CEILING &WALL SYSTEMS CI/SfB Between us, ideas become reality ® (35) Xy September 2012 Suspension Systems Catalogue 2013 / 2014 S UMMARY ARMSTRONG SUSPENSION SYSTEMS Armstrong’s Philosophies Armstrong’s Commitment to the Environment CE Marking Armstrong Projects The Range TECHNICAL INFORMATION Fire Tests Load Capacity Matrix 1 2 3 4 5 6 - 22 16 20 PRODUCT RANGE DESIGN OPTIONS Axiom Transitions Axiom Profiles Axiom Classic Canopy Axiom Knife Edge Canopy Axiom Circle & Curved Silhouette 15 XL2 Interlude 15 XL2 Microline environment quality/CE marking product innovation 22 24 26 28 30 32 34 36 service GENERAL APPLICATIONS Designed for fast and easy installation Prelude 15 Prelude 24 XL2 Prelude 24 TLX Prelude Sixty2 Prelude 35 XL2 Bandraster System Z Drywall Grid System 38 40 42 44 46 48 50 52 CORRIDOR Drywall Grid System Shortspan Prelude Sixty2 54 55 SPECIFIC APPLICATIONS Clean Room 24 mm Grid System Corrosive Resistant 24 mm Grid System Seismic Solution LongSpan System 56 58 60 62 PERIMETER TRIM AND ACCESSORIES Flexible Perimeter Trim Perimeter Solutions - Mineral Ceilings Perimeter Solutions - Metal Ceilings Accessories 64 66 68 70 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie ARMSTR ONG ’S P HILOS OPHIES SERVICE TOTAL CEILING SOLUTIONS Suspension systems are manufactured in three European plants, strategically located to serve all our European customers. Additionally, both Armstrong and WAVE can draw upon their global manufacturing capabilities for both speciality products and manufacturing support. In addition to WAVE’s manufacturing sites, Armstrong stocks suspension systems in distribution centres throughout Europe. This allows our customers the convenience of mixed product shipments, combining suspension systems with other Armstrong ceiling products, optimising bulk shipments direct from their manufacturing locations. The suspension system product range forms an integral part of Armstrong’s total ceiling solutions policy. Armstrong now offers its customers and specifiers a complete range of ceiling panels including mineral, soft fibre, wood and metal and a wider choice than ever of suspension systems. Armstrong can provide solutions for all elements in today’s challenging construction environments. QUALITY Suspension systems are manufactured for Armstrong both by its joint venture company WAVE (Worthington Armstrong Venture) and through various alliances with other companies who are regarded as specialists in their fields of engineering. WAVE operates on a global basis, and brings to its various European operations world class practice on the most technologically advanced equipment. WAVE WAVE has three manufacturing locations in Europe, three in the USA including the facility in Aberdeen, Maryland which is one of the world’s largest grid facilities, plus one in China. INTEGRATION Suspension systems are designed for integration with Armstrong's portfolio of ceiling products, mineral, soft fibre, metal, wood and special solutions. TEAM VALLEY MOSCOW MUNSTER STAFFORD VALENCIENNES RANKWEIL PONTARLIER BENTON HARBOUR MADRID ABERDEEN / MALVERN SHANGHAI LAS VEGAS MUMBAI Metal ceiling plants Grid plants Mineral fibre plants Distribution centres 1 ARMSTR ONG’S COMMITMENT TO THE ENV IRONMENT Our environmental efforts in the life-cycle of our products start with design. fi DESIGN MANUFACTURING • • • • - • Innovative design creates stronger sections. Reuse of waste materials Raw materials for ceilings are renewable and abundant in nature. Recycled content varies by product: Suspension system - contain 25% post-consumer recycled content • • Suspension system Main Runners and Cross Tees are rotary stitched by a patented method to deliver extra strength and stability. All in process scrap is recycled back into the process. Suspension systems and panels are manufactured at several locations, thereby reducing transportation costs and environmental impacts associated with transportation. fi fi RECYCLE INSTALLATION • • • • Integrate technology to reduce installation time. Optimised packaging material - less waste on site. • Up to 100% of the packaging is made from recycled material. Suspension systems contain up to 25% post-consumer recycled content End of Life ceiling tile recycling scheme. fi In several countries, we support the recollection of packaging. • fi RETHINK PRODUCTS Continuous development of innovative thin gauge products. fi MAINTENANCE • • Minimal maintenance and easy to replace. Armstrong has an expanding portfolio of sustainable products, these include: > Hot-dipped galvanised suspension systems provide superior resistance to rust and corrosion. WARRANTY ON USE A history of quality products. Various warranty options are available on ceilings systems. fi • • 2 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie CE Marking What is it ? CE stands for Conformité Européenne, which translated literally, means “European Conformity”. The CE mark is a products “passport” for entry into the EEA (European Economic Area) and indicates that the product complies with the requirements of the applicable European Directive. For suspended ceilings, the way in which we must test and communicate performance for these essential requirements has been defined in EN 13964 Suspended Ceilings – Requirements and Test Methods. For construction products the European Directive is the Construction Products Directive (89/106/ EEC), however, this is being replaced by the Construction Products Regulations (305/2011/EU) which will come into full force on 1st July 2013. What does this mean? The CPD identifies the essential requirements for products (and total projects) such that they are fit for intended use as: • mechanical resistance and stability; • safety in case of fire; • hygiene, health and environment; • safety in use; • protection against noise; • energy economy and heat retention. This standard identifies how the ceiling components must be tested against the essential requirements to identify a performance classification. It also indicates how the manufacturer must ensure that their products maintain these levels of performance on an ongoing basis. On 1st July 2007, it became mandatory for all suspended ceilings and accompanying suspension systems (in the scope of EN 13964) to carry the CE mark and the accompanying essential requirement test information. Since 1st July 2007, non-CE marked materials are no longer saleable into the EEA. BRE BUILDING RESEARCH ESTABLISHMENT At Armstrong, we’re proud to be a recognised pioneer in green practices, with successful methods to produce environmentally preferable products, prevent pollution and reduce waste. We’re the only UK mineral ceiling manufacturer with a BRE Ecopoint profile – an external certification of our compliance with ISO 14041 and ISO 21930 standards. Our Ecopoint score in 2007 was 0.10, a significant improvement on 2004, and we’re working on lowering it even further. 3 ARMSTR ONG P R OJECTS Armstrong World Industry (USA) - Axiom Circle Canopy Uttoxeter Cinema (UK) Coloured Prelude 24 4 Concordia Hotel (IT) - Axiom C Canopy Medis Office (SI) - Silhouette Dutch Technology Leiden (NL) - System Z Hospital Ruzomberok (SK) - Clean Room Grid. Lothar Meyer School (DE) Telefonica Center (SP) - Bandraster 5 THE SUSP ENSION R ANG E The suspension systems include a full range of solutions for all ceiling suspension requirements. • General applications, a range of standard Prelude 24mm and Prelude 15mm grid systems, Bandraster and Prelude Sixty2 for longer spans. Drywall Grid Systems are available for plasterboard ceilings. • Designer options including the minimalist grid Silhouette, Microline, Interlude and the Axiom range. • Specific applications, for clean room and higher humidity environments. • Perimeter trims and accessories, for most applications. We also include our comprehensive programme of special size options that is available in most ranges. A range of either stab or hook systems are available to meet the mechanical preferences of the installer. To complete the portfolio we also offer a technical test programme that provides fire, loadings and environmental accreditation. Suspension systems are designed for use with a wide variety of Armstrong ceiling products, mineral, soft fibre, metal, wood and special solutions. Peakform is an innovative design for Main Runners and Cross Tees. The taller Peakform profiles are engineered to create a stronger, more stable suspension system making installation both faster and easier. Superlock is an industry first staked-on clip for Main Runners which provides tighter, secure bulb-to-bulb connections; connections are confirmed by an audible click; Main Runners are easily disconnected and reconnected laterally. 6 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie W HER E INNOVATION MEETS P ERF ORMANCE VOICE OF THE CUSTOMER OTHER SYSTEMS Customer input is an extremely valuable part of our product innovation progress. Armstrong hold regular voice of customer work sessions to help develop the most innovative products and systems to meet the customer’s needs. Our extensive range of performance grids also includes Bandraster, Prelude Sixty2, Prelude 35, System Z and LongSpan. Specific grid solutions such as Clean Room Grid, Seismic Grid and Corrosive Resistant grid completes Armstrong's suspension solutions. HOT DIPPED GALVINISED STEEL: Inhibits red rusting better and longer than electro galvanised or painted systems • Installation of grid can start before the building is enclosed or HVAC system is operational. • Long term system performance because entire system is hot dipped galvanised steel. PHYSICAL DETAIL All grids are made from double-web galvanised steel with a surface finish of baked polyester paint. STITCHING All Prelude components feature a unique “stitched” construction. The two metal layers of the vertical web are mechanically locked together in a sophisticated in-line process. Stitching enhances the torsional resistance and general “feel” of the Prelude components. THIN GAUGE TECHNOLOGY: Up to 50% lighter carton weight than the competition enables easier handling on site, plus the added benefit of the Peakform bulb allows easy cutting of the grid. DESIGNER GRIDS Armstrong’s designer range, Silhouette, Microline, Interlude, Axiom System and Axiom Canopies provide aesthetically enhanced grids. Silhouette creates a level ceiling surface, providing a flush appearance while Interlude gives a clean sophisticated visual that is created by the unique double reveal. Axiom Profiles and Transitions provide an aesthetic solution for changes in level and a flush transition with plaster margins. Axiom Canopies are a perimeter trim system designed to create “ceiling clouds” in conjunction with full size tiles. Microline is a steel based grid with aluminium extrusion. The exposed sleeve provides a clean and crisp visual plus a practical fluted reveal for flexibility in partition fixing and relocation. FULL RANGE OF ACCESSORIES AND PERIMETER SOLUTIONS Suspension systems are offered with a complete range of commonly required accessories and perimeter solutions. 7 AR MSTR ONG SYSTEMS PRELUDE UNIVERSAL MAIN RUNNER The Prelude Universal Main Runner supports the installation of either hook/butt cut or stab/override Cross Tees from one simple inventory of Main Runners. The universal system is available in Peakform design in both 24mm and 15mm widths. The Peakform Universal Main Runners feature a firm, quick and easy assembled Main Runner to Main Runner / bulb-to-bulb connection. Metric sized Main Runners are slotted at 100mm centres for more flexibility. Slots are machined to receive positive and accurate assembly of either Prelude TL and TLX (hook installation) or Prelude XL2 (stab installation) Cross Tees. The staked-on Superlock clip allows for Main Runners to be disconnected and reconnected laterally in low-clearance areas or in the middle of a room. TL TLX PRELUDE XL2 WHERE INNOVATION MEETS P ER F OR MANCE SEISMIC Rx® SYSTEM Armstrong Seismic Rx® System is a fully and independently tested approach to achieving ceiling installations that can withstand the forces associated with significant seismic activity or other severe events. In addition to earthquakes, there are several other industries with associated risks (e.g. Blast protection) where the use of Seismic Rx® System will provide additional protection for the ceiling e.g. • Nuclear installations • Defence establishments • Chemical installations • Transport installations (with intermittent vibrations) The Seismic Rx® system provides the additional security required for seismic resistance using specifically designed elements for minimised installation complexity with maximum performance. 8 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie PRELUDE XL2 “CLICK” INSTALLATION Prelude XL2 Cross Tees in both 24mm and 15mm widths feature an advanced stab system that locates with an audible “click”, ensuring a solid installation at all times. The stab end is precision stamped from a separate piece of high grade steel permitting an increased accuracy and economy of production over the more conventional integral forming of the Cross Tee ends. A selected range of standard Prelude 15/24 XL2 Cross Tees feature the new Peakform design. The Cross Tees are inserted to the right of each other through the Main Runner slots and easily pushed home. PRELUDE TLX TLX is a new highly engineered staked-on hook system, with a patented clip. Its unique steel-based composite material and shape provide a stronger and level connection, an improved fire performance and an increased overall stability.TLX Cross Tees are quicker and easier to cut due to the Peakform section. When the TLX Cross Tees are inserted to the right of each other through the Main Runner slots, the TLX clip provides a more secure installation. PRELUDE TL “HOOK” INSTALLATION Prelude TL Cross Tees in 15mm width feature an integrally formed hook nose. This popular installation system has been a feature of Armstrong suspension systems for over 20 years and its proven ease of assembly and precise butt cut joint has been a favourite of installers. Cross Tee alignment is ensured by locating the tees to the right hand side of the adjoining section. 