Ground Fault Circuit Interrupters (GFCIs)

advertisement
Ground Fault Circuit
Interrupters (GFCIs)
Page
Page
Build-To-Spec
G-1
ArrowLinkTM Modular Connectors
G-2
Hospital Specification Grade GFCIs
G-5
2-Pole, 3-Wire Grounding
15A, 125V/AC. . . . . . . . . . . . . NEMA 5-15 . . . . . . . . . . . . . G-5
20A, 125V/AC. . . . . . . . . . . . . NEMA 5-20 . . . . . . . . . . . . . G-5
Specification Grade GFCIs
G-5
2-Pole, 3-Wire Grounding
15A, 125V/AC. . . . . . . . . . . . . NEMA 5-15 . . . . . . . . . . G5–G6
20A, 125V/AC. . . . . . . . . . . . . NEMA 5-20 . . . . . . . . . . G5–G6
Combination Switch/GFCI, 2-Pole 3-Wire Grounding
15A, 125V/AC. . . . . . . . . . . . . NEMA 5-15 . . . . . . . . . . . . . G-6
Blank Face (Dead-Front), 2-Pole, 3-Wire Grounding
20A, 125V/AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-6
G
SECTION
Table of Contents
Industrial Grade Portable GFCIs
G-7
15A Portable GFCIs
Plug Series, Single or Tri-Tap Connector . . . . . . . . . . . . . . G-8
Plug Series, Field Wireable . . . . . . . . . . . . . . . . . . . . . . . . . G-8
Inline Series, Single or Tri-Tap Connector . . . . . . . . . . . . . . G-8
Inline Series, Field Wireable . . . . . . . . . . . . . . . . . . . . . . . . G-8
20A Portable GFCIs
Inline Series, Field Wireable . . . . . . . . . . . . . . . . . . . . . . . . G-9
Inline Series, Molded Plug & Connector . . . . . . . . . . . . . . . G-9
30A Portable GFCIs
Inline Series, Field Wireable, Single Phase . . . . . . . . . . . . G-10
Inline Series, Molded Plug & Connector . . . . . . . . . . . . . . G-10
Watertight Portable GFCIs
15A,
20A,
20A,
20A,
30A,
30A,
Straight Blade . . . . . . . . NEMA 5-15 . . . . . . . . . . . . G-11
Straight Blade . . . . . . . . NEMA 5-20 . . . . . . . . . . . . G-11
Locking . . . . . . . . . . . . . NEMA L5-20 . . . . . . . . . . . G-11
Locking . . . . . . . . . . . . . NEMA L6-20 . . . . . . . . . . . G-11
Locking . . . . . . . . . . . . . NEMA L5-30 . . . . . . . . . . . G-11
Locking . . . . . . . . . . . . . NEMA L6-30 . . . . . . . . . . . G-11
Specification Information
www.arrowhart.com
G-12
Section G
SECTION
G
GFCI Families
Protecting people from
electrical shock hazards
ArrowHart’s complete offering of Ground Fault Circuit
Interrupters (GFCIs) is built to meet every need in commercial,
industrial and institutional settings, whether permanent or
temporary – and is fully compliant with the latest UL943
standards for GFCIs.
Hospital Specification Grade GFCIs
Specification Grade GFCIs
Designed for safety and reliability, Arrow
Hart GFCI receptacles meet the strict
standards of UL 943 (GFCI) and UL 498
(Hospital Grade Receptacle Standards).
Plus, our broad line provides solutions
including Tamper Resistant, ArrowLink
Modular and NAFTA compliant versions.
Arrow Hart GFCI receptacles meet the
stringent UL 943 (GFCI) standards, plus
our broad line provides solutions for
commercial, industrial and institutional
applications.
Industrial Spec Grade Portable GFCIs
Portable GFCIs are specifically designed to protect
personnel and equipment from ground fault hazards
in indoor or outdoor jobsite applications.
Section G
www.arrowhart.com
G
SECTION
GFCI Options
Tamper Resistant, Weather Resistant and Tamper & Weather Resistant GFCIs
How the Tamper Resistant system works:
Shutters restrict access in closed position.
Tamper Resistant
Insertion of object in any one side will
not open shutters.
“TR” mold mark
provides quick visual
confirmation of tamper
resistance when
installed.
Weather Resistant
“WR” identifier
quickly indicates
during inspections
that a weather
resistant device has
been installed.
Insertion of two-bladed plug or grounding
plug will open shutters.
Tamper & Weather Resistant
Both the “TR” mold
mark and “WR”
identifier are clearly
visible in the finished
installation, indicating
double-layer
protection for
maximum safety.
2008 National Electric Code
2008 NEC – 517.18 (C) Pediatric Locations
Receptacles located within the rooms,
bathrooms, playrooms, activity rooms and
patient care areas of pediatric wards shall be
listed under tamper resistant or employ a
listed tamper resistant cover.
B) TR for non-hospital sections –
2008 NEC – 406.11 Tamper Resistant
Receptacles in Dwelling units
In all areas specified in 210.52 all 125-volt,
15- and 20-amp receptacles shall be
listed tamper resistant receptacles.
C) WR for all sections – 2008 NEC – 406.8
Receptacles in Wet or Damp Locations
All 15- and 20-amp, 125- and 250-volt
non-locking receptacles installed in wet or
damp locations shall be weather resistant
receptacles.
Build-To-Spec
For Receptacles, Switches, GFCIs & TVSS devices
Modified at the factory to improve efficiency and speed production at the job site. Arrow Hart’s Build-To-Spec
program provides customized device solutions to simplify your project and maximize your bottom line.
Sample Number:
VGF20W
Base Catalog Number
(including device color)
PSOL X Z G P
Remove mounting screws
Remove ears
Add 6" leads
PSOL = #12 AWG solid
PSTR = #12 AWG stranded
Remove ground clip
Add push-in connector**
Arrow Hart 20A 125V NEMA 5-20 white GFCI
receptacle, with wire leads and push-in
connectors, without mounting screws, ears, or
grounding clip.
**For use with leaded receptacles only. Add “PSOL” to back of receptacle catalog number for 6” of #12 AWG solid or “PSTR” for 6” of #12 AWG stranded.
(Example: VGF20W PSOL + Build to Spec Options).
All receptacles are bulk packed 50 pieces per carton. Minimum order quantity is 100 pieces. Orders under 500 pieces ship within 5 days with larger quantities
typically within 10 days.
www.arrowhart.com
G-1
SECTION
G
ArrowLinkTM Modular Connectors
ArrowLink
Arrow Hart's factory terminated ArrowLink system
revolutionizes device installation, unleashing
groundbreaking labor savings in installation and
maintenance by eliminating traditional pigtailing,
terminal connections and taping. Use ArrowLink
on your next job to reduce labor costs, eliminate
installation errors, save money and win!
