Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com SurgX... new Technology, new ESD Protection. ® Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www. Dear Web Browser: The following information describes the new line of Bussmann SurgX® ESD suppressors. This innovative approach to ESD suppression offers the circuit designer the advantages of low capacitance, low leakage current, high peak current capability and fast response, at a very competitive price. The “zero footprint” connector arrays also help you conserve valuable circuit board real estate. The Bussmann SurgX® manufacturing process is extremely flexible and lends itself to custom configurations. If you require a special configuration for a particular connector, application assistance, or samples for evaluation, please feel free to contact one of the following individuals. Ed Carter (314) 527-1613 Ernst Steinert (314) 527-1368 Steve Whitney (314) 527-1663 Application Engineering (314) 527-1270 Thank you for your interest in these exciting new products. We look forward to providing you with high performance, cost effective products to assist you in meeting the requirements of IEC 1000-4. Sincerely, Steve Whitney Manager, Product and Market Development Board Level Technology Products Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com ® SurgX ... new Technology, new ESD Today, more than ever, electron- combine a new polymer technol- ic design engineers are looking ogy with our expertise in metal for solid, reliable protection film on ceramic deposition. The against electrostatic discharge result—SurgX—provides Easily configured into custom packages. ■ “Zero Footprint” connector arrays. ■ Extremely fast response time. ■ Bi-directional. the (ESD). designer these outstanding bene- As the fits in ESD protection: micro- ■ electronic ■ Protection against high ESD voltages and currents. SurgX is ideal for high speed signal circuit applications where industry ■ Extremely low capacitance. ESD spikes can reach 45A @ moves ■ Very low leakage current. 15kV. It provides the designer toward ■ Zero signal distortion. with performance characteristics that exceed the values in IEC l o w e r 1000-4-2, the key international operating voltages, steadily standard increasing circuit speeds, f o r and higher IC densi- E S D t ie s , t h e re i s immunity. a definite requirement Bussmann, for the world leader ESD protection that is equally in circuit protection fast, small and reliable. SurgX products, devices, is proud to offer SurgX by to design engineers as the Bussmann, are tran- most cost-effective, advanced sient voltage sup- technology in board-level ESD pressors (TVS) protection. that “ 2 SurgX is ideal for high speed signal circuit applications ” Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Protection from Bussmann ESD and IEC 1000-4-2 Test Conditions IEC 1000-4-2 is widely recog- Testing Requirements nized as the “yard stick” for eval- All electronic equipment des- uating ESD immunity. SurgX Level Contact Discharge* Mode Test Voltage kV Air Discharge Mode Test Voltage kV tined for Europe must be able to 1 2 2 surpasses the stringent require- withstand ten (10) strikes of a 2 4 4 ments of this international stan- simulated ESD waveform with tr 3 6 8 dard, in addition to meeting the <1ns in contact discharge mode 4 8 15 requirements of MIL-STD-883C, (preferred) at pre-selected points and S5.1 accessible during normal main- (Human Body Model) and S5.2 tenance or usage. Testing must (Machine Model). be performed at one or more of IEC 1000-4 four (4) severity levels, depend- IEC 1000-4 is a series of specifi- ing on the appropriate equip- cations, written and mandated ment category. by Waveform Parameters ESD the Association International Electrotechnical Commission *Preferred mode of testing due to