TRX Three Phase Central Lighting Inverters – 10-30KVA FEATURES • I N V E RT E R S • • • • • • • AC output provides full lumen output for emergency lighting loads in commercial or industrial applications Compatible with any lighting load including incandescent, HID, fluorescent, and LED lamps Painted steel, small footprint enclosure and double conversion online operation Maintenance-free batteries with fully automatic solid state charger Factory startup standard Temperature range: 20°C to 30°C (68°F to 86°F) UL 924 Listed Supports Ethernet and RS-485 network protocols such as SNMP, HTTP, Email, SMS, Modbus and BACnet ORDERING INFORMATION TRX MODEL 1 INPUT VOLTAGE 208VAC 2081 480VAC 480 INPUT CONDUCTOR 31 3 Wire 4 4 Wire CAPACITY 10 10KVA/KW 15 15KVA/KW 20 20KVA/KW 30 30KVA/KW Only available with 208VAC output voltage. ELECTRONICS • • • • • • Uninterruptible "no break" transfer Microprocessor controlled pulse width modulation (PWM) using IGBT technology Transient surge, LVD, short-circuit, current limiting, overload and brown-out protection True sine wave output; optional runtime available Digital controls with graphic user interface, LED indicators and audible alarm system Load power factor range of 0.5 lag to 0.9 lead OUTPUT VOLTAGE 208 208/120VAC 480 480/277VAC OPTIONS SFK Seismic Floor Kit EXP Export Package FTR Certified Factory Test Report IRB Intel Slot Relay Board TRX Three Phase Central Lighting Inverters – 10-30KVA SPECIFICATIONS System Rating Voltage (VAC) AC input Battery AC Output Current(A) Weight Heat Dis. kVA kW Input Output Nnm Max Rec. OCPD Nom. VDC Max Discharge Nom. Rec. OCPD No. of Cabinets Cabinet Config W x D x H, in lb BTU/HR TRX-208-4-10-208 10 10 208 208/120 30 34 45 288 47 28 40 3 A 44.1 x 39.4 x 78.7 2400 2217 TRX-480-3-10-208 10 10 480 208/120 13 15 20 288 47 28 40 3 A 59.8 x 39.4 x 78.7 2400 3855 TRX-208-3-10-208 10 10 208 208/120 31 36 45 288 47 28 40 3 A 59.8 x 39.4 x 78.7 2400 2217 TRX-480-4-10-480 10 10 480 480/277 13 15 20 288 47 12 15 4 C 67.7 x 39.4 x 78.7 4119 5493 TRX-208-4-15-208 15 15 208 208/120 45 51 70 288 70 42 60 4 B 56.7 x 39.4 x 78.7 4116 3245 TRX-480-3-15-208 15 15 480 208/120 20 23 30 288 70 42 60 4 B 72.4 x 39.4 x 78.7 4116 5258 TRX-208-3-15-208 15 15 208 208/120 46 53 70 288 70 42 60 4 B 72.4 x 39.4 x 78.7 4116 3245 TRX-480-4-15-480 15 15 480 480/277 20 23 30 288 70 18 25 5 D 80.3 x 39.4 x 78.7 5583 7271 TRX-208-4-20-208 20 20 208 208/120 59 68 90 288 93 56 70 4 B 78.7 x 39.4 x 78.7 5638 3843 TRX-480-3-20-208 20 20 480 208/120 27 31 40 288 93 56 70 4 B 94.5 x 39.4 x 78.7 5638 6576 3843 TRX-208-3-20-208 20 20 208 208/120 62 71 90 288 93 56 70 4 B 94.5 x 39.4 x 78.7 5638 TRX-480-4-20-480 20 20 480 480/277 27 31 40 288 93 24 30 5 D 102.4 x 39.4 x 78.7 6815 9309 TRX-208-4-30-208 30 30 208 208/120 89 102 150 288 140 83 110 4 B 100.8 x 39.4 x 78.7 7330 6189 11137 TRX-480-3-30-208 30 30 480 208/120 40 46 60 288 140 83 110 4 B 116.5 x 39.4 x 78.7 7330 TRX-208-3-30-208 30 30 208 208/120 93 107 150 288 140 83 110 4 B 116.5 x 39.4 x 78.7 7330 6189 TRX-480-4-30-480 30 30 480 480/277 40 46 60 288 140 36 45 5 D 124.4 x 39.4 x 78.7 8773 16085 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. I N V E RT E R S Dimensions Ordering Number NOTES FOR SITE PLANNING DATA: ADDITIONAL NOTES: Input and bypass cables must be run in separate conduit from output cables • If site configuration includes a backup emergency generator, it is recommended Dual-Lite Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground that the engine generator set be properly sized Dual-Lite and equipped for a UPS TRX Maintenance conductors are recommended. Neutral conductors to be sized for full capacity per TRX an isochronous Battery Bypass Maintenance governor application. Generator options would typically include NEC 310-15(B)(4). References are to NEC 2008. Cabinet Cabinet Battery Bypass (generator frequency regulation) and a UPS compatible regulator (generator Cabinet Cabinet Wiring requirements: voltage regulation). Consult generator manufacturer for required generator AC Input: 3-phase, 4-wire, plus ground options and sizing. AC Output: 3-phase, 3- or 4-wire, plus ground A A refer to Power All wiring is to be in accordance with national and local electrical codes. • If site configuration includes an automatic transfer switch, Line titled “Criteria for Application of Automatic Transfer Switches (ATS) With Minimum cabinet access clearance: 3 ft. (0.9m) front, 18 in. (457mm) overhead. Uninterruptible Power Supply (UPS) Systems,” publication 91K-PLT-48-02. It is Top or bottom cable entry through removable access plates. Punch plate to suit conduit size, then replace. also recommended that the transfer switch be equipped with auxiliary contacts for inverter “on generator” current limit. Consult transfer switch manufacturer for Control wiring and power wiring must be run in separate conduit. Dual-Lite required transfer switch options and sizing. Output voltage is from BDC output Dual-Lite TRX Maintenance Dual-Lite TRX Dimensions are system dimensions including UPS, bypass, transformer and battery • Bypass If site configuration requires an external isolated maintenance bypass circuit, it Maintenance Battery TRX Battery Bypass Maintenance Cabinet Cabinet cabinets;Battery bypass cabinets are front access. should be noted that utility AC input might not be in phase with the UPS AC output. Cabinet Cabinet Cabinet Battery Battery Bypass Cabinet Cabinet Cabinet Weights are system weights including UPS, bypass, transformer and battery Consult a Hubbell Lighting, Inc. sales representative or applications engineer. cabinets. Heat dissipation of UPS and transformer cabinets. A B B Recommended AC input external overcurrent protection is based on 80% rated devices and maximum input current limit settings. Dual-Lite TRX Dual-Lite TRX Battery Battery Cabinet Maintenance Bypass Cabinet Cabinet Battery Cabinet Dual-Lite TRX Dual-Lite Battery TRX Cabinet Maintenance Bypass Cabinet Battery Cabinet B Maintenance Bypass Cabinet Transformer Cabinet Battery Cabinet Dual-Lite TRX Maintenance Bypass Cabinet Battery Cabinet B Transformer Battery Cabinet Cabinet D Dual-Lite TRX Maintenance Bypass Cabinet Battery Cabinet C A Battery Cabinet Mechanical Data Current (A) Dual-Lite TRX Transformer Cabinet C Transformer Cabinet C Dual-Lite TRX Maintenance Bypass Cabinet Maintenance Bypass Cabinet Battery Cabinet Battery Cabinet Maintenance Bypass Cabinet Transformer Cabinet D