WSAT-XEE WSAN-XEE Water chiller WSAT-XEE: cooling only WSAN-XEE: reversible heat pump Air cooled Outdoor installation Capacity from 83,1 to 218 kW 352÷802 ELFOEnergy Large² HYDRONIC ELFOEnergy Large2 water chillers and heat pumps provide the highest seasonal efficiency. They’re designed to be installed outdoor and feature uneven scroll compressors mounted in the same circuit, electronic expansion valves and high efficiency plate type evaporators. ELFOEnergy Large2 shows an unmatched seasonal efficiency ESEER and is available in two versions: EXCELLENCE and PREMIUM. The standard version EXCELLENCE offers the highest efficiency both at full and at part load. Also the PREMIUM version offers high efficiency at part load but favour also the compact dimensions being therefore extremely competitive. Thanks to its features, ELFOEnergy Large2 offers: self-adaptability in different load conditions, thanks to the availability of several capacity steps and the adjustment logic developed for maximum efficiency and minimum wear very high overall reliability, thanks to the consolidated construction choices and the use of industrially-made products lower sound emissions, achieved thanks to the optimal sizing of the exchange surfaces and the use of high efficiency fans with “winglets” quick and easy installation thanks to the quick connections with the main circuit, electrical wiring enablement and complete functional testing before delivery. The units can also be supplied with pump assemblies, partial heat recovery and inertial storage tank already installed on board, bringing together all the system’s main components in a single solution. Unit listed on www.eurovent-certification.com functions and features AIR Cooling only (WSAT-XEE) Heat pump (WSAN-XEE) Air cooled R-410A Outdoor installation R-410A Hermetic Scroll Ice protection system FC HYDRO PACK ECO BREEZE Free cooling HydroPack ECOBreeze EEV electronic expansion valve dimensions and clearances C A2 B1 B A B2 A1 Size – WSAT-XEE SC-PRM A - Lenght SC-EXC A - Lenght SC-PRM Operating weight SC-EXC Operating weight B - Width C - Height A1 A2 B1 B2 mm mm kg kg mm mm mm mm mm mm 352 2710 3075 778 896 1097 1805 1000 700 1350 1350 402 2710 3075 802 933 1097 1805 1000 700 1350 1350 432 2710 3075 892 1024 1097 1805 1000 700 1350 1350 452 2710 4025 924 1207 1097 1805 1000 700 1350 1350 502 2710 4025 963 1234 1097 1805 1000 700 1350 1350 552 2710 4025 984 1256 1097 1805 1000 700 1350 1350 602 3075 4025 1087 1302 1097 1805 1000 700 1350 1350 702 4025 5025 1295 1497 1097 1805 1000 700 1350 1350 802 4025 5025 1324 1544 1097 1805 1000 700 1350 1350 Size – WSAN-XEE A - Lenght B - Width C - Height A1 A2 B1 B2 SC Operating weight mm mm mm mm mm mm mm kg 352 3075 1097 1805 1000 700 1350 1350 915 402 3075 1097 1805 1000 700 1350 1350 975 432 3075 1097 1805 1000 700 1350 1350 1059 452 3075 1097 1805 1000 700 1350 1350 1101 502 3075 1097 1805 1000 700 1350 1350 1126 552 4025 1097 1805 1000 700 1350 1350 1326 602 4025 1097 1805 1000 700 1350 1350 1341 702 5025 1097 1805 1000 700 1350 1350 1549 802 5025 1097 1805 1000 700 1350 1350 1564 CAUTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas. The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations, refer to the relative Data Sheet. SC-PRM Compressors soundproofing (SC)-Premium SC-EXC Compressors soundproofing (SC)-Excellence SC Compressors soundproofing (SC) 78 versions and configurations PRM D R B SC EN Excellence (WSAT-XEE only) Premium (WSAT-XEE only) Partial energy recovery Total energy recovery Water low temperature Acoustic configuration with compressor soundproofing CREFB CREFP - FCD Extremely low noise acoustic configuration Device for reduction of fan consumption ECOBREEZE Device for fan consumption reduction of the external section with variable speed (phase-cutting) FREE-COOLING: not required (WSAT-XEE only) direct FREE-COOLING (WSAT-XEE only) accessories CCCA Copper / aluminium condenser coil with acrylic lining Standard pump 1PU1SB Standard pump with emergency pump 2PM Hydropack with 2 pumps A300 300 litre storage tank (sizes 352÷602) A500 500 litre storage tank (sizes 702÷802) A300RPS Storage tank of 300 litres with primary circuit onboard (sizes 352÷602) A500RPS Storage tank of 500 litres with primary circuit onboard (sizes 702÷802) ■• IFWX Water steel mesh strainer MHP High and low pressure gauges ■• AMMX Spring antivibration mounts PGCCH Anti-hail protection grilles PGFC Finned coil protection grill. PM Phase monitor SFSTR Disposal for inrush current reduction CMSC10 Serial communication module to LonWorks supervisor CMSC8 Serial communication module to BACnet supervisor CMSC9 Serial communication module to MODBUS supervisor CLSCLR Free contacts compressor state and local / remote management CFSC Free contacts for compressor state SPC1 Set point compensation with 4-20 mA signal SCP3 Set point compensation according to the outside enthalpy SCP4 Compensation of set point with signal 0-10 V 1PUS Key to symbols: ■• PFCP Power factor correction capacitors (cosfi > 0.9) KRIX Kit to remote the control interface by microprocessor WSAT-XEE only: CCCA1 Copper / aluminium condenser coil with Energy Guard DCC Aluminum (sizes 352÷802) ABU Flush hydraulic connections (sizes 352÷602, 702÷602, 702÷602, 702÷602, 702÷602, 702÷602, 702÷802) RE-20 Electrical panel antifreeze protection for min.outdoor temperature up to -20°C RE-25 Electrical panel antifreeze protection for min.outdoor temperature up to -25°C RE-30 Electrical panel antifreeze protection for min.outdoor temperature up to -30°C RE-35 Electrical panel antifreeze protection for min.outdoor temperature up to -35°C RE-39 Electrical panel antifreeze protection for min.outdoor temperature up to -39°C SPC2 Set point compensation with outside temperature probe DV Compressor discharge shut-off valve SDV Compressor discharge and suction shut-off valve FANQE Electrical panel ventilation WSAN-XEE only: OHE Limit extension kit in heating up to -10°C (W.B.) CCCA1 Copper / aluminium condenser coil with Energy Guard DCC Aluminum ABU Flush hydraulic connections (sizes 352÷602, 702÷602, 702÷802) ■• Accessories supplied separately. technical data Size – WSAT-XEE SC-PRM Cooling capacity SC-PRM Compressor power input SC-PRM Total power input SC-PRM EER (EN 14511:2011) SC-PRM ESEER SC-PRM Water flow rate (Utility Side) SC-EXC Cooling capacity SC-EXC Compressor power input SC-EXC Total power input SC-EXC EER (EN 14511:2011) SC-EXC ESEER SC-EXC Water flow rate (Utility Side) SC-PRM Sound pressure level SC-EXC Sound pressure level Refrigerant circuits No. of Compressors Type of compressors Standard power supply (1) (2) (1) (2) (3) (3) kW kW