Chiller Aermec ANL Data Sheet

advertisement
ANL
Air-cooled water chillers, heat pumps and condensing units
with axial fans:
Cooling capacity from 5,70 up to 43,00 kW
Hating capacity from 6,20 up to 46,00 kW
R410A
Aermec adheres to the EUROVENT
Certification Programme.
The products concerned appear in
the EUROVENT Certified Products
Guide.
• STANDARD VERSION
• VERSION EQUIPPED
WITH WATER PUMP
• VERSION EQUIPPED
WITH WATER PUMP AND
STORAGE TANK
• VERSION WITH BOOSTED
PUMP
• ABILITY TO PRODUCE
DOMESTIC HOT WATER
(D.H.W.)
Features
• Available in 11 sizes
and storage tank
• Cooling only, heat pump, and motocondenANL Q: Version with boosted pump and stosing models
rage tank
• Available in 5 versions:
ANL C: Without evaporator
ANL: Standard Version
• All versions, except the condenser unit and
ANL P: Version equipped with water pump,
the D, can be requested to operate at low
expansion vessel, mechanical water filter
temperature to produce water cooled from 4
ANL N: Version with boosted pump
°C down.
ANL A: Version equipped with water pump, • High efficiency scroll compressors with low
expansion vessel, mechanical water filter,
power consumption
• Differential pressure switch / flow switch as
standard supply
• Electronic control card with compressor starting delay and defrosting cycle control (modu
control).
• High efficiency heat exchangers
• Axial flow fan units for extremely quiet operation
• Metallic protective cabinet with rustproof
polyester paint
Accessories
• BDX: Condensate drip tray for outdoor unit
Only available for 400V-3-phase power supare possible. It can be used with a shielded
• DCPX: Low temperature device for correct
ply. It must be factory set
cable at a distance of 150 m.
cooling mode operation with ambient tempe- • KR: Anti-freeze electric heater for the plate • MODU-485A: RS-485 interface for superviratures from less than 19 °C down to - 10 °C.
heat exchanger, not available for sizes 020 to
sion systems with MODBUS protocol.
• DRE: Current soft starter device (about 30%
040. It must be factory-installed.
• RA: RAntifreeze electric heater for the storage
reduction for single-circuit-units, 26% for • PR3: Simplified remote control panel. All
tank. It must be factory-mounted.
two-circuit-units, 22% for three-circuit-units)
main functions of the unit, alarms included, • VT: Anti-vibration mounts.
Selection
By combining the various options, each model can be configured exactly to match even the most specific system requirements.
Configuration rules:
123
|
Code
456
|
|
|
Size
7
|
Model
8
9
10
11
12
13
|
|
|
|
|
|
|
Heat recovery
| Field of application |
Power supply
|
|
|
Version
Coil fins
Evaporator
Code:
ANL
Size :
020, 025, 030, 041, 050, 070, 080, 090, 100, 150, 200
Model:
° - Cooling only
H - Heat pump
Version:
° - Standard
P - With pump
N - With boosted pump (from 100 up to 200)
A - With pump and storage tank
Q - With storage tank and boosted pump (from 050 up to 200)
Coil fins:
° - Aluminium
R - Copper
S - Tinned copper
V - Painted / aluminium version
Field of application:
° - Standard
Z - Low temperatures of processed water, from 4 up to 0°C
Y - Low temperatures of processed water, from 0°C up to -6°C
Evaporator :
° - Standard
C - Without evaporator
Power supply:
M - 230V ~ 50Hz (only for sizes from 020 up to 040)
° - 400V 3N~ 50Hz
Heat recovery:
° - Without recuperators
D - With desuperheater*
Warning:
– Z-Y = these options apply exclusively to cooling only devices;
– standard options are shown by symbol °;
– heat pump version and the motocondensing version (field 7: option H; field 12: option C);
– single-phase power supply (field 13: option M) is possible for 020 - 025 - 030 - 040 size only;
– * The desuperheater is possible for sizes from 050 to 090 with only accumulation in sizes from 100 to 200 is available in all versions. Option D is
incompatible with the options low temperature, with the version condensing and, for dimensional reasons, even with the option Q
Commercial code example: ANL090HAR
This is a new ANL, size 090, heat pump model, with storage tank and pump, with copper condensing coil, with evaporator, and with electrical box
for compressors with motors 3N~ 400V 50Hz. Note that as each option is precisely identified, it is not necessary to specify standard options
(indicated by ° ) in the commercial code.