ArrowLink SPD
Benefits
Cut-Away of
MCR300FTPI
Push-In Terminal
Color coded terminals
for consistent, reliable
connections
EASE OF INSTALLATION:
Durable polycarbonate
housing
No more twist-on wire
connectors
Terminal accommodation
#12-#14 AWG, solid only
Copper alloy contacts for
superior wire retention
and minimized heat rise
6", #12 AWG ground
lead with ring terminal
and captive ground screw
Cut-Away of
MCR300FTST
Screw Terminal
Color coded terminal
screws guard caps
50% TIME SAVINGS:
SPD accelerates both roughin & trim out installation
Color coded terminal
screws
Terminal accommodation
#12-#14 AWG, solid or
stranded
How To Order
EFFICIENT DESIGN:
Low profile connection with
feed-through capability
1. Select a Device to ArrowLink
enable. Catalog pages identify
available products-simply add an
"M" to the catalog number and the
devices will be factory enabled with
the ArrowLink device-side connection.
2. Choose from leaded
or unleaded ArrowLink
connector versions in
screw-down or push-in
models.
3. Place your order and get
your ArrowLink devices in
bulk packed boxes,
shipped within 5 days of
receipt of order!
(For GFCIs add “MOD” suffix)
G-2
www.arrowhart.com
30% REDUCTION in wire
volume inside the box
G
SECTION
ArrowLinkTM Modular Connectors
ArrowLink SPD Comparative Labor Savings Analysis
Traditional Pigtail Installation
4:55/Receptacle
Total time required to
install 500 pigtail devices:
0:50
1:50
Cutting & stripping Install wire
pigtails
connectors
1:10
1:05
Terminate
Conductors
Mount
Devices
40.97 Hours
ArrowLink SPD Installation
2:25/Receptacle
Total time required to install
500 ArrowLink SPD devices:
20.13 Hours
1:15
0:05
1:05
Terminate
Conductors
Attach
Device
Mount
Devices
Leaded ArrowLink Receptacle Connectors
Device Type
Description
Catalog No.
Receptacle
Solid Wire Leads – 125V
■ MCR125SOL
Stranded Wire Leads – 125V
■ MCR125STR
Solid Wire Leads– 250V
■ MCR250SOL
Stranded Wire Leads – 250V
■ MCR250STR
Time Saved with SPD
20.84 Hours
MCR125STR
Leaded
ArrowLink
Connector
MCR300FTST
Screw Terminal
ArrowLink SPD Receptacle Connectors
Device Type
Description
Catalog No.
Receptacle
Screw Terminal
■ MCR300FTST
Screw Terminal,
No Ground Conductor
■ MCR300FTSTNG
Push-In
■ MCR300FTPI
Push-In,
No Ground Conductor
■ MCR300FTPING
MCR300FTPI
Push-In
Terminal
Catalog No.
ALTESTER
Circuit Tester
AVAILABLE
SUMMER 2010!
AVAILABLE
SUMMER 2010!
ArrowLink Accessories
Device Type
Description
Circuit Tester
Tests Receptacle &
ArrowLink Connectors
AVAILABLE
SUMMER 2010!
■ ALTESTER
www.arrowhart.com
G-3
SECTION
G
Specification Grade GFCIs
In addition to being tested to the highest standards to help
ensure safety, Arrow Hart GFCIs will deny power and
prevent re-setting if the device is no longer able to provide
safe, protected power.
ShockSentry™ GFCIs provide
state-of-the-art, dependable
electrical shock protection
ShockSentry Ground Fault Circuit Interrupter
Ground termination with
backwire clamp provides
secure wiring and reduces
installation time
Meets and exceeds 10ka
Short Circuit Testing and
Underwriters Laboratories
(UL) 2006 UL943 Safety
standards
Line side terminals are
backed out and staked for
fast installation
Horizontal Test/Reset button
alignment provides larger
unobstructed area
Large visual indicator light
gives quick notification of a
tripped or “end of life”
condition
Unbreakable nylon
construction provides
unsurpassed chemical and
impact resistance
Additional Features and Benefits
• Tapered backwire openings handle multiple wire
sizes and types for applications up to #10 AWG
solid or stranded wire
• Longer, wider “bridge” strap provides 40% more
contact area with wallboard, virtually eliminating
floating installations
• When downstream receptacles are wired from
load side, a 20 amp feed-through rating offers
full protection
• Exclusive built-in wire stripper provides fast
stripping of wire without tools
• Test and reset buttons are color matched to provide
superior aesthetics
• Line-load miswiring protection: Shock Sentry
GFCI’s will not provide power downstream
when wired incorrectly
• Tri-combo head terminal and mounting screws
G-4
www.arrowhart.com
Specification Grade GFCIs
Specification Grade
Ground Fault Circuit
Interrupter Receptacles
1.30"
(33.0mm)
2-Pole, 3-Wire Grounding
15A, 125V/AC
20A, 125V/AC
NEMA 5-15, 5-20
4.19"
(106.4mm)
Hospital Grade GFCIs
Back Wire &
Side Wire
Description
3.28"
(83.3mm)
15A, 125V
NEMA 5-15R
426
Catalog No.
Color Suffix
Hospital GFCI
■ VGFH15___
Hospital GFCI
NAFTA Compliant
■ VGFH15F___
Tamper Resistant
Hospital GFCI
■ TRVGFH15___
Tamper Resistant
Hospital GFCI
NAFTA Compliant
■ TRVGFH15F___
20A, 125V
NEMA 5-20R
426
Catalog No.
Color Suffix
•
•
•
■ VGFH20___
B, GY, LA, RD, V, W
•
•
■ VGFH20F___
B, GY, LA, RD, V, W
•
•
■ TRVGFH20___
•
B, GY, LA, RD, V, W
•
VGFH15
•
B, GY, LA, RD, V, W
B, GY, LA, RD, V, W
•
•
■ TRVGFH20F___
B, GY, LA, RD, V, W
•
1.30"
(33.0mm)
•
•
•
•
B, GY, LA, RD, V, W
•
1.20"
(30.5mm)
•
•
4.19"
(106.4mm)
3.28"
(83.3mm)
B, GY, LA, RD, V, W
Includes standard size unbreakable wallplate
VGFH20_MOD
Depth with
ArrowLink
1.65"
(41.9mm)
1.30"
(33.0mm)
Specification Grade GFCIs
Back Wire &
Side Wire
Tamper Resistant
15A, 125V
NEMA 5-15R
Catalog No.
