UL Applications Comprehensive, UL 1449 3rd Edition recognized surge protection solutions for North American AC/DC applications. Available March 15, 2011 IEC Applications High performance surge protection solutions for Class 1 and Class 2 DIN-rail products for global markets. Available October 15, 2010 prevent a shocking disaster — see how inside. www.cooperbussmann.com/surge • 636-527-3877 Reorder # 3166 1010 Surge PROTECTION Made Simple.™ Surge Protection Made Simple.™ Cooper Bussmann SPD DIN-rail solutions are color-coded for each application to prevent misapplication, avoid shocking disasters, ensure system reliability and protect your investment. PV Wind Photovoltaic Telecom UL IEC Superior, true UL 1449 3rd Edition recognized Surge Protective Devices (SPD) for photovoltaic (PV) applications. Available October 15, 2010 Wind Advanced, easy-to-use surge and lightning protection products for wind power applications. Available January 17, 2011 Telecom Efficient and reliable network protection for Telecom and low voltage applications. Available January 17, 2011 Surge Protection Made Simple™ Photovoltaic Applications The Only, True UL 1449 3rd Edition Recognized SPD to Protect Your PV Investment from Damaging Surges and Overvoltages • Modular DIN-rail design with color-coding & rejection feature makes it easy to identify, install & maintain. • Built-in overcurrent protection eliminates the need for any additional fuse installation and wiring. • easyID™ Visual indication and optional remote contact signaling make status monitoring simple. • Patented, fast-acting Short-Circuit Interrupting (SCI) technology responds efficiently to overvoltage conditions. See data sheet #2055 • www.cooperbussmann.com/surge The Need for Surge Protection Base & Module Number System The unique nature of PV installations make them vulnerable to overvolatges and surges from lightning strikes and static discharges. BSP Number of Poles System DC Voltage - 600 = up to 600Vdc - 1000 = up to 1000Vdc - 1200 = up to 1200Vdc System Type - YPV = PV System in “Y” configuration Optional Remote Contact Signaling - R = Includes remote switch option - Blank = No remote switch option The Cooper Bussmann PV Surge Suppression systems provide standard easyID™ visual indication and remote contact signaling to keep system maintainers apprised of the protection level being delivered. Safe and Simple •IP20 Finger-safe construction and suppressor rejection feature make it easy to know the suppressor system is installed and properly operating to protect your PV system investment. •Simply specify the system voltage and whether the remote contact signaling is desired. •Five year limited warranty.* Complete Line of Surge Protection Solutions Wind Telecom UL 600 YPV R Technology - H = Hybrid In any PV system, it is vital that surge suppressor elements that are subject to wear, are easily monitored for performance. PV 3 Product Series These surges need to be intercepted before they take down the entire system by damaging the PV arrays, charge controller/inverter and combiner boxes. Cooper Bussmann offers surge protection products for UL, IEC, wind power and telecom applications. H Replacement Module Number System BP H 300 YPV Product Series Technology - M = MOV - H = Hybrid MCOV - 300 = 300Vdc (for 600V systems) - 500 = 500Vdc (for 1000V systems) - 600 = 600Vdc (for 1200V systems) System Type - YPV = PV System in “Y” configuration IEC Ordering Information Maximum continuous operating voltage for PV applications [UCPV] Catalog Numbers: Without Remote Signaling (Base + Modules) With Remote Signaling Replacement Modules: Outer (2) Center (1) Typical Application Schematics 600Vdc BSPH3600YPV BSPH3600YPVR BPH300YPV BPM300YPV 1000Vdc BSPH31000YPV BSPH31000YPVR BPH500YPV BPM500YPV Common Common Equipment Grounding Conductor Equipment Grounding Conductor Application A 600, 