Eurovent Class A certification High seasonal efficiency Groundwater or geothermal version Energy recovery Modularity Unit built-in display ELFOENERGY GROUND MEDIUM WSHN-XEE 82-802 High-efficiency geothermal heat pump, ideal for multi-family and business premises. * Due to its high efficiency, "ELFOENERGY GROUND MEDIUM" may be eligible for heat pump subsidies in Your Country. Please contact Your tax office or utility. SP11N03GB-02 ELFOEnergy Ground Medium WSHN-XEE 82-802 Ground and water source heat pump for indoor installation HIGH SEASONAL EFFICIENCY The combination of compressors of different sizes allows to obtain several capacity steps in order to precisely provide the energy actually required by the system, reduce electrical consumption and therefore achieve high seasonal efficiency. The unit meets Eurovent's Class A requirements in heating and cooling mode for use with radiant systems. GROUNDWATER OR GEOTHERMAL VERSION The availability of specific exchangers with groundwater or closed-loop geothermal sources allows maximising energy efficiency. ENERGY RECOVERY The optional total or partial heat recovery provides free heating to satisfy the heat load demand or the production of domestic hot water. FULLY INDUSTRIALIZED SOLUTION All the main components of the system are supplied on the unit, ensuring maximum reliability and ease of installation. MODULARITY AND CASCADE MANAGEMENT OF SEVERAL UNITS The compact design with vertical hydraulic connections allows to place several units in confined spaces and create a high capacity system. The control allows to coordinate up to 6 units by managing their operation automatically with maximum efficiency. Technical data - Groundwater version Sizes Applications with Radiant Systems Heating capacity (1) COP (EUROVENT (2) COP (EN 14511:2008) (3) Cooling capacity (4) EER (EUROVENT) (5) EER (EN 14511:2008) (6) Applications with terminal units Heating capacity (7) COP (EUROVENT) (2) Cooling capacity (8) EER (EUROVENT) (5) Applications with Radiators Heating capacity (9) COP EUROVENT (2) Sound pressure level (1m) Power supply 82 102 122 162 182 222 262 302 352 402 432 452 502 552 602 702 802 kW kW - 34,8 5,86 5,67 40,5 6,47 5,93 42,0 6,00 5,74 47,3 6,26 5,70 47,8 5,79 5,52 58,6 6,25 5,53 55,7 5,74 5,46 64,9 5,77 5,10 66,1 5,74 5,44 77,4 6,04 5,32 79,0 5,79 5,58 92,7 5,95 5,38 93,4 5,78 5,58 109 6,15 5,62 106 5,79 5,57 124 6,05 5,48 121 5,73 5,50 141 5,91 5,30 139 5,78 5,53 162 5,99 5,35 153 5,75 5,51 180 5,84 5,23 164 5,77 5,53 192 5,98 5,34 178 5,73 5,48 209 5,83 5,17 196 5,77 5,50 230 5,89 5,20 221 5,73 5,42 257 5,84 5,11 250 5,63 5,32 291 5,91 5,13 280 5,55 5,20 321 5,96 5,10 kW kW 33,0 4,30 29,0 4,70 39,7 4,37 33,8 4,71 46,4 4,34 42,0 4,77 53,4 4,35 46,9 4,44 63,2 4,36 55,4 4,55 75,1 4,38 66,8 4,50 88,6 4,38 78,1 4,58 101 4,41 89,4 4,53 114 4,38 101 4,48 131 4,42 116 4,55 145 4,41 129 4,48 155 4,40 137 4,53 168 4,38 149 4,47 185 4,41 164 4,52 209 4,36 184 4,47 236 4,35 207 4,40 266 4,40 229 4,35 kW dB(A) V/Ph/Hz 31,7 3,24 64 37,9 3,29 64 44,8 3,35 64 50,0 3,18 68 58,6 3,14 69 70,4 3,32 68 82,6 3,31 69 94,1 107 123 3,38 3,33 3,37 68 76 76 400/3/50+N 136 3,35 79 146 3,35 76 159 3,32 79 174 3,35 79 197 3,30 79 224 3,29 80 251 3,28 81 - Data referring to the following conditions: (1) Utility side water inlet/outlet 30/35°C, source side water inlet 0/-3°C. (2) COP EUROVENT: performance coefficient in heating mode. Ratio between heating capacity and power absorbed in compliance with EUROVENT. (3) COP (EN 14511:2008) performance coefficient in heating mode. Ratio between thermal capacity output and power absorbed in compliance with EN 14511:2008. (4) Utility side water inlet/outlet 23/18°C, source side water inlet/outlet 30/35°C. (5) EER EUROVENT: performance coefficient in cooling mode. Ratio between cooling capacity output and power absorbed in compliance with EUROVENT. (6) EER (EN 14511:2008) performance coefficient in cooling mode. Ratio between cooling capacity output and power absorbed in compliance with EN 14511:2008. (7) Utility side water inlet/outlet 