Color Suffix
Description
Duplex GFCI
■ VGF15___
20A, 125V
NEMA 5-20R
426
426
4.19"
(106.4mm)
Catalog No.
Color Suffix
•
•
A, B, BK, GY, LA, RD, V, W
■ VGF20___
A, B, BK, GY, LA, RD, V, W
3.28"
(83.3mm)
•
•
1.64"
(41.7mm)
Duplex GFCI
■ VGF15___-M
with Mid-Size Wallplate
A, LA, V, W
Duplex GFCI
NAFTA Compliant
■ VGF15F___
Tamper Resistant
Duplex GFCI
■ TRVGF15___
Tamper Resistant
Duplex GFCI with
Mid-Size Wallplate
■ TRVGF15___-M
Tamper Resistant
Duplex GFCI
NAFTA Compliant
■ TRVGF15F___
Weather Resistant
Duplex GFCI
■ WRVGF15___
Tamper & Weather
Resistant
Duplex GFCI
■ TWRVGF15___
TRVGFH15
•
•
•
■ VGF20F___
B, BK, GY, LA, RD, V, W
•
•
■ TRVGF20___
•
B, BK, GY, LA, RD, V, W
•
A, B, BK, GY, LA, RD, V, W
•
•
1.30"
(33.0mm)
•
A, B, BK, GY, LA, RD, V, W
4.19"
(106.4mm)
A, LA, V, W
3.28"
(83.3mm)
•
•
•
■ TRVGF20F___
B, BK, GY, LA, RD, V, W
•
•
•
B, BK, GY, LA, RD, V, W
TRVGF15_MOD
•
•
■ WRVGF20___
B, GY, V, W
•
Depth with
ArrowLink
1.65"
(41.9mm)
1.30"
(33.0mm)
•
B, GY, V, W
•
•
■ TWRVGF20___
B, GY, LA, V, W
•
•
Weather Resistant
B, GY, LA, V, W
Includes standard size unbreakable wallplate unless otherwise noted
Consult factory customer service representative for additional packaging options
4.19"
(106.4mm)
3.28"
(83.3mm)
Color Ordering Information
For ordering devices, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), GY (Gray),
LA (Light Almond), RD (Red), RN (Orange), V (Ivory), W (White)
Icon Key
1.20"
(30.5mm)
WRVGF15
TM
ArrowLink option available. Add "MOD" suffix to
Standard catalog number (example VGF15W,
VGF15WMOD). For ordering information on ArrowLink &
ArrowLink SPD connectors, see page G-2.
Hospital Grade
Build-To-Spec Customizable Devices - see page G-1
NAFTA Compliant - see page O-30
Tamper Resistant
Tamper Resistant
Weather Resistant
Weather Resistant
Tamper & Weather Resistant
Tamper & Weather Resistant
www.arrowhart.com
Specification Information:
Hospital Grade GFCI: G-12
Spec Grade GFCI: G-13
G-5
Specification Grade GFCIs
Specification Grade
Ground Fault Circuit
Interrupter Receptacles
1.30"
(33.0mm)
2-Pole, 3-Wire Grounding
15A, 125V/AC
20A, 125V/AC
NEMA 5-15, 5-20
Specification Grade Automatic Ground GFCIs
4.19"
(106.4mm)
3.28"
(83.3mm)
1.20"
(30.5mm)
VGF15-AG
Back Wire &
Side Wire
15A, 125V
NEMA 5-15R
Description
Catalog No.
Color Suffix
Catalog No.
Color Suffix
Auto Ground
Duplex GFCI
■ VGF15___-AG
■ VGF20___-AG
V, W
Tamper Resistant
Duplex GFCI
■ TRVGF15___-AG
20A, 125V
NEMA 5-20R
426
V, W
426
■ TRVGF20___-AG
BK, V, W
BK, V, W
Includes standard size unbreakable wallplate
1.30"
(33.0mm)
Specification Grade Combination GFCI Receptacle & Switch
15A, 125V
NEMA 5-15R
Back Wire &
Side Wire
4.19"
(106.4mm)
Description
3.28"
(83.3mm)
1.20"
(30.5mm)
426
Catalog No.
Color Suffix
NEMA 5-15 GFCI Receptacle
with Feed-Through Single-Pole
Switch (rated 1800W @ 120V/AC, 60Hz)
■ VGFS15___-MSP
V, W
Includes mid-size unbreakable wallplate
VGFS15-MSP
Specification Grade Blank Face GFCI
1.30"
(33.0mm)
4.19"
(106.4mm)
Back Wire &
Side Wire
20A, 125V
Description
Catalog No.
Color Suffix
Blank Face (Dead Front) GFCI,
Rated as 1.5HP Motor Control Switch
3.28"
(83.3mm)
426
■ VGFD20___
V, W
Includes standard size unbreakable wallplate
1.20"
(30.5mm)
VGFD20
Color Ordering Information
For ordering devices, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), GY (Gray),
LA (Light Almond), RD (Red), RN (Orange), V (Ivory), W (White)
Icon Key
NAFTA Compliant - see page O-30
Tamper Resistant
Tamper Resistant
Accessories for GFCIs
Description
GFCI 7/8” extension ring
Add color suffix: B (Brown), BLK (Black), LA (Light Almond), V (Ivory), W (White))
■ GFER___
Specification Information:
Metal self-closing horizontal 1-gang weather protective cover, decorator opening
■ S1966
Specification Grade
GFCI: G-13
Specification Grade Combo
GFCI Receptacle & Switch: G-14
Specification Grade Blank Face
GFCI : G-14
While-In-Use metal weather protective standard depth 1-gang cover, vertical mount
■ WIUMV-1
GFER
G-6
www.arrowhart.com
S1966
Catalog No.
WIUMV-1
•
•
G
SECTION
Industrial Grade Portable GFCIs
Arrow Hart’s complete offering of portable GFCIs
provide electrical protection from ground fault hazards
on the jobsite.