1000 & 1200Vdc systems * See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. ©2010 Cooper Bussmann w w w. c o o p e r b u s s m a n n . c o m Reorder # 3164 1010 5M Printed in USA Application B 600Vdc systems only 1200Vdc BSPH31200YPV BSPH31200YPVR BPH600YPV BPM600YPV Surge Protection Made Simple™ Photovoltaic Applications Modular DIN Rail SPD Solutions Description The Cooper Bussmann® multi-pole, modular Surge Protective Device (SPD) (with three-step DC switching device) features easyID™ visual indication and optional remote contact signaling (floating changeover contact) for use in PV systems. These complete surge protective devices are suitable for all PV systems in accordance with UL 1449 3rd Edition and IEC 60364-7-712. Includes a five year limited warranty. These prewired solutions consist of a base and locking modules that feature a combined disconnection and short-circuiting (shunting) device with safe electrical isolation to prevent fire damage due to DC arcs. An integrated DC fuse allows safe module replacement without arc formation. In case of insulation faults in the generator circuit, a reliable and tested fault-resistant Wye circuit prevents damage to the surge protective devices. Dimensions - mm Module Circuit Diagrams www.cooperbussmann.com/surge 0910 BU-SB09723 Page 1 of 2 Data Sheet 2055 Ordering Information Max. System Voltage Catalog Numbers: (Base + Modules) Replacement Modules: Without Remote Signaling With Remote Signaling Outer (2) Center (1) 600Vdc BSPH3600YPV BSPH3600YPVR BPH300YPV BPM300YPV 1000Vdc BSPH31000YPV BSPH31000YPVR BPH500YPV BPM500YPV 1200Vdc BSPH31200YPV BSPH31200YPVR BPH600YPV BPM600YPV Specifications Maximum continuous operating voltage for PV applications [UCPV] MCOV* Total Discharge Current (8/20 µs) [Itotal] Voltage Protection Level [UP] Voltage Protection Level at 5kA [UP] Integrated Fuse Breaking Capacity/Interrupting Rating Technology Operating Temperature Range [TU] Nominal Discharge Current (8/20 µs) [(DC+/DC-) --> PE] [In] Max. Discharge Current (8/20 µs) [(DC+/DC-) --> PE] [Imax] Response Time [tA] Operating State/Fault Indication Conductor Ratings and Cross-Sectional Area: Minimum Maximum Mounting Enclosure Material Degree of Protection Capacity Standards Information: UL IEC Product Warranty 600V 1000V 1200V 600Vdc 1000Vdc 1200Vdc 40kA 40kA 30kA < _2.5kV < _4.0kV < _4.5kV < _2.0kV < _3.5kV < _4.0kV 30kA/1000Vdc 30kA/1000Vdc 30kA/1200Vdc Short-Circuit Interruption (SCI) Overcurrent Protection -40°C to +80°C 12.5kA 25kA < _25ns Green (good)/Red (replace) 60/75°C 1.5mm2/14AWG Solid/Flexible 60/75°C 35mm2/2AWG Stranded/25mm2/4AWG Flexible 35mm DIN Rail per EN 60715 UL 94V0 Thermoplastic IP20 3 Modules, DIN 43880 UL 1449 3rd Edition (Type 2)** IEC 61643-11 Type 2, IEC 61643-1 Class II Five Years*** Remote Contact Signaling Remote Contact Signaling Type AC Switching Capacity (Volts/Amps) DC Switching Capacity (Volts/Amps) Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals Ordering Information Changeover Contact 250V/0.1A 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75°C Max. 1.5mm2/14AWG Solid/Flexible Order from Catalog Numbers Above * MCOV Between two conductors. ** Does not apply to 1200Vdc. *** See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Typical Application Schematics Replacement Modules System Voltage 600Vdc Left BPH300YPV BPH500YPV BPH600YPV 1000Vdc 1200Vdc Center BPM300YPV BPM500YPV BPM600YPV Right BPH300YPV BPH500YPV BPH600YPV The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. © 2010 Cooper Bussmann www.cooperbussmann.com 0910 BU-SB09723 Page 2 of 2 Data Sheet 2055 Surge Protection Made Simple™ Wind Power Applications Advanced, Easy-to-Use Surge & Lightning Protection Products for Wind Power Systems • Modular DIN-rail design with color-coding and rejection feature makes it easy to identify, install and maintain. • High