• Revised • 03/01/14 Manual Control Class 11 - 3RV, SMF, MMS Wiring Diagrams Signaling Contact for Class 11 - 3RV Class 11 - 3RV Typical Wiring Diagrams—Class SMF 3RV1921-1M AC Reversing Manual Starter and Manual Motor Starting Switches T1 L3 L1 T1 L1 T2 L2 T2 L2 T3 L3 T3 L3 REV T1 Reversing Manual Motor Starting Switch 2-Pole, 1-Phase T1 L3 L1 L3 T3 THREE PHASE MOTOR Line Meter L1 to L2 to L3 to T1 to T2 to T3 to L.H. UNIT _ _ _ T1 T2 T3 Pilot Light Leads to _ _ T1 T2 T3 R.H. UNIT L1 L2 L3 _ _ _ T1 T3 Reversing Manual Starter 3-Pole, 3-Phase SINGLE PHASE CAPACITOR OR SPLIT PHASE MOTOR L.H. UNIT LINE AND MOTOR LEADS Line L1 to L2 to _ _ Meter T1 to T4 to T5 to T8 to T1 T3 L1 T2 Furnish Jumper R.H. UNIT L1 L2 _ _ _ _ L3 to _ _ Pilot Light Leads to T8 T4 Motor T2 T1 T3 T1 T5 RUN START 17-168 L1 T1 T2 L2 T2 L2 T3 L3 T3 L3 Motor 2-Pole, 1-Phase with Pilot Lights 3-Pole Reversing Switches LINE AND MOTOR LEADS T1 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog SINGLE PHASE 4-LEAD REPULSION - INDUCTION MOTOR L.H. UNIT LINE AND MOTOR LEADS Line L1 to L2 to _ _ Meter T1 to T4 to T5 to T8 to T2 L3 T3 T1 Furnish Jumper L3 to _ _ Pilot Light Leads to T8 T1 L1 Pilot Lights (if used) 2-SPEED 2-WINDING SINGLE PHASE MOTOR Motor LOW HIGH Pilot Lights (if used) LOW T3 L1 L2 L3 L2 LOW L1 T3 REVERSING SINGLE PHASE 3-LEAD REPULSION-INDUCTION MOTOR Motor L1 HIGH T12 T13 T1 T2 T3 REV (R.H. UNIT) L1 Pilot Light (if used) FWD FWD (L.H. UNIT) COM T1 L1 L3 T3 COM CONTROL PRODUCTS 17 T1 L2 REV T11 L1 FWD AC 2-Speed Manual Motor Starting Switches HIGH NEMA & General Purpose Control Typical Wiring Diagrams—MMS R.H. UNIT L1 L2 _ _ _ _ T2 L1 T2 T5 T4 2-SPEED 2-WINDING WYE CONNECTED 3- PHASE MOTOR 3-Pole, 3-Phase • Revised • 03/01/14 Heavy Duty Motor Starters Class 14 Wiring Diagrams 3-Phase and Single Phase Magnetic Starters WIRING DIAGRAM NEMA 00 - 4 Three Phase Magnetic Starter, Size 00–4 TO PILOT CONTROL DEVICE TO SUPPLY L1 L2 L3 ab Single Phase Magnetic Starter WIRING DIAGRAM IF PROVIDED CONTROL FUSES (OPTIONAL) 1 3 IF PROVIDED V M B W 1 A T1 2 T2 ESP200 95 96 A3+ A4- XF T3 C 3 V W M 96 1 B T2 T1 2 X1 XF A1 ESP200 A3 95 96 97 98 A3+ A4- H2 C SEC 97 98 H3 X1 H2 SEC T1 MAY BE GROUNDED BY CUSTOMER 3 PHASE MAGNETIC STARTER SIZE 00 - 4 WIRING DIAGRAM NEMA Three Phase Magnetic Starter with DC Coil, Sizes 00–400 - 4 TO PILOT CONTROL DEVICE SEC FUSE H4 H3 X2 H1 MOTOR CONTROL TRANSFORMER (OPTIONAL) A SEC FUSE H4 CONTROL FUSES (OPTIONAL) 1 CONTROL TRANSFORMER (OPTIONAL) 96 NEMA 00 - 4 TO SUPPLY L1 L2 MAY BE GROUNDED BY CUSTOMER SINGLE PHASE MAGNETIC STARTER Solid State Overload 3-Phase Sizes SIZE 00 - 45-8 INCOMING LINE POWER WIRING: USE 75°C COPPER WIRE ONLY. TO SUPPLY L1 L2 L3 H1 T2 MOTOR X2 SIZE CT RATIO 5 300:5 6 600:5 7 750:5 8 1200:5 A B C CIRCUIT PROTECTIVE DEVICE (IF USED) 1 3 IF PROVIDED 2 V M T1 B W T2 T3 1 LATE BREAK CONTACT 96 CONTROL TRANSFORMER (OPTIONAL) XF C ESP200 X1 2CT "A" L1/1 SEC FUSE H4 X1 3 H2 H3 L2 A1 L3 "C " A2 REMOVE WIRE " C " IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. CONTACTOR M 2 SEC 95 96 97 98 A3+ A4- NOTE A X2 "B " CURRENT TRANSFORMER H1 (WHEN USED, SEE TABLE) RELAY 1CT MOTOR a Warning: The ESP200 Starter and Single Phase Motor must be wired as shown above. For L1, L2 do not use the middle terminal or hole. X1 95 O.L. 96 T1 T2 T3 NOTES: A: 2CT IS LOCATED ON THE LINE SIDE OF CONTACTOR ON SIZE 7 STARTERS ONLY. Ambient Compensated 3-Phase Sizes 00-2 1/2 LOAD Ambient Compensated 3-Phase Sizes 3-4 b Full Load Amps (FLA): Adjustment of the ESP200 solid state overload relay accommodates the single phase motor. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-169 CONTROL PRODUCTS Ambient Compensated Single Phase Sizes 00-2 1/2 (IF USED) 3CT X1 17 THREE PHASE MAGNETIC STARTER WITH D.C. COIL 2CT X1 MAY BE GROUNDED BY CUSTOMER NEMA & General Purpose Control CONTROL FUSES (OPTIONAL) • Revised • 03/01/14 Combination Heavy Duty Starters Class 17, 18 Wiring Diagrams 3-Phase WIRING DIAGRAM NEMA 00 - 4 Size 00–4 a TO PILOT CONTROL DEVICE TO SUPPLY L1 L2 L3 CONTROL FUSES (OPTIONAL) 1 3 V IF PROVIDED M B W 1 CONTROL TRANSFORMER (OPTIONAL) 96 A T1 2 95 96 T2 ESP200 A3+ A4- XF T3 C SEC FUSE H4 X1 H2 SEC 97 98 H3 X2 H1 MOTOR MAY BE GROUNDED BY CUSTOMER NEMA & General Purpose Control 3 PHASE MAGNETIC STARTER SIZE 00 - 4 Size 5–8 b SIZE CT RATIO 5 300:5 6 600:5 7 750:5 8 1200:5 CONTROL PRODUCTS 17 “C” aR emove wire “C” if control transformer is used. For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse line terminals. 17-170 b Remove wire “C” if the contactor coil is to operate on a voltage other than line voltage or in a separate control source. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog O.L. RELAY CURRENT TRANSFORMER (SEE TABLE) • Revised • 03/01/14 REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. Reversing Heavy Duty Starters MOTOR Class 22 Wiring Diagrams 3-Phase Ambient Compensated Overload Bimetal Overload Sizes 0-1 3/4 Bimetal Overload Sizes 2-2 1/2 Bimetal Overload Sizes 3-4 Single Phase Ambient Compensated Overload 3-Wire, 2-Pole Sizes 0-1 3/4 NEMA & General Purpose Control 17 CONTROL PRODUCTS Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-171 • Revised • 03/01/14 Reversing Heavy Duty Starters Class 22 Wiring Diagrams 3-Phase Solid State Overload 3-Phase Reversing Magnetic Starter 3 WIRING ⁄4 DIAGRAM Sizes 00–1 3-Phase Reversing Magnetic Starter Sizes 2–4DIAGRAM WIRING NEMA 00 - 1 3 4 NEMA 2 - 4 TO SUPPLY TO SUPPLY L3 L1 L2 L3 L2 L1 CONTROL FUSES (OPTIONAL) 3 5 V FOR 7 W 6 1 V REV W CONTROL FUSES (OPTIONAL) 4 ESP200 A 95 96 97 98 A3+ A4- XF B C SEC FUSE H4 2 7 H3 4 6 XF C B A MAY BE GROUNDED BY CUSTOMER X2 MOTOR 3 PHASE REVERSING MAGNETIC STARTER TO SUPPLY L2 X2 H1 ESP200 MAGNETIC STARTER L1 X1 H2 SEC 95 96 97 98 A3+ A4- MAY BE GROUNDED BY CUSTOMER Solid State Overload 3 PHASE REVERSING Sizes 5–6 SEC FUSE H4 H3 H1 T1 MOTOR T3 NEMA & General Purpose Control 96 CONTROL TRANSFORMER (OPTIONAL) 1 W REV T3 T2 T1 V X1 SEC T2 W FOR H2 T3 T2 T1 V CONTROL TRANSFORMER (OPTIONAL) 96 1 2 5 3 1 L3 "REV" CONTACTOR "FWD" "FWD" CONTACTOR CONTRACTOR MECHANICAL INTERLOCK O.L. RELAY 17 CURRENT TRANSFORMER (SEE TABLE) CONTROL PRODUCTS REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. MOTOR 3-Phase Reversing Magnetic Starter with DC Coil,WIRING