ul applications IeC applications

advertisement
UL Applications
Comprehensive, UL 1449
3rd Edition recognized
surge protection solutions
for North American AC/DC
applications.
Available March 15, 2011
IEC Applications
High performance surge
protection solutions for
Class 1 and Class 2
DIN-rail products for
global markets.
Available October 15, 2010
prevent a shocking disaster — see how inside.
www.cooperbussmann.com/surge • 636-527-3877
Reorder # 3166
1010
Surge PROTECTION Made Simple.™
Surge Protection Made Simple.™
Cooper Bussmann SPD DIN-rail solutions are
color-coded for each application to prevent
misapplication, avoid shocking disasters, ensure
system reliability and protect your investment.
PV
Wind
Photovoltaic
Telecom
UL
IEC
Superior, true UL 1449
3rd Edition recognized
Surge Protective Devices
(SPD) for photovoltaic (PV)
applications.
Available October 15, 2010
Wind
Advanced, easy-to-use
surge and lightning
protection products for
wind power applications.
Available January 17, 2011
Telecom
Efficient and reliable
network protection
for Telecom and low
voltage applications.
Available January 17, 2011
Surge Protection Made Simple™
Photovoltaic Applications
The Only, True UL 1449 3rd Edition
Recognized SPD to Protect Your
PV Investment from Damaging
Surges and Overvoltages
• Modular DIN-rail design with color-coding & rejection
feature makes it easy to identify, install & maintain.
• Built-in overcurrent protection eliminates the need for
any additional fuse installation and wiring.
• easyID™ Visual indication and optional remote
contact signaling make status monitoring simple.
• Patented, fast-acting Short-Circuit Interrupting (SCI)
technology responds efficiently to overvoltage conditions.
See data sheet #2055 • www.cooperbussmann.com/surge
The Need for Surge Protection
Base & Module Number System
The unique nature of PV installations make them
vulnerable to overvolatges and surges from lightning
strikes and static discharges.
BSP
Number of Poles
System DC Voltage
- 600 = up to 600Vdc
- 1000 = up to 1000Vdc
- 1200 = up to 1200Vdc
System Type
- YPV = PV System in “Y” configuration
Optional Remote Contact Signaling
- R = Includes remote switch option
- Blank = No remote switch option
The Cooper Bussmann PV Surge Suppression systems
provide standard easyID™ visual indication and remote
contact signaling to keep system maintainers apprised
of the protection level being delivered.
Safe and Simple
•IP20 Finger-safe construction and suppressor
rejection feature make it easy to know the suppressor
system is installed and properly operating to protect
your PV system investment.
•Simply specify the system voltage and whether the
remote contact signaling is desired.
•Five year limited warranty.*
Complete Line of Surge Protection Solutions
Wind
Telecom
UL
600 YPV R
Technology
- H = Hybrid
In any PV system, it is vital that surge suppressor
elements that are subject to wear, are easily monitored
for performance.
PV
3
Product Series
These surges need to be intercepted before they take
down the entire system by damaging the PV arrays,
charge controller/inverter and combiner boxes.
Cooper Bussmann offers surge protection products for
UL, IEC, wind power and telecom applications.
H
Replacement Module Number System
BP
H 300
YPV
Product Series
Technology
- M = MOV
- H = Hybrid
MCOV
- 300 = 300Vdc (for 600V systems)
- 500 = 500Vdc (for 1000V systems)
- 600 = 600Vdc (for 1200V systems)
System Type
- YPV = PV System in “Y” configuration
IEC
Ordering Information
Maximum continuous operating voltage for PV applications [UCPV]
Catalog Numbers:
Without Remote Signaling
(Base + Modules)
With Remote Signaling
Replacement Modules:
Outer (2)
Center (1)
Typical Application Schematics
600Vdc
BSPH3600YPV
BSPH3600YPVR
BPH300YPV
BPM300YPV
1000Vdc
BSPH31000YPV
BSPH31000YPVR
BPH500YPV
BPM500YPV
Common
Common
Equipment
Grounding
Conductor
Equipment
Grounding
Conductor
Application A
600, 1000 & 1200Vdc systems
* See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
©2010 Cooper Bussmann
w w w. c o o p e r b u s s m a n n . c o m
Reorder # 3164
1010
5M
Printed in USA
Application B
600Vdc systems only
1200Vdc
BSPH31200YPV
BSPH31200YPVR
BPH600YPV
BPM600YPV
Surge Protection Made Simple™
Photovoltaic Applications
Modular DIN Rail SPD Solutions
Description
The Cooper Bussmann® multi-pole, modular Surge Protective Device
(SPD) (with three-step DC switching device) features easyID™ visual
indication and optional remote contact signaling (floating changeover
contact) for use in PV systems.
