Rail Signal Bungalow Protection EPD1224ATAAR Secondary power protector 1 EPD Power Surge Devices • Series hybrid TVSS technology • Universal design for 12VDC & 24VDC applications • 30A series filter • High surge rating provides a high level of protection and long operational life • Low let-through voltage • RFI/EMI filtering • Visual status indication • AAR terminals EPD Power Surge Devices • Transient Discriminating Technology helps ensure safe operation during abnormal over voltage events • Parallel hybrid SPD technology • Low let-through voltage • Visual status indication EPD120/240TDFL Primary surge protector Surge Panel 3 Antenna 2 Coaxial Cable Main AC Power Panel Rectifier Rectifier 11 Ground Rod Copper-bonded ground rod with 10 mils plating thickness assures long service life Ground Bar Batteries 10 Other Grounding Products In order to achieve desired low grounding resistance in the specific soil conditions, ERICO offers Ground Enhancement Material (GEM), and Ground Testers (EST Series). Copper Conductor Ground Loop Signalling Cable 8 2 Dinline Surge Filters • Compact design – sm • High efficiency sine w • DIN rail mount • Status indication • High surge rating, 50 • TD technology www.erico.com Includes primary grounding point for the whole bungalow. This system protects every incoming signal line and keeps the “clean” and “dirty” wiring separated. The flat copper strip provides low-impedance interconnections between all arresters. This panel can be custom designed for specific applications. Four post design accomodates test link for ease of inspection access ETSP Track Circuit Protection Devices • Hybrid technology comprising GDT voltage switching and MOV voltage clamping components • Design includes fail-safe, open circuit, end of life mode • Product plainly marked with voltage and part number to help ensure proper application • 50kA maximum surge rating provides protection suitable for exposed trackside equipment • Low let-through voltage, essential for protection of electronics • Epoxy coating helps ensure stability of operation under adverse conditions and in locations of high humidity SBB2700A2B10 TERMINAL BLOCKS 4 ETSP SERIES 5 Radio Communications Protection • Robust design • Simple plug-in installation • CSP models to suit N and BNC cable terminations • CSP bulkhead N-type versions available • High impulse current rating (20kA 8/20μs) • Wide operating frequency spectrum • Low insertion and return loss • Mounting bracket and ground lead included • CE approved CSP SERIES 6 Signal and Communications Equipment Rack RTB 7 Control Signal Equipment Protection • Protection of low voltage circuits and transducers • Replaceable module design • Efficient multiple stage clamping circuit technology helps ensure lowest possible let-through voltage to equipment • Common-mode and differential-mode protection • Surge rating to 20kA – ideal for exposed wiring • Design includes fail-safe, open circuit, end of life mode 9 CADWELD® Connections ERICO offers a wide variety of exothermic connections for any application CADWELD ONE SHOT ® GR NT GT NX Typical Signal Bungalow Power Protection Layout Lightning Threat Direct & Indirect Load Center Vac EPD120TDAARB Vac Vac EPD120TDAARB Primary Parallel SPD & Filter Secondary Series SPD & Filter Vac 2 TDF Series 8 Utility Reclosure Vac Inverter Vdc Modem, Computer Equipment Etc. 5 Track Circuits Vac Vac ETSP Battery Charger Vac Battery Charger Vdc Vdc Batteries Batteries EPD1224ATAAR Vdc 24V Sensitive Electronics Secondary Series TASS & Filter EPD1224ATAAR Vdc 1 12V Sensitive Electronics mall footprint wave filtering Entrance Panel kA WARNING ERICO products shall be installed and used only as indicated in ERICO’s product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. www.erico.com 3 www.erico.com AUSTRALIA CHINA HUNGARY NORWAY SWITZERLAND Phone 1-800-263-508 Fax 1-800-423-091 Phone +86-21-3430-4878 Fax +86-21-5831-8177 Phone 06-800-16538 Fax +39-0244-386-107 Phone 800-100-73 Fax 800-100-66 Phone 0800-55-86-97 Fax 0800-55-96-15 BELGIUM DENMARK INDONESIA POLAND THAILAND Phone 0800-757-48 Fax 0800-757-60 Phone 808-89-372 Fax 808-89-373 Phone +62-21-575-0941 Fax +62-21-575-0942 Phone +48-71-349-04-60 Fax +48-71-349-04-61 Phone +66-2-267-5776 Fax +66-2-636-6988 BRAZIL FRANCE ITALY SINGAPORE Phone +55-11-3623-4333 Fax +55-11-3621-4066 Phone 0-800-901-793 Fax 0-800-902-024 Phone 800-870-938 Fax 800-873-935 Phone +65-6-268-3433 Fax +65-6-268-1389 UNITED ARAB EMIRATES CANADA GERMANY MEXICO SPAIN UNITED KINGDOM Phone +1-800-677-9089 Fax +1-800-677-8131 Phone 0-800-189-0272 Fax 0-800-189-0274 Phone +52-55-5260-5991 Fax +52-55-5260-3310 Phone 900-993-154 Fax 900-807-333 Phone 0808-2344-670 Fax 0808-2344-676 CHILE HONG KONG NETHERLANDS SWEDEN UNITED STATES Phone +56-2-370-2908 Fax +56-2-369-5657 Phone +852-2764-8808 Fax +852-2764-4486 Phone 0800-0200-135 Fax 0800-0200-136 Phone 020-790-908 Fax 020-798-964 Phone 1-800-753-9221 Fax +1-440-248-0723 Copyright ©2007, 2011 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. Phone +971-4-881-7250 Fax +971-4-881-7270 R726B-WWEN R817LT11WWEN 1M0711