ASSEMBLY AND INSTALLATION INSTRUCTIONS 450 Lumens WARNING: When using this lighting device, safety precautions should be followed at all times. READ THE INSTRUCTIONS BELOW CAREFULLY AND FOLLOW THEM FOR YOUR OWN SAFETY! 1. This device is designed for indoor use. Do not use outdoors. 2. Prior to installation, battery connector must be open to prevent high voltage from being present on out put leads (red & yellow). 3. This device is designed for use with 17W–40W single pin or bipin fluorescent lamps. Please use energy-saving, circline, U-shaped, or 4-pin rapid start long compact fluorescent lamps. 4. Please ensure the electricity connections conforms to the National Electrical Code and local regulations if applicable. 5. To avoid electric shock, please disconnect normal and emergency power supplies, and battery connector of the emergency ballast before servicing. 6. This device is designed for factory or field installation in either the ballast channel, or on top of the indoor fixture, except air handling heated air outlets, wet or hazardous location fixtures. Do not install this device near gas or electric heaters. 7. AC power source of 120 VAC or 277 VAC is required. 8. The battery is sealed, non-maintenance, and is not replaceable in the field. Please contact manufacturer for information on service. Do not attempt to service the battery please. 9. Do not use accessory equipment that is not recommended by manufacturer. Failure to do so may cause unsafe conditions. Servicing should only be performed by qualified service personnel. 10. Do not use the product for other purpose that the product is NOT designed for. PLEASE SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS DIAGRAM DIAGRAM121 NOTE: All the branch circuit wiring has to be ready as well as an unswitched source of power before the fixture is installed. Confirm the same branch circuit would be used for both the emergency ballast and the AC ballast. CAUTION: Battery connector has to be opened for preventing high voltage on output leads (red and yellow). Wait until the installation process has been completed and AC is supplying power to the emergency ballast, and then join the battery connector. Emergency Ballast 1. AC power has to be off before installation. Battery Pack Channel Cover 2. Choose the right wiring diagram to connect the ballast to the AC ballast and lamp. Charging Indicator Light Test Switch 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations. 4. Follow diagrams 1 and 2 to install the battery pack on the top of the fixture or in the ballast channel. DIAGRAM 2 Emergency Ballast 5. To install the test switch, it would go through the side of a strip fixture or the ballast channel cover of a troffer. Follow diagrams 1 and 2 to drill a 1/2” hole and install the test switch. In order to remove AC power from both the emergency ballast and the AC ballast, the test switch has to be connected properly (see diagram 4). 6. Match violet and brown leads to connect the charging indicator light to the battery pack (see diagram 5). The charging indicator will be on after the fixture is installed properly. Charging Indicator Light Test Switch 7. Please search for a readily visible location to apply the CAUTION label which reads, “This unit has more than one power supply connection point. To reduce the risk of electric shock, disonnect both the branch circuit-breakers or fuses, and emergency power supply before servicing.” 8. Do not join the inverter connector until the fixture is completely installed and supply AC power to the emergency ballast. 9. The battery needs to be charged for one hour in order to have short-term testing on the emergency function. Before having a long-term emergency function testing, the battery in the emergency ballast has to be charged for 24 hours. DIAGRAM 4 SINGLE POLE UNSWITCHED FIXTURE SWITCHED FIXTURE EMERGENCY BALLAST EMERGENCY BALLAST EMERGENCY BALLAST EMERGENCY BALLAST DIAGRAM 3 DIAGRAM 5 TROFFER-STYLE FIXTURE OPTIONAL STRIP-STYLE FIXTURE Emergency Ballast Fixture Fixture Fixture Ballast Channel Cover Leads to Charging Indicator Light Indicator Light 7/8” Punch Indicator Light Violet (+) Violet (+) Brown (-) Brown (-) 7/8” Bushing Inserted into Ballast Channel Cover AC ON TEST Plastic Tubing (please cut to necessary length) 1/2” White Bushing to Hold Charging Indicator Light Fixture Lens Step 1 Step 2 Charging Indicator Light Operation • The charging indicator light would be on to indicate the battery is being charged when AC power is applied. • This emergency ballast would function and operate one or two lamps at least 90 minutes when the AC power is failed. Maintenance Note: Services should only performed by qualified personnel. The emergency ballast should be checked periodically to confirm proper functioning and the following schedule is recommended: 1. To inspect the charging indicator every month and confirm that is illuminated. 