Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Please read this guide before installing. Contents Listing Page Ratings and model number overview............................1 Mounting the Interface.................................................2 Wiring Overview for LUT-ELI-3PH units on: RadioTouch Systems...............................................2 Panel-Based Systems..............................................4 EcoSystem or Quantum bus supplies.......................8 GRAFIK Eye QS units...............................................9 Energi Savr Node units..........................................10 Emergency Power Mode Setup: LCP Panels..............11 NEC Class 2/PELV Wiring to Fire Alarm Control Panel (FACP).............................................12 Troubleshooting RadioTouch............................................................13 Panel Based Systems............................................14 Energi Savr Node Installations................................15 EcoSystem or Quantum System............................16 Grafik Eye QS Installation.......................................17 The Emergency Lighting Interface – LUT-ELI-3PH is UL924 Listed as “Emergency Lighting and Power Equipment”. The interface shall be used with: Lutron GRAFIK Eye GP, XP, and LP panels; LCP128 panels; Softswitch128 panels; EcoSystem; Quantum; GRAFIK Eye QS, RadioTouch controllers, and Energi Savr Node units. Description The LUT-ELI-3PH unit senses the line voltage on all three phases or a single phase and controls the emergency signal to the following compatible Lutron products/systems: • Circuit Selector for GP, LP, XP panels • LCP/XPS controller for LCP128, and Softswitch 128 panels • EcoSystem Bus Supply • Quantum Bus Supply • Grafik Eye QS unit • RadioTouch controller • Energi Savr Node unit When one or more phases of normal power are lost, the LUT-ELI-3PH unit sends a signal to the affected device(s), activating the emergency mode. Any lights controlled by these devices will go to the emergency light level setting (factory set to 100% intensity). When normal power is restored, the lights will return to their previous intensities. 9 6 5 4 3 LED1 LED2 TEST LED3 1 FACF RADIOTOUCH 2 GND PHASE NOT USED CONTACTS ´FACP´ N/O 7 ´FACP´ N/C 8 CONTACTS 10 COMMON MUX 11 +24VFW DRAIN 12 MUX SENSE Important Safeguards S1 CLASS 2 LOW VOLTAGE WIRING System Ratings • Voltage: 100-347 V 50/60 Hz 30 mA • Current: 20 A maximum circuit breaker For use with Lutron®: GRAFIK Eye® GP, LP, and XP panels; LCP128TM panels; Softswitch128 panels; EcoSystem® lighting control system; Energi Savr NodeTM units; Quantum® systems; GRAFIK Eye QS units, and RadioTouch® lighting controllers. Note: This device does not provide emergency power. An Emergency (Essential) power source must be provided. LUT-ELI-3PH Installation Guide • Follow all national and local electrical codes and safety standards. • Turn off power before installation. • Line voltage input to the LUT-ELI-3PH unit must be from the NORMAL (non-essential) power source. • Read and follow all safety instructions. • For indoor use only. • Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. • Do not use this equipment for other than intended use. • All servicing should be performed by qualified service personnel. System Limits (per / LUT-ELI-3PH) • • • • • • 32 circuit selectors 100 RadioTouch Controllers 32 EcoSystem bus supplies 32 Quantum bus supplies 32 Energi Savr Node units 32 LCP/XPS Controllers Lutron® | 1 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide 1. Turn power off. 2. Wire the line voltage leads that protrude from back of LUT-ELI-3PH unit into the junction box. 3. Mount the LUT-ELI-3PH unit onto a 4 x 4-inch (102 x 102 mm) junction box (not included, but available; Lutron part number 241-496). 4. Be sure all the power wires are completely inside the junction box before tightening the mounting screws. 5. Remove front enclosure cover to expose the terminal blocks, test switch, and status LEDs. 6. Insert the NEC® Class 2/PELV wires through knockouts in the LUT-ELI-3PH enclosure as shown in the diagram. 7. Connect the NEC Class 2/PELV wires to the Lutron® product or system, which the LUT-ELI-3PH will be controlling. Specific wiring to these devices will be described in the following sections. 8. Reinstall front enclosure cover. Note: Call the Lutron Technical Support Center at (800) 523-9466 for restrictions and wiring requirements for emergency fixtures (fixtures that never turn off or have a battery backup ballast in the fixture). Side View (Cross-Section) Mounting the Interface 4 x 4 in (102 x 102 mm) Junction Box LUT-ELI-3PH UNIT WALL Insert NEC Class 2/PELV wires through knockouts Installing a LUT-ELI-3PH Unit in a RadioTouch® System Line Voltage Connections WARNING! Danger of shock. May result in serious injury or death. DO NOT WIRE WHEN LIVE! Switch off power to all power feeds via circuit breaker or isolator before wiring or servicing the LUT-ELI-3PH unit and RadioTouch System Buttons and LEDs in the unit are used for troubleshooting. If wiring is exposed when accessing buttons and LEDs, the unit must be accessed by a certified electrician, following local codes. Three-Phase Wiring Red Red Red White Green Normal Power Normal Power Figure #1 Figure #2 Lutron® | 2 Normal Lights Ground Neutral Phase C Phase B Phase A Normal Lights Ground Neutral Hot Red Red Red White Green Single-Phase Wiring Note: Provide proper short-circuit and overcurrent protection at the distribution panel. Maximum circuit breaker rating of 20 A. LUT-ELI-3PH Installation Guide Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Installing a LUT-ELI-3PH Unit in a RadioTouch® System (continued) Test the System Please perform the following tests to ensure proper installation. 1. Turn off one of the Normal (Non-Essential) phase(s) breaker(s) that the LUT-ELI-3PH unit is monitoring. You should see the following: •All lights controlled by Emergency (Essential) panel will go to FULL INTENSITY (factory set). •PHASE ON/OFF status Indicator (green) will turn OFF as the above test creates a phase failure. •Upon turning the breaker back on, all lights should return to their previous intensity. 