Compatibility of accessories
025
030
040
050
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
All versions
PR3
MODU-485A
DCPX 50 (Cooling only)
DCPX 52 (Cooling only)
DCPX 51 (Heat pump)
DCPX 53 (Heat pump)
DRE 5
020
✔
✔
✔
Versions Standard and P (with pump)
BDX 5
KR 2
VT 9
VT 15
020
✔
✔
✔
025
✔
✔
✔
030
✔
✔
✔
Version A
BDX 5
BDX 6
KR 2
RA
VT 9
VT 15
020
✔
✔
✔
-
025
✔
✔
✔
-
Version C
VT 9
VT 15
020
✔
025
✔
✔
✔
070
✔
✔
✔
080
✔
✔
✔
090
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
040
✔
✔
✔
050
✔
✔
✔
070
✔
✔
✔
080
✔
✔
✔
030
✔
✔
✔
-
040
✔
✔
✔
-
050
✔
✔
✔
✔
070
✔
✔
✔
✔
030
✔
040
✔
050
✔
070
✔
✔
✔
100
✔
✔
150
✔
✔
200
✔
✔
✔
✔
✔
✔
✔(X2)
✔
✔(X2)
✔
(X2)
090
✔
✔
✔
100
✔
150
✔
200
✔
✔
✔
080
✔
✔
✔
✔
090
✔
✔
✔
✔
100
✔
✔
✔
150
✔
✔
✔
200
✔
✔
✔
080
✔
090
✔
100
150
200
✔
✔
✔
✔
Technical data
Mod. ANL
Cooling capacity (1)
kW
Total input power (1)
kW
Evaporator water flow rate
Pressure drops
l/h
kPa
Mod. ANL H
Cooling capacity (1)
kW
Total input power (1)
kW
Evaporator water flow rate
Pressure drops
Heating capacity (2)
l/h
kPa
kW
Total input power (2)
kW
Evaporator water flow rate
Pressure drops
l/h
kPa
Version
°-P-A
°
P-A
Q-N
°-P-A
°-P-A
020
5.70
1.84
1.99
980
20
025
6.20
2.00
2.15
1070
20
030
7.50
2.46
2.61
1290
20
040
9.60
3.25
3.40
1650
21
050
13.40
4.03
4.30
4.48
2310
21
070
16.50
4.88
5.15
5.33
2840
21
080
20.50
6.33
6.60
6.78
3530
26
090
22.30
6.63
6.90
7.08
3840
25
100
150
26.60 33.00
8.40 10.00
9.2
11.5
9.4
11.3
4580 5680
43
39
200
43.00
13.70
15.2
15.0
7400
32
Version
°-P-A
°
P-A
Q-N
°-P-A
°-P-A
°-P-A
°
P-A
Q-N
°-P-A
°-P-A
020
5.70
1.84
1.99
980
29
6.2
1.91
2.06
1070
30
025
6.20
2.00
2.15
1070
30
7.0
2.12
2.27
1200
30
030
7.50
2.46
2.61
1290
30
8.4
2.62
2.77
1450
28
040
9.60
3.25
3.40
1650
27
10.6
3.18
3.33
1820
37
050
13.40
4.03
4.30
4.48
2310
30
14.0
4.30
4.57
4.75
2410
30
070
16.50
4.88
5.15
5.33
2840
30
17.3
4.90
5.17
5.35
2980
32
080
20.50
6.33
6.60
6.78
3530
36
22.2
6.30
6.57
6.75
3820
45
090
22.30
6.63
6.90
7.08
3840
50
24.2
6.85
7.12
7.30
4160
53
100
26.0
8.6
9.2
9.6
4470
41
29.0
8.60
9.20
9.60
4990
52
150
32.0
10.2
11.2
11.5
5500
37
35.0
10.10
11.10
11.40
6020
44
200
42.0
13.9
14.9
15.2
7220
31
46.0
13.30
14.30
14.60
7910
37
°
°
°
°
3,09
3,09
3,72
3,24
3,10
3,10
3,72
3,30
3,05
3,05
3,66
3,20
2,95
2,95
3,54
3,33
3,32
3,32
3,99
3,25
3,38
3,38
4,06
3,25
3,23
3,23
3,88
3,52
3,36
3,36
4,03
3,53
3,16
3,02
4,14
3,37
3,30
3,13
4,25
3,37
3,14
3,02