Reliable GFCI protection in
remote applications
PowerTripTM Portable GFCI
Electro-magnetically latched contacts
will not delatch in rough use conditions
Dual indication lights display power
and fault status
Double insulated user interface
provides added safety for user
Industrial design and materials are UV
and chemical resistant - ideal for use
in rough industrial environments
Heavy-duty cable, plug and connector
provide reliable connection
Convenient plug series
available with flying
leads, single or tri-tap
connector
Available in a variety of
cord lengths, with
terminated devices or
flying leads for field
terminations
Variety of straight blade
and locking plug and
connector options,
including watertight
devices
Available with Manual
or Automatic GFCI
reset options
www.arrowhart.com
G-7
Industrial Grade Portable GFCIs
Industrial Grade
15A Portable
GFCIs
2-Pole, 3-Wire Grounding
15A, 120V/AC
15A Portable GFCIs, Plug Series
Plug Series - Single & Tri-Tap Connector
GFP11M1P3
Rating
A
V/AC
15
120
NEMA
5-15
5-15
5-15
5-15
NEMA
Type
3R
3R
3R
3R
Connector
Style
Single-Tap
Tri-Tap
Single-Tap
Tri-Tap
Cord
Length
2' (0.61m)
2' (0.61m)
25' (7.62m)
25' (7.62m)
Cord
Gauge
12/3 AWG
12/3 AWG
12/3 AWG
12/3 AWG
Catalog No.*
GFP11M1P3
GFP11M1P9
GFP11M4P3
GFP11M4P9
■
■
■
■
*Automatic reset GFCIs are also available. When ordering automatic Portable GFCIs replace “M” in catalog number with “A”.
Example: GFP11A1P3 = Automatic; GFP11M1P3 = Manual.
GFP400
Plug Series - Field Wireable
Rating
A
V/AC
15
120
NEMA
5-15
NEMA
Type
3R
Connector
Style
Flying Leads
Cord
Length
2' (0.61m)
Cord
Gauge
12/3 AWG
Catalog No.*
■ GFP11MNP
*Automatic reset GFCIs are also available. When ordering automatic Portable GFCIs replace “M” in catalog number with “A”.
Example: GFP11ANP = Automatic; GFP11MNP = Manual.
Plug Series - Single Receptacle
Rating
A
V/AC
15
120
GFI11M133
NEMA
5-15
Description
Single Outlet Adapter
Catalog No.
■ GFP400
15A Portable GFCIs, Inline Series
Inline Series - Single & Tri-Tap Connector
Rating
A
V/AC
15
120
GFI11MN3
NEMA
5-15
5-15
5-15
5-15
5-15
5-15
5-15
5-15
NEMA
Type
3R
3R
3R
3R
3R
3R
3R
3R
Connector
Style
Single-Tap
Tri-Tap
Single-Tap
Tri-Tap
Single-Tap
Tri-Tap
Single-Tap
Tri-Tap
Cord
Length
2' (0.61m)
2' (0.61m)
6' (1.83 m)
6' (1.83 m)
25' (7.62m)
25' (7.62m)
50' (15.24m)
50' (15.24m)
Cord
Gauge
12/3 AWG
12/3 AWG
12/3 AWG
12/3 AWG
12/3 AWG
12/3 AWG
12/3 AWG
12/3 AWG
Catalog No.*
■ GFI11M133
■ GFI11M139
■ GFI11M233
■ GFI11M239
■ GFI11M433
■ GFI11M439
■ GFI11M633
■ GFI11M639
*Automatic reset GFCIs also available. When ordering automatic Portable GFCIs replace “M” in catalog number with “A”.
Example: GFI11A133 = Automatic; GFI11M133 = Manual.
Inline Series - Field Wireable
GFP100-B
Rating
A
V/AC
15
120
NEMA
5-15
NEMA
Type
3R
Connector
Style
-
Cord
Length
1’ (0.3m)
Cord
Gauge
12/3 AWG
Catalog No.
■ GFI11MN3*
15
5-15
-
-
-
12-18 AWG
■ GFP100-B**
120
*Automatic reset GFCIs are also available. When ordering automatic Portable GFCIs replace “M” in catalog number with “A”.
Example: GFI11AN3 = Automatic; GFI11MN3 = Manual.
**UL and CSA certified only.
WD3059-DDN
BR20BK
Specification Information:
15A Portable GFCIs: G-15
GFP400 & GFP100-B: G-16
G-8
Accessories for 15A Portable GFCIs
Description
Catalog No.
20A 125V/AC NEMA 5-20, Duplex Straight Blade Receptacle - Black
■ BR20BK
Standard Depth, Portable Outlet Box With Cover Plates
■ WD3059-DDN
www.arrowhart.com
•
•
Industrial Grade Portable GFCIs
Industrial Grade
20A Portable
GFCIs
2-Pole, 3-Wire Grounding
20A, 120V/AC
20A, 240V/AC
20A Portable GFCIs, Inline Series
Inline Series - Field Wireable
Rating
A
V/AC
NEMA
NEMA
Type
Connector
Style
Cord
Length
Cord
Gauge
Catalog No.*
20
N/A
4X
Flying leads
2' (0.61m)
12/3 AWG
■ GFI12M1NN
•
N/A
4X
Flying leads
6' (1.83m)
12/3 AWG
■ GFI12M2NN
•
N/A
4X
Flying leads
25' (7.62m)
12/3 AWG
■ GFI12M4NN
•
N/A
4X
Flying leads
50' (15.24m)
12/3 AWG
■ GFI12M6NN
•
N/A
4X
Flying leads
2' (0.61m)
12/3 AWG
■ GFI22M1NN
•
N/A
4X
Flying leads
6' (1.83m)
12/3 AWG
■ GFI22M2NN
•
N/A
4X
Flying leads
25' (7.62m)
12/3 AWG
■ GFI22M4NN
•
N/A
4X
Flying leads
50' (15.24m)
12/3 AWG
■ GFI22M6NN
•
20
120
240
GFI12M1NN
*Automatic reset GFCIs are also available and are NAFTA compliant. When ordering automatic Portable GFCIs replace “M” in
catalog number with “A”. Example: GFI12A1NN = Automatic; GFI12M1NN = Manual.
Inline Series - Molded Plug & Connector
Rating
A
V/AC
NEMA
NEMA
Type
Plug &
Connector Style
Cord
Length
Cord
Gauge
20
5-20
4X
Molded straight blade
2' (0.61m)
12/3 AWG ■ GFI12M133
•
L5-20
4X
Molded locking
2' (0.61m)
12/3 AWG ■ GFI12M144
•
L6-20
4X
Molded locking
2' (0.61m)
12/3 AWG ■ GFI22M144
•
20
120
240
Catalog No.*
GFI12M133
*Automatic reset GFCIs are also available and are NAFTA compliant. When ordering automatic Portable GFCIs replace “M” in
catalog number with “A”. Example: GFI12A133 = Automatic; GFI12M133 = Manual.
Icon Key
NAFTA Compliant - see page O-30
Accessories for 20A Portable GFCIs
Description
Catalog No.