2. Press and hold switch SW1 on the LUT-ELI-3PH unit. You should see the following: •TEST LED (orange) will turn ON. •All lights controlled by Emergency RadioTouch controller will go to FULL INTENSITY (factory set). Note: PHASE ON/OFF status indicator (green) will not turn OFF as test #2 does not create a phase failure. •Upon releasing switch SW1, all lights will return to their previous intensities. NEC® Class 2/PELV Connections Note: When wiring for a backup/emergency source of power, the RadioTouch Controller (models RTA-RX-F, RTA-RX-F-SC, RTA-RXSW), being used for the backup/ emergency lights (Unit A and B) cannot be controlled by an occupancy sensor. Units A and B DIP switch 2 must be in the down position. NEC Class 2/PELV Wiring to RadioTouch Controllers One LUT-ELI-3PH can be connected in parallel with up to 100 RadioTouch Controllers. 1. Flip DIP switch 2 on the RadioTouch Controller to the down position. 2. Disconnect any occupancy sensors wired to the RadioTouch Controller. 3. Make the following connections. From LUT-ELI-3PH Unit Terminal 8 (+V Input) Terminal 7 (Circuit Common) Terminal 1 (Signal) To RadioTouch Controller Terminal 4 (24 V ), Unit A only Terminal 6 (Cir Com) Terminal 2 (Occ Sig) Note: Only one RadioTouch unit can have its 24 V (number 4) terminal connected to terminal 8 (+V Input) on the LUT-ELI unit regardless of the number of wired RadioTouch units. Available power from this unit for daylight sensors must be derated to 15 mA. ® 10 9 8 7 6 5 4 2 1 LED2 LED1 LED3 1 2 3 4 5 RTA-R X-F-SC TEST FACF RADIOTOUCH NOTUSED 3 PHASE CONTACTS ´FACP´N/O CONTACTS ´FACP´N/C COMMON +24VFW MUX MUX SENSE DRAIN 11 S1 (8) (7) Green/V er de/VStatus ert Power 3 4 Flip Dip Switch 2 to the down position DimmedHot/AtenuadorVivo/CourantTamisé* SwitchedHot/InterruptorVivo/CourantCommuté Blue/Bleu/Azul er de/V ertStatus Program Power 1 2 3 4 5Green/V RTA-R X-F-SC Hot/Vivo/Chargé Red&Black/Rojo&Negro/Rouge&Noir Red/Rojo/RougeOR 277V 13 14 1 2 Ground/Tierra/Terre 3 White/Blanco/Blanc 15 16 Hot is for use only with Lutron Hi-Lume FDB-series or Eco-10 ECO-series dimming ballasts. * Dimmed V ivo es para ser utilizado únicamente con las series de balastos *deEl Atenuador atenuaci ón Hi-Lume FDB o Eco-10 ECO de Lutron. T amisé doit être utilisé seulement avec le Hi-Lume FDB-series ou avec * Courant le ballast de gradation Eco-10 ECO-series de Lutron. * For 120 V~ use black wire, cap red. For 277 V~ use red wire, cap black. P/N 500-10634 (2) (4) (6) CCO5 0-10 V PowerWiringCableadodePoderCâblaged'alimentation Black/Negro/Noir 120V 6 7 8 9 10 11 12 DistributionPanel CLASS 2 LOW VOLTAGE WIRING 9 10 11 12 13 14 15 16 8 CCO4 6 7 CCO3 5 Orange/Anaranjado/Orange* Burn-In (2) Signal (6) Circuit Common LUT-ELI-3PH Installation Guide 4 ® 1 PaneldeDistribución PanneaudeDistribution (1) 3 CCOCom 1 2 Neutral/Neutro/Neutre 5 100Hr/100% 5 CCO2 4 CCO1 3 + CCO5 1 2 3Ground/Tierra/Terre Program White/Blanco/Blanc 2 2 DimmedHot/AtenuadorVivo/CourantTamisé* Red&Black/Rojo&Negro/Rouge&Noir 1 1 SwitchedHot/InterruptorVivo/CourantCommuté Red/Rojo/RougeOR 277V CLASS2LOWVOLTAGEWIRING CCO4 PowerWiringCableadodePoderCâblaged'alimentation Blue/Bleu/Azul 12 CCO3 0-10 V Orange/Anaranjado/Orange* GND 9 10 11 12 13 14 15 16 8 CCOCom 6 7 CCO2 5 CCO1 4 + 3 15V OccSig PELV(Class2:USA) Flip Dip Switch 2 to the down position Occ.Com 1 2 PROG STAT ON _ 5 _ 4 PSSig 3 24V 2 CirCom 1 CONFIGURACIONES REGLAGES PWR SETTINGS 100Hr/100% ® RefertotheInstallersGuideformore detailedinstructions. ConsultelaGuíadeInstaladorespara informaciónmásdetallada. RéférerauGuided’installationpourplusde renseignementsdétaillés. 1-800-523-9466 1-888-235-2910 PSSig PROG STAT ON LISTED243C Ind.Cont.Eq. Coopersburg,PA18036USA USA,Canada Mexico www .lutron.com 15V CONFIGURACIONES REGLAGES PWR SETTINGS 120/277V60Hz 16AMax. TM 24V RefertotheInstallersGuideformore detailedinstructions. ConsultelaGuíadeInstaladorespara informaciónmásdetallada. RéférerauGuided’installationpourplusde renseignementsdétaillés. 1-800-523-9466 1-888-235-2910 RadioTouch RTA-RX-F-SC CirCom Coopersburg,PA18036USA USA,Canada Mexico www .lutron.com ® OccSig LISTED243C Ind.Cont.Eq. Occ.Com 120/277V60Hz 16AMax. TM PELV(Class2:USA) RadioTouch RTA-RX-F-SC RadioTouch Unit B 120/277 V feed backup/ Emergency power P/N500-10634 ©2006LutronElectronicsCo.,Inc. RadioTouch Unit A 120/277 V feed backup/ Emergency power P/N500-10634 ©2006LutronElectronicsCo.,Inc. LUT-ELI-3PH Unit Additional RadioTouch Controller for Backup/ Emergency Light(s) 2 3 4 Burn-In Neutral/Neutro/Neutre Hot/Vivo/Chargé Black/Negro/Noir 120V 5 6 7 8 9 10 11 12 CLASS 2 LOWDistributionPanel VOLTAGE WIRING 13 14 15 16 PaneldeDistribución PanneaudeDistribution Hot is for use only with Lutron Hi-Lume FDB-series or Eco-10 ECO-series dimming ballasts. * Dimmed V ivo es para ser utilizado únicamente con las series de balastos *deEl Atenuador atenuaci ón Hi-Lume FDB o Eco-10 ECO de Lutron. T amisé doit être utilisé seulement avec le Hi-Lume FDB-series ou avec * Courant le ballast de gradation Eco-10 ECO-series de Lutron. * For 120 V~ use black wire, cap red. For 277 V~ use red wire, cap black. P/N 500-10634 (2) (6) To additional RadioTouch controllers (100 maximum) Lutron® | 3 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Installing a LUT-ELI-3PH Unit in a Panel-Based System Line Voltage Connections Note: Provide proper short-circuit and overcurrent protection at the distribution panel. Maximum circuit breaker rating of 20 A. WARNING! Danger of shock. May result in serious injury or death. DO NOT WIRE WHEN LIVE! Switch off power to all power feeds via circuit breaker or isolator before wiring or servicing the LUT-ELI-3PH unit and Panel-Based System. Buttons and LEDs in the unit are used for troubleshooting. If wiring is exposed when accessing buttons and LEDs, the unit must be accessed by a certified electrician, following local codes. GP3 panel shown Wiring from Normal (Non-Essential) GP Panel Typical load circuit 5 4 3 LED2 LED1 LED3 1 S1 TEST RADIOTOUCH 6 CLASS2LOWVOLTAGEWIRING FACF NOTUSED 2 GND PHASE CONTACTS 7 ´FACP´N/O 8 CONTACTS 9 ´FACP´N/C 10 COMMON MUX 11 +24VFW DRAIN 12 MUX SENSE DH1 SH1 H1 DH2 SH2 H2 DH3 SH3 H3 Control wiring to circuit selector N Red Red Red White Branch circuit breakers Green (to ground lug) Terminal blocks Neutral block Normal power feed wiring Ground lug Wiring from Mains with GP, LP, XP, and XPS/LCP Panels Lutron® | 4 Red Red Red White Green Normal Power Normal to panel Ground Neutral Phase C Phase B Phase A LUT-ELI-3PH Installation Guide Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Installing