40/45°C, source side water inlet 0/-3°C. (8) Utility side water inlet/outlet 12/7°C, source side water inlet/outlet 30/35°C. (9) Utility side water inlet/outlet 50/55°C, source side water inlet 0/-3°C. Technical data - Geothermal version Sizes Applications with Radiant Systems Heating capacity (1) COP (EUROVENT) (2) COP (EN 14511:2008) (3) Cooling capacity (4) EER (EUROVENT) (5) EER (EN 14511:2008) (6) Applications with terminal units Heating capacity (7) COP (EUROVENT) (2) Cooling capacity (8) EER (EUROVENT) (5) Applications with Radiators Heating capacity (9) COP EUROVENT (2) Sound pressure level (1m) Power supply 82 102 122 162 182 222 262 302 352 402 432 452 502 552 602 702 802 kW kW - 26,2 4,45 4,32 39,9 6,15 5,62 30,5 4,47 4,31 47,3 6,27 5,61 36,2 4,56 4,34 56,6 6,03 5,27 43,1 4,53 4,32 64,0 5,55 4,92 51,5 4,55 4,33 76,7 5,87 5,13 60,6 4,53 4,31 91,6 5,72 5,10 73,0 4,60 4,41 108 5,95 5,39 81,5 4,55 4,34 123 5,82 5,21 93,3 4,55 4,32 140 5,70 5,05 108 4,59 4,35 160 5,79 5,12 119 4,56 4,32 178 5,64 4,98 126 4,57 4,33 194 5,94 5,21 138 4,58 4,32 207 5,63 4,93 152 4,58 4,32 227 5,70 4,97 171 4,58 4,30 254 5,67 4,87 198 4,62 4,32 285 5,63 4,81 227 4,63 4,30 313 5,59 4,72 kW kW 26,0 3,39 28,5 4,45 29,5 3,30 33,8 4,71 34,6 3,33 40,5 4,67 41,6 3,38 46,4 4,30 49,5 3,42 55,0 4,44 58,4 3,48 66,2 4,37 70,0 3,53 77,6 4,47 78,5 3,54 88,5 4,41 89,7 3,53 100 4,36 104 3,56 115 4,44 115 3,54 127 4,36 121 3,54 139 4,54 133 3,54 148 4,34 147 3,55 163 4,40 165 3,55 182 4,36 191 3,60 205 4,29 217 3,64 227 4,25 kW dB(A) V/Ph/Hz 25,3 2,56 64 28,7 2,42 64 32,8 2,49 64 40,1 2,53 68 47,5 2,55 69 55,8 2,63 68 66,8 2,67 69 74,8 2,71 68 86,2 100,0 2,70 2,73 76 76 400/3/50+N 111 2,72 79 117 2,71 76 129 2,72 79 142 2,76 79 160 2,75 79 184 2,79 80 209 2,82 81 - (5) EER EUROVENT: performance coefficient in cooling mode. Ratio between cooling capacity output and power absorbed in compliance with EUROVENT. (6) EER (EN 14511:2008) performance coefficient in cooling mode. Ratio between cooling capacity output and power absorbed in compliance with EN 14511:2008. (7) Utility side water inlet/outlet 40/45°C, source side water inlet 0/-3°C. The water flow rate in the source exchanger is identical to the water flow rate in cooling mode (in compliance with Eurovent). (8) Utility side water inlet/outlet 12/7°C, source side water inlet/outlet 30/35°C. (9) Utility side water inlet/outlet 50/55°C, source side water inlet 0/-3°C. Data refer to operation with a mix of water and propylene glycol at 30% on the source side. (1) Utility side water inlet/outlet 30/35°C, source side water inlet 0/-3°C. The water flow rate in the source exchanger is identical to the water flow rate in cooling mode (in compliance with Eurovent). (2) COP EUROVENT: performance coefficient in heating mode. Ratio between heating capacity and power absorbed in compliance with EUROVENT. (3) COP (EN 14511:2008) performance coefficient in heating mode. Ratio between thermal capacity output and power absorbed in compliance with EN 14511:2008. (4) Utility side water inlet/outlet 23/18°C, source side water inlet/outlet 30/35°C. SIZES 82 102 122 162 182 222 262 302 352 402 432 452 502 552 602 702 802 Length mm 1200 1200 1200 1200 1200 1200 1200 1200 1966 1966 1966 1966 1966 1966 1966 1966 1966 Height (1) mm 1400 1400 1400 1400 1400 1400 1400 1400 1570 1570 1570 1570 1570 1570 1570 1570 1570 Height (2) mm 1980 1980 1980 1980 1980 1980 1980 1980 2125 2125 2125 2125 2125 2125 2125 2125 2125 Depth mm 656 656 656 656 656 656 656 656 948 948 948 948 948 Weight (1) kG 407 425 453 504 517 531 545 611 1011 1042 1169 1179 1193 1228 1258 1306 1333 (1) Data referring to units without hydronic unit (2) Data referring to units with hydronic unit 948 948 948 948 CLIVET S.p.A. Via Camp Lonc 25 32032 Z.I. Villapaiera Feltre BL Tel. + 39 0439 3131 Fax. + 39 0439 313382 info@clivet.it Please refer to the technical leaflet for clearance distances. The data contained in this document is not binding and may be modified by the Manufacturer without prior notice. The reproduction, even partial, is prohibited.