4,12
3,45
6
16.5
7
17.5
26.5
59.5
27.5
60.5
-
6
16.5
7
17.5
32.5
62.5
33.5
63.5
-
6.7
19.7
7.7
20.7
35.7
83.7
36.7
84.7
-
8.7
23.7
9.7
24.7
48.7
98.7
49.7
99.7
-
11.3
13.3
14.0
65.3
67.3
68.0
13.5
15.5
16.2
75.3
77.3
78.0
16.3
18.3
19.0
102.3
104.3
105.0
17.3
19.3
20.0
96.3
98.3
99.0
22.0
23.4
23.4
76.0
77.4
78.8
26.0
28.8
28.8
87.0
89.8
90.5
34.0
36.8
36.8
117.0
119.8
120.5
1/1
1/1
1/1
1/1
2/1
2/1
2/1
1
3500
0,14
0,66
1
3500
0,14
0,66
2
7200
0,28
1,32
ANL/ANL H
EER (ANL)
EER (ANLH)
ESSER
COP
Electrica data ANL/ANL H
Maximum current (FLA)
Maximum current (FLA)
Peack current (LRA)
Peack current (LRA)
Compressor ANL/ANL H
Number / circuit
Fans
Number
Air flow rate
Input power
Input current
Evaporator
Number
Hydraulic connection
Saund data ANL/ANL H
Power pressure
Sound pressure (3)
Hydronic kit ANL/ANL H
Storage tank
Pump (version P - A)
Input power pump
Input current pump
Useful pressure pumping
Pump (version Q-N)
Input power pump
Input current pump
Useful pressure pumping
Hydraulic connection
400V
230V
400V
230V
400V
400V
230V
400V
230V
400V
A
A
A
A
A
A
A
A
A
A
°
°
P-A
P-A
Q-N
°
°
P-A
P-A
Q-N
tipo
n°/n°
° - P - A 1/1
n°
°-P-A 1
(in-out)ø ° - P - A 1”¼
1
1”¼
1
1”¼
1
1”¼
1
1”¼
Scroll
1/1
Axial
2
7200
0,28
1,32
Plate
1
1”¼
n°
m3/h
kW
A
°-P-A 1
1
2500 2500
0,085 0,085
0,45 0,45
dBA
dBA
61.0
30.0
61.0
30.0
68.0
37.0
68.0
37.0
69.0
38.0
69.0
38.0
69.0
38.0
68.0
37.0
76.0
44.0
77.0
45.0
78.0
46.0
25
25
35
35
75
75
75
75
100
100
100
0,15
1,4
60
0,15
1,4
60
0,15
1,4
59
0,15
1,4
55
0,27
1,95
82
0,27
1,95
80
0,27
1,95
69
0,27
1,95
66
0,6
1,2
84
1,0
2,0
115
1,0
2,0
90
-
-
-
-
0,45
2,7
160
1”¼
0,45
2,7
158
1”¼
0,45
2,7
144
1”¼
0,45
2,7
140
1”¼
1,0
2,0
140
1”¼
1,3
2,6
185
1”¼
1,3
2,6
158
1”¼
l
kW
A
kPa
kW
A
kPa
(in-out)ø
A
1/1
1/1
2
7300
0,28
1,32
2
7200
0,28
1,32
1
1”¼
1
1”¼
1
1”¼
1
1”¼
1
1”¼
2
2
2
13200 12000 12000
0,6
0,6
0,6
2,6
2,6
2,6
Technical data
Mod. ANL C
Cooling capacity (1)
Total input power (1)
EER
Version
020
5.70
1.85
3.08
025
6.00
2.05
2.93
030
7.50
2.50
3.00
040
9.60
3.30
2.91
050
13.70
4.10
3.34
070
16.80
5.00
3.36
080
20.80
6.50
3.20
090
22.50
6.80
3.31
A
A
A
A
A
A
3.7
9.5
6.0
16.5
26.5
59.5
4.2
10.0
6.0
16.5
32.5
62.5
4.7
13.0
6.7
19.7
35.7
83.7
6.3
16.3
8.7
23.7
48.7
98.7
8.9
11.3
65.3
-
9.9
13.5
75.3
-
12.4
16.3
102.3
-
13.1
17.3
96.3
-
17.1
22.0
76.0
-
19.3
26.0
87.0
-
26.4
34.0
117.0
-
1/1
1/1
1/1
1/1
1/1
1/1
1/1
2/1
2/1
2/1
1
1
1
Scroll