surge discharge capacity due to heavy-duty zinc oxide varistor and spark-gap technology. • easyID™ Visual indication and optional remote contact signaling make status monitoring simple. • Vibration and shock resistant according to EN 60068-2 standards. • Wide range of IEC Class I and Class II SPD covering all the major markets around the world. See data sheet #2091 to 2095 • www.cooperbussmann.com/Surge The Need for Surge Protection The unique nature of Wind Power installations make them vulnerable to overvoltages and surges from lightning strikes and static discharges. These surges need to be intercepted before they take down the entire system by damaging the Wind Power arrays, charge controller/inverter and combiner boxes. In any Wind Power system, it is vital that surge suppressor elements that are subject to wear, are easily monitored for performance. The Cooper Bussmann Wind Power Surge Suppression systems provide standard easyID™ visual indication and remote contact signaling to keep system maintainers apprised of the protection level being delivered. Safe and Simple •IP20 Finger-safe construction and suppressor rejection feature make it easy to know the suppressor system is installed and properly operating to protect your Wind Power system investment. •Simply specify the system voltage and whether the remote contact signaling is desired. •Five year limited warranty.* Part Number System BSP X X XXX XXX X BSP = Product Series Technology Type M = MOV S = Spark-Gap H = Hybrid G = GDT Poles 1 = 1-pole 2 = 2-pole 3 = 3-pole 4 = 4-pole System Voltage 75 = 75Vac 230 = 230Vac 400 = 400Vac 690 = 690Vac 1000 = 1000Vac System Type WE = Wind Power Optional Remote Contact Signaling R = Optional contact signaling Blank = No remote switch option Complete Line of Surge Protection Solutions Cooper Bussmann offers surge protection products for PV, telecom, UL and IEC applications. easy ID™ Reference product data sheets for specific agency approval information. PV Wind Telecom UL IEC Ordering Information TN TN TN TT TN TNC TNC TNC TT 1 1 1 1 2 3 3 3 2 75 690 1000 230 230 230 400 690 230 Lightning Arrestors - Wind Power IEC Type 1 Cooper Bussmann Part Number Description BSPS1690WER 690V Combined lightning current and surge arrestor for single-pole TN systems (remote) BSPS1400WE(R) 400V Combined lightning current and surge arrestor for single-pole TN-C systems (remote) Surge Arrestors - Wind Power IEC Type 2 BSPM175WE(R) 75V Surge arrestor for single-pole TN systems (remote) BSPM1690WE(R) 690V Surge arrestor for single-pole TN systems (remote) BSPM11000WE(R) 1000V Surge arrestor for single-pole TN systems (remote) BSPG1230WE(R) 230V Surge arrestor for single-pole TT systems (remote) BSPM2230WE(R) 230V Surge arrestor for 2-pole TN systems (remote) BSPM3230WE(R) 230V Surge arrestor for 3-pole TNC systems (remote) BSPM3400WE(R) 400V Surge arrestor for 3-pole TNC systems (remote) BSPM3690WE(R) 690V Surge arrestor for 3-pole TNC systems (remote) BSPH2230WE(R) 230V Surge arrestor for 2-pole TT systems (remote) TT 4 230 BSPH4230WE(R) 230V Surge arrestor for 4-pole TT systems (remote) TNS 4 230 BSPM4230WE(R) 230V Surge arrestor for 4-pole TNS systems (remote) Power System Poles TN 1 TNC 1 Volts 690 400 * See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. © 2 0 11 C o o p e r B u s s m a n n w w w. c o o p e r b u s s m a n n . c o m Reorder # 3176 0311 Modules N/A N/A BPM75WE BPM750WE N/A BPG255NPEWE BPM275WE BPM275WE BPM440WE BPM750WE BPM275WE, BPSNPEWE BPM275WE, BPSNPEWE BPM275WE Surge Protection Made Simple™ IEC Applications High Performance Lightning & Surge Protection Products for All IEC Applications • Vibration and shock resistant according to EN 60068-2 standards. • easyID™ Visual indication and optional remote contact signaling make status monitoring simple. • High surge discharge capacity due to heavy-duty zinc