These complete surge protective devices are suitable for all
PV systems in accordance with UL 1449 3rd Edition and
IEC 60364-7-712. Includes a five year limited warranty.
These prewired solutions consist of a base and locking modules that
feature a combined disconnection and short-circuiting (shunting)
device with safe electrical isolation to prevent fire damage due to DC
arcs. An integrated DC fuse allows safe module replacement without
arc formation.
In case of insulation faults in the generator circuit, a reliable and
tested fault-resistant Wye circuit prevents damage to the surge
protective devices.
Dimensions - mm
Module Circuit Diagrams
www.cooperbussmann.com/surge
0910
BU-SB09723
Page 1 of 2
Data Sheet 2055
Ordering Information
Max. System Voltage
Catalog Numbers:
(Base + Modules)
Replacement Modules:
Without Remote Signaling
With Remote Signaling
Outer (2)
Center (1)
600Vdc
BSPH3600YPV
BSPH3600YPVR
BPH300YPV
BPM300YPV
1000Vdc
BSPH31000YPV
BSPH31000YPVR
BPH500YPV
BPM500YPV
1200Vdc
BSPH31200YPV
BSPH31200YPVR
BPH600YPV
BPM600YPV
Specifications
Maximum continuous operating voltage for PV applications [UCPV]
MCOV*
Total Discharge Current (8/20 µs) [Itotal]
Voltage Protection Level [UP]
Voltage Protection Level at 5kA [UP]
Integrated Fuse Breaking Capacity/Interrupting Rating
Technology
Operating Temperature Range [TU]
Nominal Discharge Current (8/20 µs) [(DC+/DC-) --> PE] [In]
Max. Discharge Current (8/20 µs) [(DC+/DC-) --> PE] [Imax]
Response Time [tA]
Operating State/Fault Indication
Conductor Ratings and Cross-Sectional Area: Minimum
Maximum
Mounting
Enclosure Material
Degree of Protection
Capacity
Standards Information:
UL
IEC
Product Warranty
600V
1000V
1200V
600Vdc
1000Vdc
1200Vdc
40kA
40kA
30kA
<
_2.5kV
<
_4.0kV
<
_4.5kV
<
_2.0kV
<
_3.5kV
<
_4.0kV
30kA/1000Vdc
30kA/1000Vdc
30kA/1200Vdc
Short-Circuit Interruption (SCI) Overcurrent Protection
-40°C to +80°C
12.5kA
25kA
<
_25ns
Green (good)/Red (replace)
60/75°C 1.5mm2/14AWG Solid/Flexible
60/75°C 35mm2/2AWG Stranded/25mm2/4AWG Flexible
35mm DIN Rail per EN 60715
UL 94V0 Thermoplastic
IP20
3 Modules, DIN 43880
UL 1449 3rd Edition (Type 2)**
IEC 61643-11 Type 2, IEC 61643-1 Class II
Five Years***
Remote Contact Signaling
Remote Contact Signaling Type
AC Switching Capacity (Volts/Amps)
DC Switching Capacity (Volts/Amps)
Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals
Ordering Information
Changeover Contact
250V/0.1A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75°C Max. 1.5mm2/14AWG Solid/Flexible
Order from Catalog Numbers Above
* MCOV Between two conductors.
** Does not apply to 1200Vdc.
*** See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
Typical Application Schematics
Replacement Modules
System
Voltage
600Vdc
Left
BPH300YPV BPH500YPV BPH600YPV
1000Vdc
1200Vdc
Center
BPM300YPV BPM500YPV BPM600YPV
Right
BPH300YPV BPH500YPV BPH600YPV
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information
contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
© 2010 Cooper Bussmann
www.cooperbussmann.com
0910
BU-SB09723
Page 2 of 2
Data Sheet 2055
Surge Protection Made Simple™
Wind Power Applications
Advanced, Easy-to-Use Surge &
Lightning Protection Products
for Wind Power Systems
• Modular DIN-rail design with color-coding and
rejection feature makes it easy to identify, install and
maintain.
• High surge discharge capacity due to heavy-duty zinc
oxide varistor and spark-gap technology.
• easyID™ Visual indication and optional remote
contact signaling make status monitoring simple.