its repeatability. Level Test Voltage Level kV First Peak of Discharge Current Amps +-10% tr (ns) 30 ns Current Amps +- 30% 60 ns Current Amps +-30% for electronic equipment. IEC 1 2 7.5 0.7 - 1 4 2 1000-4-2 is the specific standard 2 4 15 0.7 - 1 8 4 relating to ESD. The IEC 1000-4 3 6 22.5 0.7 - 1 12 6 standards were deemed neces- 4 8 30 0.7 - 1 16 8 (IEC), which defines electromagnetic compatibility requirements sary by the regulatory agencies within the European Union. These EU standards are expected In establishing IEC 1000-4, the International Electrotechnical recognized pleted, the equipment must not experience to be adopted worldwide. Commission When the test has been com- the growing presence of electromagnetic interference (EMI) in a world of systems and semicon- any permanent damage or upset (data or processing errors). The waveforms are to be injected at or along the equipment body which is accessible in normal set-up and operation. ductors that are more susceptible to the damaging effect of transient currents and voltages. 3 Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com The Unique Benefits of SurgX ® Response Time <1 nanosecond Few factors are as important as the time SurgX takes to respond to the overvoltage of ESD; that is, the time it takes SurgX to switch from an insulating state to a conductive state. Less than one nanosecond! (Fig. 1) Because of this incredible response time, SurgX limits the voltage more effectively than gas tubes, MOVs and most diodes. This means SurgX minimizes Fig. 1 Generalized V-I Waveforms Prospective Voltage Trigger Voltage the time that sensitive ICs are subjected to ESD overvoltage; almost instantly, it limits voltage to the clamping level. With SurgX, instrument circuits and sensitive components Voltage Across TVS are protected faster and with less overvoltage exposure. Clamp Voltage Clamp Voltage <60V This is the voltage across the device after it has trigCurrent Through TVS Peak Current gered (Fig 1). The lower the clamping voltage—the closer it is to normal operating voltage—the better. SurgX clamping voltage can be selected as low as 60V. This value is ideal for equipment operating at low voltages. It means less stress during the clamp period, and greater IC protection. Initiation of ESD Event TVS Triggers Bi-Directional SurgX responds to ESD pulses of either polarity in a circuit. This eliminates the need for back-to-back protection required with uni-directional devices. (Fig. 2) This saves board space and the added cost of a second uni-directional diode. Fig. 2 Bi-Directional vs Uni-Directional Bi-Directional 4 Uni-Directional “ Few factors are as important as the time SurgX takes to respond to the overvoltage ” In normal operating conditions, SurgX is virtually invisible to the cir- Fig. 3 Effects of Capacitance cuit. (Fig. 3) Installed from signal line to ground, SurgX exhibits a 6 high impedance and low capacitance (<1pF @ 1 MHz) that makes it 5 transparent to high speed digital circuits. Signals are not distorted or 4 disrupted. With SurgX, waveform definition stays true, and high speed input signals do not suffer. VOLTS Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Zero Signal Distortion SurgX Baseline 3 10V Diode 2 Varistor 1 0 “Zero Footprint” 0 1 2 3 4 5 6 TIME (ns) 7 8 9 10 The most attractive application of SurgX is on multiple line connectors carrying signals to and from a piece of equipment. Arrays installed between the connector and the circuit board—ahead of all ICs—SurgX frees-up valuable board space normally earmarked for discrete protective devices. SurgX makes more “real estate” available to board designers, allowing them to reduce board size or add more circuits and functions. High Peak Current Capability Recent research indicates that ESD overvoltage exceeds previously