SizesDIAGRAM 00–13⁄4 3-Phase Reversing Magnetic Starter with DC Coil, Sizes 2–4 NEMA 00 - 1 3 4 L1 1 3 7 V FOR W 5 V REV T3 T2 T1 W 6 96 CONTROL TRANSFORMER (OPTIONAL) SEC FUSE XF H4 X1 4 ESP200 95 96 97 98 A3+ A4- LATE BREAK B C H2 SEC T2 T1 MOTOR L2 H3 5 V W FOR V 2 7 L.B. XF T3 T2 T1 MOTOR 1 96 C SEC FUSE H4 H2 H3 T3 CONTROL FUSES (OPTIONAL) B Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 4 6 ESP200 T2 W L.B. X2 3 PHASE REVERSING MAGNETIC STARTER W/DC COIL REV 95 96 97 98 A3+ A4- T1 H1 T3 MAY BE GROUNDED BY CUSTOMER 17-172 NEMA 2 - 4 L3 3 CONTROL FUSES (OPTIONAL) 1 2 WIRING DIAGRAM TO SUPPLY TO SUPPLY L2 L3 L1 X1 CONTROL TRANSFORMER SEC (OPTIONAL) X2 H1 MAY BE GROUNDED BY CUSTOMER 3 PHASE REVERSING MAGNETIC STARTER W/DC COIL • Revised • 03/01/14 Combination Reversing Heavy Duty Starters Class 25, 26 Wiring Diagrams 3-Phase 3-Phase Reversing Magnetic Starter 3 WIRING00–1 DIAGRAM NEMA 00 - 1 3 4 ⁄4 Sizes 3-Phase Reversing Magnetic Starter Sizes 2–4 NEMA 2 - 4 WIRING DIAGRAM TO SUPPLY L3 L1 L2 TO SUPPLY L3 L2 L1 CONTROL FUSES (OPTIONAL) 3 5 V FOR 7 W 6 1 V REV W CONTROL FUSES (OPTIONAL) 4 ESP200 95 96 97 98 A3+ A4- A XF B C T1 T2 T3 V CONTROL TRANSFORMER (OPTIONAL) 96 1 2 5 3 1 T1 SEC FUSE H4 T2 V 2 7 REV 4 6 XF C T3 A B X2 X2 MAY BE GROUNDED BY CUSTOMER MOTOR 3 PHASE REVERSING MAGNETIC STARTER 3 PHASE REVERSING MAGNETIC STARTER NEMA & General Purpose Control TO SUPPLY L2 X1 H2 H1 ESP200 95 96 97 98 A3+ A4- MAY BE GROUNDED BY CUSTOMER L1 SEC FUSE H4 SEC H1 T1 MOTOR T3 96 CONTROL TRANSFORMER (OPTIONAL) 1 W H3 H2 H3 W X1 SEC T2 FOR Size 5–6 L3 "REV" CONTACTOR "FWD" "FWD" CONTACTOR CONTRACTOR MECHANICAL 17 INTERLOCK CONTROL PRODUCTS O.L. RELAY CURRENT TRANSFORMER (SEE TABLE) REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. MOTOR Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-173 • Revised • 03/01/14 Two Speed Heavy Duty Starters Class 30 & 32 Non-Combination and Combination Starters Wiring Diagrams 1 Winding Constant Horsepower Size 0–13/4 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 DISCONNECT or CIRCUIT BREAKER DISCONNECT or CIRCUIT BREAKER HIGH OL HIGH HIGH LOW HIGH LOW 5 T6 T4 T4 T2 LOW T3 V LOW W T1 T5 6 5 95 2 T2 CONSTANT HORSEPOWER MOTOR 3 6 LOW HIGH 5 4 B 8 7 73 V LOW W 1 96 CONTROL TRANSFORMER (OPTIONAL) V HIGH W T6 7 HIGH LOW 2 ESP200 95 96 97 98 A OVERLOAD A3+ RELAY A495 96 HIGH C 1 96 2 4 ALL OL'S 96 6 CONTROL FUSES (OPTIONAL) 1 V HIGH W 4 T3 T1 OL LOW LOW B A 3 8 T5 LOW A NEMA 00 - 1 3 4 WIRING DIAGRAM WIRING DIAGRAM SUPPLY TOTOSUPPLY L1L1 L2L2 L3L3 L3 8 T1 T1 T2 T2 X1 OVERLOAD RELAY A3+ A495 96 T3 T3 SEC FUSE CONTROL FUSES XF (OPTIONAL) H4 ESP200 95 96 97 98 T6 T6 T4 T4 C H2 CONTROL TRANSFORMER SEC (OPTIONAL) SEC FUSE H3 X2 XF H4 X1 T5 T5 H1 LOW H2 T1 T2T1 T3T2 T4T3 MOTOR M T5T4 T6T5 POSITION L1 L2 L3 TOGETHER LOW SPEED T1 T2 T3 T4 T5 T6 HIGH SPEED T6 T4 T5 SEC MAY BE GROUNDED BY X2 CUSTOMER H3 H1 T6 2 SPEED 3 PHASE 1 WINDING CONSTANT HORSEPOWER 1 Winding Constant Horsepower Size 2–4 NEMA 2 - 4 WIRING DIAGRAM NEMA & General Purpose Control TO SUPPLY L1 L2 L3 5 1 V LOW W CONTROL FUSES (OPTIONAL) 3 6 VHIGHW V L W 4 2 6 96 T4 T5 XF ESP200 95 96 