• Vibration and shock resistant according to
EN 60068-2 standards.
• Wide range of IEC Class I and Class II SPD
covering all the major markets around the world.
See data sheet #2091 to 2095 • www.cooperbussmann.com/Surge
The Need for Surge Protection
The unique nature of Wind Power installations make
them vulnerable to overvoltages and surges from
lightning strikes and static discharges.
These surges need to be intercepted before they take
down the entire system by damaging the Wind Power
arrays, charge controller/inverter and combiner boxes.
In any Wind Power system, it is vital that surge
suppressor elements that are subject to wear, are easily
monitored for performance.
The Cooper Bussmann Wind Power Surge Suppression
systems provide standard easyID™ visual indication
and remote contact signaling to keep system
maintainers apprised of the protection level being
delivered.
Safe and Simple
•IP20 Finger-safe construction and suppressor
rejection feature make it easy to know the suppressor
system is installed and properly operating to protect
your Wind Power system investment.
•Simply specify the system voltage and whether the
remote contact signaling is desired.
•Five year limited warranty.*
Part Number System
BSP X X XXX XXX X
BSP = Product Series
Technology Type
M = MOV
S = Spark-Gap
H = Hybrid
G = GDT
Poles
1 = 1-pole
2 = 2-pole
3 = 3-pole
4 = 4-pole
System Voltage
75 = 75Vac
230 = 230Vac
400 = 400Vac
690 = 690Vac
1000 = 1000Vac
System Type
WE = Wind Power
Optional Remote Contact Signaling
R = Optional contact signaling
Blank = No remote switch option
Complete Line of Surge Protection Solutions
Cooper Bussmann offers surge protection products for
PV, telecom, UL and IEC applications.
easy ID™
Reference product data sheets for specific agency
approval information.
PV
Wind
Telecom
UL
IEC
Ordering Information
TN
TN
TN
TT
TN
TNC
TNC
TNC
TT
1
1
1
1
2
3
3
3
2
75
690
1000
230
230
230
400
690
230
Lightning Arrestors - Wind Power IEC Type 1
Cooper Bussmann
Part Number
Description
BSPS1690WER
690V Combined lightning current and surge arrestor for single-pole TN systems (remote)
BSPS1400WE(R)
400V Combined lightning current and surge arrestor for single-pole TN-C systems (remote)
Surge Arrestors - Wind Power IEC Type 2
BSPM175WE(R)
75V Surge arrestor for single-pole TN systems (remote)
BSPM1690WE(R) 690V Surge arrestor for single-pole TN systems (remote)
BSPM11000WE(R) 1000V Surge arrestor for single-pole TN systems (remote)
BSPG1230WE(R)
230V Surge arrestor for single-pole TT systems (remote)
BSPM2230WE(R) 230V Surge arrestor for 2-pole TN systems (remote)
BSPM3230WE(R) 230V Surge arrestor for 3-pole TNC systems (remote)
BSPM3400WE(R) 400V Surge arrestor for 3-pole TNC systems (remote)
BSPM3690WE(R) 690V Surge arrestor for 3-pole TNC systems (remote)
BSPH2230WE(R)
230V Surge arrestor for 2-pole TT systems (remote)
TT
4
230
BSPH4230WE(R)
230V Surge arrestor for 4-pole TT systems (remote)
TNS
4
230
BSPM4230WE(R)
230V Surge arrestor for 4-pole TNS systems (remote)
Power
System Poles
TN
1
TNC
1
Volts
690
400
* See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
© 2 0 11 C o o p e r B u s s m a n n
w w w. c o o p e r b u s s m a n n . c o m
Reorder # 3176 0311
Modules
N/A
N/A
BPM75WE
BPM750WE
N/A
BPG255NPEWE
BPM275WE
BPM275WE
BPM440WE
BPM750WE
BPM275WE,
BPSNPEWE
BPM275WE,
BPSNPEWE
BPM275WE
Surge Protection Made Simple™
IEC Applications
High Performance Lightning &
Surge Protection Products for All
IEC Applications
• Vibration and shock resistant according to
EN 60068-2 standards.
• easyID™ Visual indication and optional remote
contact signaling make status monitoring simple.
• High surge discharge capacity due to heavy-duty zinc
oxide varistor and spark-gap technology.
• Wide range of IEC Class l and Class ll SPD
covering all the major markets around the world.
• Modular DIN-rail design with color-coding and
rejection feature makes it easy to identify, install and
maintain.