kW l/s kW kW kW l/s dB(A) dB(A) Nr Nr V 352 91 28,6 33,1 2,75 3,91 4,3 97 27,2 31,6 3,07 4,22 4,6 67 67 1 2 scroll 400/3/50 402 101 33,6 38,1 2,66 3,95 4,8 109,6 31,4 35,7 3,07 4,3 5,2 67 67 1 2 scroll 400/3/50 Note (1) Data calculated in complance with Standard EN 14511:2011 Data referred to the following conditions : Internal exchanger water = 12/7°C External exchanger air intake 35°C (2) Data referred to the following conditions : Internal exchanger water = 12/7°C External exchanger air intake 35°C (3) Measures according to UNI EN ISO 9614-2 regulations, with respect to the EUROVENT 8/1 certification. The sound levels refer to the unit at full load, in the rated test conditions. 432 112 37,8 42,3 2,66 3,9 5,4 120,5 35,1 39,5 3,05 4,22 5,8 67 68 1 2 scroll 400/3/50 452 121 40 44,5 2,73 4,03 5,8 130,5 36 42,2 3,09 4,21 6,2 67 68 1 2 scroll 400/3/50 502 130 43,6 48,1 2,71 4,02 6,2 142,4 40,1 46,4 3,07 4,24 6,8 68 68 1 2 scroll 400/3/50 552 142 48,7 53,3 2,67 3,99 6,8 154,3 43,8 50,3 3,07 4,1 7,4 68 69 1 2 scroll 400/3/50 602 161 56,2 60,6 2,66 3,9 7,7 173,3 50,5 56,8 3,05 4,26 8,3 68 69 1 2 scroll 400/3/50 702 182 60,7 67,2 2,71 3,99 8,7 196,2 55,7 63,9 3,07 4,16 9,4 69 70 1 2 scroll 400/3/50 802 203 69,8 76,4 2,66 3,79 9,7 217,1 62,8 71,2 3,05 4,32 10,4 69 70 1 2 scroll 400/3/50 The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. Data referred to the following conditions: Internal exchanger water = 12/7°C Outdoor air temperature 35°C SC-PRM Compressors soundproofing (SC)-Premium SC-EXC Compressors soundproofing (SC)-Excellence 79 HYDRONIC EXC Size – WSAN-XEE Cooling capacity Compressor power input Total power input EER (EN 14511:2011) ESEER Heating capacity Compressor power input Total power input COP (EN 14511:2011) Refrigerant circuits No. of Compressors Type of compressors Water flow rate (Utility Side) Standard power supply Min air inlet temperature (W.B.) Sound pressure level (4) (5) (3) kW kW kW kW kW kW Nr Nr l/s V °C dB(A) 352 82,7 29,1 33,3 2,48 3,43 100,1 29,2 33,6 2,98 1 2 SCROLL 3,9 400/3/50 -6 67 402 94,4 32,8 37,2 2,54 3,56 112,7 33,2 37,7 2,99 1 2 SCROLL 4,5 400/3/50 -6 67 HYDRONIC Note (3) Measures according to UNI EN ISO 9614-2 regulations, with respect to the EUROVENT 8/1 certification. The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. Data referred to the following conditions: Internal exchanger water = 12/7°C Outdoor air temperature 35°C (4) Data calculated in complance with Standard EN 14511:2011 Internal exchanger water = 12/7°C External exchanger air intake 35°C 80 432 104,5 37,3 41,6 2,51 3,54 124,7 36,8 41,4 3,01 1 2 SCROLL 5 400/3/50 -6 67 (5) 452 110,6 39,9 44,2 2,5 3,54 132,6 39,4 43,9 3,02 1 2 SCROLL 5,3 400/3/50 -6 67 502 120,6 44,4 48,6 2,48 3,56 142,6 42,2 46,9 3,04 1 2 SCROLL 5,8 400/3/50 -6 67 552 136,5 46,4 52,5 2,6 3,49 167,7 46,3 52,7 3,18 1 2 SCROLL 6,5 400/3/50 -6 68 602 153,5 55,8 62,1 2,47 3,4 186,8 52,3 58,9 3,17 1 2 SCROLL 7,3 400/3/50 -6 68 702 178,4 60,5 68,6 2,6 3,35 215,8 59,2 67,7 3,19 1 2 SCROLL 8,5 400/3/50 -6 71 802 197,3 69,8 78 2,53 3,31 238 66,2 74,6 3,19 1 2 SCROLL 9,4 400/3/50 -6 71 Data calculated in complance with Standard EN 14511:2011 Internal exchanger water = 40/45°C External exchanger air intake = 6.1 °C W.B. SC-PRM Compressors soundproofing (SC)-Premium SC-EXC Compressors soundproofing (SC)-Excellence