1/1
Axial
1
2
2
2
2
2
2
2
30.0
30.0
37.0
37.0
38.0
38.0
38.0
37.0
44.0
45.0
46.0
kW
kW
100
150
26.90 33.40
8.70 10.20
3.13 3.27
200
43.70
14.10
3.10
Electrical data
400V
230V
400V
230V
400V
230V
Power supply
Maximum current (FLA)
Peak current (LRA)
Compressor
Number/circuit
Fans
Number
°
°
°-H
°-H
°-H
°-H
tipo
n°/n°
n°
Sound data
Sound pressure (3)
dBA
ANL - ANL H
ANL C
The technical data is calculated as follows:
1) Cooling mode
Temperature water inlet
12 °C
Temperature of processed water
7 °C
Ambient air temperature
35 °C
Δt
5 °C
The technical data is calculated as follows:
1) Cooling mode
Evaporation temperature
5 °C
Ambient air temperature
35 °C
2) Heating mode
Temperature of processed water
Ambient air temperature
Δt
45 °C
b.s. 7 °C
b.u. 6 °C
5 °C
3) Sound pressure measured in free field conditions at distance of 10m and direction factor = 2. In accordance with ISO 3744 regulations.
Dimensions (mm)
C
ANL/ANL H
Height (A)
Width (B)
Depht (C)
A
°eP
mm
mm
mm
kg
kg
020
868
900
310
75
77
025
868
900
310
75
77
030
1000
900
310
86
91
040
1000
900
310
86
91
050
1252
1124
384
120
127
070
1252
1124
384
120
127
080
1252
1124
384
156
163
090
1252
1124
384
156
163
mm
mm
mm
kg
020
868
1124
384
99
025
868
1124
384
99
030
1015
1124
384
103
040
1015
1124
384
103
050
1281
1165
550
147
070
1281
1165
550
147
080
1281
1165
550
183
090
1281
1165
550
183
ANL C
Height (A)
Width(B)
Depht (C)
Weight empty
mm
mm
mm
kg
020
868
900
310
70
025
868
900
310
70
030
1000
900
310
78
040
1000
900
310
78
050
1252
1124
384
110
070
1252
1124
384
110
080
1252
1124
384
141
090
1252
1124
384
141
ANL D-Q
Height (A)
Width(B)
Depht (C)
Weight empty
mm
mm
mm
kg
020
-
025
-
030
-
040
-
050
1281
1165
550
151
070
1281
1165
550
151
080
1281
1165
550
187
090
1281
1165
550
187
Weight empty
020 - 025 - 030 - 040
C
B
A
050 - 070 - 080 - 090
B
A
C
100 - 150 - 200
ANL/ANL H
Height (A)
Width(B)
Depht (C)
Weight empty
ANL all version
Height (A)
Width(B)
Depht (C)
Weight
The technical data in this document are not binding.
Aermec S.p.A. reserves the right to make whatever modifications
it deems necessary to improve the product at any time.
°
P
A
100
mm
1390
mm
750
mm
1750
°-P
kg 270/ 288
H-HP kg 295/313
A - HA kg 338/363
150
1390
750
1750
293/314
322/343
364/393
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293730
www . aermec . com
200
1390
750
1750
329/350
358/379
400/429
Cod.: SANLUY.09 / 1103
B