9 STANDAR D COLOURS Armstrong suspension system components are manufactured in a range of colours and metal finishes including Global White to complement Armstrong ceiling tiles. For complete information call Armstrong Technical Sales. GLOBAL WHITE SILVER GREY (GW) RAL 9006 (SG) CARRARA (CA) PLATINUM (PN) BLACK (BK) WHITE RAL9010 (WR) GLOBAL WHITE (GW) BRASS (BS) CHROME (CE) WHITE RAL9010 (WR) GALVANISED BLACK/WHITE Prelude 24 TLX Prelude 24 XL2 Prelude 15 XL2/TL Silhouette XL2 6mm Silhouette XL2 3mm Interlude Bandraster Prelude 35 Prelude Sixty2 Corrosive Resistant Clean Room Grid Axiom System Steel based capping Other than Steel based Painted perimeter trim items are available in Global White and capped angle T 1924 CA is available in all colours except black/white and galvanised. Please contact Armstrong Technical Sales Group for further details. 10 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie COLOUR PALLET • • • Stimulate your imagination to create vibrant interior spaces using custom colour solutions. Choice of more than 180 custom colours upon request. Available for Prelude 15 and Prelude 24 and specific perimeter trims. DETAILS 15 mm Cross Tee and Main Runner 24 mm Cross Tee and Main Runner 15mm 24mm Colour Selection Due to printing limitations, shade may vary from actual product. RAL 1000 RAL 1001* RAL 1002 RAL 1003 RAL 1004 RAL 1005 RAL 1006 RAL 1007* RAL 1011 RAL 1012 RAL 1013* RAL 1014 RAL 1015* RAL 1016 RAL 1017 RAL 1018 RAL 1019* RAL 1020 RAL 1021* RAL 1024 RAL 1027 RAL 1028 RAL 1032 RAL 1033 RAL 1034 RAL 2000* RAL 2001 RAL 2002* RAL 2003 RAL 2004* RAL 2008 RAL 2010 RAL 2011 RAL 2012 RAL 3000* RAL 3001 RAL 3002* RAL 3003 RAL 3004 RAL 3005 RAL 3007 RAL 3009 RAL 3011 RAL 3012 RAL 3013 RAL 3014 RAL 3015 RAL 3016 RAL 3017 RAL 3018 RAL 3022 RAL 3027 RAL 3031 RAL 4001 RAL 4002 RAL 4003 RAL 4004 RAL 4005 RAL 4007 RAL 4008 RAL 4009 RAL 5000 RAL 5001 RAL 5002 RAL 5003* RAL 5004 RAL 5005 RAL 5007 RAL 5008 RAL 5009* RAL 5010* RAL 5011 RAL 5012* RAL 5013 RAL 5014 RAL 5015* RAL 5018 RAL 5019 RAL 5020 RAL 5021 RAL 5022 RAL 5024 RAL 6000 RAL 6001 RAL 6002 RAL 6003 RAL 6004 RAL 6005 RAL 6006 RAL 6007 RAL 6008 RAL 6009 RAL 6010 RAL 6011* RAL 6012 RAL 6013 RAL 6014 RAL 6015 RAL 6016 RAL 6017 RAL 6018 RAL 6019 RAL 6020 RAL 6021 RAL 6022 RAL 6025 RAL 6026 RAL 6027 RAL 6028 RAL 6029 RAL 6032 RAL 7000 RAL 7001* RAL 7002 RAL 7003 RAL 7004 RAL 7005 RAL 7006 RAL 7008 RAL 7009 RAL 7010 RAL 7011 RAL 7012* RAL 7013 RAL 7015 RAL 7016* RAL 7021* RAL 7022 RAL 7023 RAL 7024 RAL 7026 RAL 7030* RAL 7031* RAL 7032* RAL 7033 RAL 7034 RAL 7035* RAL 7036 RAL 7037 RAL 7038* RAL 7039 RAL 7040* RAL 7044* RAL 8000 RAL 8001 RAL 8002 RAL 8003 RAL 8004 RAL 8007 RAL 8008 RAL 8011 RAL 8012 RAL 8014* RAL 8015 RAL 8016 RAL 8017 RAL 8019* RAL 8022 RAL 8023 RAL 8024 RAL 8025 RAL 8028 RAL 9001* RAL 9002* RAL 9003* RAL 9004 RAL 9005* RAL 9010* RAL 9011* RAL 9018* RAL 1023 RAL 2009 RAL 3020 RAL 4006 RAL 5017 RAL 6024 RAL 7042 RAL 7043 RAL 9016* RAL 9017 *Matt finish items are available as a special order. RAL CLASSIC: Important notice: This ORIGINAL RAL colour chart (card) has gone through stringent quality testing by RAL. Only the use of the individual cards of the registers RAL 840-HR (semi matt finish) and RAL 841-GL (gloss finish) will guarantee a reliable manufacture and control of RAL Colours. 11 PR ODUCT SELECTOR by application areas Area Suspension system solution Open spaces Axiom Canopy (C/KE/Circle/Curved) Axiom Transitions Bandraster Reception areas Axiom Transitions Axiom Profiles Silhouette 15 mm Microline 15 mm Interlude 15 mm Meeting rooms / Individual offices Prelude 24 mm Prelude 15 mm Circulation areas System Z Microline 15 mm Prelude Sixty2 Retail outlets / industrial manufacturing Prelude 35 XL2 Humid areas Prelude 24 Corrosive Resistant Healthcare environments Clean Room Grid PR ODUCT SELECTOR by edge detail compatibility Axiom Transitions/ Profiles Silhouette Interlude Microline 15 15 Prelude 15 Prelude 24 XL2 Prelude 24 TLX Prelude Sixty2 • • • Prelude Clean Room Corrosive Bandraster System Z 35XL2 Resistant Mineral Vector • MicroLook • MicroLook BE • Tegular • • • • Board • • • • SL2 • • • • Metal Axal Vector • • Metal MicroLook 8 • Metal MicroLook 16 • Metal Tegular 2 • • • Metal Tegular 8, 11F or 16 • • • • Metal Board • • • • • • • • • • • • • • • • • Metal • • • • • • 12 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie TECHNICAL ICONS Colour Pallet Peakform Accessories Perimeter Trim Corridor Specific Applications/ Healthcare Environments Designer Grid General Applications 13 HEALTH AND CL EANLINES S Did You Know... ? ■ There are 2 types of rooms: It’s all about Air Quality control: ■ The air penetrating the Clean Room can be filtered depending on the size of the undesired elements. - rooms with over-pressure, to avoid pollutants from entering (dust, bacteria,…) ■ Air can be recycled up to 60 times per hour for the total volume of the space. - rooms with negative pressure, to avoid various contaminants from escaping to the outside (viruses, bacteria, spores,…). ■ New air is also introduced to avoid a build up in the concentration of CO2 and maintain enough oxygen for the people working there. ■ Building materials used in such spaces shall not have a negative impact on the pursuance of cleanliness and should preferably contribute actively to a better ■ Operators in a clean room have to wear equipment such as a clean room suit, caps, gloves, shoe protectors and masks. CLEAN ROOM A clean room is a space or a series of spaces where the concentration of particles is controlled in order to minimise the introduction, generation, retention of particles inside, generally for a specific industrial or research objective, as well as in healthcare environments. Parameters such as temperature, humidity and relative pressure are also maintained at a precise level, as defined in ISO 14644-1. • Clean rooms are classified ISO 1 (cleanest) to ISO 9 depending on the number of particles measured. • The performance is tested to ISO 14644-1 which determines the particle cleanliness class. Although US Federal Standard 209E has been officially withdrawn, it is continuously used as a reference. The following table shows the equivalence between the 2 standards. Maximum Number of Particles in Air ISO Class (particles in each cubic metre equal to or greater than the specified size) US Federal Standard 209E Particle size > 0.1µm > 0.2 µm > 0.3 µm ISO Class 1 10 2 > 0.5 µm 10 4 > 1 µm > 5 µm ISO Class 2 100 24 ISO Class 3 1 000 237 102 35 8 Class 1 ISO Class 4 10 000 2 370 1 020 352 83 Class 10 ISO Class 5 100 000 23 700 10 200 3 520 832 29 Class 100 ISO Class 6 1 000 000 237 000 102 000 35 200 8 320 293 Class 1 000 ISO Class 7 352 000 83 200 2 930 Class 10 000 ISO Class 8 3 520 000 832 000 29 300 Class 100 000 ISO Class 9 35 200 000 8 320 000 293 000 Class 1 000 000 - HEALTHCARE PREMISE In healthcare premises, it is of critical importance to avoid hospital acquired infections. According to the level of risk, the necessary clean room performance will vary, generally between ISO 5 and ISO 8. All products below: • can be used in ISO 5 environments and are certified against ISO 14644-1; • inhibit growth of bacteria, moulds and yeasts tested against norms NF S 90-351, France, and JIS Z2801, Japan. Some examples of spaces and system solutions: TYPE OF SPACE CONSTRAINTS SYSTEM SOLUTION* LEVEL OF PERFORMANCE Operating Theatre Fully air-tight Flush surface finish Anti-microbial Metal Bioguard Plain Clip-In with appropriate silicone or mastic joint ISO 3 High pressure water cleanable MRI Non-magnetic CLEAN ROOM grid with plastic hold-down clips & Clean Room FL ISO 5 Anti-static Anti-microbial CLEAN ROOM grid with plastic hold-down clips & Bioguard Acoustic ISO 5 Bioguard treatment Anti-microbial Good air-tightness Good acoustical environment Clean Room grid with plastic hold-down clips Bioguard Acoustic or Metal Bioguard Extra Microperforated Rg 0701 with Premium B15 ISO 5 Washable 0.65 Ȋw sound absorption Intensive Care Recovery Room Maternity Laboratory Pharmacy * Subject to local regulations. Please check with your Armstrong Technical Sales team. 14 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Did You Know... ? BIOGUARD products have been especially designed for the healthcare sector. System solutions for the pharmaceutical, food and manufacturing industry can be found in our brochure “Solutions for Clean Room Environments”. The BIOGUARD paint treatment has additional active components which reduce the colony size of virulent strains of bacteria, moulds and yeasts. BIOGUARD products achieve ISO 5 to ISO 3 in accordance with ISO 14644-1. BIOGUARD paint has enhanced resistance to disinfectants. Grid and tiles for Clean Room environments GRID MINERAL METAL Clean Room Grid Bioguard Plain Bioguard Acoustic Clean Room FL Metal Bioguard Extra Microperforated Rg 0701 with Premium B15 Metal Bioguard Plain Classification NF S 90-351 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2, 3 & 4 Particle cleanliness class ISO 4 ISO 5 ISO 5 ISO 5 ISO 5 ISO 3 Material Aluminium Mineral Mineral Mineral Steel with mineral acoustic infill Steel Surface PVC Bioguard paint Glass veil with Bioguard paint Polyester film EXTRA MICROPERFORATED Rg 0701 with Bioguard polyester powder paint PLAIN with Bioguard polyester powder paint Resistance to disinfectants* Quaternary Ammonium, Hydrogen Peroxide, Chlorine * * Not tested 15 Quaternary Ammonium, Hydrogen Peroxide, Chlorine FIR E P ER FOR MANCES REACTION TO FIRE The harmonisation of technical standards within Europe, and the integration of EN13964 (Suspended ceilings – requirements and test methods) into national legislation, means that there is now one series of harmonised European test methods and classifications for the reaction to fire of suspended ceilings. Products Directive and national building regulation requirements for internal linings. These new reaction to fire classifications, or ‘Euroclasses’, are defined in EN13501-1:2007. The ‘Euroclasses’ rate from A1 through to F, with A1 being the best reaction to fire performance and F the worst. The ‘Euroclasses’ have replaced the old national fire reaction ratings for showing the performance of ceilings in order to meet the Construction As reaction to fire is one of the essential safety requirements identified for suspended ceilings, the Euroclass classification is one of the mandatory elements on the CE mark for suspended ceiling tiles and grids. Each member state then sets the performance level required for different areas and building types within their own building regulations. Depending upon the reaction to fire test(s) conducted, the rating may include an additional classifications for smoke production and flaming droplets. Smoke and flaming droplets are regulated in some European countries. Smoke production is rated from s1 (the least smoke produced) to s3 (no limit to amount of smoke produced). Flaming droplets is rated from d0 (no flaming droplets) to d2 (no limit to flaming droplets). STRUCTURAL FIRE PROTECTION Throughout Europe, there is a requirement for a building’s structure to be protected from fire. This is primarily for the structure to remain stable during a fire to allow the occupants to escape and also to enable fire fighters to work without threat of the building’s collapse. The duration of the required protection will usually depend upon the height of, and location within, the building (i.e. typical floor, basement, roof construction etc), whether there is any active methods of fire protection (sprinklers etc) and the type of construction to be protected (steel beams, timber or mezzanine floors etc). A fire protecting suspended ceiling system is one of several important methods of providing the fire protection which fire degradable elements of the structure require. Ceilings can be used to enable a floor construction to meet the duration of protection required by the building regulations that it could not necessarily provide on its own. and comparison to similar tested products, provided this is supported by an assessment report from a recognised fire expert and should be provided with the base test report that details how the product should be installed to achieve the assessed performance. The location and type of various service elements such as lighting fittings, smoke detectors etc, are infinite and the designer and installer must satisfy themselves that they can be integrated without reducing the tested performance of the ceiling system. This will usually require a test report from the fitting manufacturer or an assessment issued by the fire authorities. Without these documents the designer or installer may assume an everlasting responsibility for the fire safety of the building and occupants. The complete construction and assembly of the test installation is important to the success of the test, and Armstrong test many ceiling tiles for their structural fire performance, but always on Armstrong grid. There are many other details of the test construction that must be understood and adhered to. These include: There are many national test methods for establishing the structural fire protection performance of a suspended ceiling system, as well as several European norms which are acceptable in most European countries. The performance achieved during testing will be classified in terms of the duration of protection given, typically this in accordance with EN13501-2:2007 for European tests. However, there is not yet one single European test method which is acceptable to all member states. • whether ceiling tile hold-down clips were used. Untested products may be assessed by reference to the product attributes These details must be included in the installation if the tested performance is • main runner and hanger centres • the type of top fixings and how the hangers are attached to them • the minimum depth of the ceiling void • what % of the floor design load is tested 16 to be realised and they should be taken into account when writing specifications for ceilings intended to provide structural fire protection. In the UK the fire performance of floor structures protected by Armstrong ceiling tile and grid systems is given in the fire assessment document 173816. This document is based on a large number of fire tests conducted on various Armstrong ceiling tile and grid types. It provides an assessment of the performances attainable when various Armstrong tile and grid systems