Cut Sheet

advertisement
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0166-2 Name: 7F-166
7F
100:
DATE: JAN 19 2006
Time: 5:06:30 PM Operator: RB
Application:
EL elbows are installed in
conduit run or in box or fitting
hub:
ɀ to change direction in threaded
rigid conduit run by 90°, or when
terminating at a box or fitting
Features:
UNY, UNF and UNL unions have:
ɀ compact design which permits
assembly with a minimum of
clearance to other adjacent
conduit and/or equipment
ɀ strong and durable
construction
UNA unions:
ɀ have a single clamping nut on
angle, making it both a union
and a connector
ɀ permit conduit joints at angles
between 90° and 180°
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups
A,B,C,D
Class II, Div. 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
EL 1⁄2⍯, 3⁄4⍯, 1⍯
UNF/UNY 105, -215, -205, -305
UNL 105, -125, -215, -205
Class I, Division 1 & 2, Groups B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
UNF/UNY406, -506,
-606, -706, -806,
-905, -1005
Class I, Division 1 & 2, Groups C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
EL, UNF, UNL, UNY all sizes
Class I, Division 1 & 2, Group D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
UNA
ɀ UL Standard: 886
ɀ CSA Standard: C22.2 No. 30
Standard Materials:
Standard Finishes:
ɀ Steel – electrogalvanized with
chromate treatment
ɀ Feraloy iron alloy, malleable
iron – electrogalvanized and
aluminum acrylic paint
UNL
Size
1⁄2 to 1⁄2
3⁄4 female to 1⁄2 male
1⁄2 female to 3⁄4 male
3⁄4 to 3⁄4
Cat. #
UNL105
UNL125
UNL215
UNL205
Dimensions
ɀ Copper-free aluminum – add
suffix SA to Cat. No. (not
available on UNA or 5⍯ and 6⍯
UNY/UNF)
1⁄2⍯
- 4⍯
- 4⍯
5⍯ - 6⍯
5⍯ - 6⍯
UNY
UNF
Male
Female
Size
Cat. #
1⁄2
UNY105
1⁄2 female to 3⁄4 male UNY215
3⁄4
UNY205
1
UNY305
UNY405
11⁄4
UNY406
11⁄4
UNY505
11⁄2
UNY506
11⁄2
2
UNY605
2
UNY606
UNY705
21⁄2
UNY706
21⁄2
3
UNY805
3
UNY806
UNY905
31⁄2
4
UNY1005
5
UNY012
6
UNY014
Size
1⁄2
3⁄4 to 1⁄2
3⁄4
1
11⁄4
11⁄4
11⁄2
11⁄2
2
2
21⁄2
21⁄2
3
3
31⁄2
4
5
6
Cat. #
UNF105
UNF215
UNF205
UNF305
UNF405
UNF406
UNF505
UNF506
UNF605
UNF606
UNF705
UNF706
UNF805
UNF806
UNF905
UNF1005
UNF012
UNF014
UNY
Size
1⁄2
3⁄4-1⁄2
3⁄4
1
11⁄4
11⁄2
2
21⁄2
3
31⁄2
4
5
6
Length
23⁄8
27⁄16
27⁄16
23⁄4
33⁄16
39⁄16
33⁄4
45⁄8
5
51⁄2
55⁄8
51⁄4
53⁄8
UNF
Max.
Dia.
11⁄2
113⁄16
113⁄16
17⁄8
23⁄4
31⁄16
313⁄16
45⁄16
51⁄16
511⁄16
63⁄16
83⁄16
95⁄16
Length
113⁄16
13⁄4
13⁄4
2
21⁄4
25⁄8
29⁄16
33⁄16
37⁄16
41⁄8
41⁄8
313⁄16
313⁄16
Max.
Dia.
11⁄2
113⁄16
113⁄16
17⁄8
23⁄4
31⁄16
313⁄16
45⁄16
51⁄16
511⁄16
63⁄16
83⁄16
95⁄16
125
211⁄16
113⁄16
21⁄16
17⁄16
215
27⁄8
113⁄16
21⁄4
15⁄8
205
27⁄8
113⁄16
21⁄4
15⁄8
UNL
product.
STIBOINFO((CRH:66008com:7F:166))
1⁄2⍯
Dim.
a
b
c
d
† See compliances for classification of each
CH0 0 7 F - 2
Explosionproof
Dust-Ignitionproof
90° Angle
Options:
166
Typedriver Name: TS name csm no.: 100
Certifications and
Compliances:
EL elbows have a smooth interior
and are both strong and
compact.
ɀ UNY, UNF unions – 1⁄2⍯ to 1⍯ –
steel
ɀ UNY, UNF unions – 11⁄4⍯ to 6⍯ –
Feraloy® iron alloy
ɀ UNL, UNA unions – Feraloy
iron alloy
ɀ EL elbows – Feraloy iron alloy
or ductile iron
TCP: 15001
Cl. I, Div. 1 & 2, Groups A,B,C,D†
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
Unions and Elbows
UNY and UNF unions are
installed in threaded thickwall
conduit systems:
ɀ UNY – to connect conduit to a
conduit fitting, junction box or
device enclosure
ɀ UNF – to connect conduit to
conduit, or to provide a means
for future modification of the
conduit system
UNA unions are used in conduit
and fitting installations when
entrance angle is between 90°
and 180°.