97 98 A3+ A4- T2 1 CONTROL TRANSFORMER (OPTIONAL) T6 A ESP200 95 96 97 98 T1 B 7 C A3+ A4- SEC FUSE H4 X1 H2 SEC T3 H3 X2 H1 CONTROL PRODUCTS 17 T1 T2 T3 T4 T5 T6 MAY BE GROUNDED BY CUSTOMER MOTOR 2 SPEED 3 PHASE 1 WINDING CONSTANT HORSEPOWER 1 Winding Constant or Variable Torque Size 0–13/4 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 DISCONNECT or CIRCUIT BREAKER LOW LOW HIGH HIGH HIGH 96 T3 T4 HIGH ALL OL'S T2 T6 OL HIGH HIGH A T1 T5 95 2 4 LOW HIGH 5 T3 T1 T2 T5 T6 VARIABLE TORQUE MOTOR 3 HIGH 6 5 LOW 7 3 8 T1 T2 T5 T6 CONSTANT TORQUE MOTOR T4 T3 NEMA 00 - 1 3 4 DISCONNECT or CIRCUIT BREAKER T4 OL LOW LOW WIRING DIAGRAM WIRING DIAGRAM TO SUPPLY TO SUPPLY L1 L1 L2 L2 L3 L3 L3 LOW V HIGH W 7 73 V HIGH W 4 8 HIGH POSITION L1 L2 L3 TOGETHER LOW SPEED T1 T2 T3 HIGH SPEED T6 T4 T5 T1 T2 T3 2 ESP200 95 96 RELAY 97 98 OVERLOAD 95 CONTROL FUSES (OPTIONAL) V LOW W 4 6 5 6 B A 1 A A3+ A496 B 8 V LOW W C 1 96 2 ESP200 95 96 97 98 OVERLOAD RELAY 95 A3+ A4- 96 T1 T1T2 T2 T6T6 T4T4 T5T5 T1 T1 T2 T2 T3 T3 MOTOR T4 T4 M T5 T5 T6 T6 1 T3 T3 96 CONTROL TRANSFORMER (OPTIONAL) CONTROL SEC FUSESFUSE (OPTIONAL) XF H4 X1 C H2TRANSFORMER CONTROL (OPTIONAL) SEC SEC FUSE H3 XF X2 H4 X1 H2 H1 SEC MAY BE H3 X2 GROUNDED BY H1 CUSTOMER 2 SPEED 3 PHASE 1 WINDING CONSTANT OR VARIABLE TORQUE Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used. 17-174 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog • Revised • 03/01/14 Two Speed Heavy Duty Starters Class 30 & 32 Non-Combination and Combination Starters Wiring Diagrams 1 Winding Constant or Variable Torque Size 2–4 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 L3 DISCONNECT or CIRCUIT BREAKER LOW H H LOW H HIGH T3 6 LOW 5 LOW 7 4 6 HIGH H LOW 6 V LOW W ESP200 95 96 97 98 A3+ A4- A3+ A4- T6 HIGH POSITION L1 L2 L3 TOGETHER LOW SPEED T1 T2 T3 HIGH SPEED T6 T4 T5 T1 T2 T3 T4 96 CONTROL TRANSFORMER (OPTIONAL) T1 ESP200 95 96 97 98 H 1 7 A 8 B V H W T1 T2 2T3 3 OVERLOAD RELAY 95 96 T2 T5 T6 VARIABLE TORQUE MOTOR 3 HIGH H 2 4 CONTROL FUSES (OPTIONAL) 3 8 V H W 1 2 7 V HIGHW T1 T3 5 V LO W T4 T5 95 1 T2 T5 T6 CONSTANT TORQUE MOTOR ALL OL'S 96 T1 T3 T2 T4 HIGH A B T1 T6 OL HIGH HIGH NEMA 2 - 4 WIRING DIAGRAM WIRING DIAGRAM CIRCUIT BREAKER T4 OL LOW LOW A TO SUPPLY L1 L2 L3 TO SUPPLY L1 L2 L3 DISCONNECT or T2 T3 SEC FUSE XF C H4 X1 H2 SEC T5 H3 5 V HI W 4 T6 T4 X2 H1 T5 T1 T2 T3 T4 T5 T6 OVERLOAD RELAY 95 96 CONTROL FUSES (OPTIONAL) 1 96 C MOTOR H2 T1 T2 T3 T4 T5 T6 MAY BE GROUNDED BY CUSTOMER SEC FUSE XF H4 X1 SEC D68784002 NEMA & General Purpose Control H3 2 SPEED 3 PHASE 1X2 WINDING MOTOR H1 CONSTANT OR VARIABLE TORQUE CONTROL TRANSFORMER (OPTIONAL) 2 Winding Constant Horsepower & 2 Winding Constant or Variable Torque Size 0–4 L3 LOW T1 OL LOW T3 HIGH HIGH POSITION L1 L2 L3 LOW SPEED T1 T2 T3 HIGH SPEED T11 T12 T13 T1 V HI 2 T3 T12 W B 4 8 5 6 V HIGH W 37 V LOW W T12 T13 ALL OL'S 95 V LO W 1 96 T11 OL HIGH HIGH 96 CONTROL FUSES (OPTIONAL) B A 1 8 T2 LOW 5 3 2 6 T1 T2 T3 ESP200 OVERLOAD RELAY 95 96 97 98 95 96 T11 T13 TWO WINDING MOTOR 7 A A3+ A4- 5 LOW 6 4 HIGH 3 HIGH 7 2 LOW HIGH 4 T2 CONTROL FUSES XF (OPTIONAL) H4 CONTROLCTRANSFORMER H2 (OPTIONAL) A3+ A4- T3 LOW T11 T1 T2 T1 T3 T11 T2 T12 T3 T13 T11 T12 T13 T12 T13 XF SEC FUSE H3 H4 X1 H2 M MOTOR CONTROL TRANSFORMER (OPTIONAL) SEC FUSE C 1 96 T11 T12 T13 ESP200 OVERLOAD RELAY 95 96 97 98 95 96 8 T1 CONTROL PRODUCTS LOW T2 17 WIRING DIAGRAM DISCONNECT or CIRCUIT BREAKER DISCONNECT or CIRCUIT BREAKER A L2 TO SUPPLY L1 L2 L3 NEMA 2 - 4 WIRING DIAGRAM TO SUPPLY L1 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 L3 H3 H1 SEC X1 SEC X2 H1 X2 MAY BE GROUNDED BY CUSTOMER 2 SPEED 3 PHASE 2 WINDING SEPARATE WINDING D68786001 Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-175 Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams CONTROL PRODUCTS 17 NEMA & General Purpose Control Part Winding EMT 17-176 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog • Revised • 03/01/14 • Revised • 03/01/14 Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams Auto Transformer TO SUPPLY L1 L2 L3 SEK SES SAW LMB SEK SES SAW LMB SEK SES SAW LMB OPTIONAL DISCONNECT OR CIRCUIT BREAKER OL 1S 3L1 0% 50% 1L1 R 65% 1CT 80% 2S L2 L3 100% L1 T1 2L1 OL 0% 50% 65% 80% R 1S 3L2 1L2 100% 2S 2CT * T2 2L2 FOR MOTOR HP SEE CONTROLLER NAMEPLATE MOTOR OL 4FU 71 MR 73 1S 0% 50% 65% 3L3 80% R FOR STARTER SIZES 1-4, 1CT-3CT ARE NOT USED. L1 1L3 100% 2S 3CT T3 2L3 1S 74 (A1) R 75 (A2) 2S 76 MR 5FU 72 L2 2S CR1 77 L1 79 H1 (A1) H4 MECH INTLK (A2) R 3FU L2 CPT X2 X1 CONNECT VOLTAGE AS SPECIFIED PER NAMEPLATE NOTE E 2 3 3 (A1) MR (A2) 4 (95) OL (96) 17 2 LMB SAW SES SEK 1 X2 TR SUPPLIED AS REQUIRED LMB SAW SES SEK JUMPER 1FU 12 TAS 1 2FU 78 * 1S (A2) 1S NEMA & General Purpose Control CR1 (A1) 3 MR TR 6 (A1) CR1 (A2) CONTROL PRODUCTS NOTC CONNECTIONS FOR OPTIONAL DEVICES Note E: Remove jumper if thermal protection switch is provided. HAND * 3 1PB OFF AUTO (A1) (A2) 2PB (A1) START CR2 (A2) 3 2 2PB 1SS HAND 1 2 1 1 * SURGE SUPPRESSOR START STOP 1 OFF * 5 AUTO CONTACT 3 1 RUN/ON/ RUNNING 3 3 1SS * 5 OFF 1 AUTO CONTACT 4 ETM AUTO 4 1LT OL OL TRIPPED 9 X2 MR OFF/STOP 10 X2 1 4LT ON 1SS * 3 1 5LT OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-177 Reduced Voltage Starters & Pump Panels Class 36, 37, 88 CONTROL PRODUCTS 17 NEMA & General Purpose Control Wye Delta (Open Transition) 17-178 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog • Revised • 03/01/14 Wiring Diagrams Reduced Voltage Starters & Pump Panels Class 36, 37, 88 • Revised • 03/01/14 Wiring Diagrams Wye Delta (Closed Transition) NEMA & General Purpose Control 17 CONTROL PRODUCTS Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-179 Heavy Duty Contactors and Reversing Contactors Class 40, 43 • Revised • 03/01/14 Wiring Diagrams 3-Phase Magnetic Contactors and Reversing Contactors 3-Phase Contactors—Size 00–4 3-Phase Reversing Contactors—Size 00–4 3-Phase Contactors—Size 5, 6 3-Phase Reversing Contactors—Size 5, 6 TO SUPPLY L1 L2 L3 "REV" CONTACTOR "FWD" "FWD" CONTACTOR CONTRACTOR MECHANICAL NEMA & General Purpose Control INTERLOCK RELAY CURRENT TRANSFORMER REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. CONTROL PRODUCTS 17 LOAD Single Phase Magnetic Contactors and Reversing Contactors Single Phase Contactors—Size 00–4 