SUPER LENSLUX 218/7 - Edison Price Lighting

advertisement
SUPER LENSLUX 218/7
Spec Sheet
®
recessed compact
fluorescent
lensed
COMPACT
FLUORESCENT
1-560
downlight
Features
Super Lenslux 218/7 is a 7” aperture downlight designed for use with
two 18-watt, 4-pin compact fluorescent lamps and a regressed prismatic
lens. The 100% acrylic, pattern 32 lens minimizes aperture brightness.
Recess depth is only 4 ¾”.
Super Lenslux 218/7 may be ordered with two lens options: a diffuse white
or a Corolux® double wallwashing lens for corridor lighting. All three lens
types are also available with impact resistance: the prismatic and diffuse
white in Acri-Tuf® and the Corolux lens in Perspex® CP-927.
Regressed trims are available in clear, natural aluminum in two finishes:
slightly diffuse (V) or fully diffuse (EC). Champagne gold, wheat, pewter,
Requires ceiling opening of 7 15/16” (202mm)
In inaccessible ceilings, a total depth of 5 3/4” (146mm) is required to allow ballast removal.
PRODUCT CODE
For complete product code, list basic unit and select one item from each following box.
bronze, white and black finishes are also available.
Basic Unit...................................................................SLLX 218/7
Super Lenslux 218/7 includes a pair of mounting bars (¾” x 27” C
Voltage
120 volt service...................................................................120
277 volt service.................................................................. 277
channel). Specialty bars for wood joist and T-bar installations are available as accessories.
Regressed Trim and Flange Color
Slightly diffuse Clear............................................................ VOL
Fully diffuse Clear............................................................. ECOL
Champagne Gold...............................................................GOL
Wheat............................................................................WHOL
Pewter................................................................................POL
Bronze............................................................................... ZOL
White...............................................................................WOL
Black..................................................................................BOL
Other regressed trim finishes are available on special order.
Applications
Fixture is recommended for downlighting in offices, lobbies, corridors,
restrooms and public areas. Its shallow recess depth allows mounting in
constricted plenum situations. The optional Corolux lens is recommended
for corridor applications, illuminating opposing walls while minimizing
brightness down the sightline of the corridor.
Fixture is
Standard reflector flange continues reflector finish. White painted flanges and custom painted
flanges are available on special order. Add WF (white flange) or CCF (custom color flange).
listed for Damp Location (may not be suitable for some outdoor
environments). Fixture is prewired with high power factor Class P electronic
ballast, suitable for use in a fire rated ceiling, and approved for eight #12
Flush trim not available.
OPTIONS
the ballast and
Specify by adding to the basic unit.
Impact-resistant prismatic lens: Acri-Tuf pattern 12 .................... – PX
Diffuse white acrylic: Frost Glaze®. ..............................................– D
Impact-resistant diffuse white acrylic: Acri-Tuf............................– DX
Corolux lens: double wallwashing lens for corridors . ................. – C
junction box.
Impact-resistant Corolux lens: Perspex CP-927.............................– CX
wire 75°C branch circuit pull-through wiring. Removal of the reflector/
lens assembly allows access to
Diffuse
White
Prismatic
Lens (standard)
Corolux
Lens
Dimmable 3-wire ballast. Not for outdoor application ..............– DM
Emergency battery pack operates lamp in event of
power outage. Fixture footprint increases to 10 x 17 ¾”
(254 x 451mm). An additional 3 ½” (89mm) is
required to remove EM pack through aperture.
No through wiring. Not for outdoor application ...................... – EM
MODIFICATIONS AVAILABLE
Contact factory with quantity for pricing; orders may require shop drawing approval.
CHP-: fixture suitable for Chicago Plenum; add CHP- as prefix to Product Code.
CONC-: fixture suitable for poured-in-place concrete; add CONC- as prefix to
Product Code.
EXP-:`European-style´ install-from-below fixture; add EXP- as prefix to Product Code.
+2”CLG: fixture suitable for installation in 2” thick ceiling material; add +2”CLG to Product Code.
+DOD-:fixture suitable for high humidity environments.
+MAR-:reflector suitable for marine environments.
