Pollution Degree: ductive due to condensation. This is to be expected. Any addition of foreign matter, solid, liquid or gaseous (ionized gases), that may produce a reduction of insulation capabilities, is considered pollution. The pollution degree affects the creepage and clearance values. The degree of pollution is broken down as follows: Level 1: No pollution or only dry non-conduc tive pollution occurs. Level 2: Normally only non-conductive pollu tion occurs. Temporary conductivity caused by condensation is to be expected. Level 3: Conductive pollution occurs, or dry non-conductive pollution, which becomes con- Level 4: The pollution generates persistent conductivity caused by conductive dust, rain or snow. The IEC 61010 Standard includes tables that tie the above criteria together. This allows one to design, test, and classify hand-held probe assemblies pertinent to the application. Two such excerpts from tables appear below. They have been included to illustrate how a probe can satisfy two separate classifications. (i.e.- a 600V, CAT III and a 1000V, CAT II can be equally satisfied with a single design.) DOUBLE INSULATION Working Voltage (r.m.s. or d.c.) up to V 300 600 1000 Pollution Degree 2 Installation Category (overvoltage category) II Clearance mm 3.3 6.5 11.5 Test Voltage, V Creepage Distance, mm For Use In Equipment Material Group I CTI>600 II CTI>400 II CTI>100 3.3 6.5 11.5 4.2 8.5 14.0 6.0 12.0 20.0 Peak Impulse 1,2/50 µs r.m.s. 50/60 Hz 1 min d.c. or 50/60 Hz peak 1 min 4250 6800 10200 2300 3700 5550 3250 5250 1000 DOUBLE INSULATION Working Voltage (r.m.s. or d.c.) up to V 300 600 1000 Pollution Degree 2 Installation Category (overvoltage category) III Clearance mm 6.5 11.5 16.0 Test Voltage, V Creepage Distance, mm For Use In Equipment Material Group I CTI>600 II CTI>400 II CTI>100 6.5 11.5 16.0 6.5 11.5 16.0 6.0 11.5 20.0 Peak Impulse 1,2/50 µs r.m.s. 50/60 Hz 1 min d.c. or 50/60 Hz peak 1 min 6800 10200 13600 2700 5550 7400 3250 7850 10450 References: http://www.technology.niagarac.on.ca/courses/elnc236/dmmsafet/tsld009.htm IEC 61010 Standard 1583 East 31st Street u Cleveland OHIO u 44114 Toll Free (U.S.) 1.800.955.2629 u Phone: 216.771.5225 u Fax: 216.771.3068 website: www.muellerelectric.com © 2001 Mueller Electric Company