iWAP101 Universal Zone 1 Access Point Enclosure Zone 1 Access Point enclosure system to allow standard WLAN hardware to be installed in potentially explosive, harsh, wet, and corrosive environments Explosion proof II 2 G EEx d IIB +H2 T5 -20ºC/-10ºC/ to 55ºC (32ºF to 131ºF) note this depends on the internal hardware used. IP66 Overview The iWAP101 Zone 1 Universal Access Point Enclosure is designed to deploy wireless networks in hazardous areas. The concept allows installation of equipment from leading WLAN vendors such as Aeroscout, Meru, Symbol, Cisco, Firetide and many others. Each type of Access Point or RF transmitting device is rigorously checked and tested by Extronics and or Notified Body to ensure conformity to the ATEX standards and approvals. This means that you can effectively use the vendor of your choice when you want to extend your WLAN to your hazardous areas, but equipment not already on the list overleaf needs assessment to determine if it is suitable. The Extronics iWAP101 requires one or two high quality Ex e increased safety antennas. To be used with one or two Ex e antennas (not included) e.g Extronics iANT100 series for optimum coverage on Chemical Plants, Oil Refineries or Oil & Gas Platforms. Optional features include surge arrestors for lightening suppression in outdoor installations and fibre optic inputs for the Ethernet. Features and Benefits Specification Multi Vendor Platform Providing your preferred WLAN or RF hardware is within certain size, volumetric and power dissipating constraints we can install the hardware in our factory. Power Supply 24VDC, 115/230 VAC or POE 802.af compliant Enclosure Material LM6 marine grade alloy with epoxy paint coat Ingress Protection IP66 Weight Approx 15 Kg, hardware dependant Rugged Enclosure Custom enclosure with IP66 ingress protection made from LM6 marine grade aluminium, epoxy painted for installation in extremely arduous environments. Future Proof Infrastructure As new hardware becomes available it can be assessed by Extronics for compliance to the certification and the existing hardware replaced with the new version meaning you are installing a future proof solution. Dimensions 280 x 276 x 214 mm (w x h x d) Ambient Temperature -20ºC/-10ºC/ to 55ºC (32ºF to 131ºF) note this depends on the internal hardware used. Relative Humidity 0 to 95%, non condensing Radio 2.4 GHz direct sequence spread spectrum 802.11 b/g radio. Supports all worldwide WiFi channels 114 subject to local regulations Further data refer to radio vendors specifications Antennas To be used with one or two Ex e antennas (not included) e.g Extronics iANT100 series ATEX Certification EPSILON 06 ATEX 2803 II 2 G EEx d IIB + H2 T5 (Ta 55ºC) or T6 (Ta 40ºC) Ordering Information Refer overleaf for ordering information and options 315835 Issue 10 Ordering Information iWAP101 Universal Zone 1 Access Point iWAP101-[#1]-[#2]-[#3]-[#4]-[#5] Specify option [#1] - Wireless Network Hardware Hardware supplied by customer* Hardware supplied by Extronics 0 1 Specify option [#2] - Type of Wireless Network Hardware Cisco AP1231 Access Point Cisco AP1242 Access Point Cisco AP1242 LAP Light Access Point Symbol AP300 Access Port Single Radio Symbol AP5131 Access Point Single Radio Symbol AP300 Access Port Dual Radio Symbol AP5131 Access Point Dual Radio Meru AP200 Meru AP150 Cisco AP1232 Access Point Cisco AP1231 LWAPP Light Access Point Cisco AP1232 LWAPP Light Access Point AirMagnet A5020 Sensor Firetide 6000Series MESH Router Firetide 6000 Series Mesh Router Dual Radio Firetide Hotport 4500 AP 3 6 7 8 9 10 11 13 14 15 16 18 19 20 21 22 *The iWAP101 can be certified to allow other manufacturers hardware to be installed providing it complies with certain criteria. Send full technical details of your hardware to Extronics for evaluation. Extronics can supply the above certified wireless network hardware ,alternatively you may wish to “free issue” one of the above already certified solutions so that we can factory fit it. Specify option [#3] - Power Supply 24VDC 110 - 230 VAC POE 802.3af compliant (mains power option required with wireless backhaul & fibre network connection options) DC AC UTP Specify option [#4] - Ethernet Connection Multimode Fibre 10/100 base T Ethernet ST Connector CAT5 Cable MM2 UTP Specify option [#5] - Antenna Lightening Protection One Surge Arrestors Fitted Two Surge Arrestors Fitted No Surge Arrestors 1 2 N