SUPER LENSLUX 218/7 Spec Sheet ® recessed compact fluorescent lensed COMPACT FLUORESCENT 1-560 downlight Features Super Lenslux 218/7 is a 7” aperture downlight designed for use with two 18-watt, 4-pin compact fluorescent lamps and a regressed prismatic lens. The 100% acrylic, pattern 32 lens minimizes aperture brightness. Recess depth is only 4 ¾”. Super Lenslux 218/7 may be ordered with two lens options: a diffuse white or a Corolux® double wallwashing lens for corridor lighting. All three lens types are also available with impact resistance: the prismatic and diffuse white in Acri-Tuf® and the Corolux lens in Perspex® CP-927. Regressed trims are available in clear, natural aluminum in two finishes: slightly diffuse (V) or fully diffuse (EC). Champagne gold, wheat, pewter, Requires ceiling opening of 7 15/16” (202mm) In inaccessible ceilings, a total depth of 5 3/4” (146mm) is required to allow ballast removal. PRODUCT CODE For complete product code, list basic unit and select one item from each following box. bronze, white and black finishes are also available. Basic Unit...................................................................SLLX 218/7 Super Lenslux 218/7 includes a pair of mounting bars (¾” x 27” C Voltage 120 volt service...................................................................120 277 volt service.................................................................. 277 channel). Specialty bars for wood joist and T-bar installations are available as accessories. Regressed Trim and Flange Color Slightly diffuse Clear............................................................ VOL Fully diffuse Clear............................................................. ECOL Champagne Gold...............................................................GOL Wheat............................................................................WHOL Pewter................................................................................POL Bronze............................................................................... ZOL White...............................................................................WOL Black..................................................................................BOL Other regressed trim finishes are available on special order. Applications Fixture is recommended for downlighting in offices, lobbies, corridors, restrooms and public areas. Its shallow recess depth allows mounting in constricted plenum situations. The optional Corolux lens is recommended for corridor applications, illuminating opposing walls while minimizing brightness down the sightline of the corridor. Fixture is Standard reflector flange continues reflector finish. White painted flanges and custom painted flanges are available on special order. Add WF (white flange) or CCF (custom color flange). listed for Damp Location (may not be suitable for some outdoor environments). Fixture is prewired with high power factor Class P electronic ballast, suitable for use in a fire rated ceiling, and approved for eight #12 Flush trim not available. OPTIONS the ballast and Specify by adding to the basic unit. Impact-resistant prismatic lens: Acri-Tuf pattern 12 .................... – PX Diffuse white acrylic: Frost Glaze®. ..............................................– D Impact-resistant diffuse white acrylic: Acri-Tuf............................– DX Corolux lens: double wallwashing lens for corridors . ................. – C junction box. Impact-resistant Corolux lens: Perspex CP-927.............................– CX wire 75°C branch circuit pull-through wiring. Removal of the reflector/ lens assembly allows access to Diffuse White Prismatic Lens (standard) Corolux Lens Dimmable 3-wire ballast. Not for outdoor application ..............