www.ANNUNCIATOR.ca AR7525 Series Alarm Annunciators AR7525 Series Split Alarm Annunciator Ultimate Flexibility and Reliability AR7525 Series alarm Annunciator, Full Function, Flexible and Reliable provides an ideal solution to all your alarm system requirements. Separate Display and Electronics Split Architecture allows remote installation of electronic modules and window display. The modular construction allows system of almost any size . Exceptional flexibility, reliability and programmability. No Master Module Modular Multipoint Design Common and Auxiliary Relays Field Programmable Alarm sequence to ISA-S18.1 Long Life LEDs A large range of options can be supplied in addition to the standard unit, to fulfill all annunciator requirements. All Sizes Configurable Low Cost for all system sizes AR7525 Series Alarm Annunciators Features Modular Split Construction The modular split construction of AR7525 Series allows almost any size to be constructed. Split Architecture allows remote installation of electronic modules and window display. No Master Module Reliability is the first priority in safety critical applications like alarm annunciation. The AR7525 Series annunciator uses a unique solution to provide unparallel reliability. Unlike microprocessor controlled systems, the AR7525 Series has no master module and Each alarm point has it’s own logic card. Power Supply A nominal 24VDC power supply is required to run the annunciator system. This can be an unregulated supply (19 to 30VDC) and there is no need for transient suppression. Push Buttons System supports all push buttons necessary for different operating sequences. The available push buttons are “Acknowledge”, Reset”, “ Test” and “Mute”. www.ANNUNCIATOR.ca Illumination Back-lit display by almost Unlimited Life time, 120°, high bright LEDs. Each H21 type (medium size window) has two LEDs per alarm point. This number for H11 (large window) is 4 and for H44 (small window) is 1 LED per alarm point. Windows are bright enough to be clearly seen in the highest ambient light. Available in different colors. Inputs Inputs are generally normally open or normally close voltage free contacts or voltage input through an Opto-coupler, configurable by jumper settings for each alarm point. Option of voltage input from field, PLC or personal computer can be supplied with contact voltages of 24, 48, 110, 220 (AC or DC voltages). Outputs System Supports the following outputs: - Display Output - Audio Output - Auxiliary Output - Common Alarm Output - First_Up Output Shallow Depth Auxiliary Relay The display is only 78mm deep. Services No special tools are required to replace , replace cards or changing the operating sequence and configuration. Each alarm point can be supplied with an individual repeat relay. The repeat relays can be set to follow the input or output. NO and NC contacts are available for each repeat relay. www.ANNUNCIATOR.ca AR7525 Series Alarm Annunciators Window/Cell Configuration: Type H11 75mm 40mm 50mm 65mm Type H12 Type H21 40mm 20mm 20mm 65mm Outer Sizes As Above 32.5mm 32.5mm Outer Sizes As Above Display Size Calculation _ 0.5 Length(mm)=Cx75+37+ _ 0.5 Height(mm)= Rx50+37+ Type H44 20mm Cutout Size Calculation 20mm 32.5mm 32.5mm Outer Sizes As Above Type V21 _ 0.5 Length(mm)= Cx75+33+ _ 0.5 Height(mm)= Rx50+33+ C: Number of Columns R: Number of Rows Integral Pushbutton & Buzzer Module 40mm 32.5mm 32.5mm As an option, an integral “Pushbutton and Buzzer Module” can be fitted in the bottom right window Outer Sizes As Above www.ANNUNCIATOR.ca AR7525 Series Alarm Annunciators Alarm Sequences Each alarm channel can be configured to suit the operating sequence required as listed in the ISA publication Annunciator Sequences and Specification S18.1, 1979. Systems can be configured with different features on different alarm ways. Available Sequences on standard AR7525 (Field Selectable) are “Manual Reset”(M), “Auto Reset ”(A), “Manual Reset First Out (F2M-1)” and “Auto Reset First Out (F1A). Other sequences need special order. Manual Reset / Sequence code M Process Abnormal or Normal Sequence Acknowledged Visual On Audible Silent to abnormal Process Abnormal or Normal Sequence Alarm Visual Flashing acknowledge Audible Audible reset while normal Process Normal Sequence Normal Visual Off Audible Silent Auto Reset / Sequence code A acknowledge while normal Process Abnormal Sequence Acknowledged Visual On Audible Silent acknowledge while abnormal to abnormal return while normal Process Normal Sequence Normal Visual Off Audible Silent Process Abnormal or Normal Sequence Alarm Visual Flashing Audible Audible www.ANNUNCIATOR.ca AR7525 Series Alarm Annunciators Automatic Reset First Out / Sequence F1A With No Subsequent Alarm State acknowledge while normal (first out reset) subsequent to abnormal Process Abnormal Sequence Acknowledged Visual On Audible Silent first to abnormal return to normal Process Normal Sequence Normal Visual Off Audible Silent acknowledge whileabnormal (first out reset) Process Abnormal or Normal Sequence First Alarm Visual Flashing Audible Audible Manual Reset First Out / Sequence F2M-1 With No Subsequent Alarm Flashing and Silence Pushbutton reset while normal Process Normal Sequence Normal Visual Off Audible Silent first to abnormal subsequent to abnormal acknowledge (first out reset) acknowledge (first out reset) Process Abnormal or Normal Sequence First Alarm Visual Flashing Audible Audible Process Abnormal or Normal Sequence First Silenced Visual Flashing Audible Silent Process Abnormal or Normal Sequence Acknowledged Visual On Audible Silent Process Abnormal or Normal Sequence Subsequent Alarm Visual On Audible Audible mute and acknowledge mute AR7525 Series Alarm Annunciators www.ANNUNCIATOR.ca System Specification Modular Multi-point Split Design Remote Logic Controllers Any number of windows High Reliability and Maintenance Free Mounting: Panel Mounting (Flush) Low Cost for all system sizes Construction Material: Aluminum Illumination: Almost Unlimited Life Time, Alarm Text: Engraving or Translucent Film 120° high bright LEDs Input Voltage: 24VDC or AC Installed Display Depth: Only 78mm (3.07”) Power Consumption: 50mA Per Point, 4mA (at 24VDC) in Quiescent mode For Display, Cutout and Window Size, see Configuration Page Options and Order Number Number of Columns (Specify) 1- With Auxiliary Relay 0- No Auxiliary Relay AR7525 03 04 H11 L V1 1 Number of Rows Window Configuration 0 Alarm Sequence 1- Standard Sequences (M, A, F2M-1, F1A) 0- Other Sequences (Specify) 0 Model # Signal Voltage V1: 24/110V V2: 24/48V V3: 24/220V V4: Others Built-in Buzzer & Pushbutton Module 1- Yes 0-No