See data sheets #1163 to 1169 • www.cooperbussmann.com/surge
The Need for Surge Protection
Today’s world is full of electronic products and devices
that are susceptible to damage from overvoltage
surges.
Base & Module Number System
BSP X X
Whether the cause is static discharge or lightning,
overvoltage surges can quickly destroy consumer
electronics or sophisticated electronic packages used
in industrial and commercial applications.
Poles
1 = 1-pole
2 = 2-pole
Safe and Simple
System Type
IT = IT system
TN = TN system
TNC = TNC system
•IP20 Finger-safe construction.
•Suppressor rejection feature make it easy to know the
suppressor system is installed and properly operating
to protect your IEC system investment.
3 = 3-pole
4 = 4-pole
TNS = TNS system
TT = TT system
Optional Remote Contact Signaling
R = Optional contact signaling
Blank = No remote switch option
•Simple selection of system voltage and remote
contact signaling option.
Complete Line of Surge Protection Solutions
X
System Voltage
230 = 230Vac
320 - 320Vac - Specific to India
400 = 400Vac - Specific to China
440 = 440Vac
Surge protection products from Cooper Bussmann help
assure power quality that’s free from damaging surges
and overvoltage conditions.
•Five year limited warranty.*
XXX XXX
BSP = Product Series
Technology Type
M = MOV
H = Hybrid
S = Spark-Gap
G = GDT
Replacement Module Number System
BP
X
XXX
BP = Product Series
Technology
M = MOV
S = Spark-Gap
Cooper Bussmann offers surge protection products for
PV, wind power, telecom and UL, applications.
XXX
H = Hybrid
G = GDT
MCOV
50NPE*, 100NPE*, 255, 275, 320, 385, 440
*NPE = Neutral to Earth
System Type
IEC = All IEC System Types
PV
Wind
Telecom
UL
IEC
Ordering Information
Power
System Poles
TN
2
Volts
230
Lightning Arrestors - IEC Class l
Cooper Bussmann
Part Number
Description
BSPS2255TN(R)
230V Combined lightning current and surge arrestor for 2-pole TN systems (remote)
TNC
TNS
TT
3
4
2
230
230
230
BSPS3255TNC(R)
BSPS4255TNS(R)
BSPS2255TT(R)
TT
4
230
BSPS4255TT(R)
TN
TN
TN
TN
TN
TN
TNC
TNS
TT
1
1
1
1
1
2
3
4
2
230
230
320
400
440
230
230
230
230
BSPM1275TN(R)
BSPG1255NPE(R)
BSPM1320TN(R)
BSPM1385TN(R)
BSPM1440TN(R)
BSPM2275TN(R)
BSPM3275TNC(R)
BSPM4275TNS(R)
BSPH2275TT(R)
230V Combined lightning current and surge arrestor for 3-pole TN-C systems (remote)
230V Combined lightning current and surge arrestor for 4-pole TN-S systems (remote)
230V Combined lightning current and surge arrestor for
single-pole 1+1 TT and TN systems (remote)
230/400V Combined lightning current and surge arrestor for
3+1 TT and TN-S systems (remote)
Surge Arrestors - IEC Class ll
230V Surge arrestor for single-pole TN systems (remote)
240V 1-Pole GDT DIN rail SPD for N-PE (remote)
320V Surge arrestor for single-pole TN systems (remote) (India Market 230/400V)
400V Surge arrestor for single-pole TN systems (remote) (Chinese Market 230/400)
440V Surge arrestor for single-pole TNC systems (400/690V) (remote)
230V Surge arrestor for 2-pole TN systems (remote)
230/400V Surge arrestor for 3-pole TNC systems (remote)
230/400V Surge arrestor for 3-pole TNS systems (remote)
230V Surge arrestor for 2-pole phase TT systems (remote)
TT
4
230
BSPH4275TT(R)
230/400V Surge arrestor for 3+1 TT and TN-S systems (remote)
* See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
© 2 0 11 C o o p e r B u s s m a n n
w w w. c o o p e r b u s s m a n n . c o m
Reorder #3167
0111
Printed in USA
Modules
BPS255IEC,
BPS50NPE
BPS255IEC
BPS255IEC
BPS255IEC,
BPS50NPE
BPS255IEC,
BPS100NPE
BPM275IEC
BPG255NPE
BPM320IEC
BPM385IEC
BPM440IEC
BPM275IEC
BPM275IEC
BPM275IEC
BPM275IEC,
BPSNPE
BPM275IEC,
BPSNPE
Download