are installed in accordance with the appropriate base fire test and the permitted installation variations from that base test. The tables opposite give a summary of the performances achievable as stated in the assessment document and are correct at the time of going to print. As products may be modified or retested it is essential that their validity is always checked prior to installation. Therefore, the current version of the assessment document 173816 and the relevant base test report should always be consulted prior to the installation of a floor construction to be protected by an Armstrong ceiling system. A full document is always required and must be read and any limitations understood. Abridged versions must be regarded as undesirable as they will not show the full test details and construction. All Armstrong classification documents are freely available on request from the Armstrong Technical Sales team. www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Building Regulation performance table – internal linings Building Regulations area (non-residential) Euroclass Old classification Circulation areas A1 A2-s3, d2 B-s3, d2 Non-combustible Limited Combustibility Class 0 Class 1 Class 2 Class 3 Class 4 Other Rooms (> 30 m2) C-s3, d2 Small Rooms (≤ 30 m 2) D-s3, d2 E-d2, F (Product cannot be used) Assessed Performance Under Structural Steel Beams - Base Test Report: 134086 (70995 for Clip-In) Board Tegular MicroLook Tegular 2 Clip-In 3mm Comments 90 minutes 60 minutes 30 minutes 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes n/a 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes 60 minutes n/a 60 minutes 60 minutes 60 minutes n/a 60 minutes 60 minutes 60 minutes 30 minutes 30 minutes 30 minutes 30 minutes n/a 60 minutes n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 60 minutes n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Includes 500 x 500 and 1200 x 300 MicroLook ULTIMA 60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad Metal Microperforated Rd 1522 + Premium B15 or PAD 60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad Metal Extra Microperforated Rg 0701 + Premium B15 or PAD 60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad Metal Plain + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad Metal Standard Perforated Rg 2516 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad Metal Microperforated Rd 1522 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad Metal Extra MicroperforatedRg 0701 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad Ultima Ultima dB Ultima OP Perla Bioguard Acoustic / Bioguard Plain Dune dB Dune Supreme Fine Fissured Plain Cirrus Mezzanine DL 100 Metal Plain + Premium B15 or PAD Metal Standard Perforated Rg 2516 + Premium B15 or PAD Includes Colortone Black Does NOT include GRAPHIS Does NOT include any CIRRUS Design tiles 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad Assessed Performance Under Timber Floors - Base Test Report: 167751 Ultima Ultima dB Dune dB Dune Supreme Mezzanine DL 100 Fine Fissured Ultima / Ultima dB Perla Sierra Bioguard Acoustic / Bioguard Plain Fine Fissured Plain Cirrus Board Tegular MicroLook Tegular 2 Clip-In 3mm 60 minutes 60 minutes 60 minutes 30 minutes n/a n/a 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 60 minutes 60 minutes 60 minutes 30 minutes n/a n/a 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 60 minutes 60 minutes 60 minutes n/a n/a n/a 30 minutes n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Comments Main runners at 600mm centres only Includes Colortone Black Does NOT include GRAPHIS Does NOT include any CIRRUS Design tiles Assessed Performance Under Mezzanine Floors - Base Test Report: 120559 Ultima / Ultima dB Ultima dB Dune dB Dune Supreme Mezzanine DL 100 Perla Sierra Bioguard Acoustic / Bioguard Plain Fine Fissured Plain Cirrus Board Tegular MicroLook Tegular 2 Clip-In 3mm Comments 60 minutes 60 minutes 60 minutes 30 minutes 60 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 60 minutes 60 minutes 60 minutes 30 minutes n/a 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Includes Colortone Black Does NOT include GRAPHIS Does NOT include any CIRRUS Design tiles *AFTBF = an aluminium foil, black tissue faced acoustic pad 17 INSTALL ATION & MAINTENANCE SAFETY Armstrong’s commitment on safety concerns each and every step of our business: • in our plants & offices, we have implemented rigorous safety policies and procedures to help minimise risk • for our products, for which we ensure compliance with appropriate European and local safety regulations. • on the jobsite, safety is crucial for our partners: Armstrong therefore recommends the handling, installation & maintenance of our solutions in accordance with the European standards and /or local regulations, for the safety of the installers & of the end users. GENERAL ADVICE Installation of suspended ceiling systems should be carried out in accordance with Armstrong's current manufacturer's recommendations. For grid systems there are some specific points that should be considered: - The appropriate type of Cross Tee for the ceiling tile edge detail must be considered. - The grid systems should be installed in such a way that the loadbearing performance of the grid is not exceeded. - 'Dynamic' service fittings should be independently supported so not to transfer vibration into the suspension system. - Armstrong recommend the use of the 'ladder formation' and all our loading data is based on the 'ladder formation'. Using the 'Hformation' will give greater deflection for a given load. Ladder formation Yes 18 H formation No www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie INSTAL L ATION & MAINTENANCE 1 2 2 B A 600 1000 3 Min 100 mm M A 800 300 mm B 1. Planning grid layout 4 3. Installation of perimeter trims 2. Mark the perimeter trim lines 6 5 Max 600 mm 1200 mm B (Main Runner) 1200 mm 1200 mm B (Main Runner) 4. Mark hanger positions 7 5. Installation of hangers 6. Positioning Main Runner slots 9 8 7. Installation of Main Runners 10 8. Cross Tees installation right to right 11 9. Cutting Cross Tees 12 A /B A /B 10. Installation of tiles 11. Measure and cut perimeter tiles 12. Re-tegulating Tegular or MicroLook tiles POST INSTALLATION After the installation of a suspended ceiling system it is important to ensure that it is properly maintained and that any additional works are not detrimental to the performance of the ceiling installation. Maintenance operations must only be undertaken after the technical impact on the ceiling system has been completely evaluated. For example, hangers should not be removed, adapted or bent without fully understanding the consequences and taking any appropriate mitigating actions. Armstrong suspension systems do not need any more maintenance than normal painted metal surfaces. However, if cleaning is required dust and superficial dirt can easily be removed with a soft brush or a vacuum cleaner with a brush attachment. For more stubborn marks a lightly dampened cloth or sponge can be used, although never use abrasive products. Some companies specialise in chemical cleaning solutions. These should only be undertaken after a test on a small hidden area of grid proves acceptable. Most Armstrong suspension systems can be redecorated, however, consideration should be given to the effect on the fire reaction performance of the grid. Ceiling tiles should be removed, however, the grid can usually be painted in situ. If a firm of professional decorators is used, assurances should be sought that the necessary performances will be maintained. It should be noted that any repainting would invalidate Armstrong's warranty for the product. For a copy of Armstrong's Suspension Systems Calculation Guide, please contact Armstrong Technical Sales. 19 LOAD CAPACIT Y MATR IX Loading is an important property of suspended ceiling grid systems both for the mechanical safety of the suspended ceiling and its visual appearance. In the EEA, table 6 of the suspended ceiling product standard, EN 13964:2004+A1:2006, defines 3 classes of deflection, the best being Class 1 which is L/500 (but no greater than 4mm). Class Maximun deflection in mmA 1 2 3 LB / 500 and not greater than 4,0 LB / 300 No limit A The maximun deflection is the accumulative value of the deflection of the substructure component and the deflection of the membrane component. B L is the span in mm between the suspension components or the suspension points. The test method on which the European calculations of loadbearing capacity are based upon is also defined in EN 13964, and considers the influence of both deflection and bending moment. The individual product pages in the second half of this brochure include a table giving the maximum uniform distributed load, based on different hanger centres, in accordance with Class 1 deflection, as defined in EN 13964:2004 + A1:2006. For markets outside of the EEA different deflection limits are sometimes required. The tables on this page show the maximum uniform distributed load for the deflection limits shown, but taking into account deflection only. These values are calculated based upon load values determined from laboratory tests in accordance with the EN 13964 test method. For longer spans, some of the criteria shown on this page may give quite large deflection values. Armstrong recommends a maximum of 4mm deflection between points of suspension for all grid components, irrespective of span, for aesthetic reasons. Therefore the numbers in the tables on this page are the maximum loads permitted to meet the give a deflection criteria (such as L/400) but up to a maximum value of 4mm. System Load Summary (1200 x 1200 layout) - Max Load kg/m2 - Deflection factor only System Main Runner Primary Cross Tee Secondary Cross Tee Prelude 24 XL2 314032 A 313051 B Prelude 24 TLX 314032 A Prelude 15 XL2 304033 A Prelude 15 TL Microline Silhouette 15 XL Interlude 15 XL2 2 L/500 L/400 L/360 L/300 L/250 312021 A 13,3 16,8 18,8 22,7 22,7 133031 132031 13,3 16,8 18,7 22,7 22,7 303033 B 302033 B 13,1 16,5 18,5 22,3 22,3 304033 A 103033 A 102033 A 13,1 16,5 18,5 22,3 22,3 CS 25 42 92 WR CS 25 30 42 WR CS 25 20 42 WR 12 15 17 20.5 20.5 804042 G 803042 G 802042 G 11,4 14,4 16,1 19,5 19,5 614042 G 613042 G 612042 G 14,5 18,3 20,4 24,7 24,7 Prelude 35 XL2 224042 Prelude 24 Corrosive 284042 Resistant - TLX 243042 242042 13,9 17,7 19,8 24 24 143032 142032 13,3 16,8 18,7 22,7 22,7 Clean Room 24 EA793044 EA792044 12,8 16,3 18,2 22,1 22,1 EA794044 1200mm spacing 600mm 1 1200mm Cross Tees MR 20 MR www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Load Summary (1200x1800 layout) - Max Load kg/m2 - Deflection factor only System Prelude 24 XL2 (1800 span) Prelude 24 TLX (1800 span) Main Runner Primary Cross Tee Secondary Cross Tee L/500 L/400 L/360 L/300 L/250 314032 A 313431 A 312021 A 6,5 7,3 7,3 7,3 7,3 314032 A 133432 132031 6,5 7,3 7,3 7,3 7,3 1200mm spacing 600mm 1800mm Cross Tees MR MR System Load Summary (1800x1800 layout) - Max Load kg/m2 - Deflection factor only System Main Runner Primary Cross Tee Secondary Cross Tee L/500 L/400 L/360 L/300 L/250 Prelude Sixty2 24 - XL2 404093 G 313431 A Prelude Sixty2 24 - TLX 404093 G 133432 312021 A 6,5 7,3 7,3 7,3 7,3 132031 6,5 7,3 7,3 7,3 7,3 1800mm spacing 600mm 1800mm Cross Tees MR 21 MR 1 Design Options AXIOM TRANSITIONS The 5 sections are designed to provide a flush transition between plaster margin and mineral, metal or wooden suspended ceilings. Axiom Transitions Item Nr. Description Dimensions Content / Carton length (mm) height (mm) 50 Weight / Carton pcs lm kg Cartons / Pallet T 3208 G (1) Axiom Transitions for Tegular/MicroLook 3000 50 10 30,00 11,80 36 T 3219 G (1) Axiom Transitions channel 3000 50 10 30,00 17,10 36 T 3215 G (1) Axiom Transitions angle 3000 50 10 30,00 15,00 36 T 3210 G (1) Axiom Transitions for Vector tiles 3000 50 10 30,00 11,80 36 T 3225 G (1) Axiom Transitions plasterboard perimeter trim 3000 50 10 30,00 11,30 36 8 25 15 50 15 25 15 19 50 15 25 15 15 50 11 25 15 35 15 25 15 Accessories for Axiom Transitions Item Nr. 79 mm Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg A 321 G Axiom Transitions suspension clip – straight 79 100 2,10 A 322 G Axiom Transitions suspension clip – angled 62 100 2,10 A 340 G Axiom universal corner clip - 100 2,10 A 338 G Axiom universal splice plate - 100 2,10 A 339 G Axiom universal T bar connector clip - 100 2,10 A 344 G Axiom universal hanging clip - 100 2,10 62 mm (1) Also available in colour RAL 9010 (WR). Note: As Axiom is an aluminium extrusion it should not be used in ceiling assemblies where structural fire protection is required. All measurements in millimetres. All sizes are nominal. 22 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing A 321 G A 322 G A 340 G A 338 G A 339 G 23 Design Options AXIOM TRANSITIONS Design Options AXIOM PROFILES Available in 5 heights with a plasterboard trim section, Axiom Profiles are compatible with 24 mm and 15 mm grid systems including designer grid. Axiom Profiles Item Nr. Description Dimensions length (mm) Content / Carton height (mm) pcs Weight / Carton lm Cartons / Pallet kg 52 42 06 G (1) Axiom Profiles 50 mm 3000 50 5 15,00 7,80 60 54 42 06 G (1) Axiom Profiles 100 mm 3000 100 5 15,00 11,20 36 56 42 06 G (1) Axiom Profiles 150 mm 3000 150 5 15,00 14,70 30 58 42 06 G (1) Axiom Profiles 200 mm 3000 200 5 15,00 17,80 24 55 14 11 G (1) Axiom Vector Profiles 112 mm 3000 112 5 15,00 12,20 15 18,5 10 30,00 5,80 36 19 19 112 150 100 19 200 19 50 T 3213 H (1) Profile plasterboard trim 3000 Accessories for Axiom Profiles Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg A 334 G (1) Axiom Profiles corner post 50 mm 50 2 0,30 A 335 G (1) Axiom Profiles corner post 100 mm 100 2 0,50 A 336 G (1) Axiom Profiles corner post 150 mm 150 2 0,70 A 337 G (1) Axiom Profiles corner post 200 mm 200 2 0,90 A 345 G (1) Axiom Vector corner post 112 mm 112 2 0,60 A 340 G Axiom universal corner clip 100 2,10 A 338 G Axiom universal splice plate 100 2,10 A 339 G Axiom universal T bar connector clip 100 2,10 A 344 G Axiom universal hanging clip 100 2,10 (1) Also available in colour RAL 9010 (WR) 24 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing A 344 G A 344 G A 334 G A 335 G A 336 G A 337 G A 345 G A 340 G A 338 G A 339 G ≤ 200 A 100 (1) Also available in colour RAL 9010 (WR) 25 Design Options AXIOM PROFILES Design Options AXIOM C CANOPY Axiom C Canopy is a perimeter trim system designed to create “ceiling clouds” in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Axiom C Canopy will define and individualise any space. Axiom C Canopy Components Item Nr. 55 14 11 G Description Axiom Vector MicroLook Tegular Profile 112 mm 112 mm C 3000 G Primary C channel A WDN 21 H T bar hanger Vector Tegular / MicroLook Cut to size Main Runner 600 mm XL2 Cross Tees 3.0m A 345 G Axiom Vector MicroLook Tegular Profile corner post A 348 G Channel bracket CA 97 G Clamp for C channel A 347 G 24 mm XL2 connector clip A 346 G 15 mm XL2 connector clip A 339 H Axiom universal T bar connector clip for cut tees with screws 2.4m 1.8m 1.2m 10 tiles 8 tiles 6 tiles 1.8m 15 tiles 12 tiles 9 tiles 2.4m 20 tiles 16 tiles 3.0m 25 tiles 1.2m 4 tiles Axiom C Canopy Kits* Module Grid system 15 mm XL2 Grid system 24 mm XL2 Item Nr. Item Nr. ! R E C O M M E N D AT I O N S Axiom C Canopy should always be installed in accordance with all applicable building codes and regulations. 