Edco PC2-TEL Two Line Telephone Protection (Modular) The Edco PC2-TEL is a solid state, two-line telephone interface protector module. This unit is specifically designed to protect both phone lines required by commercial fire/security panels. General Technical Specifications Operating Voltage 250 VDC Clamping Voltage 270 VDC Operating Current Peak Surge Current Frequency Range Insertion Loss SPD Technology Connection Type Operating Temperature Dimensions (in / mm) 0.15 A 160 A (10 x 1000 T & R to Ground) 0 to 20 MHz < 0.1 dB at 20 MHz Silicon Breakover Device w/Series PTC Terminal block w/ compression lugs Terminals accept up to 10 AWG -40°C to +85°C 2.0˝ H x 1.0˝ W x 2.5˝ L [50.8 x 25.4 x 63.5 mm] (PC2TEL + PCB1B-WKEY Base) Weight (oz / kg) 1 oz [0.03 kg] Certifications UL 497A, CUL Warranty EDCO PCB1B-WKEY BASE SOLD SEPARATELY 5 years Features ■■ Tip to ring protection ■■ Tip and ring to ground protection ■■ Over-current protection ■■ Resettable solid state fuses — PTCs ■■ UL Listed 497A ■■ Requires PCB1B-WKEY base ■■ PC642PTU (Pass Thru Unit) available for troubleshooting Caution Do not place this product in service on any signal line capable of continuously supplying more than 150 mA. Attention Ne pas placer ce produit dans le service sur une ligne de signal capable de fournir en permanence plus de 150 mA. ■■ 5 year warranty Ordering Information 2 Line Telephone PC2-TEL Installation Instructions VDANGER! Only qualified personnel should install or service this system. Electrical safety precautions must be followed when installing or servicing this equipment. To prevent risk of electrical shock, turn off and lock out all power sources to the unit before making electrical connections or servicing. Terminal Assignments PCB1B-WKEY Odd Terminals Unprotected Pair 2 { Field Side Unprotected Pair 1 { Even Terminals 10 9 8 7 6 5 4 3 2 1 } Protected Pair 2 Electronics Side } Protected Pair 1 Keying Pin 2.4" [60.96] 2.125" [53.98] Seulement le personnel qualifié doit installer ou maintenir ce systéme. Des précautions de sécurité en électricité doivent être suivis lors de l’installation ou de la maintenance de cet equipement. Pour eviter tout risque de choc électrique, débranchez et verouiller toutes les sources d’alimentation de cet equipement avant de. 1.0” [25.40] • Connect ground terminals, positions 1 or 10 (internally tied together) to Building Approved Ground. (See Edco Tech Bulletin #2015) NOT intended for shield termination. Install ground in accordance with all applicable codes. • Edco PCB1B-WKEY accommodates 26 to 10 AWG wire. • Disconnect telephone line at the network interface before installing this secondary device. • This product is intended for indoor use only. Emerson Network Power Contact information www.EmersonNetworkPower.com/Surge Surge Protection 100 Emerson Parkway Binghamton, NY 13905 T: (607) 721-8840 T: (800) 288-6169 F: (607) 722-8713 E: SurgeTech@Emerson.com IO-50117 12/14 Rev. 4 Printed in USA Emerson Network Power, the Emerson Network Power logo and Edco are trademarks and service marks of Emerson Electric Co. ©2014 Emerson Electric Co. While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power Surge Protection assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.