a LUT-ELI-3PH Unit in a Panel-Based System (continued) NEC® Class 2/PELV: USA Connections • • • • Notes Pull NEC Class 2/PELV wiring for system communications. NEC Class 2/PELV wiring must be daisy-chained. NEC Class 2/PELV wiring must be run separately from line (mains) voltage. A LUT-ELI-3PH unit can be placed anywhere on the power panel link. • • Wiring Notes NEC Class 2/PELV wiring link is 500 to 2000 feet (152 to 610 m), use Lutron® cable GRX-CBL-46L: - Two 12 AWG (2.5 mm2) for control wiring (+V and com) - One twisted, shielded pair 22 AWG (0.5 mm2) for data link - One 18 AWG (1.0 mm2) for sense line between panels. Lutron has also approved smaller-gauge cable from Belden®, Liberty Wire & Cable®, AlphaWire Company, and Signature Wire Corp. Ask for Lutron GRAFIK Eye® Cable. Processor panel Dimming panel LUT-ELI-3PH Unit Power panel link Wallstation links Panel to panel wiring See above for wiring notes LUT-ELI-3PH Installation Guide Lutron® | 5 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Installing a LUT-ELI-3PH Unit in a Panel-Based System (continued) Emergency Power: The additional 18 AWG (1.0 mm2) wire is a “sense” line from terminal 12 on the LUT-ELI-3PH. This sense line allows an Emergency (Essential) lighting panel to “sense” when Normal (Non-Essential) power is lost. If more than one emergency lighting panel needs to sense Normal (Non-Essential) from a specific LUT-ELI-3PH unit, you may have to run a dedicated wire between each LUT-ELI-3PH unit and Emergency (Essential) panel(s). Shield/Drain: Connect shielding as shown below in wiring example A: - Do not connect to Ground (Earth) or circuit selector. - Connect the bare drain wires and cut off the outside shield. • Connections Wiring Example A Control Wiring: (2) 12 AWG (2.5 mm2) 1: Common 2: 24 V 1 Data Link: (1) shielded, twisted pair 18 AWG (1.0 mm2) 3: MUX 4: MUX Shield/ Drain Each NEC Class 2/PELV terminal can accept only two 18 AWG (1.0 mm2) wires. Two 12 AWG (2.5 mm2) conductors won't fit. Connect as shown below in wiring example B. LUT-ELI-3PH Circuit Selector Terminal 12 (Sense) Terminal 5 (Sense) Terminal 11 (Drain) Terminal D (Drain) Terminal 10 (MUX) Terminal 4 (MUX) Terminal 9 (MUX) Terminal 3 (MUX) Terminal 8 (+V Input) Terminal 2 (+24VFW) Terminal 7 (Circuit Common) Terminal 1 (Common) Sense: (1) 18 AWG (1.0 mm2) 5: Sense line 1 2 3,4 3 ,4 5 1 2 3 4 D 5 4 3 LED2 LED1 1 TEST 2 LED3 RADIOTOUCH 5 FACF NOTUSED 6 PHASE CONTACTS 7 ´FACP´N/O 8 CONTACTS 9 ´FACP´N/C 10 COMMON MUX 11 +24VFW DRAIN 12 MUX SENSE 1 2 3 4 D 5 S ELECT CIRCUIT C 1 2 3 4 D 5 D S ELECT CIRCUIT Power Link AB 1 S1 CLASS2LOWVOLTAGEWIRING C D 1 2 2 Circuit Circuit Panel 1 Wiring Example B Link DataBOK MUX Sense MUX Drain +24VFW MUX Common AB MUX Link DataAOK Drain Link DataBOK MUX Power Common Sense MUX Drain +24VFW MUX Common DataAOK Common 1 2 3 4 D 5 GND To lighting controls or processors 2 MUX • NEC® Class 2/PELV Panel to Panel Wiring Notes Drain • Panel 2 (4) 12 AWG (2.5 mm2) 1 2 3 4 D 5 Data B OK LUT-ELI-3PH Installation Guide n Power OK m n se mon Data A OK FW Lutron® | 6 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Test the System Please perform the following tests to ensure proper installation. 1. Turn off one of the Normal (Non-Essential) phase(s) breaker(s) that the LUT-ELI-3PH unit is monitoring. You should see the following: •PHASE ON/OFF status Indicator (green) will turn OFF as the above test creates a phase failure. •Circuit selector on Emergency (Essential) panel will go to ‘ord’ override mode. •All lights controlled by Emergency (Essential) panel will go to Full Intensity (Factory Set). •The circuit selector in Emergency (Essential) panel will read ‘ord’ on the value display when in Emergency mode. •All lights controlled by Normal (Non-Essential) panel will freeze at their respective intensities. 2. Press and hold switch SW1 on the LUT-ELI-3PH unit. You should see the following: • TEST LED (orange) will turn ON. Note: PHASE ON/OFF status indicator (green) will not turn OFF as test #2 does not create a phase failure. • Circuit Selector on Emergency (Essential) Panel will go to ‘ord’ override mode. • All lights controlled by Emergency (Essential) panel will go to FULL INTENSITY (factory set). • The circuit selector on Emergency (Essential) panel will read ‘ord’ on the value display when in Emergency Mode. • All lights controlled by Normal (Non-essential) panel will freeze at their current intensities. • Upon releasing switch SW1, all lights will return to their original intensities. SELECT CIRCUIT D SELECT CIRCUIT 1 1 2 2 Circuit Circuit VIEW VALUE SELECT VALUE VIEW VALUE SELECT VALUE Link A 3 Link A Link B 4 Link B 3 4 Value Value SELECT VALUE DISPLAYED Circuit Level Load Type (See Instructions) SELECT VALUE DISPLAYED Circuit Level Load Type (See Instructions) 5 5 Zone Assignment w/ Circuit Schedule Zone Assignment w/ Zone CaptureTM Zone Assignment w/ Circuit Schedule Zone Assignment w/ Zone CaptureTM Low-End Trim High-End Trim Low-End Trim High-End Trim Address ('Ad' displayed) Address ('Ad' displayed) Warning - Read instructions to set the Load Type. Instructions show more load types. Warning - Read instructions to set the Load Type. Instructions show more load types. Load Type Quick Reference: Load Type Quick Reference: --- Unassigned 3-1 Neon / CC --- Unassigned 3-1 Neon / CC 1-1 Incandescent 4-1 Non-Dim 1-1 Incandescent 4-1 Non-Dim 2-1 Fluorescent Lutron Hi-lume FDB Ballast 2-2 Fluorescent Lutron Tu-WireTM Ballast R LINK 1 Drain MUX Comm Link Link AB C MUX Drain Sense MUX 24VFW 1 2 3 4 D 5 MUX D MUX Link Link AB C DataBOK PowerOK Common 1 2 3 4 D 5 DataAOK DataBOK PowerOK Drain DataAOK LUT-ELI-3PH Installation Guide Circuit Selector in Emergency (Essential) Panel 1 2 3 4 D 5 Comm All Emergency Panels • Move SW6 to the right Emergency (Essential) position. In this arrangement, the LUT-ELI-3PH unit will be the only unit controlling the sense line. If one or more phases go down, the LUT-ELI-3PH unit sends a signal through the sense line to Emergency (Essential) panel(s). The lights controlled by these panels will go to ‘ord’ override levels (factory set to full intensity). When normal power is restored, lights will return to their previous intensities. Note: When in ‘ord’ override mode (factory set to full intensity), ‘ord’ will appear on value display to confirm that Emergency (Essential) position is in effect. 