HEATING CABLE TYPE SCBX Parallel circuit heating cable - Constant watt for hazardous areas Certificate NO SIRA 03 ATEX 3376U Parallel circuit heating cable is designed to be cut from reel lengths and site terminated to suit pipework. The heating cable consists of a number of short heating zones, each connected across a pair of continuous bus-wire conductors. Each complete heating zone will give its full rated design output with circuit voltage applied to the bus-wire conductors. Construction The heating cable has a core comprising two bus-wire conductors contained within an extruded silicone rubber sheath. The sheath is notched on alternate sides at predetermined intervals to expose a short section of bus-wire conductor. Nickel-chrome resistance wire is wrapped at regular spacing around the core as a continuous conductor, making contact with the bus-wires at the exposed points. After completion of the heater conductor wrapping, a high temperature soldered joint is made at each contact point ensuring that a number of conductor strands are securely bonded to the buswires. An extruded outer sheath of silicone rubber is then placed over the core and heater element to complete the heater cable assembly. Bus-wire conductors Insulation Soldered joint Heating element Outer sheath Over Braid (B) Over Jacket (OJ) The cable has an earth screen outer braid of tinned copper or stainless steel. Where additional protection is required for corrosive conditions extruded silicone rubber sheathing can be placed over the braided cover. 1 (3) Web: www.ihpheating.com - E-mail: info@ihpheating.com - Phone: +46 (0)31 795 30 30 - VAT: SE556689732701 HEATING CABLE TYPE SCBX Range Type Volts Watt/m Heather zone length (m) Max circuit length (m) SC 8 110 8 1,0 110 SC 12 110 12 1,0 80 SC 16 110 16 1,0 75 SC 20 110 20 1,0 69 SC 30 110 30 1,0 60 SC 8 240 8 1,0 250 SC 12 240 12 1,0 170 SC 16 240 16 1,0 145 SC 20 240 20 1,0 120 SC 30 240 30 1,0 105 Specification Conductors Core Heater element Solder Outer sheath Copper stranded flexible -30/0,25mm (1,5mm²) Silicone rubber Nickel-chrome 80-20 High melting point 296°C Silicone rubber Width 13,3mm (Braided version) Thickness 9,5mm (Braided version) Heater zone Braid 1m Tinned copper Temperature range -60°C to +200°C Standard To BS EN 60079 Min bend radius 25mm SIRA 03ATEX3376U 2 (3) Web: www.ihpheating.com - E-mail: info@ihpheating.com - Phone: +46 (0)31 795 30 30 - VAT: SE556689732701 HEATING CABLE TYPE SCBX Electrical Heater zone Heater zone Rated voltage Insulated bus-wire end Rated voltage – 220V/240V or 110V/120V AC/DC Heater zone 1m A 30mA trip Residual Current Circuit Device (RCCD) or Earth Leakage Circuit Breaker (ELCB) is recommended for use with heating cables. Maximum temperature within appropriate T class Maximum temperature of surface to be heated ˚C within Type Appropriate T class T6 T5 T4 T3 SCBX 8 110V 52 70 112 188 SCBX 12 110V - 50 95 173 SCBX 16 110V - - 76 158 SCBX 20 110V - - 55 144 SCBX 30 110V - - - 80 SCBX 8 240V 52 70 112 187 SCBX 12 240V - 50 95 173 SCBX 16 240V - - 76 158 SCBX 20 240V - - 55 144 SCBX 30 240V - - - 93 3 (3) Web: www.ihpheating.com - E-mail: info@ihpheating.com - Phone: +46 (0)31 795 30 30 - VAT: SE556689732701