most
recentPM
version
and supersede
all other previously
printed
or part
electronic
GRID RETENTION BRACKET
EDGE EVOLUTION
Joint holes
Joint for
holes
#8-32
for #8-32
ScrewsScrews
GRID RETENTION: At every
joint, the addition of grid
retention brackets results in
a sturdy connection between
the fixtures and the grid.
Insert screws through the
bracket into the grid to
secure.
JOINT ALIGNMENT: Incorporating biscuits and screws
not only creates a secure
joint but also aids in fixture
alignment.
BiscuitBiscuit
®
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting®
August 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
Download