1 2 3 4 D 5 MUX Panels are shipped with SW6 (located at the base of each Circuit Selector) in the middle position. Terminal 5 (sense) has no affect on the circuit selector operation. Drain Sense Circuit Selector in Normal (Non-Emergency) Panel MUX Setting the Circuit Selector Normal/Emergency Switch (SW6) Position 24VFW MUX Installing a LUT-ELI-3PH Unit in a Panel-Based System (continued) Common LINK 2 (Non-Ess) Normal (Essential) Emergency Switch is in center position 2-1 Fluorescent Lutron Hi-lume FDB Ballast 2-2 Fluorescent Lutron Tu-WireTM Ballast R LINK 1 LINK 2 (Non-Ess) Normal (Essential) Emergency Switch is moved to the right (emergency) position Lutron® | 7 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Installing a LUT-ELI-3PH Unit in an EcoSystem® or Quantum® System Line Voltage and NEC® Class 2/PELV Connections Note: Provide proper short-circuit and overcurrent protection at the distribution panel. Maximum circuit breaker installation of 20 A. A Lutron® PP-120H or PP-277H power pack must be used to power the LUT-ELI-3PH unit when used with a bus supply. Both the power pack and the bus supplies must be fed from a normal/emergency supply. WARNING! Danger of shock. May result in serious injury or death. DO NOT WIRE WHEN LIVE! Switch off power to all power feeds via circuit breaker or isolator before wiring or servicing the LUT-ELI-3PH unit and EcoSystem lighting control system or Quantum system. Buttons and LEDs in the unit are used for troubleshooting. If wiring is exposed when accessing buttons and LEDs, the unit must be accessed by a certified electrician, following local codes. Wiring to EcoSystem Bus Supply *PP-120H or PP-277H 24 V (Red) 100-347 V 50/60 Hz 3-phase normal supply See Figure #1 or Figure #2 on page 2 of this guide. Power pack* Common (Black) Hot From 120 or 277 V Normal/Emergency supply 5 4 3 LED1 LED2 TEST 1 LED3 RADIOTOUCH 6 FACF NOT USED 2 GND PHASE CONTACTS 7 ´FACP´ N/O 8 CONTACTS 9 ´FACP´ N/C 10 COMMON MUX 11 +24VFW DRAIN 12 MUX SENSE Neutral S1 CLASS 2 LOW VOLTAGE WIRING (8) (7) (1) Common Common (pin 5) Bus supply 24 V Bus supply Emerg. signal (pin 6) 100-277 V Normal/ Emergency supply Connect up to 32 bus supplies Wiring to Quantum systems *PP-120H or PP-277H Hot Power From 120 or 277 V pack* Normal/Emergency supply Neutral 24 V (Red) Common (Black) 100-277 V Normal/Emergency supply 78 56 34 12 Common 5 4 3 LED2 LED1 1 LED3 2 TEST RADIOTOUCH 6 FACF NOTUSED CONTACTS 7 ´FACP´N/O 8 GND PHASE 9 CONTACTS 10 ´FACP´N/C 11 COMMON 12 +24VFW EM C MUX E2 MUX E1 DRAIN E2 SENSE E1 S1 CLASS2LOWVOLTAGEWIRING Connect up to 8 Quantum hubs Lutron® | 8 Emerg. signal (8) (7) (1) LUT-ELI-3PH Installation Guide Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Installing a LUT-ELI-3PH Unit in a GRAFIK Eye® QS Unit NEC® Class 2/PELV Connections WARNING! Danger of shock. May result in serious injury or death. DO NOT WIRE WHEN LIVE! Switch off power to all power feeds via circuit breaker or isolator before wiring or servicing the LUT-ELI-3PH unit and GRAFIK Eye QS unit. Buttons and LEDs in the unit are used for troubleshooting. If wiring is exposed when accessing buttons and LEDs, the unit must be accessed by a certified electrician, following local codes. • • • Notes Provide proper short-circuit and overcurrent protection at the distribution panel. Maximum circuit breaker installation of 20 A. When normal power loss is detected at the LUT-ELI-3PH unit, all zones in the GRAFIK Eye QS units will go to their emergency states. The GRAFIK Eye QS unit MUST be powered from a normal/emergency power feed. Wiring to a GRAFIK Eye QS Control Unit Note: For 1-phase 2-wire application, connect phase A, B, and C wires on LUT-ELI-3PH together for phase sensing. 100-347 V 50/60 Hz 3-phase Normal supply See Figure #1 or Figure #2 on page 2 of this guide. 12 9 8 7 6 5 4 3 LED1 LED2 TEST LED LED3 1 GND FACF RADIOTOUCH 2 PHASE NOTUSED C ONTACTS CONTACTS SENSE ´FACP´N/O ´FACP´ CP´N/O GRAFIK Eye QS unit QSGRJ model (back view) S1 TAGEWIRING (8) (7) (3) 18 AWG (1) Signal +24 V CCI SIG 24 V CCI Com 4 LUT-ELI-3PH Installation Guide 3 2 1 LED3 RADIOTOUCH 5 NOTUSED 6 CLASS2LOWVOLTAGEWIRING CONTACTS 7 ´FACP´N/O 8 CONTACTS 9 ´FACP´N/C 10 COMMON MUX 11 +24VFW DRAIN 12 MUX SENSE Common Normal/Emergency 20 A 120 V 1-Phase 2-Wire power feed (3) 12 AWG (2.5 mm²) 120-127 V or 220-240 V distribution panel Lutron® | 9 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Installing a LUT-ELI-3PH Unit with an Energi Savr NodeTM Unit(s) Notes: Provide proper short-circuit and overcurrent protection at the distribution panel. Maximum circuit breaker installation of 20 A. NEC® Class 2/PELV Connections • A Lutron® PP-120H or PP-277H power pack must be WARNING! Danger of shock. May result used to power the LUT-ELI-3PH unit when used with an in serious injury or death. DO NOT WIRE Energi Savr Node unit(s). Both the power pack and the WHEN LIVE! Switch off power to all power Energi Savr Node unit(s) must be fed from a normal/ feeds via circuit breaker or isolator before emergency supply. wiring or servicing the LUT-ELI-3PH and • When normal power loss is detected at the LUT-ELI-3Energi Savr Node unit. PH unit, all zones in the Energi Savr Node unit will go to Buttons and LEDs in the unit are used for their emergency states. troubleshooting. If wiring is exposed when accessing • The Energi Savr Node unit MUST be powered from a buttons and LEDs, the unit must be accessed by a normal/emergency power feed. certified electrician, following local codes. Wiring from Energi Savr Node Units Note: For 1-phase 2-wire application, connect phase A, B, and C wires on LUT-ELI-3PH together for phase sensing. Connections LUT-ELI-3PH Terminal 8 (+V Input) Energi Savr Node Unit ------------------------- Power Pack Red Wire Terminal 7 (Circuit Common) Com (Emergency CCI Input) Black Wire Terminal 1 (Signal) Emerg (Emergency CCI Input) --------------- 100-347 V 50/60 Hz 3-phase Normal supply See Figure #1 or Figure #2 on page 2 of this guide. PP-120H or PP-277H *+24 V (Red) 2 #12 Input Power (120 or 277 V ) Normal/Emergency Power 9 6 5 4 3 LED1 LED2 TEST LED3 1 FACF RADIOTOUCH 2 GND PHASE NOT USED ´FACP´ N/O CONTACTS 7 CONTACTS 8 ´FACP´ N/C 10 COMMON MUX 11 +24VFW DRAIN 12 MUX SENSE *Common (Black) S1 CLASS 2 LOW VOLTAGE WIRING (8) (7) (1) *Signal *Common *NEC Class 2/PELV Wiring 18 AWG (1.0 mm²) Note: Up to 32 