TECHNICAL INFORMATION SHEET UC

advertisement
TECHNICAL INFORMATION SHEET
UC-500
Flush Panel For Architectural Soffit & Fascia Systems
TIS #2012
1.4
0.5"
Description:
Firestone UNA-CLAD UC-500 Flush Panel is a factory-formed,
formed, interlocking,
architectural metal panel designed for soffit and fascia applications. The
UC-500
500 Flush Panel offers the design professional a flush or flat
appearance by utilizing an interlocking leg and concealed fastening
system.
1.0
Varies
Method of Application:
1.
2.
3.
A smooth, solid substrate of plywood or OSB, or a substructure of min. 22 ga (0.79 mm), 7/8” (22
(22.3 mm) hat channels is
recommended for the Firestone UC-500
500 metal flush panel.
Firestone UC-500 panels must be installed in a sequential order.
Application of a Firestone approved underlayment prior to panel installation is recommended.
Storage:
•
•
Firestone metal panels should be stored in a well ventilated, dry place where no moisture can contact them. Moisture (F
(From rain,
snow, condensation, etc.) trapped between layers of material may cause water stains or white rust, which can affect the service
life of the material and will detract for the appearance.
If outdoor storage cannot be avoided, protect the panels with a ventilated canvas or waterproof paper co
cover.
ver. Do not use plastic,
which can cause condensation. Keep the material off the ground in an inclined position with an insulator such as wood.
Protective film may degrade or become brittle with long term exposure to direct sunlight.
Precautions:
•
•
Aluminum is recommended for soffit applications.
Oil canning is not a cause for rejection. Heavier gauges, narrower widths, striations, and embossing minimize oil canning.
•
Sealant for end laps and lap joints shall be non--drying, non-toxic, and non-shrinking
ing with a serviceable temperature of –60 to
212 ºF (-51 to 100 ºC).
life butyl sealants work best as a gasket sandwiched between two pieces of metal. Non
Non-acetic
acetic cured silicone color
Quality, long-life
matching sealants are recommended when voids must be fill
filled.
ed. Sealants are not a substitute for proper assembly and
workmanship.
Exercise caution when lifting, moving, transporting, storing or handling Firestone metal to avoid possible physical damage.
Refer to Material Safety Data Sheets (MSDS) for safety inform
information.
Immediately remove protective film after installation.
•
•
•
•
Manufacturing Location:
•
•
•
•
Anoka, MN
College Park, GA
Las Vegas, NV
Warren, MI
Product Data:
Tapered Panels:
Radiused Panels:
Stiffening Ribs:
Venting:
Net Free Area:
Standard Panel Surface:
Optional Panel Surface:
No
No
Optional
Optional as UC-500V
2.75 in² per LF on 12” wide UC
UC-500V panels
Smooth
Stucco Embossed*
Firestone Building Products • 250 W. 96th Street, Indianapolis, IN 46260 • Sales: (800) 428-4442 • Technical (800) 428-4511 • www.firestonebpco.com
S723-RFS-270
9.24.2013
TECHNICAL INFORMATION SHEET
Product Size:
Panel Width:
Optimal Panel Width:
Panel Depth:
Minimum Panel Length:
Maximum Panel Length:
8” (203.2 mm), 12” (304.8 mm), 16” (406.4 mm) & 20” (508.0 mm)
8” (203.2 mm), 12” (304.8 mm) & 20” (508.0 mm)
1” (25.4 mm)
36” (914.4 mm)
576” (14,630.4 mm)
Technical Information:
Air Infiltration:
Structural Performance:
Water Penetration:
Fire Rating:
Hail Impact Rating:
Florida Building Code:
Note:
ASTM E 283
ASTM E 330
ASTM E 331
UL Class A Rated Assemblies, UL 263 and UL 790
Class 4, UL 2218
Approved
* Not Manufactured at all Facilities.
Testing is not applicable for all combinations of substrates, materials, and dimensions. All construction assemblies must be
installed in accordance with the tested assembly. Please refer to the Metal Code Approval Guide on the Firestone website for
tested assemblies and code listings.
Please contact your Roof System Advisor for special considerations on panels over 180” (4572 mm).
12.0"
2.0"
3.1"
3.1"
2.0"
0.9"
Material and Thickness:
Metal Specification:
Available Finishes:
Aluminum
0.032” (0.81 mm)
0.040” (1.02 mm)
Base Metal: Aluminum
Minimum Yield: 21 KSI (145 MPa)
-6
-6
Thermal Expansion: 12.6 x 10 in/in/F° (22.2 m/m.K x 10 )
3
Mod. Of Elasticity: 10.0 x 10 x KSI (68.9 MPa)
Base Metal: AISA-G90 Galvanized steel
Minimum Yield: 33 to 45 KSI (227 to 310 MPa)
-6
-6
Thermal Expansion: 06.7 x 10 in/in/F° (13.9 m/m.K x 10 )
6
Mod. Of Elasticity: 29.0 x 10 x KSI (200 GPa)
Base Metal: AZ-55 Hot Dipped Galvalume
Minimum Yield: 50 KSI (345 MPa)
-6
-6
Thermal Expansion: 06.7 x 10 in/in/F° (13.9 m/m.K x 10 )
6
Mod. Of Elasticity: 29.0 x 10 x KSI (200 GPa)
AGSC minimum copper content of 99.9% copper, silver
counting as copper, cold rolled from ingots of 122 alloy.
-6
-6
Thermal Expansion: 9.3 x 10 in/in/F° (16.5 m/m.K x 10 )
AGSC copper meets and/ or exceeds ASTM B370 specification.
RHEINZINK®: Electrolytic high-grade, 99.995% pure, fine zinc
(DIN EN 1179) titanium copper alloy. certified according to DIN
ISO 9001: 1994
-6
Thermal Expansion: 2.2 mm/m x 100K (16.5” x 10 in/in/F)
Anodized
Kynar 500®/Hylar 5000®
Unpainted/Mill Finish
Galvanized Steel
26 ga. (0.48 mm)
24 ga. (0.64 mm)
22 ga. (0.79 mm)
Galvalume® Steel
26 ga. (0.48 mm)
24 ga. (0.64 mm)
22 ga. (0.79 mm)
Copper
16 oz (0.56 mm)
20 oz (0.69 mm)
Zinc
0.028” (0.7 mm)
0.032” (0.8 mm)
0.040” (1.0 mm)
Kynar 500®/Hylar 5000®
Unpainted G90
Acrylume® – Clear Acrylic Coated
Natural
Shiny
Preweathered Blue-Gray
Preweathered Graphite Gray
Note:
For standard color selection, consult the current UNA-CLAD Color Selection Guide. Custom color services are available upon
request. Consult the current base metal Sheet & Coil T.I.S. for additional information on the base metal and coating. Not all
materials and thicknesses are available from all locations.
Please Contact your Firestone Roof System Advisor at 1-800-428-4511 for further information.
This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which
meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any
responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to
installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer.
Firestone Building Products • 250 W. 96th Street, Indianapolis, IN 46260 • Sales: (800) 428-4442 • Technical (800) 428-4511 • www.firestonebpco.com
S723-RFS-270
9.24.2013
Download