15A 125V/AC NEMA 5-15 Watertight Plug
■ 14W47
15A 125V/AC NEMA 5-15 Watertight Connector
■ 15W47
Standard Depth Portable Outlet box with Flip Lids
20A 125V/AC NEMA 5-20 Duplex Straight Blade Receptacle - Black
20A 125V/AC NEMA L5-20 Industrial Receptacle
•
•
■ WD3059-DDW •
•
■ BR20BK
•
■ CWL520R
Specification Information:
15W47
WD3059-DDW
BR20BK
www.arrowhart.com
CWL520R
20A Portable GFCIs: G-15
G-9
Industrial Grade Portable GFCIs
Industrial Grade
30A Portable
GFCIs
2-Pole, 3-Wire Grounding
30A, 120V/AC; 30A, 208V/AC
30A, 240V/AC; 30A, 277V/AC
30A Portable GFCIs, Inline Series
Inline Series - Field Wireable, Single Phase
Rating
A
V/AC
NEMA
NEMA
Type
Connector
Style
Cord
Length
Cord
Gauge
Catalog No.*
30
N/A
4X
Flying leads
2' (0.61m)
10/3 AWG
■ GFI13M1NN
N/A
4X
Flying leads
6' (1.83m)
10/3 AWG
■ GFI13M2NN
N/A
4X
Flying leads
25' (7.62m)
10/3 AWG
■ GFI13M4NN
N/A
4X
Flying leads
50' (15.24m)
10/3 AWG
■ GFI13M6NN
N/A
4X
Flying leads
100' (30.48m)
10/3 AWG
■ GFI13M7NN
120
GFI13M1NN
30
208
N/A
4X
Flying leads
2' (0.61m)
10/3 AWG
■ GFI93M1NN
30
240
N/A
4X
Flying leads
2' (0.61m)
10/3 AWG
■ GFI23M1NN
N/A
4X
Flying leads
6' (1.83m)
10/3 AWG
■ GFI23M2NN
N/A
4X
Flying leads
25' (7.62m)
10/3 AWG
■ GFI23M4NN
N/A
4X
Flying leads
50' (15.24m)
10/3 AWG
■ GFI23M6NN
N/A
4X
Flying leads
100' (30.48m)
10/3 AWG
■ GFI23M7NN
N/A
4X
Flying leads
2' (0.61m)
10/3 AWG
■ GFID3M1NN
30
277
*Automatic reset GFCIs are also available. When ordering automatic Portable GFCIs replace “M” in catalog number with “A”.
Example: GFI13A1NN = Automatic; GFI13M1NN = Manual.
Inline Series - Molded Locking Plug & Connector
GFI13M144
Rating
A
V/AC
NEMA
NEMA
Type
Plug & Connector
Style
Cord
Length
Cord
Gauge
Catalog No.*
30
120
L5-30
4X
Molded locking
2' (0.61m)
10/3 AWG
■ GFI13M144
30
240
L6-30
4X
Molded locking
2' (0.61m)
10/3 AWG
■ GFI23M144
*Automatic reset GFCIs are also available. When ordering automatic Portable GFCIs replace “M” in catalog number with “A”.
Example: GFI13A144 = Automatic; GFI13M144 = Manual.
Icon Key
NAFTA Compliant - see page O-30
Accessories for 30A Portable GFCIs
Description
Catalog No.
30A 125V/AC NEMA L5-30 Locking Plug
■ CWL530P •
30A 125V/AC NEMA L5-30 Locking Connector
■ CWL530C •
30A 125V/AC NEMA L5-30 Industrial Locking Receptacle
■ CWL530R •
30A 125V/AC NEMA L6-30 Industrial Locking Receptacle
■ CWL630R •
Standard Depth Portable Outlet Box
■ WD3059
Specification Information:
30A Portable GFCIs: G-15
G-10
CWL530P
CWL530C
www.arrowhart.com
CWL530R
CWL630R
WD3059
•
Industrial Grade Portable GFCIs
2-Pole, 3-Wire Grounding
15A, 120V/AC
20A, 120V/AC; 20A, 240V/AC
30A, 120V/AC; 30A, 240V/AC
Watertight
Portable GFCIs
Watertight Portable GFCIs
Inline Series - Watertight Plug and Connector Ends
Rating
A
V/AC
NEMA
NEMA
Type
Plug &
Connector Style
Cord
Length
Cord
Gauge
Catalog No.*
15
5-15
3R
Straight Blade
2' (0.61m)
12/3 AWG
■ GFI11M155
5-15
3R
Straight Blade
6' (1.83m)
12/3 AWG
■ GFI11M255
5-15
3R
Straight Blade
25' (7.62m)
12/3 AWG
■ GFI11M455
5-15
3R
Straight Blade
50' (15.24m)
12/3 AWG
■ GFI11M655
5-20
4X
Straight Blade
2' (0.61m)
12/3 AWG
■ GFI12M155 •
5-20
4X
Straight Blade
6' (1.83m)
12/3 AWG
■ GFI12M255
5-20
4X
Straight Blade
25' (7.62m)
12/3 AWG
■ GFI12M455
L5-20
4X
Locking
2' (0.61m)
12/3 AWG
■ GFI12M166
L5-20
4X
Locking
6' (1.83m)
12/3 AWG
■ GFI12M266
L5-20
4X
Locking
25' (7.62m)
12/3 AWG
■ GFI12M466
L6-20
4X
Locking
2' (0.61m)
12/3 AWG
■ GFI22M166
L6-20
4X
Locking
6' (1.83m)
12/3 AWG
■ GFI22M266
L6-20
4X
Locking
25' (7.62m)
12/3 AWG
■ GFI22M466
L5-30
4X
Locking
2' (0.61m)
12/3 AWG
■ GFI13M166
L5-30
4X
Locking
6' (1.83m)
12/3 AWG
■ GFI13M266
L5-30
4X
Locking
25' (7.62m)
12/3 AWG
■ GFI13M466
L6-30
4X
Locking
2' (0.61m)
12/3 AWG
■ GFI23M166
L6-30
4X
Locking
6' (1.83m)
12/3 AWG
■ GFI23M266
L6-30
4X
Locking
25' (7.62m)
12/3 AWG
■ GFI23M466
20
20
30
30
120
120
240
120
240
GFI12M155
*Automatic reset GFCIs are also available and are NAFTA compliant. When ordering automatic Portable GFCIs replace “M” in
catalog number with “A”. Example: GFI12A155 = Automatic; GFI12M155 = Manual.
Icon Key
NAFTA Compliant - see page O-30
Accessories for Watertight Portable GFCIs
Description
Catalog No.