established values for both human body and machine models. ESD overvoltage can range from <1kV to 15kV. Some suppressors for ESD handle overvoltages up to 12kV. SurgX is rated 15kV at 45A. 5 Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com ® What is SurgX and How Does It Work? SurgX is conformally coated with polyurethane. The completed array is ready for solder attachment to an RJ-11 connector. • • • • • • Ground Pad A metalization is applied to reconnect the ground electrode to the ground pad. • • Connector pin holes are punched in “green” ceramic tape which is then fired. • • SurgX products are designed around a new technology in voltage-variable polymers. The unique properties of this new class of polymers are particularly applicable to ESD protection. In a connector array application (Fig. 4) SurgX is placed across a signal line leading to an integrated SurgX voltagecircuit and ground. The device variable polymer is deposited in exhibits minimal capacitance the micro-grooves. (<lpF) and is invisible to the circuit End view: Cross section during normal SurgX Signal Line operation. Signal Line Electrode Electrode E a c h Signal Line Electrode signal pin (1 of 5) electrode Ground Ground Electrode contacts Electrode the SurgX Substrate Micro-grooves material which are formed, forms a path to the ground pin. separating the signal line Under normal operating voltages and ground (typically 3 to 15V), the high electrodes. impedance of SurgX insulates each signal pin from ground. However, when an ESD event occurs, the unique polymer material rapidly switches (<l nanosecCoplanar electrode metalization is ond) to a conductive state when deposited on the the trigger voltage is reached. The top side of the voltage across the signal line colsubstrate. lapses to the clamping level, and Ag/Pd solder pads current is shunted through SurgX are deposited on to ground. When the overvoltage the bottom side of the substrate and event ends, the circuit returns to the metalization is its normal operating state as “pulled through” SurgX switches to high resistance the hole to provide a conductive via to and “invisibility.” the top side. Fig. 4 Signal Line In SurgX ESD suppressors by Bussmann utilize proven metal film on ceramic deposition techniques and an advanced voltage-variable polymer technology. The coplanar electrode design results in a low capacitance, high performance solution to ESD protection. Supply Voltage Normal Current Signal Line Out Normal Current IC Chip ESD TVS ESD TVS Current flow under surge conditions 6 Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Specifications and Performance Performance Comparison SurgX is a circuit protection device, exclusively designed for the fast, transient overvoltages associated with ESD*. Its function is similar to that of a gas discharge tube. These devices display one basic characteristic: when a sufficient overvoltage occurs they exhibit a dramatic increase in their ability to conduct electrons. The difference is performance. SurgX, as shown in Table I, simply out-performs other ESD protective devices. In addition to its outstanding performance, it should be noted that SurgX, can be configured as “zero footprint” arrays, thus freeing-up valuable circuit board “real estate.” Table I Performance Comparison Substrate: Ceramic ■ Electrodes: Silver-palladium ■ End termination finish: Nickel barrier (3.88 -4.3µm), followed by 90/10 tin - lead (5.1 - 10.2µm), surface mount packages only ■ ESD barrier: SurgX polymeric material ■ Encapsulant: polyurethane Environmental Specifications Dry heat: 96 hours @ 85oC ■ Humidity: 96 hours @ 85% RH, 60oC ■ Thermal shock: -55oC to 85oC, 1 hour cycle, 10 cycles ■ Vibration: MIL-STD202, Method 204, Test Condition C, (55 to 2000 Hz, 10Gs) ■ Solderability: withstands 60 seconds above 