AIR HANDLERS LTD Air Handling Packaged Units Envirofresh Tempered full fresh air heat pumps with recovery. System Benefits • Fully factory tested systems, pre-wired complete with integral refrigeration components and all controls. • Reduces site installation costs and time. • Lower external noise levels. • Energy saving heat recovery system. • No external condensing units. • Available with volumes from 0.5m3/s to 7.0m3/s. Applications • Lecture theatres, meeting and function rooms. • Where occupant fresh air requirement exceeds design cooling. • Combine with other system such as VRV, split systems and chilled water fan coils to provide tempered fresh air. Envirofresh Freshcool Full fresh air packaged cooling system. System Benefits Control Panel • No external condensing units. • 3 steps of capacity control. • Reduced site installation time. • Components selected for optimum operation. • Capacities from 10kW to 105kW. • Refrigerant gas in system kept to a minimum. • Fully pre-wired control system. • Competitively priced against remote condensing units. Alternative to F Gas The Envirofresh and Freshcool are available with environmentally friendly Hydrocarbon refrigerant. Combine with VRV or chilled water systems to reduce F gas volumes. 05 AIR HANDLERS LTD About Air Handlers Air Handlers have designed and manufactured air handling equipment since 1989. Our manufacturing plant and headquarters are based in Manchester, where we also manage all design and development of new products. Our Mission Air Handlers develop and manufacture air handling products tailored to meet customer requirements. We are committed to providing equipment and service of the highest quality, working closely with clients to provide environmental product solutions through technical expertise. Current Products and Services • Twin Extract Units VSI, VTI and ITU • Flat Series Void Units FPVU • Packaged Void Units PVU • AH Series Modular AHU’s • IDG Series Indirect Gas Fired AHU’s • DG Series Direct Gas Fired AHU’s • HOSP Health care Specification Hygiene AHU’s • AHW Welded Frame and Stainless Units • TWHR Heat Reclaim AHU’s containing Thermal Wheels • AHR Heat Recovery AHU’s containing Recuperators • Freshcool Cooling only Packaged Units • Envirofresh Packaged Heat Pump Units • Attentuators and Anti-vibration Mounts • Acoustic Enclosures and Screens • Flat Pack AHU Build • AHU Refurbishment Air Handlers Northern Ltd. Alfred Procter House, Bute Street, Salford, Manchester M50 1DU Tel: 0161 745 8888 Fax: 0161 745 9900 Email: sales@airhandlers.net Web: www.airhandlers.net The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Air Handlers Northern Ltd is continually developing and improving its products. All description, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are subject to the company’s General Conditions of Sale, a copy is available on request. AIR HANDLERS LTD Classvent Engineering Solutions AIR HANDLERS LTD Air Handling Units Product Information AH Range of Bespoke Units Hospital Unit • A range of units of modular construction available with volumes from 0.25 to 50m3/s. • Frames of pentapost construction in aluminium or steel. • Includes a complete range of heat recovery, cooling, heating, fan systems and air-handling functions. • Units supplied to NHS specification HTM 03-01. PVU Ceiling Void Units • A range of units for ceiling void application. • Available with volumes up to 1.4m3/s. • Includes a complete range of plate heat exchangers, cooling, heating, direct driven fans and air-handling functions. • Low breakout casework available. • Low profile units of 300mm high up to 0.8m3/s. low Profile Unit VTI and ITU Twin Toilet Extract • Run and standby twin toilet extract fans. • Direct driven with fan speed control up to 1.8m3/s. • Belt driven up to 5m3/s. • Supplied complete with change over control panel and fan contactors. Direct Driven Fan Section 02 AIR HANDLERS LTD Case Study: Chorlton High School Chorlton High School, based in Greater Manchester was given a new lease of life in 2003 with a refurbishment and installation of a natural ventilation system. Soon after, complaints of overheating and muginess were reported by the teachers and in August 2005, Manchester City Council approved the installation of the Classvent system as a trial in one of the classrooms. Temperatures and CO2 levels were monitored and compared to the adjacent classroom in which the original natural ventilation system remained. Below is a graph indicating daily results. Assessment of Internal CO2 concentrations in Mechanical Ventilated Classrooms (15-09-2005). As illustrated on the left, the mechanical ventilation system (Classvent) holds the CO2 levels below the stipulated 1500 parts per million guideline. Data taken from the naturally ventilated room was taken with the windows open and CO2 levels would rise even further should the windows be closed in the winter months. The trial of the Classvent system in Chorlton High School has been a resounding success. The Classvent units will now be installed in further schools in the area under the Manchester BSF (Building Schools for Future Project. 03 AIR HANDLERS LTD Classvent: Description of System and Operation Concept The Classvent maintains levels of temperature and CO2 with variable control of both air volume and heating. Heat recovery from the exhaust air is transformed to fresh air to reduce the LPHW heating load. The system responds quickly to occupancy changes. When unoccupied the system reverts to energy saving temperature set back mode with full recirculation of air flow. When occupied the system provides uniform distribution of temperature and fresh air. Classvent provides an energy efficient solution to providing a good environment for teaching and learning. Equipment The unit is constructed with 50mm thick double skinned acoustically insulated panels. Each unit is complete with filters, fresh air/recirculation dampers, plate heat exchangers, LPHW heating coil, variable speed supply and extract fans, water pipework, 3 port valve, control panel, sensors, damper actuators and internally wired prior to testing. Boost Ventilation When there is a cooling demand from the space and no cooling is available from the outside air, the supply fan will shut down and the extract run in boost to increase the air change rate within the room. The boost mode will be activated on a predetermined return air set point temperature or a manual teacher operated push button. Night Ambient Air Cooling Heat which is stored in the fabric of the building during the daytime can be removed to reduce the temperature increase during the day. This function is carried out using the lower night time ambient air and operating the unit to obtain the room set point during the night reducing the fabric gain. Classvent Unit Operation Heating The unit will start up in full recirculation mode and the valve to the heating coil fully open to preheat the classroom. On occupancy the system will revert to 100% fresh and exhaust air with room temperature control via the 3 port valve. CO2 Control The fan speed will be controlled to regulate the CO2 level below the stipulated 1500 parts per million level. In low occupancy, when the concentration is below 900 parts per million the fan speed will reduce to save energy. Advantages • Low noise level. • Energy saving heat recovery. • BMS compatible. • Quick response to timetable occupancy changes. • Uniform air distribution. Free Ambient Air Cooling • Increased ventilation rates in summer. In Winter with the high occupancy gains, there could be a cooling demand. The unit will control the room air temperature and lower the supply air off coil temperature to reduce the space temperature and provide free cooling. A low limit supply air temperature of 16°C is set to prevent cold draughts being provided to the area • Unoccupied, reduced temperature set point. 04 • Recirculation air on start up. • Energy saving variable speed fans. • Energy saving fast start up just prior to occupancy. No need for pre-heat time compensation.