COLOR: CMYK
US: 1-866-764-5454
CAN: 1-800-265-0502
105
211⁄16
117⁄32
21⁄16
17⁄16
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0167-1 Name: 7F-167
DATE: JAN 19 2006
Time: 5:06:32 PM Operator: RB
COLOR: CMYK
Cl. I, Div. 1 & 2, Groups C,D†
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
Unions and Elbows
90° Male
TCP: 15001
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
7F
90° Female
Male (with removable nipple)
90° Male and female
45° Female
UNA
EL
Male
Size
1⁄2
3⁄4
1
90° Male
Cat. #
UNA16
UNA26
UNA36
Size
1⁄2
3⁄4
1
90° Female
Cat. #
EL195
EL295
EL395
Size
1⁄2
3⁄4
1
11⁄4
11⁄2
2
21⁄2
45° Female
Size
1⁄2
3⁄4
1
11⁄4
11⁄2
2
21⁄2
3
31⁄2
4
Cat. #
EL1
EL2
EL3
EL4
EL5
EL6
EL7
EL8
EL9
EL10
Cat. #
EL19*
EL29*
EL39*
EL49*
EL59*
EL69*
EL79
90° Male and Female
Size
1⁄2
3⁄4
1
11⁄4
Cat. #
EL196*
EL296*
EL396*
EL496
* Available in copper free aluminum – add
suffix SA to catalog number.
Dimensions
EL
UNA
EL
Male
Size
1⁄2
3⁄4
1
Length
45⁄16
413⁄16
511⁄16
Width
25⁄8
27⁄8
31⁄2
45°
90°
Female Male
Size
1⁄2
3⁄4
1
11⁄4
11⁄2
2
21⁄2
3
31⁄2
4
90° Male
90° Female
45° Female
90° Male and female
a
13⁄16
13⁄8
121⁄32
13⁄4
115⁄16
21⁄4
23⁄4
31⁄6
37⁄16
35⁄8
a
17⁄16
15⁄8
17⁄8
90°
90°
Male &
Female Female
a
117⁄32
13⁄4
2
21⁄4
4
5
67⁄16
a
117⁄32
15⁄8
17⁄8
21⁄8
† See compliances for classification of each product.
US: 1-866-764-5454
STIBOINFO((CRH:66008com:7F:167))
CH0 0 7 F - 3
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
167
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0168-1 Name: 7F-168
7F
100:
DATE: JAN 19 2006
Time: 5:06:33 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Cl. I, Div. 1 & 2, Groups C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
UNF/UNY Expansion Unions
Explosionproof
Dust-Ignitionproof
Application:
UNF/UNY expansion unions are designed to
be used in all threaded rigid metal† conduit
systems indoors and outdoors, in hazardous
locations to:
ɀ connect conduit to conduit
ɀ connect conduit to a junction box or device
enclosure
ɀ compensate for conduit cut too short
ɀ allow for expansion and contraction of
conduit
ɀ connect stub-ups to threaded conduit
ɀ replace sections of conduit runs
Features:
ɀ Compact design
ɀ Internal beryllium copper grounding spring
to insure positive grounding continuity.
ɀ Knurled surface on body and sleeve allows
secure gripping with wrench.
ɀ Steel construction for maximum strength.
ɀ Available in two styles – short length where
space is limited, long length when extra
expansion is required.
UNYL
UNFL
UNYL with sleeve extended
UNFL with sleeve extended
UNY
UNF
Male – Short
Conduit Size
1⁄2
3⁄4
1
Standard Materials:
UNYL
ɀ Body and sleeve – steel
ɀ Grounding spring – beryllium copper
Male – Long
Standard Finishes:
ɀ Steel – electrogalvanized with chromate
finish
ɀ Beryllium copper – natural
Certifications and
Compliances:
Conduit Size
1⁄2
3⁄4
1
Female – Short
Cat. #
UNY17
UNY27
UNY37
Conduit Size
1⁄2
3⁄4
1
Cat. #
UNF17
UNF27
UNF37
UNFL
Female – Long
Cat. #
UNYL17
UNYL27
UNYL37
Conduit Size
1⁄2
3⁄4
1
Cat. #
UNFL17
UNFL27
UNFL37
Dimensions
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
ɀ UL Standard: 886
ɀ CSA Standard: C22.2 No. 30
Size
1⁄2
3⁄4
1
1⁄2
3⁄4
1
Dimension
a*
b
UNY
35⁄16
13⁄16
33⁄8
17⁄16
313⁄16
111⁄16
UNYL
45⁄16
13⁄16
41⁄2
17⁄16
53⁄16
111⁄16
c**
d
Size
1⁄2
1⁄2
3⁄4
5⁄8
21⁄16
21⁄8
21⁄4
1
11⁄16
15⁄16
29⁄16
211⁄16
215⁄16
1⁄2
3⁄4
1⁄2
1
1
Dimension
a*
b
UNF
33⁄8
13⁄16
37⁄16
17⁄16
313⁄16
111⁄16
UNFL
43⁄8
13⁄16
49⁄16
17⁄16
51⁄8
111⁄16
c**
d
1⁄2
5⁄8
27⁄8
215⁄16
33⁄16
1
11⁄16
15⁄16
33⁄8
31⁄2
313⁄16
1⁄2
† Suitable with intermediate Metal Conduit
in non-hazardous locations
* Overall length at maximum expansion
** Maximum expansion
168
STIBOINFO((CRH:66008com:7F:168))
CH0 0 7 F - 4
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100