200oC; 260oC maximum ■ Solder leach resistance and terminal adhesion per EIA-576 ■ Custom Arrays Response Time (10-9 seconds) Gas Tube 500-5000 50-250 1-4 10-12 NO Diode <1 10-600 50-1000 10-4 NO MOV 1-30 6-200 400-1000 10-6 NO SurgX <1 40-120 <1 10-10 YES (Signal Line to Common) TYPE A General Purpose TYPE B Telecom Continuous Operating Voltage 24VDC 60VDC 40V typical 60V max. 150V typical 300V max. 80V typical 120V max. 300V typical 450V max. 1pF max. 1pF max. 100pA typical 100pA typical Peak Current2,3 45A maximum 45A maximum ESD Withstand2 500 pulses minimum 500 pulses minimum Electrical Characteristics Clamping Voltage2,3 Mechanical Specifications ■ Leakage Clamping Capacitance Voltage (V) (pF) @1 MHz. Current (A) Device Trigger Voltage2 Capacitance4 Leakage Current5 1. Voltages are peak to peak, unless noted otherwise. 4. Measured @ 1MHz. 2. Per IEC 1000-4-2, 15kV @ 45A, direct discharge. 5. Measured at rated continuous operat3. Measurement made 30ns after initiation of pulse. ing voltage. *SurgX is not intended for protection against lightning transients, or continuous overvoltages, nor is it intended for “production floor” ESD problems. 7 Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Standard Outlines Standard Surface Mount Outlines Dimensions: mm (inches) Outline Designation: SOT23 Outline Designation: 3216 3 2.80 (.110) 1.30 ±.10 (.051 ±.004) 3.20 ±.20 (.126 ±.008) Equivalent Circuit 1 1.90 ±.10 (.075 ±.004) 2 0.56 (.022) 3 1.60 (.063) 4.30 ±.10 (.169 ±.004) .51 ±.25 (.020 ±.010) 1.49 (.059) 0.55 (.022) 2.20 (.087) Recommended Land Pattern 0.55 (.022) 1.60 ±.20 (.063 ±.008) 1 0.30 (.012) 2 0.56 (.022) 1.90 (.075) 2.98 (.117) 1.09 ± .25 .10 ) (.043 ±.010 .004 ) 2.20 (.087) 1.40 (.055) 1.09 ± .25 .10 ) (.043 ±.010 .004) 0.90 ±.10 (.035 ±.004) 0.95 (.037) Recommended Land Pattern Outline Designation: 8X Outline Designation: 3X 4.00 (.157) 9 7 6 7.00 (.276) 3.50 (.138) 3.10 (.122) 4 .38 (.015) 1 2 0.40 (.016) 1 2 2.30 (.091) 3 2.10 (.083) 5 (0.50 .020) 10 4.50 (.177) .40 (.016) 8 3 0.80 (.031) 4 0.30 (.012) 4 .80 (.031) Equivalent Circuit 4.60 (.181) 1 2 .25 1.09± .10 .010 (.043± .004 ) 3 1.09 ±.25 .10 (.043 ±.010 .004 ) 0.40 (.016) 3.10 (.122) 1.50 (.059) 1.10 (.043) 3.50 (.138) 2.20 (.087) 0.40 (.016) 1.10 (.043) 0.51 (.020) 4.50 6.70 (.177) (.264) 2.20 (.087) 1.10 (.043) .80 (.031) 0.36 (.014) 3.86 (.152) 2.30 (.091) Recommended Land Pattern 0.80 (.031) 4.60 (.181) Equivalent Circuit 9 For the most recent product data, call Bussmann Information Fax: 314.527.1450 and request Document #3602. 8 0.56 (.022) 0.58 (.023) 1.91 (.075) 0.56 (.022) 0.35 (.014) 7 6 10 5 1 0.45 (.018) 8 2 3 4 Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Standard Connector Array Outlines Dimensions: mm (inches) 19 18 17 16 15 Outline Designation: DSUB37 0.89 (.035) DIA.HOLE TYPICAL 37 Outline Designation: DSUB9 GROUND ELECTRODE CONNECTION 54.91 (2.162) 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0.89 (.035) DIA.HOLE TYPICAL 9 5 8.36 (.329) 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 GROUND ELECTRODE CONNECTION 13.61 (.536) 4 3 2 1 5.38 (.212) 20 1.09 ± .25 .10 ) (.043 ±.010 .004) 1.78 (.070) TYPICAL 37 1.38 (.0545) 9 8 7 2.84 (.112) 1.09 ± .25 .10 ) (.043 ±.010 .004 ) 6 2.74 (.108) 1.78 DIA. (.070) TYPICAL 9 1.32 (.052) 2.54 (.100) 2.84 (.112) 2.77 (.109) 2.77 (.109) 1 2 1.37 (.054) 19 1.27 (.050) Equivalent Circuit 20 21 1 2 3 Equivalent Circuit Outline Designation: DSUB25 GROUND ELECTRODE CONNECTION DIA.HOLE TYPICAL 25 12 11 10 9 8 7 6 5 4 3 24 23 22 21 20 19 18 17 16 2 15 8 8.43 (.332) 0.89 (.035) DIA.HOLE TYPICAL 6 3 9 GROUND ELECTRODE CONNECTION 2 1 6.15 (.242) 1 8.36 (.329) 25 7 Outline Designation: RJ11 38.30 (1.508) 13 5 37 6 0.89 (.035) 4 6 5 4 14 1.09 ± .25 .10 ) (.043 ±.010 .004) 1.09 ± .25 .10 ) (.043 ±.010 .004) 2.03 (.080) 1.78 (.070) TYPICAL 25 1.38 (.0545) 1.68 (.066) 1.52 DIA. (.060) TYPICAL 6 2.84 (.112) 2.54 (.100) 2.54 (.100) 2.77 (.109) 2.77 (.109) 1 2 1.02 (.040) 1.24 (.049) 1 13 2 3 Equivalent Circuit 14 15 25 Equivalent Circuit 4 5 6 9 Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Application SurgX is applicable to most signal line circuits. It is applied as a surface mount device, or as an array between the circuit board and connector. SurgX is not applicable on lines where lightning or load switching transients are present. TYPE A SurgX is ideal for computers and computer-related equipment, such as modems, keyboards and printers. It is also applicable in telecommunications equipment where ringing signals are not present. TYPE B SurgX is designed for telecommunications equipment where ringing signals are present. High Frequency Instrumentation Data Bus In From Peripheral Device Bussmann 8X Surface Mount Array To Logic Circuitry High Frequency Signal Input High Frequency Preamplifier Driver/ Receiver IC Out Out To Peripheral Device From Logic Circuitry Universal Serial Bus Protection Ferrite Bead USB Port V BUS Power Management and USB ICs D+ D- 3 2 Bussmann SurgX 3X-ESD-A 1 Gnd Ferrite Bead 4 “ 10 SurgX is applicable in telecommunications equipment ... ” Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com How To Order -ESDTrigger Voltage: (See page 7) A = Type A General Purpose 150V Trigger B = Type B Telecom 300V Trigger Outline Designation: (See pages 8-9) Packaging: TR1/= 3,000 pcs, TP1/= 500 pcs, tape and reel (surface mount versions only) Eg. TR1/3216-ESD-A Custom Configurations The coplanar approach used by Bussmann to produce SurgX ESD suppressors is an SP1/= 10 pcs, tray pack (connector array versions only) Connector Array Surface Mount Component Connector Type, Manufacturer, Part Number, Drawing Package Outline Preferred (EIA/JEDEC Standard) sample pack extremely flexible process which lends itself to Which pins are signal lines to be protected? Which pins are ground lines? customization. Our expertise in metal film deposition and dicing techniques—employed over the last decade for manufacturing dis- Environmental Spec crete and array overcurrent protection devices—is now being applied to SurgX. What Number of Prototypes and Timing does this mean to you? It means Bussmann can supply custom solutions to your specific Estimated Annual Usage and Timing design problems. How do you get started? It’s simple: just provide us with the following Target Price information and we will give you an immediate firm quotation covering tooling and prototype charges, as well as production piece SurgX Supply Contact Information: Name, Title, Company, Address, City, State, Zip Code, Phone, Fax, e-mail • prices. Our tooling charges and turn-around time will pleasantly surprise you. Send To: Bussmann Division, Cooper Industries Attn: Application Engineering P.O. Box 14460 St. Louis, MO 63178 Fax 314-527-1607 11 Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Get the latest, most up-to-date specification data on products listed in this bulletin by calling Bussmann Information FAX. BIF is a simple to use automated fax response system. No need to wait for normal business hours, BIF is available around the clock for your convenience. All you need is a touch-tone telephone and a fax machine to get the most recent specification data when you want it. The SurgX BIF document is No. 3602. To get the most recent version, simply call 314-527-1450 and follow the prompts. In a matter of minutes the data will be faxed to you. It’s that simple! Bussmann Visit us on the web at http://www.bussmann.com © 1997 Cooper Industries, Bussmann Division P.O. Box 14460 St. Louis, MO 63178-4460 314-527-3877 Fax 1-800-544-2570 This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Bulletin: SurgX.497