20A 125V/AC NEMA 5-20 Watertight Single Straight Blade Receptacle
■ 60W33
•
■ 60W33DPLX •
■ 20PW
•
■ L520RW
•
■ L530RW
•
20A 125V/AC NEMA 5-20 Watertight Duplex Straight Blade Receptacle
20A Plug Closure Cap
20A 125V/AC NEMA L5-20 Watertight Locking Receptacle
30A 125V/AC NEMA L5-30 Watertight Locking Receptacle
60W33
60W33DPLX
20PW
L520RW
www.arrowhart.com
L530RW
Specification Information:
15A Watertight Portable
GFCIs: G-15
20A Watertight Portable
GFCIs: G-15
30A Watertight Portable
GFCIs: G-15
G-11
Hospital Specification Grade GFCIs
Specification & Performance Data
Hospital Specification
Grade Ground Fault Circuit
Interrupter Receptacles
Hospital Grade Duplex GFCI 15A & 20A:
VGFH Series and VGFH__F
ArrowLink: MCR125_, MCR250_, MCR300_ Series
Back & side wire
Integral wire leads, crimped & resistance welded
Backwire feed through
Hospital Grade Tamper Resistant Duplex GFCI 15A & 20A:
TRVGFH and TRVGFH__F Series
ArrowLink: MCR125_, MCR250_, MCR300_ Series
Back & side wire
Integral wire leads, crimped & resistance welded
Backwire feed through
Combined
• cULus Listed to UL 498 and UL 943, file no. E60120
• Meets all UL 943 (GFCI), UL 498 (Receptacles), UL 498
Hospital Grade and applicable CSA requirements
• NOM certified
• Plug & connector cULus Listed to to UL 2459, file no.
E325188
• cULus Listed wiring assembly, UL file no. E326691
• cULus Listed to UL 498 and UL 943, file no. E60120
• Meets all UL 943 (GFCI), UL 498 (Receptacles), UL 498
Hospital Grade and applicable CSA requirements
• NOM certified
• Plug & connector cULus Listed to to UL 2459, file no.
E325188
• cULus Listed wiring assembly, UL file no. E326691
Flammability
Meets UL 94 requirements; V2 rated
Meets UL 94 requirements; V2 rated
Temperature Rating
-35ºC to 66ºC (-31ºF to 150.8ºF)
-35ºC to 66ºC (-31ºF to 150.8ºF)
Flammability
Meets UL 94 requirements; V2 rated
Meets UL 94 requirements; V2 rated
Temperature Rating
-35ºC to 66ºC (-31ºF to 150.8ºF)
-35ºC to 66ºC (-31ºF to 150.8ºF)
Device Type
Testing & Code
Compliance
Wiring
Type
Base Device
ArrowLink
ArrowLink SPD
Base Device
ArrowLink
Base
ArrowLink
Device
Specifications:
Environmental
2-Pole, 3-Wire Grounding
15A, 125V/AC; 20A, 125V/AC
NEMA 5-15, 5-20
Withstands 2000V per UL 498
Yes, at full-rated current
Max. 30ºC (86°F) after 100 cycles of overload @ 150% of rated
Temperature Rise
current (DC)
0.025 seconds (Class A)
Trip Time
60 Hz; Voltage: 125V; Amperage: 15A/20A 20A Feed Through
Frequency
Meets and exceeds 10 kA
Short Circuit Testing
Maximum Interrupting Capacity 20 Amps
ArrowLink
Specifications:
Electrical
Base Device
Dielectric Voltage
Current Interrupting
Max. Working Voltage
Max. Continuous Current
300V/AC
300V/AC
20A
20A
Overload
52.5A/AC for 10 cycles
52.5A/AC for 10 cycles
Dielectric Voltage
Withstands 1600V per UL 2459
Withstands 1600V per UL 2459
Current Interrupting
Limited cycles at full-rated current
Max. 50ºC (122°F) while conducting 35A after 10 cycles of
overload @ 52.5A/AC
Limited cycles at full-rated current
Max. 50ºC (122°F) while conducting 35A after 10 cycles of
overload @ 52.5A/AC
#14 - #10 AWG
#14 - #10 AWG
#12 AWG
#12 AWG
Accepts #12-#14 stranded and solid wire
Accepts #12-#14 stranded and solid wire
Integral THHN #12 AWG 6" lead with ring terminal and #10
ground screw
Permanently marked on device
Integral THHN #12 AWG 6" lead with ring terminal and #10
ground screw
Permanently marked on device
Material: UL recognized insulating material
Dielectric Strength: 2,000V min.
HWI Rating: 4 min.
Relative temperature index, electrical: 80ºC (176ºF)
Flammability: V0 (UL 94)
Material: UL recognized insulating material
Dielectric Strength: 2,000V min.
HWI Rating: 4 min.
Relative temperature index, electrical: 80ºC (176ºF)
Flammability: V0 (UL 94)
Thermoplastic, nylon
Polycarbonate
0.047" thick steel, zinc plated
0.030" thick brass
#8-32 steel, brass plated; neutral screw nickel plated, ground
screw green
0.070" thick steel
Thermoplastic, nylon
Polycarbonate
0.047" thick steel, zinc plated
0.030" thick brass
#8-32 steel, brass plated; neutral screw nickel plated, ground
screw green
0.070" thick steel
Temperature Rise
Specifications:
Mechanical
Base Device Terminal
Accommodation
ArrowLink Wire Leads
ArrowLink SPD Screw
Terminals
ArrowLink SPD Ground
ArrowLink
ArrowLink
SPD
Materials:
Base Device
Specifications:
Screw Terminal
Guards
Voltage Rating
G-12
Withstands 2000V per UL 498
Yes, at full-rated current
Max. 30ºC (86°F) after 100 cycles of overload @ 150% of rated
current (DC)
0.025 seconds (Class A)
60 Hz; Voltage: 125V; Amperage: 15A/20A 20A Feed Through
Meets and exceeds 10 kA
20 Amps
ArrowLink Models Only
Top Housing
Bottom Housing
Strap
Line Contacts
Terminal & Ground Screws
Terminal Clamps
Housing
Polycarbonate
Polycarbonate
Contacts
Copper alloy
Copper alloy
Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
Housing
Polycarbonate
Polycarbonate
Contacts
Copper alloy
Copper alloy
www.arrowhart.com
Specification Grade GFCIs
Specification & Performance Data
Specification Grade
Ground Fault Circuit
Interrupter Receptacles
Combined
Back & side wire
Integral wire leads, crimped & resistance welded
Backwire feed through
• cULus Listed to UL 498 and UL 943, file no. E60120
• Meets all UL 943 (GFCI), UL 498 (Receptacles) and applicable
CSA requirements
• NOM certified
• Plug & connector cULus Listed to to UL 2459, file no.