2. Push the test switch for 30 seconds to ensure the emergency ballast is functioning. Recommended to perform this testing every 30 days. 3. Perform a long-term test (90-minute battery discharge) at least once every year. One lamp should operate for no less than 90 minutes. WIRING DIAGRAMS FOR 1-LAMP EMERGENCY OPERATION EMERGENCY BALLAST AND AC BALLAST MUST BE FED FROM THE SAME BRANCH CIRCUIT TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLASTS. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS. For 2-Lamp Fixtures For 1-Lamp Fixtures A. RAPID START AC BALLAST BLACK LINE WHITE BLUE BLUE 1-LAMP RAPID START BALLAST A. RAPID START AC BALLAST BLUE BLU/WHT YELL/GRN RED YELLOW RED VIOLET EMERGENCY BALLAST + _ BROWN ORANGE BLACK WHITE BLUE OR RED BLACK WHITE 1-LAMP INSTANT START BALLAST YELLOW YELLOW 2-LAMP RAPID START BALLAST + VIOLET _ BROWN ORANGE BLACK WHITE EMERGENCY BALLAST YELLOW BLUE BLU/WHT YELL/GRN RED YELLOW RED VIOLET _ 277V 120V COM RED WHITE RED BATTERY CONNECTOR B. LEAD/LAG INSTANT START SLIMLINE BALLAST BLUE BLUE BLACK LINE WHITE 2-LAMP LEAD/LAG BALLAST WHITE BLU/WHT YELL/GRN RED YELLOW VIOLET RED + BROWN LAMP 1 BATTERY CONNECTOR INDICATOR LIGHT EMERGENCY BALLAST + INDICATOR LIGHT LAMP 2 277V 120V COM RED ORANGE BLACK WHITE LAMP 1 BATTERY CONNECTOR BLUE BLUE BLUE BROWN RED BLU/WHT YELL/GRN LAMP WHITE RED B. INSTANT START SLIMLINE BALLAST LINE BLACK LINE WHITE INDICATOR LIGHT LAMP 277V 120V COM _ EMERGENCY BALLAST ORANGE BLACK WHITE RED WHITE RED BATTERY CONNECTOR INDICATOR LIGHT LAMP 2 277V 120V COM C. CIRCLINE RAPID START BALLAST BLUE RED BLACK LINE WHITE ORANGE BLACK WHITE BLU/WHT YELL/GRN YELLOW RED BLUE 1-LAMP CIRCLINE BALLAST EMERGENCY VIOLET + BALLAST _ BROWN C. SERVES SEQUENCE INSTANT START BALLAST BLACK RED WHITE WHITE RED INDICATOR LIGHT LAMP 277V 120V COM LINE BLUE BLUE WHITE BLU /WH T YELL/GR N AC BALLAST RED EMERGENCY BALLAST YELLOW RED RED 120V COM BLACK LINE WHITE WHITE INDICATOR LIGHT 2-LAMP LEAD/LAG BALLAST WHITE 3-LAMP RAPID START ELECTRONIC BALLAST ORANGE BLACK WHITE BLU/WHT YELL/GRN EMERGENCY BALLAST YELLOW VIOLET + BROWN LAMP 1 BLUE BLUE BLU/WHT YELL/GRN RED YELLOW VIOLET + _ BROWN EMERGENCY BALLAST ORANGE BLACK WHITE RED 277V 120V COM WHITE RED BATTERY CONNECTOR INDICATOR LIGHT 277V 120V COM LINE BLACK WHITE BLUE WHITE RED RED RED 2-LAMP CIRCLINE BALLAST RED BLUE RED BLU/WHT YELL/GRN YELLOW BLUE WHITE VIOLET _ ORANGE BLACK WHITE + BROWN WHITE _ EMERGENCY BALLAST 277V 120V COM RED WHITE RED RED LAMP 1 BATTERY CONNECTOR INDICATOR LIGHT LAMP 2 RED E. CIRCLINE RAPID START BALLAST BLUE BLUE/WHT BLUE/WHT YELLOW YELLOW RED RED WHITE BATTERY CONNECTOR BLUE LAMP 1 A. RAPID START BLACK 277V 120V COM D. INSTANT START ELECTRONIC BALLAST 277V For 3-Lamp Fixtures LINE _ RED INDICATOR LIGHT LAMP 2 LAMP 2 BLUE BLUE + BROWN EMERGENCY BALLAST ORANGE BLACK WHITE TO UNSWITCHED AC USE PROPER TAP CAP UNUSED LEAD ORANGE BLAC K WHI TE BATTERY CONNECTOR LAMP (EMERGENCY) YELLOW RED LAMP 1 LINE BLACK BLU/WHT YELL/GRN VIOLET BATTERY CONNECTOR D. 1-LAMP INSTANT START BALLAST BLUE BLUE 2-LAMP SERIES SEQUENCE BALLAST INDICATOR LIGHT LAMP 2 BATTERY CONNECTOR LAMP 3 For 4-Lamp Fixtures B. INSTANT START BALLAST LINE BLUE BLACK WHITE AC BALLAST BLUE BLUE RED LAMP 1 LAMP 2 BLUE BLUE/WHITE YELLOW/GREEN YELLOW VIOLET+ _ BRO WN EMERGENCY BALLAST ORANGE BLAC K WHI TE RED 277V 120V COM TO UNSWITCHED AC CAP UNUSED LEAD A. INSTANT START BALLAST LINE YELLOW RED BLUE BLACK WHITE WHITE YELLOW AC BALLAST BAT TERY CONNECTOR CHARGING INDICATOR LIGHT BLUE RED RED EMERGENCY VIOLET + _ BALLAST BROWN ORANGE BLACK WHITE RED LAM P 2 277 V 120 V COM TO UNSWITCHED AC CAP UNUSED LEAD WH ITE RED BATTERY CONNECTOR CHARGING INDICATOR LIGHT LAM P 1 LAMP 3(EMERGENCY) BLUE BLUE/WHITE YELLOW /GREEN YELLOW LAM P 3 LAM P 4(EMERGENCY) EMERGENCY ONLY ONE (1) LAMP WITHOUT AC BALLAST CAP CAP BLUE BLU/WHT YELL/GRN YELLOW LAMP VIOLET + BROWN INDICATOR LIGHT _ EMERGENCY BALLAST B. RAPID START BALLAST LIN E ORANGE BLACK WHITE 277V 120V COM RED WHITE RED BATTERY CONNECTOR RED RED BLACK WHITE YELLOW YELLOW BROWN BROWN AC BALLAST BLUE/WHITE BLUE/WHITE BLUE BLUE LAM P 1 LAM P 2 BLUE BLUE/WHITE YELLOW/GREEN EMERGENCY VIOLET + _ BALLAST BROW N YELLOW CHARGING INDICATOR LIGHT LAM P 3 LAM P 4 ( EMERGENCY) NOTE: Use the proper tap cap to unswitched AC lead. ORANGE BLACK WHITE RED 277 V 120 V CO M WHITE RED BATTERY CONNECTOR TO UNSWITCHED AC CAP UNUSED LEAD