17-180 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Single Phase Reversing Contactors—Size 00–1P • Revised • 03/01/14 Duplex Heavy Duty Controllers Class 83, 84 Standard Duplex Pump Panel (92) Wiring Diagrams Duplex Panel w/o alternator (95) NEMA & General Purpose Control 17 CONTROL PRODUCTS Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-181 Duplex Heavy Duty Controllers Class 83, 84 CONTROL PRODUCTS 17 NEMA & General Purpose Control Duplex Panel with Relay Alternation (93) 17-182 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog • Revised • 03/01/14 Wiring Diagrams Duplex Panel with Lead Pump Transfer Switch (94) Standard & Irrigation Pump Panels Class 87 • Revised • 03/01/14 Wiring Diagrams Standard Class 87 Pump Panel NEMA & General Purpose Control 17 CONTROL PRODUCTS Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-183 • Revised • 03/01/14 Duplex Heavy Duty Controllers Class LC and LE Electrically Held Contactors LEN00D003 (60A 3 Pole) LEN00E003 (100A 3 Pole) LEN00B003 (20A 3 Pole) A1 1 /L1 3 /L2 5 L3 13 A2 2 /T1 4 /T2 6 /T3 14 5 /L3 7 /L4 1 /L1 3 /L2 A1 1/L1 3/L2 5/L3 A2 2/T1 4/T2 6/T3 LEN00F003 (200A 3 Pole) LEN00G003 (300A 3 Pole) LEN00H003 (400A 3 Pole) LEN00B004 (20A 4 Pole) A1 Wiring Diagrams A1 1 /L1 3 /L2 5 /L3 13 21 31 43 A2 2 /T1 4 /T2 6 /T3 14 22 32 44 U A2 2 /T1 4 /T2 6 /T3 8 /T4 LEN00C003 (30A 3 Pole) NEMA & General Purpose Control A1 1 /L1 3 /L2 5 /L3 13 21 LCE00C (30A 2-12 Pole) LINE LOAD 1 2 A2 2 /T1 4 /T2 6 /T3 14 22 3 4 LEN00C004 (30A 4 Pole) 1 /L1 3 /L2 5 /L3 7 /L4 13 21 5 17 A1 CONTROL PRODUCTS 6 A1 A2 COIL A2 2 /T1 4 /T2 6 /T3 8 /T4 14 22 COIL VOLTAGE OPTIONAL AUXILIARY CONTACTS 17-184 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog • Revised • 03/01/14 Duplex Heavy Duty Controllers Class LC and LE Electrically Held Contactors Wiring Diagrams Optional Pilot Devices for Electrically Held Contactor ON and OFF Push buttons L1 FUSE ON ON PB OFF PB * COIL A2 FUSE A1 * L2 REMOTE OFF AUXILIARY CONTACT REMOTE ON AUXILIARY CONTACT OFF ON SS OFF-ON or OFF-AUTO Selector Switch REMOTE DEVICE L1 AUTO OFF * FUSE A2 AUXILIARY CONTACT COIL A1 FUSE * L2 OFF NEMA & General Purpose Control ON OFF-ON-AUTO HAND-OFF-AUTO Selector Switch L1 FUSE * ON REMOTE DEVICE OFF A2 AUTO AUXILIARY CONTACT COIL A1 FUSE * L2 OFF 17 * -- IF USED CONTROL PRODUCTS Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-185 H 4 • Revised • 03/01/14 5 Lighting and Heating Contactors P1 P2 P3 P4 P5 COIL VOLTAGE ON * FUSE RE O AUTO REMOTE DEVICE COIL VOLTAGE P4 A2 3-WIRE CONTROL P5 COIL FUSE OFF ON FUSE A1 * COIL VOLTAGE A2OFF COIL P3 CONTROL VOLTAGE A1 P1 P2 OPTIONAL 'N/C' AUXILIARY CONTACT ON RETURN TO CENTER ELECTRONIC-MODULE NOT USED OPTIONAL "N/O" AUX. CONTACT OFF A1 A2 ELECTRONIC-MODULE * FUSE CONTROL VOLTAGE COIL OFF-ON SELECTOR CONTROL VOLTAGE TABLE A C * "NC" ELECTRONIC-MODULE REFER TO TABLE C FOR CONTROL CONNECTIONS 5 ON & OFF P5 P4 PUSH BUTTONS P3 SWITCH WITH SPRING 4 P1 P2 2-WIRE CONTROL REFER TO TABLE B FOR CONTROL CONNECTIONS SELECTOR SWITCH 3 ON-OFF-AUTO HAND-OFF-AUTO or 2 Wiring Diagrams ELECTRONIC-MODULE (AUTO) CONTROL VOLTAGE LOAD 1 REFER TO TABLE A SS FOR