QSN-4T16-S or QSN-4S16-S units can be connected to 1 LUT-ELI-3PH Lutron® | 10 *Signal *Common LUT-ELI-3PH Installation Guide Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Emergency Power Mode Setup: LCP128TM / Softswitch128® with LUT-ELI-3PH This step is only performed if an emergency pattern* is needed when normal power is lost. All control device inputs and time clock events are ignored while in emergency power mode. This step will define if the panel has emergency circuits and how to configure the emergency pattern. • For all the emergency (essential) lighting panels, move the emergency switches to the right position (see illustration below). • The essential and non-essential panels must be connected by a sense line wired to terminal 5 on the link connector on the LCP128/Softswitch128 controller (see illustration below). For wiring details, see the Installation Guide. * In this configuration, the emergency (essential) lighting panel will “sense” the normal panels’ power. When normal power is lost, the emergency panel will go to the emergency pattern (factory set to all circuits On). When normal power is restored, lighting circuits and contact closure outputs return to their previous state. Use Terminal 5 to connect a sense line between emergency and normal panels, or between the LUT-ELI-3PH unit and one or more emergency panels. An #18 AWG wire is recommended for the sense line. Notes: • If UL 924 certification is required, the Lutron® Emergency Lighting Interface (LUT-ELI-3PH) may be used to meet code. The LUT-ELI-3PH unit senses the normal (non-essential) line voltage on all three phases (3PH) of normal power. When one or more phases of power are lost, the LUT-ELI-3PH unit will send a signal to terminal 5 on the LCP128/Softswitch128 controller(s). When the emergency switch is set to the right position (essential) the emergency pattern will be recalled. The LUT-ELI-3PH unit can be used with one or multiple panel systems. • Loss of normal power can be simulated by turning off all connected normal (non-essential) panel control breakers. • When the emergency switch is in its center position (as shipped), terminal 5 the panel does not respond to emergency. Three position Emergency Switch is located at the bottom of the LCP128/Softswitch128 controller. 1 2 3 4 D 5 Left Position Right Position (Non-Essential) (Essential) Center Position (No response to Emergency) Top of the LCP128/Softswitch128 Controller LUT-ELI-3PH Installation Guide Lutron® | 11 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide NEC® Class 2/PELV Wiring to Fire Alarm Control Panel (FACP) • • Use only with normally open (terminals 3 and 4) or normally closed (terminals 5 and 6) dry contact closure. When the proper contact state is triggered, it must be maintained for the LUT-ELI-3PH unit to go into Emergency Mode. Once the contact is released, the LUT-ELI-3PH unit will return the GRAFIK SystemsTM GP, LP, XP panels, XPS, LCP, RadioTouch® controller, EcoSystem® Bus Supply, Energi Savr NodeTM unit, or Quantum® Bus Supply back to Normal operation mode. Normally Open FACP Input The LUT-ELI-3PH unit will have a factory installed jumper to provide the normally closed input signal for the supervisory circuit when a normally closed FACP input is not provided. Consult your Fire Alarm Control Panel’s instruction manual before connecting to the LUT-ELI-3PH unit. Do not connect any voltage source to the FACP inputs on the LUT-ELI-3PH unit. If voltage is provided by the FACP and connected to the LUTELI-3PH unit, it can damage the LUT-ELI-3PH unit. • • LUT-ELI-3PH unit 6 5 4 3 LED1 LED2 TEST LED3 1 GND 9 FACF RADIOTOUCH 2 PHASE NOTUSED CONTACTS ´FACP´N/O 7 CONTACTS 8 ´FACP´N/C 10 COMMON MUX 11 +24VFW DRAIN 12 MUX SENSE Fire Alarm Control Panel (provided by others) S1 Normally open CLASS2LOWVOLTAGEWIRING To 24 V Supervisory Circuit (Normally Closed FACP Input) Common power LUT-ELI-3PH unit 9 6 5 4 CLASS2LOWVOLTAGEWIRING To 24 V Lutron® | 12 3 S1 TEST LED2 FACF LED1 1 LED3 RADIOTOUCH 2 GND PHASE NOTUSED CONTACTS ´FACP´N/O 7 CONTACTS 8 ´FACP´N/C 10 COMMON MUX 11 +24VFW DRAIN 12 MUX SENSE Fire Alarm Control Panel (provided by others) Normally closed Common power LUT-ELI-3PH Installation Guide Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Troubleshooting RadioTouch® Symptom Lights are at full intensity and can not be controlled by an addressed transmitter Lights do not turn ON and do not go to high end when the test switch is pressed Lights do not turn ON and do not go to high end when one or more of the normal power phases are turned OFF Possible Cause Solution LUT-ELI-3PH unit is not connected to Signal on the RadioTouch Controller Connect terminal 2 ‘Occ Sig’ from the RadioTouch Controller to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit One or more of the phases feeding the LUT-ELI-3PH unit are off (phase LED on the LUT-ELI-3PH unit will be off) Turn ON all normal power phases to LUT-ELI-3PH unit Neutral is not connected on the LUT-ELI-3PH unit (phase LED on the LUT-ELI-3PH unit will be OFF) Connect neutral 24V is not connected on the LUT-ELI-3PH unit (phase LED on the LUT-ELI-3PH unit will be OFF) Connect terminal 4 ‘24V ’ from RadioTouch Controller to terminal 8 ‘+ V Input’ on the LUT-ELI-3PH unit There is a short across FACP and normally open contact (FACP LED will be ON) Remove short DIP switch 2 on the RadioTouch Controller is in the UP position Move DIP switch 2 on the RadioTouch Controller to the DOWN position 24V and signal wires are swapped Connect terminal 4 ‘24 V ’ from the RadioTouch Controller to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect terminal 2 ‘Occ Sig’ from the RadioTouch Controller to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit 24V and common wires are swapped Connect terminal 4 ‘24V ’ from the RadioTouch Controller to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect terminal 6 ‘Cir Com’ from the RadioTouch Controller to terminal 7 ‘Circuit Common’ on the LUT-ELI3PH unit Common and signal wires are swapped Connect terminal 6 ‘Cir Com’ from the RadioTouch Controller to terminal 7 ‘Circuit Common’ on the LUTELI-3PH unit and connect terminal 2 ‘Occ sig’ from the RadioTouch Controller to terminal 1 ‘Signal’ on the LUT-ELI3PH unit DIP switch 2 on the RadioTouch Controller is in the UP position Move DIP switch 2 on the RadioTouch Controller to the DOWN position 24V