oxide varistor and spark-gap technology. • Wide range of IEC Class l and Class ll SPD covering all the major markets around the world. • Modular DIN-rail design with color-coding and rejection feature makes it easy to identify, install and maintain. See data sheets #1163 to 1169 • www.cooperbussmann.com/surge The Need for Surge Protection Today’s world is full of electronic products and devices that are susceptible to damage from overvoltage surges. Base & Module Number System BSP X X Whether the cause is static discharge or lightning, overvoltage surges can quickly destroy consumer electronics or sophisticated electronic packages used in industrial and commercial applications. Poles 1 = 1-pole 2 = 2-pole Safe and Simple System Type IT = IT system TN = TN system TNC = TNC system •IP20 Finger-safe construction. •Suppressor rejection feature make it easy to know the suppressor system is installed and properly operating to protect your IEC system investment. 3 = 3-pole 4 = 4-pole TNS = TNS system TT = TT system Optional Remote Contact Signaling R = Optional contact signaling Blank = No remote switch option •Simple selection of system voltage and remote contact signaling option. Complete Line of Surge Protection Solutions X System Voltage 230 = 230Vac 320 - 320Vac - Specific to India 400 = 400Vac - Specific to China 440 = 440Vac Surge protection products from Cooper Bussmann help assure power quality that’s free from damaging surges and overvoltage conditions. •Five year limited warranty.* XXX XXX BSP = Product Series Technology Type M = MOV H = Hybrid S = Spark-Gap G = GDT Replacement Module Number System BP X XXX BP = Product Series Technology M = MOV S = Spark-Gap Cooper Bussmann offers surge protection products for PV, wind power, telecom and UL, applications. XXX H = Hybrid G = GDT MCOV 50NPE*, 100NPE*, 255, 275, 320, 385, 440 *NPE = Neutral to Earth System Type IEC = All IEC System Types PV Wind Telecom UL IEC Ordering Information Power System Poles TN 2 Volts 230 Lightning Arrestors - IEC Class l Cooper Bussmann Part Number Description BSPS2255TN(R) 230V Combined lightning current and surge arrestor for 2-pole TN systems (remote) TNC TNS TT 3 4 2 230 230 230 BSPS3255TNC(R) BSPS4255TNS(R) BSPS2255TT(R) TT 4 230 BSPS4255TT(R) TN TN TN TN TN TN TNC TNS TT 1 1 1 1 1 2 3 4 2 230 230 320 400 440 230 230 230 230 BSPM1275TN(R) BSPG1255NPE(R) BSPM1320TN(R) BSPM1385TN(R) BSPM1440TN(R) BSPM2275TN(R) BSPM3275TNC(R) BSPM4275TNS(R) BSPH2275TT(R) 230V Combined lightning current and surge arrestor for 3-pole TN-C systems (remote) 230V Combined lightning current and surge arrestor for 4-pole TN-S systems (remote) 230V Combined lightning current and surge arrestor for single-pole 1+1 TT and TN systems (remote) 230/400V Combined lightning current and surge arrestor for 3+1 TT and TN-S systems (remote) Surge Arrestors - IEC Class ll 230V Surge arrestor for single-pole TN systems (remote) 240V 1-Pole GDT DIN rail SPD for N-PE (remote) 320V Surge arrestor for single-pole TN systems (remote) (India Market 230/400V) 400V Surge arrestor for single-pole TN systems (remote) (Chinese Market 230/400) 440V Surge arrestor for single-pole TNC systems (400/690V) (remote) 230V Surge arrestor for 2-pole TN systems (remote) 230/400V Surge arrestor for 3-pole TNC systems (remote) 230/400V Surge arrestor for 3-pole TNS systems (remote) 230V Surge arrestor for 2-pole phase TT systems (remote) TT 4 230 BSPH4275TT(R) 230/400V Surge arrestor for 3+1 TT and TN-S systems (remote) * See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. © 2 0 11 C o o p e r B u s s m a n n w w w. c o o p e r b u s s m a n n . c o m Reorder #3167 0111 Printed in USA Modules BPS255IEC, BPS50NPE BPS255IEC BPS255IEC BPS255IEC, BPS50NPE BPS255IEC, BPS100NPE BPM275IEC BPG255NPE BPM320IEC BPM385IEC BPM440IEC BPM275IEC BPM275IEC BPM275IEC BPM275IEC, BPSNPE BPM275IEC, BPSNPE