ON 2/3 WIRE CONTROL OPTIONS OFF SELECTOR SWITCH OFF-ON or LINE OFF-AUTO Class LC (converted to mechanically held) TABLE C : OPTIONAL 6 TABLE B : OPTIONAL PILOT DEVICES FOR 2 WIRE CONTROL P1 P2 P3 P4 P5 L ON OPTIONAL "N/O" AUX. CONTACT "NO" AUXILIARY * FUSE * FUSE OFF P5 COIL CONTROL VOLTAGE P4 A1 A2 P3 P4 A2 OFF OFF ELECTRONIC-MODULE P1 P2 ON COIL ON A1"NC" AUXILIARY FUSE * A2 REMOTE DEVICE P1 P2 P3 P4 OFF P5 OFF COIL A2 ON FUSE FUSE A1 OFF AUTO COIL A2 * * ON FUSE A1 * TABLE C : OPTIONAL PILOT DEVICES FOR 3 WIRE CONTROL "NO" AUXILIARY REMOTE OFF OPTIONAL 'N/C' ACT AUXILIARY CONTACT 17-186 P1 REMOTE ON P2 P3 P4 OFF COIL "NC" AUXILIARY A2 REMOTE ON OFF ELECTRONIC-MODULE "NC" AUXILIARY P1 P2 P3 FUSE FUSE A1 ON "NO" AUXILIARY ON P5 P4 A2 P5 ON COIL FUSE A1 FUSE OFF "NO" AUXILIARY ON "NC" AUXILIARY ** * * ELECTRONIC-MODULE P1 P2 OFF P3 P4 A2 OFF P5 COIL OFF ON "NC" AUXILIARY A1 A2 COIL A1 ON FUSE FUSE ** * ON -- IF USED FUSE * -- IF USED Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog COIL VOLTAGE ELECTRONIC-MODULE * COIL VOLTAGE ON OFF FUSE * COIL VOLTAGE "NO" AUXILIARY REMOTE OFF COIL VOLTAGE CONTROL VOLTAGE CONTROL VOLTAGE CONTROL VOLTAGE CONTROL VOLTAGE OFF-ON SELECTOR OFF-ON SELECTOR ON & OFF ON & OFF SWITCH WITH SPRING SWITCH WITH SPRING PUSH BUTTONS PUSH BUTTONS RETURN TO CENTER RETURN TO CENTER OPTIONAL 'N/C' OPTIONAL 'N/C' AUXILIARY CONTACT AUXILIARY CONTACT ELECTRONIC-MODULE TABLE C : OPTIONAL PILOT DEVICES FOR 3 WIRE P1 P2CONTROL P3 P4 P5 OFF COIL VOLTAGE * ELECTRONIC-MODULE P1 P2 P3 P4 P5 FUSE OFF A2 COIL VOLTAGE REMOTE DEVICE COIL ON * FUSE P5 COIL VOLTAGE P3 FUSE A1 * FUSE ELECTRONIC-MODULE P1 P2 A2 * ON COIL "NC" AUXILIARY ELECTRONIC-MODULE ONAUTO P4 P5 COIL VOLTAGE C P5 P4 OFF COIL VOLTAGE CONTROL VOLTAGE A1 P3 OPTIONAL 'N/C' AUXILIARY CONTACT O P1 P2 P5 FUSE REMOTE ON OFF ELECTRONIC-MODULE P4 COIL A1 * ON FUSE * -- IF USED * COIL VOLTAGE COIL VOLTAGE CONTROL VOLTAGE 17 CONTROL PRODUCTS L P3 RETURN TO CENTER A2 COIL ON (AUTO) OFF-ON SELECTOR A1 OFF 3-WIRE CONTROL REFER TO TABLE C FOR CONTROL CONNECTIONS P1 P2 SWITCH WITH SPRING CONTROL CONTROL VOLTAGE VOLTAGE SS P3 ON P1 P2 P3 P4 P5 TABLE B : OPTIONAL PILOT DEVICES FOR 2 WIRE CONTROL NOT USED P2 COIL VOLTAGE OFF "NO" AUXILIARY C ELECTRONIC-MODULE ON (AUTO) OPTIONAL 'N/C' AUXILIARY CONTACT SELECTOR SWITCH LOAD SS P1 OFF COIL VOLTAGE TABLE B : OPTIONAL PILOT DEVICES FOR 2 WIRE CONTROL ELECTRONIC-MODULE ON-OFF-AUTO ON-OFF-AUTO SELECTOR SWITCH SELECTOR SWITCH SELECTOR SWITCH C OPTIONAL "N/O" OFF-ON or AUX. CONTACT OFF-ON or OFF-AUTO OFF-AUTO LOAD OPTIONAL "N/O" HAND-OFF-AUTO or AUX. CONTACT HAND-OFF-AUTO or NEMA & General Purpose Control REFER TO TABLE B FOR CONTROL CONNECTIONS O A2 ELECTRONIC-MODULE CONTROL VOLTAGE ON & OFF TABLE A 2-WIRE CONTROL PUSH BUTTONS REFER TO TABLE A FOR 2/3 WIRE CONTROL OPTIONS A1 REMOTECOIL OFF OPTIONAL 'N/C' AUXILIARY CONTACT TABLE C : OPTIONAL PILOT DEVICES FOR 3 WIRE CONTROL 6 • Revised • 03/01/14 Lighting and Heating Contactors Mechanically Latched 20 Amp, Class CLM ON Wiring Diagrams OFF CONTACTOR CONTROL VOLTAGE L OFF L ON C COMMON OR SEPARATE CONTROL LINES 5 ON 2 CR1 3 CR2 L CR2 CR1 