Connect terminal 4 ‘24V ’ from the RadioTouch Controller to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect terminal 2 ‘Occ Sig’ from the RadioTouch Controller to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit and signal are swapped That RadioTouch Controller is not powered by the emergency circuit power Power the RadioTouch Controller from the emergency circuit and not from normal The emergency transfer switch is not switching over Consult transfer switch manufacture for troubleshooting LUT-ELI-3PH unit is connected to the emergency circuit Connect the LUT-ELI-3PH unit to normal power 24V and common wires are swapped Connect terminal 4 ‘24V ’ from the RadioTouch Controller to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect terminal 6 ‘Cir Com’ from the RadioTouch Controller to terminal 7 ‘Circuit Common’ on the LUT-ELI3PH unit Common and signal wires are swapped Connect terminal 6 ‘Cir Com’ from the RadioTouch Controller to terminal 7 ‘Circuit Common’ on the LUTELI-3PH unit and connect terminal 2 ‘Occ Sig’ from the RadioTouch Controller to terminal 1 ‘Signal’ on the LUT-ELI3PH unit LUT-ELI-3PH Installation Guide Lutron® | 13 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Troubleshooting Panel Based Systems Symptom Possible Cause Lights are at full intensity and can not be controlled by the wallstation (Circuit selector/ controller reads “ord”), or controller reads Emergency Mode Sense wire is not connected from the Circuit selector/controller to the LUT-ELI-3PH unit Connect terminal 5 ‘Sense’ from the Circuit selector/ controller to terminal 12 ‘Sense’ on the LUT-ELI-3PH unit One or more of the phases feeding the LUT-ELI-3PH unit are off (phase LED on the LUT-ELI-3PH unit will be OFF) Turn ON all normal power phases to LUT-ELI-3PH unit Neutral is not connected on the LUT-ELI-3PH unit (phase LED on the LUT-ELI-3PH unit will be OFF) Connect neutral 24VFW is not connected on the LUT-ELI-3PH unit (phase LED on the LUT-ELI-3PH unit will be OFF) Connect terminal 2 ‘24VFW’ from the Circuit selector/ controller to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit There is a short across FACP and normally open contact (FACP LED will be ON) Remove short 24VFW and sense wires are swapped Connect terminal 2 ‘24VFW’ from the Circuit selector/ controller to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect terminal 5 ‘Sense’ from the Circuit selector/ controller to terminal 12 ‘Sense’ on the LUT-ELI-3PH unit Common and sense wires are swapped Connect terminal 1 ‘Common’ from the Circuit selector/ controller to terminal 7 ‘Circuit Common’ on the LUT-ELI3PH unit and connect terminal 5 ‘Sense’ from the Circuit selector/controller to terminal 12 ‘Sense’ on the LUT-ELI3PH unit Lights do not turn ON and do not go to high end when the test switch is pressed SW6 on the Circuit selector/ controller is in the middle position or far left position Move SW6 on the Circuit selector/controller to the far right position 24V and common wires are swapped Connect terminal 2 ‘24VFW’ from the Circuit selector/ controller to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect terminal 1 ‘Common’ from the Circuit selector/ controller to terminal 7 ‘Circuit Common’ on the LUT-ELI3PH unit Lights do not turn ON and do not go to high end when one or more of the normal power phases are turned OFF SW6 on the Circuit selector/ controller is in the middle position or far left position Move SW6 on the Circuit selector/controller to the far right position 24 V and common wires are swapped Connect terminal 2 ‘24VFW’ from the Circuit selector/ controller to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect terminal 1 ‘Common’ from the Circuit selector/ controller to terminal 7 ‘Circuit Common’ on the LUT-ELI3PH unit That Emergency Panel is not powered by the emergency circuit Power the Emergency Panel from the emergency circuit and not from normal power The emergency transfer switch is not switching over Consult transfer switch manufacture for troubleshooting LUT-ELI-3PH unit is connected to the emergency circuit Connect the LUT-ELI-3PH unit to normal power Lutron® | 14 Solution LUT-ELI-3PH Installation Guide Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Troubleshooting Energi Savr NodeTM Installations Symptom Possible Cause Solution Signal wire is not connected from the LUT-ELI-3PH unit to the Energi Savr Node unit Connect ‘Emerg’ terminal from the Energi Savr Node unit to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit One or more of the phases feeding the LUT-ELI-3PH unit are off (phase LED on the LUT-ELI-3PH unit will be OFF) Turn ON all normal power phases to LUT-ELI-3PH unit Neutral is not connected on the LUT-ELI-3PH unit (phase LED on the LUT-ELI-3PH unit will be OFF) Connect neutral 24VFW is not connected on the LUT-ELI-3PH unit (phase LED on the LUT-ELI-3PH unit will be OFF) Connect red wire (24 V ) from the PP-120H or PP-277H unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit There is a short across FACP and normally open contact (FACP LED will be ON) Remove short Lights do not turn ON and do not go to high end when the test switch is pressed 24 V and common wires are swapped Connect red wire (24 V ) from the PP-120H or PP-277H unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect black wire (Common) from the PP-120H or PP-277H unit to terminal 7 ‘Circuit Common’ on the LUT-ELI-3PH unit Lights do not turn ON and do not go to high end when one or more of the normal power phases are turned OFF 24 V and common wires are swapped Connect red wire (24 V ) from the PP-120H or PP-277H unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect black wire (Common) from the PP-120H or PP-277H unit to terminal 7 ‘Circuit Common’ on the LUT-ELI-3PH unit Emergency Panel is not powered by the emergency circuit Power the Emergency Panel from the emergency circuit and not from normal power The emergency transfer switch is not switching over Consult transfer switch manufacturer for troubleshooting LUT-ELI-3PH unit is connected to the emergency circuit Connect the LUT-ELI-3PH unit to normal power Lights are at full intensity. Unit will not respond to local control or input signals. LUT-ELI-3PH Installation Guide Lutron® | 15 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Troubleshooting EcoSystem® or Quantum® System Installations Symptom Lights are at full intensity. System