DCDC Filter & Surge Protection DSF226 Series xppower.com • Up to 200 W Output Power • Active Surge Protection • MILSTD 461 & DEFSTAN 59411 • MILSTD 1275AD • DEFSTAN 615 Part 6 Issue 6 • MILSTD 810 • 3 Year Warranty Specification Input Input Voltage Range Input Transient Input Reverse Voltage Protection Fuse Protection General • 15 - 33 VDC • ±250 V for 70 µs 15 mJ, 100 V for 50 ms 0.5 Ω per MIL-STD-1275A/B/C/D ±600 V for 10 µS per MIL-STD-704A, ±200 V for 100 ns, pulse train, 174 V+Vin for 350 ms per DEF-STAN 61-5 part 6 issue 6 10V for 1 s. • Continuous • External T25 A fuse is recommended Output Output Voltage Output Power Thermal Warning (TW) Maximum Output Capacitor • Tracks input voltage & clamps <36 VDC • 200 W max • The TW output is an open collector transistor rated at 100 VDC, with a maximum sink current of 10 mA, referenced to –V in/-V out. The signal output is low when the maximum base plate temperature is exceeded. This signal indicates an over temperature condition so that action can be taken by the end application such as shutting down non critical loads or individual downstream DC/DC converters. If connected to the DIS pin of the DSF226 this will disable the filter output and perform as a thermal shut down for the system. The TW output will automatically return to a high signal level once the filter base plate has cooled to a temperature of less than 100°C. • 10,000 µF recommended Efficiency Isolation Voltage Series Resistance Disabled Input Current Disable (DIS) No Load Current Package Style MTBF • • • • • 97% typical 500 VDC Input & Output to Case <0.1 Ω <25 mA On = Open circuit Off = Logic low or short circuit • <35 mA • Photo-etched nickel-silver case and aluminium baseplate • >2000 kHrs to MIL-HDBK-217F at 40 °C, GB Environmental Operating Temperature Storage Temperature Salt Atmosphere Humidity Altitude Shock Vibration • • • • • • -46 °C to +100 °C baseplate -55 °C to +100 °C MIL-STD-810F method 509.4 MIL-STD-810F 507.4 MIL-STD-810F 500.4 MIL-STD-810F 516.5 function test for ground equipment 40 g in 3 axes • MIL-STD-810F method 514.5C-17. Minimum integrity test for military equipment (1 Hr/axis, 3 axes). Vibration 5-33 Hz, 0.5 mm displacement EMC & Safety Immunity Emissions Safety Approvals • MIL-STD-1275A-D, MIL-STD-461E/F (CS101, CS114, CS115 & CS116) MIL-STD-704A, DEF-STAN 61-5 part 6 issue 6 • MIL-STD 461E/F CE101, CE102 & DEF STAN 59-411 DCE01/DCE02 with external components. (See application notes and longform datasheet) • CE marked Output Power Input Voltage Output Voltage Typical Efficiency 15-33 VDC <36 VDC 97% 200 W Model Number DSF226 Mechanical Details 0.38 (9.6) 0.20(5.1) 1.33 1.25 (33.9) (31.8) Case Pin Customer mounting holes Ø 3.2mm - 4 places 1.45 (36.8) 1.02 (25.9) 0.82 0.63 (20.9) (15.9) 0.43 (10.9) 0.20 (5.0) 2.21 (56.1) 0.25 (6.4) 0.76 (19.4) Pin Size - 7 Places: Diameter: 0.047 (1.2) Mounting Hole: 0.059 (1.5) Material: Copper - tin alloy Finish: 2.5 mm copper and 2.5 mm 5 N (tin) 0.51 (13.0) 2.41 (61.2) Notes 1. All dimensions in inches (mm). 2. Weights: 0.165 lbs (75 g) 3. Tolerance ±0.012 (±0.3) Application Notes Typical Schematic for DEFSTAN 59411 Compliance 22 nF FUSE +Vin +Vin 24 VDC 2 mH -Vin +Vout +Vin -Vin + 2200 µF 50V DSF226 (1) +Vout MTC50 10 µF 50V -Vin -Vout Load -Vout 22 nF (1) Common mode choke part number W409 core from VAC and 2 x 6 turns, 1.5 mm wire. Typical Schematic for MILSTD461E Compliance 100 nF 47 nF FUSE +Vin 24 VDC -Vin +Vin 1000 µF DSF226 2.2 µF -Vin +Vin +Vout 50V + 100 µF 50V + 10 µF +Vout MTC150 Load 50V -Vin -Vout 100 nF -Vout 47 nF 06-Jan-14 DCDC DSF226 Models & Ratings