1200 x 1200 mm AX 22 G15 AX 22 G24 1800 x 1200 mm AX 32 G15 AX 32 G24 1800 x 1800 mm AX 33 G15 AX 33 G24 2400 x 1200 mm AX 42 G15 AX 42 G24 2400 x 1800 mm AX 43 G15 AX 43 G24 2400 x 2400 mm AX 44 G15 AX 44 G24 • Read the installation instructions included in the carton carefully before starting the installation. 3000 x 1200 mm AX 52 G15 AX 52 G24 • Make sure the installation is clean and safe. 3000 x 1800 mm AX 53 G15 AX 53 G24 3000 x 2400 mm AX 54 G15 AX 54 G24 3000 x 3000 mm AX 55 G15 AX 55 G24 *Ceiling tiles are NOT included in the kit. • Axiom C Canopy should only be installed on a horizontal plane. They are not approved for exterior installations. • Axiom C Canopy should always be installed by a minimum of 2 people. • Any additional weights (such as luminaires...) must be independently suspended from the soffit. • Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing. All measurements in millimetres. All sizes are nominal. 26 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing The 1800 mm x 3000 mm module is used as an example only. An installation instruction guide is available. Please contact Armstrong Technical Sales for further details. 4 Universal T bar connector clips 8 XL2 connector clips 6 Aircraft cables & Gripple connectors 6 Universal T bar connector clips 4 Corner posts 4 Axiom profiles cut to size 3 C channels cut to size 6 Channel brackets 6 T bar hangers 12 Cross Tees 600 mm XL2 (24 mm or 15 mm) 2 Main Runners cut to size (24 mm or 15 mm) OPTION 1 Aircraft cable & Gripple connectors OPTION 2 Quick hanger* OPTION 3 6 mm Threaded rod* 27 * not included in the kit Design Options AXIOM C CANOPY Design Options AXIOM KE CANOPY Axiom KE Canopy is an aesthetic perimeter trim system designed to create “ceiling clouds” in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Axiom KE Canopy is a quick refurbishment solution, ideal for acoustically challenged or open plenum spaces. Axiom KE Canopy Components Item Nr. Description CS 57 42 06 G Axiom KE Profile C 3000 G Primary C channel A WDN 21 H T bar hanger Tegular / MicroLook 106 mm 135 mm Vector Cut to size Main Runner 600mm XL2 Cross Tees 106 mm CS 57 G Mitre corner piece A 361 G Mitre corner splice connector 135 mm 3.0m 2.4m 1.8m A 348 G Channel bracket 1.2m 10 tiles 8 tiles 6 tiles CA 97 G Clamp for C channel 1.8m 15 tiles 12 tiles 9 tiles A 347 G 24 mm XL2 connector clip A 346 G 15 mm XL2 connector clip 2.4m 20 tiles 16 tiles A 339 H Axiom universal T bar connector clip for cut tees with screws 3.0m 25 tiles A 338 G 1.2m 4 tiles Axiom universal splice plate Axiom KE Canopy Kits* Module Grid system 15 mm XL2 Item Nr. ! Grid system 24 mm XL2 Item Nr. RECOMMENDATIONS Axiom KE Canopies should always be installed in accordance with all applicable building codes and regulations. 1200 x 1200 mm CS AK 22 G15 CS AK 22 G24 1800 x 1200 mm CS AK 32 G15 CS AK 32 G24 1800 x 1800 mm CS AK 33 G15 CS AK 33 G24 2400 x 1200 mm CS AK 42 G15 CS AK 42 G24 2400 x 1800 mm CS AK 43 G15 CS AK 43 G24 2400 x 2400 mm CS AK 44 G15 CS AK 44 G24 3000 x 1200 mm CS AK 52 G15 CS AK 52 G24 • Read the installation instructions included in the carton carefully before starting the installation. 3000 x 1800 mm CS AK 53 G15 CS AK 53 G24 • Make sure the installation is clean and safe. 3000 x 2400 mm CS AK 54 G15 CS AK 54 G24 3000 x 3000 mm CS AK 55 G15 CS AK 55 G24 • Any additional weights (such as luminaires...) must be independently suspended from the soffit. • Axiom KE Canopies should only be installed on a horizontal plane. They are not approved for exterior installations. • Axiom KE Canopies should always be installed by a minimum of 2 people. • Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing. *Ceiling tiles are NOT included in the kit. All measurements in millimetres. All sizes are nominal. 28 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing The 1800 mm x 3000 mm module is used as an example only. An installation instruction guide is available. Please contact Armstrong Technical Sales for further details. 4 Universal T bar connector clips 8 XL2 connector clips 6 Aircraft cables & Gripple connectors 6 Universal T bar connector clips 8 Corner splice connectors 16 Axiom universal splice plates 6 Channel brackets 4 Mitre Corners 6 T bar hangers 12 Cross Tees 600 mm XL2 (24 mm or 15 mm) 4 Axiom profiles cut to size 2 Main Runners cut to size (24 mm or 15 mm) 3 C channels cut to size OPTION 1 Aircraft cable & Gripple connectors OPTION 2 Quick hanger* OPTION 3 6 mm Threaded rod* 29 * not included in the kit Design Options AXIOM KE CANOPY Design Options AXIOM CIRCLE & CURVED The Axiom Circle & Curved Canopies are an aesthetic perimeter trim system designed to create “ceiling clouds” in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Curved and Circle Canopies allow specifiers to play with different planes and levels as well as conceal service elements. Axiom Circle & Curves Components Item Nr. Description 62 42 06 G Axiom Circle and Curved Profile C3000 G Primary C Channel 30 40 33 A Prelude Peakform Main Runner T15 or 31 40 32 A Prelude Peakform Main Runner T24 30 20 33 B Prelude XL2 Cross Tee 600 mm T15 or 31 20 21 A Prelude XL2 Cross Tee 600 mm T24 AWDN 21 H T bar hanger A 361 G Splice connector A 339 H Axiom universal T bar connector clip for cut tees with screws A 156 G Perimeter fill-in for 15 mm grid A 246 G Perimeter fill-in for 24 mm grid A 348 G Channel bracket CA 97 G Clamp for C Channel Tegular / MicroLook 1.8m Ø Canopy 1.8m x 2.4m Canopy 1.8m x 3m Canopy 2.4m Ø Canopy 2.4m x 2.4m Canopy 2.4m x 3m Canopy 3m x 3m Canopy Axiom Circle & Curved Kits* Module Grid system 15 mm XL2 Item Nr. Grid system 24 mm XL2 Item Nr. Circle 1800 CS ACI 33 G15 CS ACI 33 G24 Circle 2400 CS ACI 44 G15 CS ACI 44 G24 Curved 2400 x 1800 CS ACU 43 G15 CS ACU 43 G24 Curved 2400 x 2400 CS ACU 44 G15 CS ACU 44 G24 Curved 3000 x 1800 CS ACU 53 G15 CS ACU 53 G24 Curved 3000 x 2400 CS ACU 54 G15 CS ACU 54 G24 Curved 3000 x 3000 CS ACU 55 G15 CS ACU 55 G24 *Ceiling tiles are NOT included in the kit. ! RECOMMENDATIONS Axiom Circle & Curved Canopies should always be installed in accordance with all applicable building codes and regulations. • Axiom Circle & Curved Canopies should only be installed on a horizontal plane. They are not approved for exterior installations. • Axiom Circle & Curved Canopies should always be installed by a minimum of 2 people. • Read the installation instructions included in the carton carefully before starting the installation. • Make sure the installation is clean and safe. • Any additional weights (such as luminaires...) must be independently suspended from the soffit. • Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing. All measurements in millimetres. All sizes are nominal. 30 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing The 1.8 x 2.4 m module is used as an example only. An installation instruction guide is available. Please contact Armstrong Technical Sales for further details. 10 Universal T bar connector clips 6 Aircraft cables & Gripple connectors 6 Universal T bar connector clips Splice connector 6 Channel brackets Axiom Profiles cut to size 6 T bar hangers 2 Main Runners cut to size (24 mm or 15 mm) 12 Cross Tees 600 mm XL2 (24 mm or 15 mm) 3 C Channels cut to size OPTION 1 Aircraft cable & Gripple connectors OPTION 2 Quick hanger* OPTION 3 6 mm Threaded rod* 31 * not included in the kit Design Options AXIOM CIRCLE & CURVED Design Options SILHOUETTE 15 XL 2 Exposed 15 mm grid system (nominal). Silhouette 15 XL2 is a suspension system designed to create a crisp, clean look in conjunction with MicroLook tiles to provide an enhanced aesthetic. Main Runners Silhouette 15 (by-pass connection) Item Nr. Dimensions Content / Carton length (mm) height (mm) pcs lm Weight / Carton Cartons / Pallet kg with 6 mm reveal 80 40 42 G(1) 80 39 43 G(1) 80 44 42 G(1) 3600 3125 2700 44 44 44 20 20 20 72,00 62,50 54,00 24,50 25,40 18,40 36 25 30 with 3 mm reveal 81 40 42 WRG(2) 3600 44 20 72,00 24,50 36 1200 1250 1350 1000 44 44 44 44 60 60 30 60 72,00 75,00 40,50 60,00 24,50 23,80 13,80 20,40 35 35 50 24 600 625 675 500 300 44 44 44 44 44 60 30 60 60 120 36,00 37,50 40,50 30,00 36,00 12,70 16,00 14,30 10,60 34,00 70 70 70 70 70 1200 44 60 72,00 24,50 35 600 44 60 36,00 12,70 70 Peakform Cross Tees Silhouette 15 XL2 (stab system) with 6 mm reveal 80 30 42 G(1) 80 31 43 G(1) 80 33 42 G(1) 80 32 42 G(1) 80 20 42 G(1) 80 21 43 G(1) 80 23 42 G(1) 80 22 42 G(1) 80 24 42 G(1) with 3 mm reveal 81 30 42 WRG (2) 81 20 42 WRG (2) Section Drawings Main Runners Silhouette 15 Length 3600 3500 3125 2700 300 250 312,5 337,5 600 500 625 675 3 x 600 4 x 500 2 x 625 675 600 500 625 675 300 250 312,5 337,5 Cross Tee Silhouette 15 XL2 Length 1350 1250 1200 1000 675 625 600 500 675 625 600 500 Cross Tee Silhouette 15 XL2 675 / 625 / 600 / 500 / 300 All products standard in Global White unless indicated by index (2). Other standard colours available for item numbers with index (1). See details below. (1) Silhouette with 6 mm reveal is available in white, black (BK) or white with black reveal (BI). (2) WR = White RAL 9010 (WR) All measurements in millimetres. All sizes are nominal. 32 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Silhouette 15 XL2 - Pre-mitred intersections - Choice of either 6 or 3 mm reveal dimension - Silhouette 15 XL2 with 3 mm reveal is supplied as standard in RAL 9010 white to compliment Armstrong metal tiles Perimeter Solutions Section Cross Tee trimmed to wall angle View of mitred intersection from beneath Section 8 Cross Tee trimmed to shadowline T 1508 HB at perimeter 24 4 Axiom Profiles (50, 100, 112, 150 and 200 mm heights available) MCC4 G Mitre closure clip for 6 mm reveal Silhouette 15 XL2 system A 339 G Axiom universal T bar connector clip Grid Load Capacity Silhouette 15 XL2 System The following table gives the maximum permitted hanger distance (mm) along the Silhouette Main Runner (80 40 42 G) for the tile weights and Main Runner spacings noted. Hanger spacing Tile weight Main Runner spacing 1200 mm 1200 mm XL Cross Tee 80 30 42 G Main Runner spacing 600 mm 600 mm XL Cross Tee 80 20 42 G 2 2,5 kg/m2 1800 2100 3,0 kg/m 1700 2100 3,5 kg/m 1650 2050 4,0 kg/m 1600 2000 5,0 kg/m 1500 1900 5,5 kg/m 1450 1850 6,0 kg/m 1400 1800 7,0 kg/m 1300 1700 2 2 2 2 2 2 2 8,5 kg/m 2 1200 1600 10,5 kg/m 2 1100 1550 13,0 kg/m 950 1350 2 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. 2 Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 33 Design Options SILHOUETTE 15 XL 2 Design Options INTERLUDE 15 XL 2 Exposed 15 mm grid system (nominal). Interlude 15 XL2 is a suspension system developed for creative ceiling solutions, and quick and easy installation. Main Runner Interlude 15 (by-pass connection) Item Nr. Dimensions Content / Carton length (mm) height (mm) TZ 61 40 42 pcs 20 Weight / Carton Cartons / Pallet lm kg 72,00 23,60 36 3600 44 1200 44 60 72,00 30,30 42 Cross Tees unslotted 61 20 42 G 600 44 60 36,00 15,00 84 TZ 61 24 42 44 120 36,00 15,00 84 Cross Tees Interlude 15 XL2 (stab system) Cross Tees slotted 61 30 42 G 300 Section Drawings Main Runner Interlude 15 Length 3600 75 150 22 x 150 75 Cross Tee Interlude 15 XL2 Length 1200 600 600 Cross Tee Interlude 15 XL2 600 / 300 Product available as standard in Global White. All measurements in millimetres. All sizes are nominal. 34 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Interlude 15 XL2 - The stepped flange profile provides a unique double reveal visual - Unmitred intersections allow for Cross Tee installation at any Main Runner slot position Perimeter Solutions Interlude 15 XL2 can be easily field cut with snips in 3 simple steps: Section Cross Tee trimmed to wall angle 1. Cut down through bulb and web Section Cross Tee trimmed to shadowline T 1508 HB Partition Head Fixing 2. Snip flanges UPC AG Universal partition clip attaches to grid to provide fixing for partition head track: reversible for 15 mm or 24 mm grid systems 3. Bend away from bulb to snap off centre rail Grid Load Capacities Interlude 15 XL2 system The following table gives the maximum permitted hanger distance (mm) along the Interlude Main Runner (TZ 61 40 42) for the tile weights and Main Runner spacings noted. Hanger spacing Tile weight Main Runner spacing 1200 mm 1200 mm XL2 Cross Tee 61 30 42 G Main Runner spacing 600 mm 600 mm XL2 Cross Tee 61 20 42 G 2,5 kg/m 1950 2100 3,0 kg/m 1850 2100 3,5 kg/m 1750 2100 4,0 kg/m 1750 2100 5,0 kg/m 1650 2050 5,5 kg/m 1600 2000 6,0 kg/m 1550 1950 7,0 kg/m 1450 1850 2 2 2 2 2 2 2 2 8,5 kg/m 1350 1750 10,5 kg/m 1250 1650 13,0 kg/m 1100 1550 2 2 2 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 35 Design Options INTERLUDE 15 XL 2 Design Options MICROLINE 15 XL 2 Steel based grid with aluminium extrusion. The exposed sleeve provides a clean and crisp visual plus a practical fluted reveal for flexibility in partition fixing and relocation. Main Runners Microline 15 (bulb-to-bulb connection) Item Nr. Dimensions length (mm) CS 25 42 92 WR 600* Content / Carton height (mm) Weight / Carton pcs lm kg Cartons / Pallet 3000 49 20 60 23,00 32 3000 49 20 60 23,00 32 *slotted at 600 mm CS 25 42 92 WR 750* 49 mm *slotted at 750 mm 15 mm Cross Tees Microline 15 XL2 (stab system) Cross Tee slotted (at 600 mm) CS 25 30 42 WR 1200 44 60 72 26,00 72 CS 25 20 42 WR 600 44 60 36 13,00 144 CS 25 16 42 WR 750 44 60 45 16,00 144 44 mm 15 mm Cross Tees unslotted 44 mm 15 mm Section Drawings Main Runners Microline 15 3000 300 3 x 600 600 300 3000 375 2 x 750 750 375 Cross Tee Microline 15 XL2 1200 600 600 Cross Tee Microline 15 XL2 600/750 All dimensions are nominal (millimeters). Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section. 36 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Key Attributes • • • Physical Data Peakform Patented universal Main Runner and Cross Tee design increase strength and stability for improved performance and makes the grid easier to cut. The aluminium sleeves must be cut aside using a hand saw. For metal tiles with MicroLook 8mm edge Fluted reveal for M6 bolt • Material Chassis : Double web galvanised steel Sleeve : Extruded aluminium • Surface finish of the sleeve Baked polyester paint • Product Family Designer grids • Main Runner / Cross Tee Interface Pre-mitred intersections • End Detail Main Runner : bulb-to-bulb connection Cross Tees : staked-on stab clip • Colour Available in white (RAL9010) only Perimeter Options* Item Nr. Description Dimensions height (mm) Content / Carton Weight / Carton pcs lm kg 3050 20 61,00 18,10 200 100 - 5,00 40 T 2040 H WR A Perimeter channel RAL 9010 C 1803 H Perimeter wedge *Made up of steel C 1803 H 20 T 2040 H WR A Perimeter channel and perimeter wedge for cut modules Grid Load Capacities Microline XL2 System The following table gives the maximum permitted hanger distance (mm) along the Main Runner Hanger spacing Tile weight 1200 mm XL2 Cross Tee CS 25 30 42 600 mm XL2 Cross Tee CS 25 20 42 750 mm XL2 Cross Tee CS 25 16 42 2,5 kg/m 1950 2350 2200 3,0 kg/m 1950 2350 2200 3,5 kg/m 1850 2350 2200 4,0 kg/m 1750 2350 2200 4,5 kg/m 1650 2300 2050 5,0 kg/m 1600 2200 1950 5,5 kg/m 1500 2100 1900 6,0 kg/m 1450 2000 1800 6,5 kg/m 1400 1950 1750 7,0 kg/m 1350 1850 1700 8,0 kg/m 1250 1750 1600 9,0 kg/m 1200 1650 1500 10,0 kg/m 1150 1600 1400 14,0 kg/m - 1350 1200 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 37 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. Design Options MICROLINE 15 XL 2 General Applications PRELUDE 15 Exposed 15 mm grid system (nominal). Universal Main Runners Prelude 15 Peakform and Superlock Clip (bulb-to-bulb connection) Content / Carton Dimensions Item Nr. length (mm) height (mm) 30 40 33 A(1) 30 41 33 A(1) 30 43 33 A Weight / Carton pcs lm kg Cartons / Pallet 3600 3750 3375 43 43 43 20 20 20 72,00 75,00 67,50 22,50 23,20 22,50 32 32 32 1200 1250 1000 38 38 38 60 60 60 72,00 75,00 60,00 20,70 21,50 17,20 72 72 72 600 625 500 38 38 38 60 60 60 36,00 37,50 30,00 10,30 10,70 8,60 144 144 144 1800 1500 1350 1250 1200 38 38 38 38 38 30 30 60 60 60 54,00 45,00 81,00 75,00 72,00 15,20 14,00 26,00 21,60 20,70 20 20 72 72 72 Cross Tees unslotted 675 10 23 33 625 10 21 33 B(1) 600 10 20 33 A(1) 312,50 10 25 33 300 10 24 33 A 150 10 12 32 38 38 38 38 38 38 60 60 60 120 120 60 40,50 37,50 36,00 37,50 36,00 9,00 13,00 10,70 10,30 12,50 11,50 2,84 144 144 144 144 144 144 Cross Tees Prelude 15 XL2 (stab system, override) Cross Tees slotted 30 30 33 B(1) 30 31 33 A 30 32 33 (2) Cross Tees unslotted 30 20 33 B(1) 30 21 33 A 30 22 33 (2) Cross Tees Prelude 15 TL (hook system, butt cut) Cross Tees slotted 10 34 33 B 10 36 33 A 10 33 33 10 31 33 B (1) 10 30 33 A (1) Section Drawings Universal Main Runners Prelude 15 Length 3750 3600 3375 78,125 50 337,5 2 78,125 50 337,5 Cross Tee Prelude 15 TL Cross Tee Prelude 15 XL Length 1250 1200 1000 156,25 100 675 21 x 156,25 33 x 100 2 x 675 156,25 100 675 Length 2 x 312,5 2 x 300 2 x 250 312,5 300 250 Cross Tee Prelude 15 XL 1800 1500 1350 1250 1200 312,5 300 250 2 4 x 300 3 x 300 2 x 337,5 2 x 312,5 2 x 300 300 300 337,5 312,5 300 300 300 337,5 312,5 300 Cross Tee Prelude 15 TL 675 / 625 / 600 / 312,5 / 300 /150 625 / 600 / 500 All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below. (1)Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR). (2) Also available in RAL 9010 (WR). Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section. All measurements in millimetres. All sizes are nominal. 38 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing (module 600 x 600 mm) Standard lay-in installation of 15 mm exposed suspension system for MicroLook tiles and specific Board tiles. *reduce to 450 if heavy tile / overlays are used or heavy service fittings are located near the perimeter. Quantities required per 1m2 (no waste included) 6 Tile 1 Main Runner 2 Cross Tee 1200 mm 3 Cross Tee 600 mm 4 7 Hanger Universal retaining clip Main Runner centres Hanger centres 600 x 600 mm 2,78 pcs 1200 mm 1200 mm 0,84 lm 1,67 lm 0,84 lm 0,70 pcs 5,56 pcs 600 mm 1200 mm 1,67 lm - 1,67 lm 1,40 pcs 5,56 pcs 1200 x 600 mm 1,39 pcs 1200 mm 1200 mm 0,84 lm 1,67 lm 0,70 pcs 5,56 pcs 1200 mm 1,67 lm - 1,40 pcs 5,56 pcs 5 600 mm Perimeter trim approx. 0,70 lm/m 0,84 lm The chart is for general guidance only. 2 Grid Load Capacities Prelude 15 System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (30 40 33 A) for the tile weights and Main Runner spacings noted. Hanger spacing Main Runner spacing 1200 mm Main Runner spacing 600 mm Main Runner spacing 1200 mm Main Runner spacing 600 mm 1200 mm TL Cross Tee 600 mm TL Cross Tee 1200 mm XL2 Cross Tee 600 mm XL2 Cross Tee 10 30 33 A 10 20 33 A 30 30 33 B 30 20 33 B 2,5 kg/m 1900 2100 1900 2100 3,0 kg/m 1800 2100 1800 2100 3,5 kg/m 1750 2100 1750 2100 4,0 kg/m 1650 2050 1650 2050 5,0 kg/m 1550 2000 1550 2000 5,5 kg/m 1550 1950 1550 1950 6,0 kg/m 1500 1900 1500 1900 7,0 kg/m 1400 1800 1400 1800 8,5 kg/m 1300 1700 1300 1700 10,5 kg/m 1150 1600 1150 1600 13,0 kg/m 1050 1500 1050 1500 Tile weight 2 2 2 2 2 2 2 2 2 2 2 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. 39 General Applications PRELUDE 15 General Applications PRELUDE 24 XL2 Exposed 24 mm grid system (nominal). Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection) Item Nr. Dimensions length (mm) height (mm) 31 40 32 A(1) 31 41 33 B(1) 31 43 33 A 31 42 32 Content / Carton Weight / Carton pcs lm kg Cartons / Pallet 3600 3750 3375 3000 43 43 43 43 20 20 20 20 72,00 75,00 67,50 60,00 21,00 21,90 20,00 17,50 30 30 30 30 31 33 31 31 31 51 B(1) 31 30 51 B(1) 31 32 31(2) 1350 1250 1200 1000 38 38 38 38 60 60 60 60 81,00 75,00 72,00 60,00 17,20 18,90 18,20 15,10 20 72 72 42 31 34 31 A 1800 38 30 54,00 17,00 20 750 312,50 300 675 625 600 500 38 38 38 30 30 30 30 60 60 60 60 60 60 60 45,00 18,75 18,00 40,50 37,50 36,00 30,00 14,70 4,60 4,60 7,70 8,60 8,20 6,80 72 144 144 144 144 144 84 Cross Tees Prelude 24 XL2 (stab system, override) Cross Tees slotted Cross Tees unslotted 31 16 32 31 25 32 31 24 32 31 23 21 31 21 23 A(1) 31 20 21 A(1) 31 22 21(2) Section Drawings Universal Main Runners Prelude 24 Length 3750 3600 3375 3000 78,125 50 337,5 50 156,25 100 675 100 21 x 156,25 33 x 100 2 x 675 27 x 100 156,25 100 675 100 78,125 50 337,5 50 Cross Tee Prelude 24 XL2 Length 1800 1350 1250 1200 1000 300 337,5 312,5 300 250 4 x 300 2 x 337,5 2 x 312,5 2 x 300 2 x 250 300 337,5 312,5 300 250 Cross Tee Prelude 24 XL2 750 / 675 / 625 / 600 / 500 / 312,50 / 300 All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below. (1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR). (2) Also available in RAL 9010 (WR). Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section. All measurements in millimetres. All sizes are nominal. 40 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing (module 1200 x 600 mm) Standard lay-in installation of 24 mm exposed suspension system using Board, Tegular or Vector tiles. * * *reduce to 450 if heavy tile / overlays are used or heavy service fittings are located near the perimeter. Quantities required per 1m2 (no waste included) 6 Tile Main Runner centres 1200 mm 1200 x 600 mm 1,39 pcs 5 Main Runner 0,84 lm 1200 mm 2 Cross Tee 1200 mm 3 4 Cross Tee 600 mm 1,67 lm Hanger - 0,70 pcs 5,56 pcs 5,56 pcs 1,67 lm - 0,84 lm 1200 mm 1200 mm 0,84 lm 1,67 lm 0,84 lm 0,70 pcs 5,56 pcs 600 mm 1200 mm 1,67 lm - 1,67 lm 1,40 pcs 5,56 pcs The chart is for general guidance only. 2 Grid Load Capacities Prelude 24 XL2 System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (31 40 32 A) for the tile weights and Main Runner spacings noted. Hanger spacing Main Runner spacing 1800 mm 1800 mm XL2 Cross Tee 31 34 31 A Main Runner spacing 1200 mm Main Runner spacing 600 mm 1200 mm XL2 Cross Tee 60 mm XL2 Cross Tee 31 30 51 B 31 20 21 A 2,5 kg/m 1650 1900 2100 3,0 kg/m 1600 1800 2100 3,5 kg/m 1500 1750 2100 4,0 kg/m 1450 1700 2100 5,0 kg/m 1350 1600 2000 5,5 kg/m 1350 1550 1950 6,0 kg/m 1250 1500 1900 7,0 kg/m - 1450 1800 8,5 kg/m - 1300 1700 10,5 kg/m - 1200 1600 13,0 kg/m - 1050 1500 2 2 2 2 2 2 2 2 2 2 2 Universal retaining clip 1200 mm Perimeter trim approx. 0,70 lm/m Tile weight 7 1,40 pcs 600 mm 600 x 600 mm 2,78 pcs 1 Hangers centres 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 41 General Applications PRELUDE 24 XL2 General Applications PRELUDE 24 TLX Exposed 24 mm grid system (nominal). Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection) Item Nr. Dimensions Length (mm) 31 40 32 A(1) 31 41 33 B(1) 31 43 33 A 31 42 32 3600 3750 3375 3000 Content / Carton Height (mm) pcs lm 43 43 43 43 20 20 20 20 72,00 75,00 67,50 60,00 Weight / Carton Cartons / Pallet kg 21,00 21,90 20,00 17,50 30 30 30 30 Cross Tees Prelude 24 TLX (Hook system, butt cut) Cross Tees slotted 13 31 31(1) 13 30 31(1) (2) 13 60 31 1250 1200 600 38 38 38 60 60 60 75,00 72,00 36,00 18,90 18,10 9,10 72 72 144 13 10 32 13 34 32 13 50 32 13 36 32 13 33 31 13 32 32 1875 1800 1724 1500 1350 1000 38 38 38 38 38 38 30 30 30 30 60 60 56,20 54,00 51,70 45,00 81,00 60,00 17,80 17,10 16,50 14,50 19,60 19,40 20 20 20 20 20 72 Cross Tees unslotted 13 18 31 13 16 31 13 21 31 (1) 13 20 31(1) (2) 900 750 625 600 38 38 38 38 60 60 60 60 54,00 45,00 37,50 36,00 13,60 11,40 9,50 9,10 72 72 144 144 13 23 31 13 22 32 675 500 38 38 60 60 40,50 30,00 8,70 9,70 144 80 Section Drawings Universal Main Runners Prelude 24 Length 3750 3600 3375 3000 78,125 50 337,5 50 156,25 100 675 100 21 x 156,25 33 x 100 2 x 675 27 x 100 Cross Tee Prelude 24 TLX 156,25 100 675 100 78,125 50 337,5 50 Cross Tee Prelude 24 TLX Length 900 / 750 / 675 / 625 / 600 / 500 1875 1800 1724 1500 1350 1250 1200 1000 312,5 300 262 150 337,5 312,5 300 250 4 x 312,5 4 x 300 4 x 300 350 / 2 x 250 / 350 2 x 337,5 2 x 312,5 2 x 300 2 x 250 312,5 300 262 150 337,5 312,5 300 250 All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below. (1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE) and White RAL 9010 (WR). (2) Also available in Black (NG), Brown (MR) and Beige (BJ). Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section. 42 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing (module 1200 x 600 mm) Standard lay-in installation of 24 mm exposed suspension system using Board, Tegular or Vector edge tiles. * *reduce to 450 if heavy tile / overlays are used or heavy service fittings are located near the perimeter. Quantities required per 1m2 (no waste included) 6 1 Tile Main Runner centres Hanger centres 1200 x 600 mm 1,39 pcs 1200 mm 1200 mm 0,84 lm 600 mm 1200 mm 1,67 lm 600 x 600 mm 2,78 pcs 1200 mm 1200 mm 0,84 lm 600 mm 1200 mm 1,67 lm 5 Main Runner 2 Cross Tee 1200 mm 3 4 Cross Tee 600 mm 1,67 lm Hanger - 1,67 lm - 5,56 pcs 0,84 lm 1,40 pcs 5,56 pcs 0,84 lm 0,70 pcs 5,56 pcs 1,67 lm 1,40 pcs 5,56 pcs 2 The chart is for general guidance only. Grid Load Capacities The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (31 40 32 A) for the tile weights and Main Runner spacings noted. Hanger spacing Tile weight Main Runner spacing 1800 mm 1800 mm TLX Cross Tee 13 34 32 Main Runner spacing 1200 mm 1200 mm TLX Cross Tee 13 30 31 Main Runner spacing 600 mm 600 mm TLX Cross Tee 13 20 31 2,5 kg/m 1650 1900 2100 3,0 kg/m 1600 1800 2100 3,5 kg/m 1500 1750 2100 4,0 kg/m 1450 1700 2100 5,0 kg/m 1350 1600 2000 5,5 kg/m 1350 1550 1950 6,0 kg/m 1250 1500 1900 7,0 kg/m - 1450 1800 8,5 kg/m - 1300 1700 10,5 kg/m - 1200 1600 13,0 kg/m - 1050 1500 2 2 2 2 2 2 2 2 2 2 2 Universal Retaining Clip 0,70 pcs Perimeter Trim approx. 0,70 lm/m Prelude 24 TLX System 7 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 43 General Applications PRELUDE 24 TLX General Applications PRELUDE SIXTY 2 Exposed 24 mm grid system (nominal). Double Peakform Main Runner section requiring less suspension points and compatible with Prelude 24 XL 2 and TLX Cross Tees. For corridor applications please see page 50 - 51. Universal Main Runner Prelude Sixty2 Double Peakform with Superlock Clip (bulb to bulb connection) Item Nr. Dimensions Content / Carton pcs lm Weight / Carton Cartons / Pallet Length (mm) Height (mm) kg 40 40 93 G(1) 3600 62 12 43,20 21,90 36 40 41 93 G(1) 3750 62 12 45,00 22,80 36 40 43 93 G(1) 3375 62 12 40,50 20,60 36 Universal Main Runner Prelude Sixty2 Length 3750 3600 3375 156,25 150 168,75 11 x 312,5 11 x 300 9 x 337,5 156,25 150 168,75 Cross Tees Prelude 24 TLX (hook system, butt cut) Cross Tees slotted 13 31 31(1) 13 30 31(1) (2) 13 60 31 1250 1200 600 38 38 38 60 60 60 75,00 72,00 36,00 18,90 18,10 9,10 72 72 144 13 10 32 13 34 32 13 50 32 13 36 32 13 33 31 13 32 32 1875 1800 1724 1500 1350 1000 38 38 38 38 38 38 30 30 30 30 60 60 56,20 54,00 51,70 45,00 81,00 60,00 17,80 17,10 16,50 14,50 19,60 19,40 20 20 20 20 20 72 Cross Tees unslotted 13 18 31 13 16 31 13 21 31(1) 13 20 31(1) (2) 900 750 625 600 38 38 38 38 60 60 60 60 54,00 45,00 37,50 36,00 13,60 11,40 9,50 9,10 72 72 144 144 13 23 31 13 22 32 675 500 38 38 60 60 40,50 30,00 8,70 9,70 144 80 Cross Tees slotted 31 33 31 31 31 51 B(1) 31 30 51 B(1) 31 32 31(3) 1350 1250 1200 1000 38 38 38 38 60 60 60 60 81,00 75,00 72,00 60,00 17,20 18,90 18,20 15,10 20 72 72 42 31 34 31 A 1800 38 30 54,00 17,00 20 Cross Tees unslotted 31 16 32 31 25 32 31 24 32 31 23 21 31 21 23 A(1) 31 20 21 A(1) 31 22 21(3) 750 312,50 300 675 625 600 500 38 38 38 30 30 30 30 60 60 60 60 60 60 60 45,00 18,75 18,00 40,50 37,50 36,00 30,00 14,70 4,60 4,60 7,70 8,60 8,20 6,80 72 144 144 144 144 144 84 Cross Tees Prelude 24 XL2 (stab system, override) All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below. (1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR). (2) Also available in Black (NG), Brown (MR), Beige (BJ). (3) Also available in RAL 9010 (WR). All measurements in millimetres. All sizes are nominal. 