will not respond to local control or input signals. Possible Cause Solution Signal wire is not connected from the Connect ‘CCI-EMERG’ terminal from the Ecosystem bus supply to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit LUT-ELI-3PH unit to the Ecosystem bus supply Signal wire is not connected from the Connect ‘EM’ terminal from the Quantum bus supply to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit LUT-ELI-3PH unit to the Quantum bus supply One or more of the phases feeding the LUT-ELI-3PH unit are off (phase LED on the LUT-ELI-3PH unit will be OFF) Turn on all normal power phases to LUT-ELI-3PH unit Neutral is not connected on the LUT- Connect neutral ELI-3PH unit (phase LED on the LUTELI-3PH unit will be OFF) 24VFW is not connected on the LUT- Connect red wire (24 V ) from the PP-120H or PPELI-3PH unit (phase LED on the LUT- 277H unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH ELI-3PH unit will be OFF) unit There is a short across FACP and normally open contact (FACP LED will be ON) Remove short Lights do not turn ON and do not go to high end when the test switch is pressed 24 V and common wires are swapped Connect red wire (24 V ) from the PP-120H or PP277H unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect black wire (Common) from the PP-120H or PP-277H unit to terminal 7 ‘Circuit Common’ on the LUT-ELI-3PH unit Lights do not turn ON and do not go to high end when one or more of the normal power phases are turned OFF 24 V and common wires are swapped Connect red wire (24 V ) from the PP-120H or PP277H unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect black wire (Common) from the PP-120H or PP-277H unit to terminal 7 ‘Circuit Common’ on the LUT-ELI-3PH unit Emergency Panel is not powered by the emergency circuit Power the Emergency Panel from the emergency circuit and not from normal power The emergency transfer switch is not Consult transfer switch manufacturer for troubleshooting switching over LUT-ELI-3PH unit is connected to the emergency circuit Lutron® | 16 Connect the LUT-ELI-3PH unit to normal power LUT-ELI-3PH Installation Guide Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Troubleshooting a GRAFIK Eye® QS Installation Symptom Possible Cause Solution Lights are at full intensity. System will not respond to local control or input signals. LUT-ELI-3PH unit is not connected to ‘CCI SIG’ on the GRAFIK Eye QS unit Connect the ‘CCI SIG’ terminal from the GRAFIK Eye QS unit to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit One or more of the phases feeding the LUT-ELI-3PH unit are off (phase LED on the LUT-ELI-3PH unit will be off) Turn on all normal power phases to LUT-ELI-3PH unit Neutral is not connected on the Connect neutral LUT-ELI-3PH unit (phase LED on the LUT-ELI-3PH unit will be OFF) 24 V is not connected on the Connect the ‘24 V ’ terminal from the GRAFIK Eye QS LUT-ELI-3PH unit (phase LED on the unit to terminal 8 ‘+ V Input’ on the LUT-ELI-3PH unit LUT-ELI-3PH unit will be OFF) There is a short across FACP and normally open contact (FACP LED will be ON) Lights do not 24 V and signal are swapped turn ON and do not go to high end when the test switch is 24 V and common wires are pressed swapped Lights do not turn ON and do not go to high end when one or more of the normal power phases are turned OFF Remove short Connect the ‘24 V ’ terminal from the GRAFIK Eye QS unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect the ‘CCI SIG’ terminal from the GRAFIK Eye QS unit to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit Connect the ‘24 V ’ terminal from the GRAFIK Eye QS unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect the ‘CCI Com’ terminal from the GRAFIK Eye QS unit to terminal 7 ‘Circuit Common’ on the LUT-ELI-3PH unit Common and signal are swapped Connect the ‘CCI Com’ terminal from the GRAFIK Eye QS unit to terminal 7 ‘Circuit Common’ on the LUT-ELI-3PH unit and connect the ‘CCI SIG’ terminal from the GRAFIK Eye QS unit to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit GRAFIK Eye QS unit ‘CCI SIG’ input has not been set up as an emergency input Refer to programming guide for the GRAFIK Eye QS unit on how to program the ‘CCI SIG’ input as an emergency input. 24V and signal are swapped Connect the ‘24 V ’ terminal from the GRAFIK Eye QS unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect the ‘CCI SIG’ terminal from the GRAFIK Eye QS unit to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit The GRAFIK Eye QS unit is not pow- Power the GRAFIK Eye QS unit from the emergency circuit ered by the emergency circuit power and not from normal The emergency transfer switch is not switching over Consult transfer switch manufacture for troubleshooting LUT-ELI-3PH unit is connected to the emergency circuit Connect the LUT-ELI-3PH unit to normal power 24 V and common wires are swapped Connect the ‘24 V ‘ terminal from the GRAFIK Eye QS unit to terminal 8 ‘+V Input’ on the LUT-ELI-3PH unit and connect the ‘CCI Com’ terminal from the GRAFIK Eye QS unit to terminal 7 ‘Circuit Common’ on the LUT-ELI-3PH unit Common and signal wires are swapped Connect the ‘CCI Com’ terminal from the GRAFIK Eye QS unit to terminal 7 ‘Circuit Common’ on the LUT-ELI-3PH unit and connect the ‘CCI SIG’ terminal from the GRAFIK Eye QS unit to terminal 1 ‘Signal’ on the LUT-ELI-3PH unit GRAFIK Eye QS unit ‘CCI SIG’ input has not been set up as an emergency input Refer to programming guide for the GRAFIK Eye QS unit on how to program the ‘CCI SIG’ input as an emergency input. LUT-ELI-3PH Installation Guide Lutron® | 17 Emergency Lighting Interface LUT-ELI-3PH | Installation Guide NOTES: LUT-ELI-3PH Installation Guide Emergency Lighting Interface LUT-ELI-3PH | Installation Guide NOTES: LUT-ELI-3PH Installation Guide Emergency Lighting Interface LUT-ELI-3PH | Installation Guide Lutron Electronics Co., Inc. One Year Limited Warranty For a period of one year from the date of purchase, and subject to the exclusions and restrictions described below, Lutron warrants each new unit to be free from manufacturing defects. Lutron will, at its option, either repair the defective unit or issue a credit equal to the purchase price of the defective unit to the Customer against the purchase price of comparable replacement part purchased from Lutron. Replacements for the unit provided by Lutron or, at its sole discretion, an