0 CR1 CR2 C ON 0 OFF CONTROL MODULE VOLTAGE OFF 4 TYPICAL OFF-ON SELECTOR SWITCH COIL PILOT LIGHTS REQUIRE (1) EA. CLM4097291 AUXILIARY CONTACT KIT. 3 WIRE CONTROL ACC. 48 ON CONTACTOR CONTROL VOLTAGE HAND OFF AUTO OFF 5 CONTROL MODULE VOLTAGE CR CR 4 3 OFF L CR 3 COIL REMOTE CONTROL 2 CONTROL MODULE VOLTAGE OFF 5 CR2 0 C L CONTACTOR CONTROL VOLTAGE L CR1 CR2 L CR1 0 CR1 C COIL 4 ON ON ON-OFF (FORM 3) CONTROL ACC. 49 2 WIRE CONTROL ACC. 47 CONNECTIONS TO CONTROL MODULES CONTACTOR CONTROL VOLTAGE OFF 5 1 L ON-OFF CR 0 CR C 3 CR 4 COIL ON 2 WIRE CONTROL ACC. 47 CONNECT TO: NOT USED 2 CONT. STATION FOR ACC. 48 & 49 3 CONT. STATION FOR ACC. 47,48 & 49 4 MODULE CONTROL VOLTAGE * 5 CONTACTOR CONTROL VOLTAGE O " CONTACTOR " TERMINAL O ON C NEMA & General Purpose Control CONTROL MODULE VOLTAGE MODULE TERMINAL L " CONTACTOR " TERMINAL C ON * FOR 24 VDC CONTROL MODULES CONNECT TERMINAL 4 TO NEGATIVE (-) 17 CONTROL PRODUCTS Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-187 Lighting and Heating Contactors Mechanically Latched 30-400 Amps, Class CLM • Revised • 03/01/14 Wiring Diagrams Connection Diagram for Common/Separate Control with Momentary Pushbutton or ON-OFF Selector Switch CLMOC, CLMOD, CLMOE, and CLMOF Connection for 2-Wire Control CLMOC, CLMOD, CLMOE, and CLMOF Connection for Hand/Off/Auto Control CLMOC, CLMOD, CLMOE, and CLMOF Mechanically Latched Type CLM 300 and 400 Amp CONTROL PRODUCTS 17 NEMA & General Purpose Control Mechanically Latched, CLM 30–200 Amps Connection Diagram for Common/Separate Control with Momentary Pushbutton or ON-OFF Selector Switch CLMOG and CLMOH Connection for 2-Wire Control CLMOG and CLMOH Control relay is required for 2-wire and Hand/Off/Auto Control, as shown in diagram. 17-188 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Connection for Hand/Off/Auto Control CLMOG and CLMOH • Revised • 03/01/14 Industrial Control Power Transformers Class MT, MTG Voltage Letter Aac When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter Db Wiring Diagrams Voltage Letter B bc When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter E ac Voltage Letter C bc When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter Fa Voltage Letter Ga Voltage Letter H Voltage Letter I When secondary fuse clips are installed, Terminal X1 becomes XF Does not include secondary fuse clips Does not include secondary fuse clips Voltage Letter J bc Voltage Letter L Voltage Letter Ma CONTROL PRODUCTS When secondary fuse clips are installed, Terminal X3 becomes XF Does not include secondary fuse clips H1 a b c Includes secondary fuse clips on sizes 50-750VA Includes secondary fuse clips on sizes 50-500VA Secondary fuse clips are not included on MTG transformers. X2 Voltage Letter P 380V 24V NEMA & General Purpose Control When secondary fuse clips are installed, Terminal X1 becomes XF 17 When secondary fuse clips are installed, Terminal X1 becomes XF When secondary fuse clips are installed, Terminal X1 becomes XF When secondary fuse clips are installed, Terminal X1 becomes XF H2 X1 Does not include secondary fuse clips Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-189