44 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing (module 1800 x 300 mm) Standard lay-in installation of 24 mm exposed suspension system using Board or Tegular edge planks. Quantities required per 1m2 (no waste included) 3 Tile 1 Main Runner centres 1800 x 300 mm 600 x 600 mm 1200 x 600 mm Main Runner 2 2 Cross Tee 1800 mm Cross Tee 1200 mm 2 Cross Tee 600 mm 1800 mm 0,56 lm 3,34 lm - - 1800 mm 0,56 lm 1,67 lm - 1,12 lm 1200 mm 0,84 lm - 1,67 lm 0,84 lm 600 mm 1,67 lm - - 1,67 lm 1200 mm 0,84 lm - 1,67 lm - 600 mm 1,67 lm - - 0,84 lm The chart is for general guidance only. Accessories Item Nr. Description A 401 G Top Connector Clip accessory for Prelude Sixty2 (Included in the carton) A WDN 23 G Double bent tee bar hanger Dimensions Content/Carton Weight/Carton Length (mm) Height (mm) pcs kg - - - - 57 36 100 2,30 Grid Load Capacities 2 Prelude Sixty System The following table gives the maximum permitted hanger distance (mm) along the double Peakform Main Runner (40 40 93 G) for the tile weights and Main Runner spacings noted. Hanger spacing Tile weight Main Runner spacing 1800 mm 1800 mm Cross Tees 31 34 31 A/13 34 32 Main Runner spacing 1200 mm 1200 mm Cross Tees 31 30 51 B/13 30 31 Main Runner spacing 600 mm 600 mm Cross Tees 31 20 21 A/13 20 31 2,5 kg/m 2300 2400 2400 3,0 kg/m 2200 2400 2400 3,5 kg/m 2150 2350 2400 4,0 kg/m 2100 2300 2400 5,0 kg/m 2000 2200 2400 5,5 kg/m 1900 2150 2400 6,0 kg/m 1850 2100 2400 7,0 kg/m - 2050 2400 2 2 2 2 2 2 2 2 - 1900 2300 10,5 kg/m - 1700 2200 13,0 kg/m - 1550 2100 8,5 kg/m 2 2 2 Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 45 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. General Applications PRELUDE SIXTY 2 General Applications PRELUDE 35 XL 2 Exposed 35 mm grid system (nominal). For use in large shed type buildings including retail outlets, industrial manufacturing and meeting halls, etc... Main Runners Peakform Prelude 35 XL2 (bulb-to-bulb connection) Item Nr. Dimensions Content / Carton length (mm) height (mm) 43 mm 35 mm Weight / Carton pcs lm kg Cartons / Pallet White capping 24 40 42 3600 43 16 57,60 22,20 20 Galvanised capping 24 40 42 UP 3600 43 16 57,60 23,50 20 Black capping 24 40 42 BK 3600 43 16 57,60 22,20 20 Cross Tees Peakform Prelude 35 XL2 (stab system, override) 43 mm 35 mm 43 mm 35 mm White capping 24 06 42 24 36 42 24 30 42 24 20 42 1990 1500 1200 600 43 43 43 43 16 32 36 36 31,80 48,00 43,20 21,60 12,30 16,60 14,90 7,50 20 20 60 120 Galvanised capping 24 06 42 UP 24 36 42 UP 24 30 42 UP 24 20 42 UP 1990 1500 1200 600 43 43 43 43 16 32 36 36 31,80 48,00 43,20 21,60 13,00 17,70 15,90 8,00 20 20 60 120 Black capping 24 06 42 BK 24 36 42 BK 24 30 42 BK 24 20 42 BK 1990 1500 1200 600 43 43 43 43 16 32 36 36 31,80 48,00 43,20 21,60 12,30 16,60 14,90 7,50 20 20 60 120 Weight / Carton Cartons / Pallet Perimeter Trim Item Nr. Description Dimensions length (mm) 30 30 30 Content / Carton height (mm) pcs lm kg T 3024 H Perimeter angle, White painted 3000 24 40 120,00 28,50 50 T 3030 H* Perimeter angle, White painted 3000 30 30 90,00 25,00 40 * Also available in Galvanised (UP) and Black (BK) Please add the corresponding suffix to the item number when placing the order. Section Drawings Main Runners Prelude 35 Length 3600 50 100 33 x 100 100 50 Cross Tee Prelude 35 XL2 Length 1200 600 Cross Tee Prelude 35 600 XL2 1990 / 1500 / 600 Cross Tee alignment is achieved by locating the tees to the right-hand side of the adjoining section. All dimensions in millimetres. All sizes are nominal. 46 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Key Attributes • • Physical Data • Material Double-web galvanised steel Peakform Patented universal Main Runner and Cross Tee design increase strength and stability for improved performance and makes the grid easier to cut • Surface Finish Baked polyester paint • Product Family Exposed tee system Rotary stitched Main Runner and Cross Tees for additional torsional strength and extra stability during installation • Main Runner / Cross Tee Interface Joggled ends • End Detail Main Runner : with Superlock clip, by pass coupling, single stitching Cross Tees : staked-on stab clip, double stitching • Colour Available in White, Galvanised and Black. Grid Load Capacities Prelude 35 XL2 System The following table gives the maximum permitted hanger distance (L) along the Main Runner (24 40 42). Hanger spacing Tile weight Main Runner spacing 1990 mm (x 1000 mm) 1990 mm XL2 Cross Tee 24 06 42 Main Runner spacing 1500 mm (x 1000 mm) 1500 mm XL2 Cross Tee 24 36 42 Main Runner spacing 1200 mm (x 600 mm) 1200 mm XL2 Cross Tee 24 30 42 Main Runner spacing 600 mm (x 600 mm) 600 mm XL2 Cross Tee 24 20 42 2,5 kg/m2 1700 1900 1900 2000 3,0 kg/m2 1600 1800 1850 2000 3,5 kg/m2 1550 1700 1750 2000 4,0 kg/m2 - 1650 1700 2000 4,5 kg/m2 - 1600 1650 2000 5,0 kg/m2 - 1550 1600 2000 5,5 kg/m2 - 1500 1550 1950 6,0 kg/m2 - 1400 1500 1900 6,5 kg/m2 - 1350 1500 1900 7,0 kg/m2 - 1300 1450 1850 8,0 kg/m2 - 1250 1400 1750 9,0 kg/m2 - - 1300 1700 10,0 kg/m2 - - 1250 1650 12,0 kg/m2 - - 1150 1550 14,0 kg/m2 - - 1050 1450 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 47 General Applications PRELUDE 35 XL 2 General Applications BANDRASTER Bandraster is a suspension system available in a wide range of widths, compatible with Prelude 24 TLX/XL 2 Cross Tees. Bandraster Systems Item Nr. Dimensions length (mm) Height (mm) Content / Carton pcs Weight / Carton lm Cartons / Pallet kg 36mm 12mm 150 / 125 / 100 / 75 / 50mm Slotted at 312,50 mm (1) 36 2100 B 3750 100 8 30,00 32,60 16 Slotted at 100 mm (1) 36 3050 36 3075 36 3100* 36 3125 36 3150 3600 3600 3600 3600 3600 50 75 100 125 150 8 8 8 8 4 28,80 28,80 28,80 28,80 14,40 24,00 27,70 31,40 38,30 21,20 28 20 16 12 20 Unslotted (2) 36 0050 A 36 0075 A* 36 0100 A 36 0125 A 36 0150 3600 3600 3600 3600 3600 50 75 100 125 150 8 8 8 8 4 28,80 28,80 28,80 28,80 14,40 24,00 27,70 31,40 38,30 21,20 28 20 16 12 20 (1) Is compatible with all plank edge details whether cross tees are required or not. (2) Is compatible with only with plank edge details when no visible cross tees span between bandraster sections. Bandraster Accessories Item Nr. Description Dimension height (mm) Content / Carton Weight / Carton pcs kg A 36 0501 A 36 0751 A 36 1001 Strip / rod connector 50 75 100 50 50 50 1,20 1,50 1,80 A 36 0502 G A 36 0752 G A 36 1002 G A 36 1252 G A 36 1502 G Nonius hanger 50 75 100 125 150 100 100 100 100 100 5,80 8,10 11,00 12,50 15,00 A 36 0503 G A 36 0753 G A 36 1003 G A 36 1253 G A 36 1503 G Splice 50 75 100 125 150 100 100 100 100 100 8,00 8,30 14,00 17,00 19,50 A 36 0504 G A 36 0754 G A 36 1004 G A 36 1254 G A 36 1504 G Cross connector 50 75 100 125 150 100 100 100 100 50 5,80 8,10 11,00 12,50 7,50 A 36 0505 G A 36 0755 G A 36 1005 G A 36 1255 G A 36 1505 G Wall connector 50 75 100 125 150 100 100 100 100 50 5,80 8,10 11,00 12,50 7,50 A 36 0506 G A 36 0756 G A 36 1006 G Crossing element 50 75 100 48 30 32 7,70 5,70 7,40 Product available as standard in Global White. *Also available in RAL 9010 (WR) All measurements in millimetres. All sizes are nominal. 48 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing - Slotted Bandraster is compatible either with Prelude 24 XL2 or Prelude 24 TLX Cross Tees - On special request: Prelude 15 TL can be made compatible for installation with slotted Bandraster; - Special spaced slotting; minimum slot spacing is 50 mm; Maximum length of Bandraster is 5000 mm Upper part of Nonius Pin to connect bottom and upper part of Nonius A 10229 G (It is recommended to use 2 pins to connect bottom & upper part of Nonius) Splice Nonius hanger Strip / rod connector Cross connector Crossing element Wall connector Threaded rod A 1829 G Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 49 General Applications BANDRASTER General Applications SYSTEM Z Semi-concealed and concealed systems. Provides specialist solution for corridors giving a monolithic visual. Can also be used for room situations in conjunction with Prelude 24 and Bandraster grid. Semi-Concealed - Compatible with SL2 Item Nr. Description Dimensions Content / Carton length (mm) pcs Weight / Carton lm kg CZ 41494 H CZ 41794 H CZ 41795 H Deep Z 32 mm Deep Z 32 mm Deep Z 70 mm 1500 1800 2500 20 20 10 30,00 36,00 25,00 9,40 11,30 13,40 CA 5740 G Double height Z 4000 10 40,00 24,00 CA 5733 A Spacer bar 600/625 50 31,20 7,00 CA 5734 Spacer bar 1200/1250 50 62,50 14,00 CZ 3600 H Z section 3600 20 72,00 22,70 CA 21 G Z connector 150 500 - 10,00 CC 4000 G C 3000 G Channel 13 x 38 mm Channel 19 x 38 mm 4000 4000 20 8 80,00 32,00 26,50 23,80 CA 120 G Preformed channel clip - 100 - 0,50 Semi-Concealed CZ 3600 H CA 21 G CC 4000 G CA 120 G All measurements in millimetres. All sizes are nominal. 50 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Semi-Concealed (continued) Item Nr. Description Dimensions Content / Carton length (mm) CA 97 G Clamp for C-channel CT 600 G CA 5730 G pcs Weight / Carton lm kg 30 100 - 1,70 Noggin tee 600 100 60 8,50 Anti-breather spline 295 200 - 3,80 CC 4000 G System Drawing Semi-concealed SL2 Corridor installation SL2 Quantities required per 1m2 (no waste included) 3 Plank size 1500 x 300 / 312,5 mm 1800 x 300 / 312,5 mm 2500 x 300 / 312,5 mm 2 Supporting sections at 300 / 312,5 mm 300 / 312,5 mm 300 / 312,5 mm 1 Z Profile CZ 41494 H Z Profile CZ 41794 H Z Profile CZ 41795 H 3,33 / 3,20 lm - 3,33/3,20 lm - 3,33 / 3,20 lm Perimeter trim according to circumference of room Perimeter angles should be of thicker material when corridor wider than 1,80 m. The chart is for general guidance only. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 51 General Applications SYSTEM Z General Applications DRYWALL GRID SYSTEM The Drywall Grid System (DGS) is a quick and easy to install suspension system for plasterboard ceilings, available in a range of two unique systems : Standard for typical flat installations and Faceted for curved and domed ceilings. Peakform Main Runner and Superlock Clip (bulb to bulb connection) Item Nr. Dimensions Content / Carton length (mm) height (mm) width (mm) 43 Weight / Carton pcs Im kg Cartons / Pallet Main Runners 7940 G slot at 150mm 7942 G slot at 150mm 7941 G slot at 100mm 3600 3000 3600 38 38 38 38 38 38 12 12 12 43,20 36,00 43,20 20 17 19,52 36 36 36 Faceted Main Runners HD 8906 F08 G HD 8906 F16 G 3658 3658 43 43 38 38 12 12 43,92 43,92 22 22 24 24 Cross Tees 7930 G 7918 7920 G 1200 900 600 38 38 38 38 38 38 36 36 36 43,20 33,00 21,60 20 15 10 48 48 96 Unhemmed C channel 7838 G 3048 (120") 40 20 60.96 16 32 Knurled angle trim KAM 12 H 32 30 109.72 26 12 19 3658 (12') 32 Accessories A variety of Drywall Grid accessories are available to provide problem solving solutions that save time, labour and money. Item Nr. Image DW50 LT Transition clip13 mm plasterboard (1/2") DW58 LTAG Transition clip for 15 mm plasterboard (5/8") Item Nr. Image Item Nr. DWACS AG Drywall attachment clip MBSC2 AG Main Runner spacer clip DW30C AG DW45C AG DW60C AG DW90C AG Drywall angle clips XTAC AG Cross Tee adapter clip Image DLCC AG Direct load ceiling clip RC2 AG Radius clip BP DWC AG Drywall clip MBAC AG Main Runner adapter clip All measurements in millimetres. All sizes are nominal. 52 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Section Drawing Main Runner Length 7940 G 7941 G 7942 G 3600mm 3600mm 3000mm 23 x 150 mm 35 x 100 mm 19 x 150 mm 75 mm 50 mm 75 mm Faceted Main Runners 75 mm 50 mm 75 mm faceted at 203mm centres. Use for radius 4.50m or less HD 8906 F08 G (54 slots) 3658mm Faceted at 406mm centres. Use for radius over 4.50m (directional Main Runner) HD 8906 F16 G (45 slots) 3658mm Cross Tees 7930 G 1200mm 7920 G 600mm 7918 G 900mm System Drawing Hanger wire or suspension angle Vertical brace Main Runner Cross Tee For more information, please ask for the Drywall Grid System Curved and Flat brochure. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 53 General Applications DRYWALL GRID SYSTEM Corridor DRYWALL GRID SYSTEM SHORTSPAN The Drywall Grid System (DGS) ShortSpan is a quick and easy to install suspension system for plasterboard ceilings and in particular for corridors in both commercial and residential installations. Drywall Grid System (DGS) Shortspan product range Item Nr. Dimensions length(mm) height (mm) Content / Carton pcs Weight / Carton Im Cartons / Pallet kg Shortspan T-bars S 7708 G 2438 (8') 38 12 29,26 13 S 7710 G 3048 (10') 38 12 36,57 17 24 24 S 7712 G 3658 (12') 38 12 43,89 20 24 S 7714 G 4267 (14') 38 12 51,20 23 24 Locking angle trims Locking tabs at 150mm for the BP LAT 12H Locking tabs at 100mm for the BP LAT 10H Knurled angle trim LAT 12 H 3600 32 30 109,72 18 12 LAT 10 H 3600 30 30 110,00 15 12 32 10 36.60 9 50 KAM 12 B 3660 (12') The ShortSpan system is designed for use in drywall ceilings where the spans do not exceed 4200mm. The individual ShortSpan tees are not designed to be used independent of the locking angle trim (LAT 12 H) or optional knurled angle trim (KAM 12 B). System Drawing The gap between wall trim and shortspan should not be over 3mm Locking tab Alignment crimps LAT 12/10 H must be screwed to wall structure Locking tabs 150/100mm at 150/100mm centres. For more information, please ask for the Drywall Grid System Standard and Faceted brochure. 54 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Exposed 24 mm grid system. Double Peakform Main Runner section requiring less suspension points and compatible with Prelude 24 XL 2 and TLX Cross Tees. Universal Main Runner Prelude Sixty 2 Double Peakform and Superlock Clip (bulb to bulb connection) The Prelude Sixty2 system is designed for use in corridor applications, with or without Cross Tees, and where spans do not exceed 3750 mm. For a wider configuration, the Main Runner is compatible with the Prelude 24 TLX and XL2 Cross Tees. Special length and modulation made to order, with and without slots, please contact your Armstrong Technical Sales team. Accessories Item Nr. Description A WDN23 G Double bent tee bar hanger Dimensions Content / Carton Weight / Carton Length (mm) Height (mm) pcs kg 57 36 100 2,30 System Drawing Double bent tee bar hanger Planks Perimeter trim Grid Load Capacities Spacing (mm) 1600 1700 1800 1900 Span in mm - Load capacities in kg/m2 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 Prelude Sixty2 300 37,2 32,8 29,1 25,9 23,2 20,9 18,9 17,2 15,6 14,3 13,1 11,8 10,0 8,5 7,1 Butt cut 600 18,6 16,4 14,5 13,0 11,6 10,5 9,5 8,6 7,8 7,1 6,5 5,9 5,0 4,2 3,5 1200 9,3 8,2 7,3 6,5 5,8 5,2 4,7 4,3 3,9 3,5 3,2 - - - - 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. (1) Colours available: Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Chrome (CE), White RAL 9010 (WR), Brass (BS). 