E325188
• cULus Listed wiring assembly, UL file no. E326691
Specification Grade Tamper Resistant & Weather Resistant
Duplex GFCI 15A & 20A; TRVGF, TRVGF__F, WRVGF, TWRVGF
Series, TRVGF___-AG
ArrowLink: MCR125_, MCR250_, MCR300_ Series
Back & side wire
Integral wire leads, crimped & resistance welded
Backwire feed through
• cULus Listed to UL 498 and UL 943, file no. E60120
• Meets all UL 943 (GFCI), UL 498 (Receptacles) and applicable
CSA requirements
• NOM certified
• Plug & connector cULus Listed to to UL 2459, file no.
E325188
• cULus Listed wiring assembly, UL file no. E326691
Flammability
Meets UL 94 requirements; V2 rated
Meets UL 94 requirements; V2 rated
Temperature Rating
-35ºC to 66ºC (-31ºF to 150.8ºF)
-35ºC to 66ºC (-31ºF to 150.8ºF)
Flammability
Meets UL 94 requirements; V2 rated
Meets UL 94 requirements; V2 rated
Temperature Rating
-35ºC to 66ºC (-31ºF to 150.8ºF)
-35ºC to 66ºC (-31ºF to 150.8ºF)
Dielectric Voltage
Current Interrupting
Withstands 2000V per UL 498
Yes, at full-rated current
Temperature Rise: max. 30ºC (86°F) after 100 cycles of overload
@ 150% of rated current (DC)
0.025 seconds (Class A)
60 Hz; Voltage: 125V; Amperage: 15A/20A 20A Feed Through
Meets and exceeds 10 kA
Voltage: withstands 2000V per UL 498
Yes, at full-rated current
Max. 30ºC (86°F) after 100 cycles of overload @ 150% of rated
current (DC)
0.025 seconds (Class A)
60 Hz; Voltage: 125V; Amperage: 15A/20A 20A Feed Through
Meets and exceeds 10 kA
20 Amps
20 Amps
300V/AC
20A
52.5A/AC for 10 cycles
Withstands 1600V per UL 2459
Limited cycles at full-rated current
Max. 50ºC (122°F) while conducting 35A after 10 cycles of
overload @ 52.5A/AC
300V/AC
20A
52.5A/AC for 10 cycles
Withstands 1600V per UL 2459
Limited cycles at full-rated current
Max. 50ºC (122°F) while conducting 35A after 10 cycles of
overload @ 52.5A/AC
#14 - #10 AWG
#14 - #10 AWG
#12 AWG
#12 AWG
Accepts #12-#14 stranded and solid wire
Accepts #12-#14 stranded and solid wire
Integral THHN #12 AWG 6" lead with ring terminal and #10
ground screw
Permanently marked on device
Integral THHN #12 AWG 6" lead with ring terminal and #10
ground screw
Permanently marked on device
ArrowLink Models Only
Material: UL recognized insulating material
Dielectric Strength: 2,000V min
HWI Rating: 4 min.
Relative temperature index, electrical: 80ºC (176ºF)
Flammability: V0 (UL 94)
Material: UL recognized insulating material
Dielectric Strength: 2,000V min
HWI Rating: 4 min.
Relative temperature index, electrical: 80ºC (176ºF)
Flammability: V0 (UL 94)
Top Housing
Bottom Housing
Strap
Line Contacts
Thermoplastic, nylon
PVC
0.047" thick steel, zinc plated
0.030" thick brass
Terminal & Ground
Screws
#8-32 steel, brass plated; neutral screw nickel plated, ground
screw green
Terminal Clamps
Housing
0.070" thick steel
Thermoplastic, nylon; except WR: nylon 6/6
PVC
0.047" thick steel, zinc plated; WR & TWR: nickel-plated
0.030" thick brass
Terminal: Brass/nickel-plated steel; WR & TWR brass/nickelplated stainless steel; Ground: ground screw green on all models,
WR and TWR stainless steel
Brass-plated steel; WR & TWR nickel-plated steel
Polycarbonate
Polycarbonate
Contacts
Copper alloy
Copper alloy
Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
Housing
Polycarbonate
Polycarbonate
Copper alloy
Copper alloy
Device Type
Base Device
ArrowLink
Base Device
Base
ArrowLink
Device
ArrowLink
Specifications:
Electrical
Specifications:
Environmental
Testing & Code
Compliance
Wiring
Type
Base Device
ArrowLink
ArrowLink SPD
Temperature Rise
Trip Time
Frequency
Short Circuit Testing
Maximum Interrupting
Capacity
Max. Working Voltage
Max. Continuous Current
Overload
Dielectric Voltage
Current Interrupting
Temperature Rise
Specifications:
Mechanical
Base Device Terminal
Accommodation
ArrowLink Wire Leads
ArrowLink SPD Screw
Terminals
ArrowLink SPD Ground
ArrowLink
ArrowLink
SPD
Base Device
Specifications:
Screw Terminal
Guards
Voltage Ratings
Materials:
2-Pole, 3-Wire Grounding
15A, 125V/AC; 20A, 125V/AC
NEMA 5-15, 5-20
Contacts
Specification Grade GFCI 15A & 20A
VGF and VGF__F Series, VGF___-AG*
ArrowLink: MCR125_, MCR250_, MCR300_ Series
*VGF___-AG not available with ArrowLink
www.arrowhart.com
G-13
Specification Grade GFCIs
Specification & Performance Data
Specification Grade
Ground Fault Circuit
Interrupters
Device Type
Specification Grade Combination GFCI
Receptacle & Switch, 15A:
VGFS15, ___-MSP
Specification Grade Blank Face (Dead-Front) GFCI, 20A:
VGFD20 Series
Wiring Type
Back & side wire
Back & side wire
• cULus Listed to UL 498 and UL 943, file no. E60120
• cULus Listed to UL 498 and UL 943, file no. E60120
• Meets all UL 943 (GFCI), UL 498 (Receptacles), UL 20
(Switch) and applicable CSA requirements
• Meets all UL 943 (GFCI), UL 498 (Receptacles), UL 508
(Motor Control) and applicable CSA requirements
• NOM certified
• NOM certified
Flammability
Meets UL 94 requirements; V2 rated
Meets UL 94 requirements; V2 rated
Temperature Rating
-35ºC to 66ºC (-40°F to 150.8°F)
-35ºC to 66ºC (-40°F to 150.8°F)
Dielectric Voltage
Withstands 2000V per UL 498
Withstands 2000V per UL 498
Current Interrupting
Yes, at full-rated current