For combinations of the Options above, contact factory or Edison Price Lighting representative.
A modified fixture suitable for 347-volt service is available on special order. Contact factory.
41-50 22ND STREET, L IC NY 11101
©
Copyright, Edison Price Lighting 2015
®
tel
718.685.0700 fax 718.786.8530 www.epl.com
Lenslux and Corolux are trademarks of Edison Price Lighting
Patented
1:15
Super LENSLUX 218/7
PHOTOMETRIC REPORT
Report No. 41349. Original Independent Testing Laboratories, Inc. (ITL) test report furnished upon request.
Luminaire................ recessed compact fluorescent downlight with white top reflector; semi-specular formed main reflector,
KSH-32® prismatic lens
Lamps..................... two 18-watt double-tube, 4-pin, G24q-2 base, 1250 lumens each
Efficiency................ 35.4%
Spacing Criteria...... 0°-1.2, 90°-1.2, 180°-1.1
Axis orientation....... 0° plane is parallel to lamps, opposite sockets
Photometric Report for Super Lenslux 118/7 available on request.
ZONAL LUMEN SUMMARY
CANDLEPOWER DISTRIBUTION(Candela)
Zone
Lumens
% Lamp
% Fixture
0- 30°
442
17.7
49.9
0- 40°
666
26.6
75.4
0- 60°
854
34.1
96.6
0- 90°
884
35.4
100.0
LUMINANCE DATA
Vertical
Angle
Average
0° Longitude
45
55
65
75
85
Horizontal Angle
Vertical Angle
0.0
45.0
90.0
135.0
180.0
(Candela/m2)
Average
Average
90° Longitude 180° Longitude
8134
3794
1747
751
0
8903
4268
2023
1201
0
7914
3997
1931
1051
0
0
10
20
30
40
50
60
70
80
90
580
575
533
444
248
88
33
14
0
0
580
573
537
444
264
108
32
14
0
0
580
580
549
466
269
98
36
15
0
0
580
564
525
430
247
104
32
14
0
0
580
564
511
415
225
88
34
14
0
0
color multipliers
To convert cd/m to footlamberts multiply by 0.2919.
2
Slightly diffuse Clear (V)
.95 Wheat (WH)
Fully diffuse Clear (EC)
.88 Pewter (P)
.79
.81
Champagne Gold (G)
.97
Bronze (Z)
.58
COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD
Effective Floor Cavity Reflectance 20%
Ceiling Reflectance (%)
Wall Reflectance (%)
70
50
30
10
0
50
80
30
10
70
50
70
30
10
50
30
10
50
30
10
50
30
10
0
42
39
35
32
29
27
25
23
21
20
19
42
38
33
30
27
25
22
20
19
17
16
42
37
32
28
25
23
21
19
17
16
15
41
39
36
34
32
30
28
26
25
23
22
41
38
35
32
29
27
25
23
21
20
18
41
37
33
30
27
24
22
20
19
17
16
41
36
32
28
25
23
20
19
17
16
15
39
36
33
31
28
26
24
22
21
19
18
39
36
32
29
26
24
22
20
19
17
16
39
35
31
28
25
22
20
19
17
16
14
38
35
32
30
27
25
23
22
20
19
18
38
34
31
28
26
24
22
20
18
17
16
38
34
30
27
24
22
20
18
17
16
14
36
34
31
29
27
25
23
21
20
19
17
36
33
30
28
25
23
21
20
18
17
16
36
33
30
27
24
22
20
18
17
16
14
35
32
29
26
24
21
19
18
16
15
14
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
42
40
37
35
33
31
29
27
25
24
22
LENS MULTIPLIERS
Code
Lens
BALLAST INFORMATION
Multiplier
-PX
Impact-resistant prismatic
1.1
-D
Diffuser
0.8
-DX
Impact-resistant diffuser
0.8
To estimate candlepower distribution or luminance data of
fixture with an optional lens, use the appropriate multiplier.
Test report for Corolux lenses available on request.
Voltage
120
Input Watts
36
36
Line Current (A)
.34
.14
Power Factor (%)
>99
>99
Min. Starting Temp* (°F)
0
277
0
*Consult lamp manufacturers for specific temperatures.
Download