55 Corridor PRELUDE SIXTY 2 Specific Applications CLEAN ROOM GRID SYSTEM Exposed 24 mm grid system (nominal). A complete system solution: Aluminium construction for maximum corrosion resistance and non-magnetic environments. Co-extruded with a unique factory applied gasket for a better seal between tile and grid. System suitable for use in applications up to Class 4 performance as per Class ISO standard 14644-1. Main Runner Clean Room Grid System 24 Item Nr. Dimensions Content /Carton length (mm) height (mm) EA 794044 3600 43 pcs lm 20 72,00 Weight/Carton Cartons/Pallet kg 24,00 30 Cross Tees Clean Room Grid System 24 + Perimeter Trim EA 793044 1200 43 60 72,00 26,00 20 EA 792044 600 43 60 36,00 12,00 40 3660 24 30 109,80 20,00 25 EA 7801 Accessories CHDC Hold down clip suitable for non-magnetic areas A 426 Board access clip 18 12 16 Section Drawings Main Runner Clean Room Grid 24 Length 3600 150 300 9 x 300 300 150 Cross Tee Clean Room Grid 24 Length 1200 600 300 300 300 300 300 300 All measurements in millimetres. All sizes are nominal. Please contact Armstrong Technical Sales for further details. 56 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Key Attributes Physical Data • Aluminium construction for maximum corrosion resistance and non-magnetic environments • Material Co-Extruded Aluminium – Gasketed • Unique co-extruded section aluminium based • Cross Tee/Main Runner Interface Co-Extruded Aluminium Clean Room – Flush Fit • Unique, factory applied gasket for a better seal between tile and grid • Product family Exposed grid system • Staked on Main Runner splice for easy connections, integral hook Cross Tee end detail • End Detail Main Runner: Staked-on clip Cross Tee: Integral hook • Hold down clips to ensure a good seal • System suitable for use in applications up to Class 4 performance per ISO standard 14644-1 Clean Room Hold-down clip (CHDC) Clean Room Cross Tee Clean Room Main Runner Board Tile Grid Load Capacities Clean Room Grid 24 mm The table gives the maximum permitted hanger distance (mm) along the Clean Room Grid Main Runner (EA 794044) for the tile weights and Main Runner spacings noted. Hanger spacing Tile weight Main Runner spacing 1200 mm 1200 mm Cross Tee EA 793044 2,5 kg/m 1850 2100 3,0 kg/m 1750 2100 3,5 kg/m 1700 2100 4,0 kg/m 1650 2050 5,0 kg/m 1550 1950 5,5 kg/m 1500 1900 6,0 kg/m 1450 1850 7,0 kg/m 1400 1800 8,5 kg/m 1300 1700 10,5 kg/m 1200 1600 13,0 kg/m 1050 1450 2 2 2 2 2 2 2 2 2 2 2 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. Main Runner spacing 600 mm 600 mm Cross Tee EA 792044 All measurements in millimetres. All sizes are nominal. Please contact Armstrong Technical Sales for further details. 57 Specific Applications CLEAN ROOM GRID SYSTEM Specific Applications PRELUDE 24 CORROSIVE RESISTANT Exposed 24 mm grid system (nominal). Special paint finish and TLX steel-based composite clip for enhanced corrosion resistance. Corrosion resistance 700 hours salt spray test on grids according to EN ISO 9227 standards. Durability Class C (EN13964:2004 + A1:2006) Universal Main Runners 24 Corrosive Resistant Peakform and Superlock Clip (bulb to bulb connection) Item Nr. Dimensions Content / Carton length (mm) height (mm) 28 40 42 28 41 42 3600 3750 pcs 43 43 20 20 Weight / Carton lm Cartons / Pallet kg 72,00 75,00 21,00 21,90 30 30 Cross Tees TLX 24 Corrosive Resistant (Hook system, butt cut) 14 30 32 14 31 32 1200 1250 38 38 60 60 72,00 75,00 18,20 18,90 72 72 14 20 32 14 21 32 600 625 38 38 60 60 36,00 37,50 9,10 9,50 144 144 156,25 100 78,125 50 Section Drawings Main Runner 24 Corrosive Resistant Length 3750 3600 78,125 50 156,25 100 21 x 156,25 33 x 100 Cross Tee TLX 24 Corrosive Resistant Cross Tee TLX 24 Corrosive Resistant Length 1200 300 300 300 300 1250 312,5 312,5 312,5 312,5 600/ 625 Perimeter Solution Item Nr. Description Dimensions length (mm) height (mm) T 1924 LB Corrosive resistant perimeter angle 3050 24 Content / Carton pcs 36 Weight / Carton Im kg 109,80 27,60 Accessories - Corrosion resistance 700 hours salt spray test For loading data please see standard versions of these items on pages 66-67. A WDNCR 20 H Bent tee bar hanger for threaded rod A CR1829 G 1000mm Threaded rod dia. 6 mm A CR1827 G Nut for threaded rod A CR7890 G Universal retaining clip A CR827 G 1700 mm hanger with hook A CR11 G Small hook A CR12 G Butterfly T 1924 LB Corrosive resistant suspension angle Availability of products may vary according to location. 58 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing (module 1200 x 600 mm) Standard lay-in installation of 24 mm exposed suspension system using Board or Tegular edge tiles. *reduce to 450 if heavy tile / overlays are used or heavy service fittings are located near the perimeter. Quantities required per 1m2 (no waste included) 6 1 Tile Main Runner centres Hanger centres 1200 x 600 mm 1,39 pcs 1200 mm 1200 mm 0,84 lm 600 mm 1200 mm 1,67 lm 600 x 600 mm 2,78 pcs 1200 mm 1200 mm 0,84 lm 600 mm 1200 mm 1,67 lm 5 Main Runner 2 3 Cross Tee 1200 mm 1,67 lm Cross Tee 600 mm - 1,67 lm - 2 Perimeter Trim approx. 0,70 lm/m 4 Hanger 7 Universal Retaining Clip 0,70 pcs 5,56 pcs 0,84 lm 1,40 pcs 5,56 pcs 0,84 lm 0,70 pcs 5,56 pcs 1,67 lm 1,40 pcs 5,56 pcs The chart is for general guidance only. Grid Load Capacities Prelude 24 Corrosive Resistant The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (28 40 42) for the tile weights and Main Runner spacings noted. Hanger spacing Tile weight Main Runner spacing 1200 mm 1200 mm Cross Tee 14 30 32 Main Runner spacing 600 mm 600 mm Cross Tee 14 20 32 2,5 kg/m 1900 2100 3,0 kg/m 1800 2100 3,5 kg/m 1750 2100 4,0 kg/m 1700 2100 5,0 kg/m 1600 2000 5,5 kg/m 1550 1950 6,0 kg/m 1500 1900 7,0 kg/m 1450 1800 2 2 2 2 2 2 2 2 8,5 kg/m 1300 1700 10,5 kg/m 1200 1600 13,0 kg/m 1050 1500 2 2 2 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 59 Specific Applications PRELUDE 24 CORROSIVE RESISTANT Specific Applications SEISMIC Rx®SYSTEM Exposed 24mm grid system (nominal). Independently tested approach using Prelude XL2 grid to achieve ceiling installations that can withstand the forces associated with significant seismic activity or other severe events. Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection) Item Nr. Dimensions Content / Carton length (mm) height (mm) 31 40 32 A(1) 31 41 33 B pcs Weight / Carton lm Cartons / Pallet kg 3600 3750 43 43 20 20 72,00 67,50 21,00 20,00 30 30 1200 1250 38 38 60 60 72,00 75,00 18,20 18,90 72 72 600 625 30 30 60 60 36,00 37,50 8,20 8,60 144 144 Cross Tees Prelude 24 XL2 (stab system, override) Cross Tees slotted 31 30 51 B(1) 31 31 51 B(1) Cross Tees unslotted 31 20 21 A(1) 31 21 23 A(1) Accessories Item Nr. Description Dimensions Quantity / Carton Weight / Carton length (mm) pcs kg Cartons / Pallet T 3024 H Perimeter angle, painted 3000 40 28,50 50 BERC2 Main Runner end retaining clip 50 200 9,00 36 SJCG Seismic joint clip XL2 Cross Tee (24mm) - 200 7,00 36 SJMR15 Seismic joint clip Peakform Main Runner (24mm) 100 11,00 60 ES 4 Expansion sleeve (24mm) 100 100 1,00 170 442 Vector Seismic clip - 100 1,63 - (1) Standard Colours available : BK (Black), CA (Carrara), PN (Platinum), BS (Brass), CE (Chrome), SG (RAL9006), WR (RAL 9010). A further 180 RAL colours are available as a special on request. Please contact your local sales office. Availability of products may vary according to location. 60 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie System Drawing • • • T 3024 H perimeter trim BERC2 on all (four) sides of room prevents ends of Cross Tees and Main Runners from spreading apart 20mm clearance on two adjacent sides and 10mm overlap of grid on the perimeter trim Attached Wall Attached Wall Detail A A A B Tight Screw 200mm MAX Main Runner B Main Runner x x x x x x B Unattached Wall Detail 200mm MAX Unattached Wall 30 mm B B B B 30mm 600mm c/c 20mm B B x x x Optional Screw B B Unattached Wall Hanger Wire Note: some recommendations / guidelines require additional hangers on perimeter Cross Tees within 200mm of the perimeter. This is not a requirement of the Seismic Rx®solution using the BERC2 clip, but may also be incorporated to provide additional system security in very high hazard areas e.g. emergency services control centre, where full functionality is planned post event. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 61 Specific Applications SEISMIC Rx®SYSTEM Specific Applications LONGSPA N SYSTEM LongSpan Grids are designed to create a primary framework underneath beams or between walls, thereby allowing the suspended ceiling Main Runners to be installed with fewer suspension points. Primary Channels Item Nr. Dimensions length (mm) height (mm) 120mm 85mm 54mm 40mm 70mm 40mm 40mm LP 546 G LP 706 G LP 856 G LP 120 G 5000 5000 5000 6500 54 70 85 120 Content / Carton pcs 5 5 5 5 Weight / Carton lm kg 25,00 25,00 25,00 32,50 18,40 23,60 25,10 63,30 Cartons / Pallet 10 10 10 10 40mm Accessories Item Nr. Description Dimensions height (mm) h Content / Carton Weight / Carton pcs kg - 50 2,00 47 47 100 100 2,20 3,20 A 4510 G Bent hanger for T profile A 1820 G A 1821 G Beam flange clip A B11067 G A B11066 G A B11065 G A B11064 G Special holding clamp* 54 70 85 120 100 100 100 50 3,10 4,30 4,60 3,30 A M4538 G A M4536 G A M4534 G A M4529 G Wall connection 54 70 85 120 25 25 25 25 1,30 1,70 3,20 5,90 A R4537 G A R4535 G A R4533 G A R4528 G Connector 54 70 85 120 25 25 25 25 1,90 2,30 4,20 7,00 CC 4000 G CA 120 G Channel 13 x 38 mm Preformed channel clip** 38 - 20 100 26,50 0,50 CC 4000 G CA 120 G *Both Bent hanger for T profile and special holding clamp only work with threaded rod A 1829 G+ Connector A1839 G + nut (A 1827 G) **Install one clip on each side of the Channel CC 4000 G All measurements in millimetres. All sizes are nominal. 62 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Specific Applications L O N G S PA N S Y S T E M System Drawing AR 45..... Connector AM 45.... Wall connector Steel beam Threaded rod A 1829 G + Connector A 1839 G + Nut A 1827 G CA 120 G Preformed channel clip CC 4000 G Channel (tie bar) 1200 A 182 ... Beam flange clip Steel beam A 4510 G Bent hanger for T profile 1200 LP... Primary channel Note : - Two wall connectors AM 45... must be used to fix to walls. - Two connectors AR 45... must be used when connecting two lengths of Primary Channel together. - Two preformed channel clips CA 120 G must be installed on the opposites sides of the Primary channel AB 11... Special holding clamp Grid Load Capacities (LongSpan System) Space 1200 mm 1 tie bar Spacing between suspensions (m) 1,25 2 tie bars 1,50 1,75 2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 6 4,25 4,50 3 tie bars 4,75 5,00 5,50 5,75 14 12 10 9 6,00 6,50 Item Nr. LP 546 G kg/m2 LP 706 G kg/m2 LP 856 G kg/m2 LP 120 G kg/m2 48 48 32 23 16 12 9 48 34 25 19 14 11 9 7 48 42 25 19 15 12 10 8 7 7 48 30 24 20 17 Note: Uniformly distributed load kg/m2. Load charges in kg/m2 for deflection L/300. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 63 8 6 Perimeter Solutions FLEXIBLE PERIMETER TRIMS Excellent solution for finishing ceilings around columns and convex walls, easily cut and curved by hand on site. Perimeter Trims 24 mm Item Nr. Dimensions Content / Carton length (mm) height (mm) pcs White FT 2424 FT 1929 2500 2500 24 29 Black FT 2424 BK FT 1929 BK 2500 2500 24 29 Weight / Carton Cartons / Pallet lm kg 10 10 25,00 25,00 5,50 5,50 50 50 10 10 25,00 25,00 5,50 5,50 50 50 24 mm 29 mm 19 mm Accessory Item Nr. A WDN 23 G Description Double bent tee bar hanger Dimensions Content / Carton Weight / Carton length (mm) height (mm) pcs kg 100 2,30 57 36 Key Attributes Physical Data • Optimum length for most columns with a 2.5 m length • Easy to cut and to bend to necessary radius • Material Steel core with PVC tape • Available in 2 colours (White and Black) • 3 ply white PVC tape for a better visual • Quick fix for columns and convex curves • Product Family Perimeter Trims • Coating PVC • Colour Available in Global White and Black. 64 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Perimeter Detailing 1 The white Flexible trim has THREE layers of white PVC coating to avoid the ‘greyish’ visual appearance between the steel supported zone ‘G’ and the PVC only zone ‘P’. P 50 mm G 50 mm 2 The Flexible trim should follow the same rule of being fixed onto the wall with 450 mm spacing. 450 Pillar 3 These trims are considered decorative elements therefore any grid laying on them will need : A) A hanger support onto the grid laid onto the flexible trim as close as possible from the edge of the trim. B) Use the accessory A WDN 23 G to support the load above the trim. Note: These trims can be used only in curved TOE OUT ( Convex ) installations (19 x 29 section must be installed with the 29 mm face vertical). Minimum bending radius : 200 mm. Minimum environment temperature during the curving operation : 20ºC. Due to the nature of the PVC coating, these trims do not exactly match our standard black & white colour and gloss. Fire reaction classification Euroclass F (EN 13501-1) - please check local/country regulations for compliance. Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 65 Perimeter Solutions FLEXIBLE PERIMETER TRIMS Mineral Perimeter Solutions PERIMETER SOLUTIONS A comprehensive range of the most commonly used perimeter profiles, including shadowline, F upstands and cover plates, finished to match all Prelude 24 mm and 15 mm, Bandraster and Prelude 35 grid systems. Item Nr. T 1924 HD Description Dimensions Content / Carton Weight / Carton length (mm) thickness (mm) pcs lm kg Perimeter angle, painted 3000 0,54 36 108,00 22,70 T 1924 CA (1) Perimeter angle, capped 3050 0,60 36 109,80 27,60 T 1924 LB Perimeter angle, corrosive resistant 3050 0,55 36 109,80 27,60 T 1932 HA Perimeter angle, painted 3000 0,45 36 108,00 21,80 T 1919 HC Perimeter angle, painted 3000 0,45 36 108,00 19,30 T 2401 H T 2400 H Perimeter angle, painted heavy duty 3050 Perimeter angle, painted 3050 intermediate duty 0,70 0,60 30 30 91,50 91,50 22,00 20,00 T 2424 HC Perimeter angle, painted 3050 0,45 36 109,80 21,60 T 3024 H Perimeter angle, painted 3000 0,45 40 120,00 28,50 T 3030 H Perimeter angle, painted 3000 0,54 30 90,00 25,00 T 1506 H Shadowline, painted 3050 0,45 36 109,80 26,30 T 1508 HB Shadowline, painted 3050 0,45 36 109,80 27,10 T 2020 HH Shadowline, painted 3000 0,65 20 60,00 27,00 7875 G Shadowline, painted, for Optima Vector, Ultima Vector, Dune Vector 3050 0,45 30 91,50 26,80 T 2121 HG Shadowline, air circulation length of slot: 50 mm Distance between slots 20 mm (ca. 16% open area) 3000 0,60 25 75,00 41,20 T 2040 HB C channel, painted 3050 0,45 20 61,00 18,10 T 7837 C channel, painted 3050 0,45 40 73,10 24,00 30 30 30 All products standard in Global White. Other standard colours available for item numbers with index (1). See details below. (1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR), Opal (OL), Brown (BN), Ivory (IY), Blue (BE), Red (RD), Green (GN). All measurements in millimetres. All sizes are nominal. 66 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Mineral suspension system. Perimeter Trims Item Nr. Description Dimensions Content / Carton length (mm) thickness (mm) Weight / Carton pcs lm kg T 2040 H WR A C channel, colour RAL 9010 3050 0,50 20 61,00 18,10 T 2040 H SG A C channel colour RAL 9006 3050 0,45 20 61,00 18,10 T 1575 HA Unequal U-Profile, painted 3050 0,45 36 109,80 24,20 7856 H F Upstand trim, painted, for 16 mm thick panels 3050 0,45 20 61,00 23,70 7852 H F Upstand trim, painted, for 13 mm thick panels 3050 0,45 20 61,00 23,00 Perimeter Detailing A 156 G / A 246 G Perimeter fill-in for Tegular and MicroLook tiles A 1796 G Perimeter wall spring 40 24 00 .3 ca 00 .3 ca 19 20 Standard perimeter finish with perimeter angle T 1924 HD or T 1924 CA 25 Perimeter finish with C channel T 2040 HA 1 A 7890 G Universal retaining clip 32 00 .3 ca 6 15 15 7,5 00 .3 ca 15 Perimeter finish with unequal U-Profile T 1575 HA Perimeter finish with shadowline T 1506 H Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details. 67 1 Mineral Perimeter Solutions PERIMETER SOLUTIONS Metal Perimeter Solutions PERIMETER SOLUTIONS Metal suspension system. Perimeter Trims for Metal Ceilings Item Nr. Description Dimensions length (mm) Content / Carton Weight / Carton pcs lm kg 3050 20 61,00 18,10 200 100 - 5,00 T 2040 H WR A Perimeter channel RAL 9010 20 x 40 mm C 1803 H Perimeter wedge M 215013 Perimeter trim RAL 9010 25x 25 mm 4000 10 40,00 8,00 M 215014 Shadowline RAL9010 20x20x20x25 mm 4000 10 40,00 13,50 M 215015 Shadowline RAL9010 20x15x10x25 mm 4000 10 40,00 11,00 M 311081 Cut tile spring wedge 40 100 - 0,30 Perimeter trims also available in Global White. 68 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Metal suspension system. Perimeter Detailing for Metal Ceilings 25 25 M 311081 – Cut tile spring wedge M 215013 – Aluminium perimeter angle trim 20 10 M 311081 15 25 M 215015 Aluminium shadowline trim Cut Tile Spring Wedge M 311081 1-2 pieces per 300mm of perimeter trim. Perimeter wedge C 1803 H 1 piece per 300mm of perimeter trim. 40 20 C 1803 H T 2040 H WR A Perimeter channel and perimeter wedge for cut modules All measurements in millimetres. All sizes are nominal. 69 Metal Perimeter Solutions PERIMETER SOLUTIONS Accessories ACCESSORIES Suspension & Accessories Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) A W950 G Suspension wire dia. 2 mm A 1843 G Expanded bolt for threaded rod dia. 6 mm A 1829 G Threaded rod dia. 6 mm A 1839 G Connection for threaded rod dia. 6 mm A 1827 G Nut for threaded rod A WDN20 H Bent tee bar hanger for threaded rod Admissible Load * pcs kg kg 1 coil 4,70 41 25 100 0,50 1000 50 8,50 20 100 0,60 100 0,20 100 1,40 ca. 200 metres 57 20 (tested with 6 mm threaded rod) A 14 G Universal clip 40 100 1,00 A WDN21 H T bar hanger - 20 0,30 32 A WDN23 G Double bent T bar hanger with 2 sizes of diameter hole 57 100 2,30 32 A 11030 G Quick hanger - hook (2 hooks) 165-280 100 5,40 A 11020 G Quick hanger - hook (2 hooks) 215-380 100 4,10 A 11040 G Quick hanger - hook (2 hooks) 315-580 100 8,50 A 11070 G Quick hanger - hook (2 hooks) 415-780 100 10,50 A 11090 G Quick hanger - hook (2 hooks) 515-980 100 13,00 A 12030 G Quick hanger - eye (1 hook +1 eye) 165-280 100 5,20 A 12020 G Quick hanger - eye (1 hook +1 eye) 215-380 100 4,10 A 12040 G Quick hanger - eye (1 hook +1 eye) 315-580 100 8,30 A 12070 G Quick hanger - eye (1 hook +1 eye) 415-780 100 10,50 A 12090 G Quick hanger - eye (1 hook +1 eye) 515-980 100 13,00 41 41 * Note: These admissible loads have been determined from laboratory tests in accordance with EN 13964 : 2004 + A1 : 2006 and apply to the hangers and their grid connections only. No account has been taken of the strength of top fixings which must be selected as appropriate for the supporting structure and estimated load. 70 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Suspension & Accessories Item Nr. Description Dimensions length (mm) A 10202 H A 10203 H A 10204 H A 10205 H A 10206 H A 10208 H 300 400 500 600 700 800 Upper part of nonius Upper part of nonius Upper part of nonius Upper part of nonius Upper part of nonius Upper part of nonius Content / Carton Weight / Carton pcs 100 100 100 100 100 100 kg Admissible Load * kg 5,10 7,20 9,00 11,00 12,80 15,50 33 190 190 100 4,30 60 100 0,80 Suspension angle 3600 20 13,30 A 826 G A 827 G 2 m hanger with hook 1,7 m hanger with hook 2000 1700 100 100 20,00 20,00 A 11 G Small hook 120 100 2,00 A 12 H Butterfly 55 100 1,00 A 829 H Suspension hanger for T bar 130 100 2,80 A 10230 G Bottom part of nonius hanger A 10229 G Pin to connect bottom & upper part of nonius A 952 G 60 * Note: These admissible loads have been determined from laboratory tests in accordance with EN 13964 : 2004 and apply to the hangers and their grid connections only. No account has been taken of the strength of top fixings which must be selected as appropriate for the supporting structure and estimated load. Availability of products may vary according to location. All measurements in millimetres. All sizes are nominal. Please contact Armstrong Technical Sales for further details. 71 33 Accessories ACCESSORIES Accessories ACCESSORIES Suspension & Hold Down Clips Item Nr. Description Dimensions Content / Carton length (mm) pcs Weight / Carton kg A 1829 82 10 A 1837 G Rocking hanger 82 100 2,00 A 1838 G Hanger for wooden beam 148 100 3,20 A 1820 G Beam flange clip 1,6 - 4,8 mm thickness - 100 2,20 A 1821 G Beam flange clip 4,8 - 9,5 mm thickness - 100 3,20 A 1822 G Clip for quick hanger 1,6 - 4,8 mm thickness - 100 0,80 A 1823 G Clip for quick hanger 4,8 - 9,5 mm thickness - 100 3,00 A 7890 G Universal retaining clip - 100 0,40 A 819 G Locking hold down clip, for 6 - 30mm tiles (Peakform & Square bulb) 64 500 2,40 A 1060 T35 Hold down clip for panels up to 110 mm thick - 250 3,10 148 18 38 55 38 72 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie Hold Down Clips & Accessories Item Nr. 23 EHDC 58 AG 70 Description Exterior hold down clip Dimensions Content / Carton Weight / Carton length (mm) pcs kg 102 125 7,00 (Peakform & Square bulb) 102 66 22 50 A 7912 G Hold down clip for 40 mm soft fibre panels 68 100 1,10 A 7902 G Hold down clip for 18-25 mm soft fibre panels 40 100 1,10 A 426 Board access clip - 100 0,40 A 7930 G Last tile clip Tegular 40 25 0,05 A 7931 G Last tile clip MicroLook 40 25 0,05 MCC4 G Mitre closure clip for 6 mm Silhouette & Microline - 200 0,30 LFC G Peakform Corner support of lay-in light (Silhouette & Microline 15 mm grid) - 50 0,45 A 131 G T bar saddle clip (Peakform & Square bulb) 98 100 2,70 32 18 12 16 1. 8 2. 3. 24 4 38 Availability of products may vary according to location. All measurements in millimetres. All sizes are nominal. Please contact Armstrong Technical Sales for further details. 73 Accessories ACCESSORIES Accessories ACCESSORIES Perimeter Accessories Item Nr. 13 15 6 75 Description Dimensions Content / Carton length (mm) pcs Weight / Carton kg A 328 G Inside corner 19 mm 58 100 0,90 A 329 G Outside corner 19 mm 65,50 100 1,20 A 330 G Inside corner 24 mm 58 100 0,90 A 331 G Outside corner 24 mm 65,50 100 1,20 A 332 G Inside corner for shadowline T 1508 HB 72 100 1,60 A 333 G Outside corner for shadowline T 1508 HB 57,20 100 1,20 A 0415 G MicroLook border clip 19 500 0,80 A 0324 G Tegular border clip 29 500 1,20 A 156 G Perimeter fill-in for 15 mm grid - 500 0,40 A 246 G Perimeter fill-in for 24 mm grid - 500 0,50 o 19 13 24 6 75 29 15 6,5 6 o 24 74 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie UK Colour Info_Layout 1 15/11/2012 10:39 Page 3 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie WESTERN EUROPE Belgium & Luxembourg Armstrong Building Products B.V. Bureaux Commerciaux Belgique Postbus 3803 4800 DV Breda Nederland Tel.: (+32) 02 223 00 72 Fax: (+31) 076 521 04 07 e-mail: benelux-info@armstrong.com www.armstrong-plafonds.be Germany & Switzerland Armstrong Building Products Kundenservice Office Building Quadrium Claudius Prinsenlaan 126 4818 CP Breda Niederlande Tel.: (+49) 0251 7603 210 Fax: (+49) 0251 7603 593 e-mail: deutsche-info@armstrong.com www.armstrong-decken.de www.armstrong-decken.at www.armstrong.ch Armstrong Metalldecken AG Breitfeldstrasse 8 9015 st. Gallen Switzerland Tel.: +41 (0) 71 313 63 63 Fax: +41 (0) 71 313 64 00 Zentralschweiz Armstrong Metalldecken AG Buro / Lager Zentralschweiz Grossweid 9 CH-6026 rain Tel.: +41 (0) 41 921 63 63 Fax: +41 (0) 41 921 63 80 Suisse Romande Armstrong Plafonds Métalliques SA Bureau Suisse Romande 3, Rue Gustave-Monynier CH-1202 Genève Tel.: +41 (0) 22 731 60 70 Fax: +41 (0) 22 731 60 74 Austria/Eastern Europe Armstrong Metalldecken GmbH Bundesstrasse 70 A-6830 Rankweil Tel.: +43 (0) 55 22 34 44-0 Fax: +43 (0) 55 22 34 44-8 Armstrong Metalldecken GmbH Messendorferstrasse 6 A-8041 Graz Tel.: +43 (0) 31 64 71 584 Fax: +43 (0) 31 64 71 584-10 Spain Armstrong Building Products Oficina de ventas España Immeuble Paryseine 3 Allée de la Seine 94854 Ivry-sur-Seine Francia Tel.: (+ 34) 91 642 04 99 00 800 90 21 03 68 Fax: (+33) 1 4521 04 11 e-mail: info-espana@armstrong.com www.armstrong.es/techos Portugal Armstrong Floor Product Rua de Manuel Assunçao de Falcao, 63 4475-041 Santa Maria de Avioso - Maia Portugal Tel.: (+351) 22 982 81 10 Fax: (+351) 22 982 81 19 e-mail: service_portugal@armstrong.com www.armstrong.pt France & French Speaking Africa Armstrong Building Products SAS Bureaux Commerciaux France Immeuble Paryseine 3 Allée de la Seine 94854 Ivry-sur-seine Tel.: 0800 41 36 43 Fax: (+33) 1 45 21 04 11 e-mail: info-france@armstrong.com www.armstrong.fr/plafonds Siège social Armstrong Building Products SAS 67 Rue de Salins Bp 89 25300 Pontarlier France Italy & Greece Armstrong Building Products Ufficio Commerciale Italia Immeuble Paryseine 3 Allée de la Seine 94854 Ivry-sur-Seine Francia Tel.: (+39) 02 66 22 76 50 Fax: (+39) 02 66 20 14 27 e-mail: info-italia@armstrong.com www.armstrong-soffitti.it Netherlands Armstrong Building Products B.V. Verkoopkantoor Nederland Postbus 3803 4800 DV Breda Nederland Tel.: (+31) 076 52 30 200 Fax: (+31) 076 521 04 07 e-mail: benelux-info@armstrong.com www.armstrong.nl/plafonds United Kingdom Armstrong World Industries Ltd Building Products Division Armstrong House 38 Market Square uxbridge UB8 1NG Tel.: 0800 371849 Fax: (+44) 1895 274287 e-mail: sales-support@armstrong.com www.armstrong-ceilings.co.uk Republic of Ireland Armstrong World Industries Ltd. 108 Greenlea Road Terenure Co Dublin 6W Ireland Tel.: 1800 409002 Tel.: (+353) 1 499 1701 Fax: (+353) 1 490 7061 e mail: sales-support@armstrong.com www.armstrong-ceilings.ie MIDDLE EAST / AFRICA / TURKEY Armstrong World Industries Ltd Africa Middle East Turkey Division Armstrong House 38 Market Square Uxbridge UB8 1NG Tel.: (+44) 01895 251122 Fax: (+44) 01895 272928 e-mail: sales-support@armstrong.com www.armstrong.eu Israël: www.armstrong.co.il South Africa: www.armstrong-ceilings.co.za Dubai | United Arab Emirates Armstrong World Industries JLT Office No. 2003, 20th Floor Gold Crest Executive Tower Jumeirah Lakes Towers P.O. Box 73831 Dubai, U.A.E. info-me@armstrong.com www.armstrong.ae Turkiye Armstrong Europa GmbH Turkiye Satış Temsilciliği Sarıyer-Istanbul Turkiye Gsm: +90 533 367 54 89 Fax: +90 212 257 44 78 www.armstrong.com.tr cbalci@armstrong.com CENTRAL EUROPE NORTH (DK/EE/FIN/IS/LT/LV/N/PL/S) Armstrong Building Products BV Sp. z o.o. Oddział w Polsce ul. Domaniewska 37 02-672 Warszawa Poland Tel.: (+48) 0 22 337 86 10/ 86 11 Fax: (+48) 0 22 337 86 12 e-mail: service-ce@armstrong.com Latvia: www.armstrong.lv Lithuania: www.armstrong.lt Norway: www.armstrong.no Poland: www.armstrong.pl Sweden: www.armstrong.se CENTRAL EUROPE SOUTH (AL/BA/BG/CZ/HR/HU/KO/ MD/ME/MK/RO/RS/SK/SI) Armstrong Building Products Lighthouse Building, Jankovcova 1569/2c, 170 00 Praha 7, Czech Republic Tel. : +420 234 700 543 e-mail: service-ce@armstrong.com Czech republic: www.armstrong.cz Hungary: www.armstrong.co.hu Romania: www.armstrong.ro Serbia: www.armstrong.rs Slovakia: www.armstrong.sk Slovenia: www.armstrong.si EASTERN EUROPE CIS Armstrong Moscow GmbH Park Place, office E502 # 113/1, Leninsky Prospekt Moscow 117198 Russia Tel.: (+7) 495 956 5100 Fax: (+7) 495 956 5101 e-mail: info-cis@armstrong.com Russian Federation: www.armstrong.ru Advisory note All photographic and design elements supplied in this brochure do not necessarily reflect any recommendation by any of the companies named in this brochure as to the proper use or recommended methods of installation of suspended ceilings and are supplied only as informative material. For technical reasons in printing, differences may appear between colours printed in this brochure and the actual product. The choice of colours should always be made from a sample of the product. All statements and technical information contained in this brochure, or any publication of the companies named in this brochure, relating to Armstrong ceilings are based on results obtained under laboratory test conditions. It is the responsibility of the user to verify with the seller of the products in writing that such statements and information are appropriate to the specific use intended. Sales of the products and liability of the selling companies are in accordance with the terms and conditions of sale of the selling company. All product specifications are subject to modifications without prior notice.