– DM Emergency battery pack operates lamp in event of power outage. Fixture footprint increases to 10 x 17 ¾” (254 x 451mm). An additional 3 ½” (89mm) is required to remove EM pack through aperture. No through wiring. Not for outdoor application ...................... – EM MODIFICATIONS AVAILABLE Contact factory with quantity for pricing; orders may require shop drawing approval. CHP-: fixture suitable for Chicago Plenum; add CHP- as prefix to Product Code. CONC-: fixture suitable for poured-in-place concrete; add CONC- as prefix to Product Code. EXP-:`European-style´ install-from-below fixture; add EXP- as prefix to Product Code. +2”CLG: fixture suitable for installation in 2” thick ceiling material; add +2”CLG to Product Code. +DOD-:fixture suitable for high humidity environments. +MAR-:reflector suitable for marine environments. For combinations of the Options above, contact factory or Edison Price Lighting representative. A modified fixture suitable for 347-volt service is available on special order. Contact factory. 41-50 22ND STREET, L IC NY 11101 © Copyright, Edison Price Lighting 2015 ® tel 718.685.0700 fax 718.786.8530 www.epl.com Lenslux and Corolux are trademarks of Edison Price Lighting Patented 1:15 Super LENSLUX 218/7 PHOTOMETRIC REPORT Report No. 41349. Original Independent Testing Laboratories, Inc. (ITL) test report furnished upon request. Luminaire................ recessed compact fluorescent downlight with white top reflector; semi-specular formed main reflector, KSH-32® prismatic lens Lamps..................... two 18-watt double-tube, 4-pin, G24q-2 base, 1250 lumens each Efficiency................ 35.4% Spacing Criteria...... 0°-1.2, 90°-1.2, 180°-1.1 Axis orientation....... 0° plane is parallel to lamps, opposite sockets Photometric Report for Super Lenslux 118/7 available on request. ZONAL LUMEN SUMMARY CANDLEPOWER DISTRIBUTION(Candela) Zone Lumens % Lamp % Fixture 0- 30° 442 17.7 49.9 0- 40° 666 26.6 75.4 0- 60° 854 34.1 96.6 0- 90° 884 35.4 100.0 LUMINANCE DATA Vertical Angle Average 0° Longitude 45 55 65 75 85 Horizontal Angle Vertical Angle 0.0 45.0 90.0 135.0 180.0 (Candela/m2) Average Average 90° Longitude 180° Longitude 8134 3794 1747 751 0 8903 4268 2023 1201 0 7914 3997 1931 1051 0 0 10 20 30 40 50 60 70 80 90 580 575 533 444 248 88 33 14 0 0 580 573 537 444 264 108 32 14 0 0 580 580 549 466 269 98 36 15 0 0 580 564 525 430 247 104 32 14 0 0 580 564 511 415 225 88 34 14 0 0 color multipliers To convert cd/m to footlamberts multiply by 0.2919. 2 Slightly diffuse Clear (V) .95 Wheat (WH) Fully diffuse Clear (EC) .88 Pewter (P) .79 .81 Champagne Gold (G) .97 Bronze (Z) .58 COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 20% Ceiling Reflectance (%) Wall Reflectance (%) 70 50 30 10 0 50 80 30 10 70 50 70 30 10 50 30 10 50 30 10 50 30 10 0 42 39 35 32 29 27 25 23 21 20 19 42 38 33 30 27 25 22 20 19 17 16 42 37 32 28 25 23 21 19 17 16 15 41 39 36 34 32 30 28 26 25 23 22 41 38 35 32 29 27 25 23 21 20 18 41 37 33 30 27 24 22 20 19 17 16 41 36 32 28 25 23 20 19 17 16 15 39 36 33 31 28 26 24 22 21 19 18 39 36 32 29 26 24 22 20 19 17 16 39 35 31 28 25 22 20 19 17 16 14 38 35 32 30 27 25 23 22 20 19 18 38 34 31 28 26 24 22 20 18 17 16 38 34 30 27 24 22 20 18 17 16 14 36 34 31 29 27 25 23 21 20 19 17 36 33 30 28 25 23 21 20 18 17 16 36 33 30 27 24 22 20 18 17 16 14 35 32 29 26 24 21 19 18 16 15 14 Room Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 42 40 37 35 33 31 29 27 25 24 22 LENS MULTIPLIERS Code Lens BALLAST INFORMATION Multiplier -PX Impact-resistant prismatic 1.1 -D Diffuser 0.8 -DX Impact-resistant diffuser 0.8 To estimate candlepower distribution or luminance data of fixture with an optional lens, use the appropriate multiplier. Test report for Corolux lenses available on request. Voltage 120 Input Watts 36 36 Line Current (A) .34 .14 Power Factor (%) >99 >99 Min. Starting Temp* (°F) 0 277 0 *Consult lamp manufacturers for specific temperatures.