approved vendor may be new, used, repaired, reconditioned, and/or made by a different manufacturer. If the unit is commissioned by Lutron or a Lutron approved third party as part of a Lutron commissioned lighting control system, the term of this warranty will be extended, and any credits against the cost of replacement parts will be prorated, in accordance with the warranty issued with the commissioned system, except that the term of the unit’s warranty term will be measured from the date of its commissioning. EXCLUSIONS AND RESTRICTIONS This Warranty does not cover, and Lutron and its suppliers are not responsible for: 1. Damage, malfunction or inoperability diagnosed by Lutron or a Lutron approved third party as caused by normal wear and tear, abuse, misuse, incorrect installation, neglect, accident, interference or environmental factors, such as (a) use of incorrect line voltages, fuses or circuit breakers; (b) failure to install, maintain and operate the unit pursuant to the operating instructions provided by Lutron and the applicable provisions of the National Electrical Code and of the Safety Standards of Underwriter's Laboratories; (c) use of incompatible devices or accessories; (d) improper or insufficient ventilation; (e) unauthorized repairs or adjustments; (f) vandalism; or (g) an act of God, such as fire, lightning, flooding, tornado, earthquake, hurricane or other problems beyond Lutron’s control. 2. On-site labor costs to diagnose issues with, and to remove, repair, replace, adjust, reinstall and/ or reprogram the unit or any of its components. 3. Equipment and parts external to the unit, including those sold or supplied by Lutron (which may be covered by a separate warranty). 4. The cost of repairing or replacing other property that is damaged when the unit does not work properly, even if the damage was caused by the unit. EXCEPT AS EXPRESSLY PROVIDED IN THIS WARRANTY, THERE ARE NO EXPRESS OR IMPLIED WARRANTIES OF ANY TYPE, INCLUDING ANY IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. LUTRON DOES NOT WARRANT THAT THE UNIT WILL OPERATE WITHOUT INTERRUPTION OR BE ERROR FREE. NO LUTRON AGENT, EMPLOYEE OR REPRESENTATIVE HAS ANY AUTHORITY TO BIND LUTRON TO ANY AFFIRMATION, REPRESENTATION OR WARRANTY CONCERNING THE UNIT. UNLESS AN AFFIRMATION, REPRESENTATION OR WARRANTY MADE BY AN AGENT, EMPLOYEE OR REPRESENTATIVE IS SPECIFICALLY INCLUDED HEREIN, OR IN STANDARD PRINTED MATERIALS PROVIDED BY LUTRON, IT DOES NOT FORM A PART OF THE BASIS OF ANY BARGAIN BETWEEN LUTRON AND CUSTOMER AND WILL NOT IN ANY WAY BE ENFORCEABLE BY CUSTOMER. IN NO EVENT WILL LUTRON OR ANY OTHER PARTY BE LIABLE FOR EXEMPLARY, CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFITS, CONFIDENTIAL OR OTHER INFORMATION, OR PRIVACY; BUSINESS INTERRUPTION; PERSONAL INJURY; FAILURE TO MEET ANY DUTY, INCLUDING OF GOOD FAITH OR OF REASONABLE CARE; NEGLIGENCE, OR ANY OTHER PECUNIARY OR OTHER LOSS WHATSOEVER), NOR FOR ANY REPAIR WORK UNDERTAKEN WITHOUT LUTRON’S WRITTEN CONSENT ARISING OUT OF OR IN ANY WAY RELATED TO THE INSTALLATION, DEINSTALLATION, USE OF OR INABILITY TO USE THE UNIT OR OTHERWISE UNDER OR IN CONNECTION WITH ANY PROVISION OF THIS WARRANTY, OR ANY AGREEMENT INCORPORATING THIS WARRANTY, EVEN IN THE EVENT OF THE FAULT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY, BREACH OF CONTRACT OR BREACH OF WARRANTY OF LUTRON OR ANY SUPPLIER, AND EVEN IF LUTRON OR ANY OTHER PARTY WAS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. NOTWITHSTANDING ANY DAMAGES THAT CUSTOMER MIGHT INCUR FOR ANY REASON WHATSOEVER (INCLUDING, WITHOUT LIMITATION, ALL DIRECT DAMAGES AND ALL DAMAGES LISTED ABOVE), THE ENTIRE LIABILITY OF LUTRON AND OF ALL OTHER PARTIES UNDER THIS WARRANTY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, USE, REPAIR, OR REPLACEMENT OF THE UNIT, OR ANY AGREEMENT INCORPORATING THIS WARRANTY, AND CUSTOMER'S SOLE REMEDY FOR THE FOREGOING, WILL BE LIMITED TO THE AMOUNT PAID TO LUTRON BY CUSTOMER FOR THE UNIT. THE FOREGOING LIMITATIONS, EXCLUSIONS AND DISCLAIMERS WILL APPLY TO THE MAXIMUM EXTENT ALLOWED BY APPLICABLE LAW, EVEN IF ANY REMEDY FAILS ITS ESSENTIAL PURPOSE. TO MAKE A WARRANTY CLAIM To make a warranty claim, promptly notify Lutron within the warranty period described above by calling the Lutron Technical Support Center at (800) 523-9466. Lutron, in its sole discretion, will determine what action, if any, is required under this warranty. To better enable Lutron to address a warranty claim, have the unit's serial and model numbers available when making the call. If Lutron, in its sole discretion, determines that an on-site visit or other remedial action is necessary, Lutron may send a Lutron Services Co. representative or coordinate the dispatch of a representative from a Lutron approved vendor to Customer's site, and/or coordinate a warranty service call between Customer and a Lutron approved vendor. NEC is a registered trademark of National Fire Protection Association, Quincy, Massachusetts. Belden is a registered trademark of Belden, Inc., Richmond, Indiana. Liberty Wire & Cable is a registered trademark of Liberty Wire & Cable, Colorado Springs, Colorado. Lutron, EcoSystem, GRAFIK Eye, Quantum, RadioTouch, Softswitch128, and the sunburst logo are registered trademarks and Energi Savr Node and LCP128 are trademarks of Lutron Electronics Co., Inc. © 2010 Lutron Electronics Co, Inc. LUT-ELI-3PH Installation Guide Internet: www.lutron.com WORLD HEADQUARTERS Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. TOLL FREE: 1.800.523.9466 (U.S.A., Canada, and the Caribbean) Tel: +1.610.282.3800 Fax: +1.610.282.1243 EUROPEAN HEADQUARTERS Lutron EA Ltd. Lutron House 6 Sovereign Close Wapping London, E1W 3JF, UK FREEPHONE: 0800.282.107 (U.K.) Tel: +44.(0)20.7702.0657 Fax: +44.(0)20.7480.6899 ASIAN HEADQUARTERS Singapore Lutron GL, Ltd. 15 Hoe Chiang Road #07-03 Tower Fifiteen Singapore 089316 TOLL FREE: 800.120.4491 Tel: +65.6220.4666 Fax: +65.6220.4333 HONG KONG SALES OFFICE Tel: +852.2104.7733 Fax: +852.2104.7633 Lutron Electronics Co., Inc., reserves the right to make improvements or changes in its products without prior notice. Although every attempt is made to ensure that this information is accurate and up to date, please check with Lutron to confirm product availability, latest specifications and suitability for your application. Printed in the U.S.A. P/N 031-353 Rev. A 09/10