Yes, at full-rated current
Temperature Rise
Max. 30ºC (86°F) after 100 cycles of overload @ 150% of
rated current (DC)
N/A
Short Circuit Testing
Meets and exceeds 10 kA
Meets and exceeds 10 kA
Terminal Accommodation
#14 - #10 AWG
#14 - #10 AWG
Voltage Ratings
Permanently marked on device
Permanently marked on device
Horsepower Ratings
Switch rated for motor loads per UL 20:
15A: @ 120V/AC = 1/2 HP, max. amps: 12 full-load amps
Rated for motor loads per UL 508:
20A: @ 125V/AC = 1.5 HP, max. amps 20 full load amps
Top Housing
Thermoplastic, nylon
Thermoplastic, nylon
Bottom Housing
PVC
PVC
Strap
0.047" thick steel, zinc plated
0.047" thick steel, zinc plated
Line Contacts
0.030" thick brass
N/A
Terminal & Ground Screws
#8-32 steel, brass plated; neutral screw nickel plated, ground #8-32 steel, brass plated; neutral screw nickel plated, ground
screw green
screw green
Terminal Clamps
0.070" thick steel
Specifications:
Mechanical
Specifications:
Electrical
Specifications:
Environmental
Testing & Code Compliance
Materials:
2-Pole, 3-Wire Grounding
Combo: 15A, 125V/AC Receptacle; 15A, 120V/AC Switch
Dead Front: 20A, 125V/AC
G-14
0.070" thick steel
www.arrowhart.com
Industrial Grade Portable GFCIs
Specification & Performance Data
Industrial Grade
Portable GFCIs
2-Pole, 3-Wire Grounding
15A, 120V/AC
20A, 120V/AC; 20A, 208V/AC; 20A, 240V/AC; 20A, 277V/AC
30A, 120V/AC; 30A, 208V/AC; 30A, 240V/AC; 30A, 277V/AC
Device Type
15A Portable GFCIs
Inline, Plug Series
20A Portable GFCIs
Inline Series
30A Portable GFCIs
Inline Series
Connection Type
Molded plug & connector field wireable,
or watertight plug & connector
Molded plug & connector, watertight plug Molded plug & connector, watertight plug
& connector, or field wireable flying leads & connector, or field wireable flying leads
• Plug & connector ends:
cULus listed to UL943
• Plug & connector ends:
cULus listed to UL943
• Field wireable: UL recognized
component for US & Canada
• Field wireable: UL recognized
component for US & Canada
• OSHA 29 CFR 1926.404 (b)(1)(ii) &
OSHA 29 CFR 1926.405 (a)(2)(ii)(G)
• OSHA 29 CFR 1926.404 (b)(1)(ii) &
OSHA 29 CFR 1926.405 (a)(2)(ii)(G)
• OSHA 29 CFR 1926.404 (b)(1)(ii) &
OSHA 29 CFR 1926.405 (a)(2)(ii)(G)
• NEC 590.6, NEC 511.12, NEC
600.10, NEC 680.5, NEC 680.40
• NEC 590.6, NEC 511.12, NEC 600.10,
NEC 680.5, NEC 680.40
• NEC 590.6, NEC 511.12, NEC 600.10,
NEC 680.5, NEC 680.40
Enclosure Protection
NEMA 3R rated
NEMA 4X rated
NEMA 4X rated
Temperature Rating
-35ºC to 66ºC (-31°F to 150.8°F)
-35ºC to 66ºC (-31°F to 150.8°F)
-35ºC to 66ºC (-31°F to 150.8°F)
Rated Supply Voltage
120V/AC
120V/AC, 208V/AC, 240V/AC, 277V/AC
120VAC, 208V/AC, 240V/AC, 277V/AC
Rated Current/Current
Up to 15A or rating of wiring device
and/or cable
Up to 20A or rating of wiring device
and/or cable
Up to 30A or rating of wiring device
and/or cable
Ground Trip Current
4-6 mA
4-6 mA
4-6 mA
Overload Current
90A @ 125V/AC
120A
180A
Insulation Voltage
4000V – 1 minute
4000V – 1 minute
4000V – 1 minute
Response Time
25 mS max.
25 mS max.
25 mS max.
Let Go Voltage
N/A
60% rated voltage
60% rated voltage
Reset Type
Manual or automatic
Manual or automatic
Manual or automatic
Operating Frequency
60 Hz
60 Hz
60 Hz
GFCI Type
Class A
Class A
Class A
Endurance Operations
3,000 operations
3,000 operations
3,000 operations
Switch Interference
N/A
Double insulated
Double insulated
Latching Mechanism
N/A
Electro-magnetic
Electro-magnetic
Body
Polycarbonate
Polycarbonate & ABS (Gray)
Polycarbonate & ABS (Gray)
Cord
Heavy duty 12/3 SJTW cable
Heavy duty 12/3 SJEOOW cable
Heavy duty 10/3 SJTOW cable
• cULus listed to UL943
Materials:
Specifications:
Mechanical
Specifications:
Electrical
Specifications:
Environmental
Testing & Code
Compliance
www.arrowhart.com
G-15
Portable GFCIs
Specification & Performance Data
Industrial Grade
Portable GFCIs
15A Plug Series
& Inline Series
15A, 120V/AC
Device Type
Single Outlet GFCI Adapter GFP400
Inline Series-Field Wireable GFP100-B
Connection Type
Plug in adapter with NEMA 5-15 receptacle
Field Wireable
• Listed to UL
• UL recognized component
Testing & Code Compliance
Specifications:
Mechanical
Specifications:
Electrical
Specifications:
Environmental
• CSA Certified
Temperature Rating
-35ºC-66ºC (-31ºF to 150.8Fº)
-10ºC-60ºC (-50ºF to 140Fº)
Rated Supply Voltage
15A, 120V/AC
20A, 120V/AC or 10A, 240V/AC
Trip Level
4-6mA
30mA
Response Time
< 25mS
< 25mS
MCOV Protection
205 Joules
3kv ringwave test and 4kV/2kA surge immunity test
Overload Current
6 times rated current
6 times rated current
Insulation Voltage
1500V RMS - 1 minute
1500V RMS - 1 minute
Effect of 10A turn DC shock
on ground fault trip
5% max. trip level variation
N/A
Operating Frequency
50/60 Hz
50/60 Hz
Radio Frequency Noise
Susceptibility
Operates within normal limits with 0.5V injected on power line Operates within normal limits with 0.5V injected on power line
150mHz-230mHz
150mHz-230mHz
Ground Neutral
40 Ohms typical
N/A
Endurance Operations
3,000 operations min.
5,000 operations min.
Wire Accommodations
N/A
#12 - #18 AWG, SJT
Power Indicator
Mechanical, indicates power on
Lighted, indicates power on
G-16
www.arrowhart.com
Download