Emerson Network Power SmartRow™ for Digital Ceiling The SmartRow for Digital Ceiling contains all supporting infrastructure required to successfully deploy your Cisco Digital Ceiling in up to a 120,000ft2 building. This row based system is specifically designed to support up to 50 Cisco 3850 switches featuring 24 PoE 60W ports on each switch, for a maximum of 1,200 PoE end-points. The SmartRow for Digital Ceiling completely eliminates the need to build a dedicated MDF/IDF closet to host your Digital Ceiling infrastructure in large buildings. SmartRow delivers data center grade thermal management, UPS power conditioning, monitoring and control technologies, emergency ventilation and cable management all in an enclosed room neutral system. With multiple ways to configure for future expansion, and power and cooling redundancy levels, it is a flexible solution to meet today’s needs while being prepared for the unknown of tomorrow. It will save several weeks in your construction schedule and decreases the number of people required to finish the project. SmartRow™ A simple, fully integrated, pre-engineered end-to-end solution for Cisco Digital Ceiling 3850 switches. Emerson Network Power SmartRow™ for Digital Ceiling The SmartRow for Digital Ceiling contains all supporting infrastructure required to successfully deploy your Cisco Digital Ceiling in up to a 120,000 ft2 building. It will save several weeks in your construction schedule and decreases the number of people required to finish the project. Complete Datacenter Infrastructure. The SmartRow contains all of the necessary sub-systems to create the datacenter environment required to support the Cisco 3850 switches inclusive of the racks, power conditioning and distribution, cooling with automatic back-up ventilation equipment, and monitoring. Room Neutral Design. The SmartRow’s closed architecture isolates the system from the building HVAC which typically can not support the dense heat load. It also avoids issues resulting from building HVAC setback operation during nights and weekends which can cause these switches to shutdown on high temperature. This factory engineered architecture allows for very predictable and repeatable performance on-site while delivering up to 27% energy savings over alternative approaches. Power Distribution and Back-up. The SmartRow comes equipped with a high-efficiency, redundant 75kVA Liebert® APM™ UPS with battery cabinet options for either standard or extended battery runtimes, a power bypass / distribution cabinet, and intelligent rack PDU’s. The intelligent rack PDU’s allow you to monitor and control each of the (120) C13 receptacles individually for greater awareness and allows for hard-rebooting of switches remotely. Physical Security. The SmartRow for Digital Ceiling has lockable front and rear networking racks and can be equipped with additional sensors and access controls for remote awareness and management. Expansion Channels. Fully enclosing the SmartRow system, the expansion channels ensure only conditioned air reaches the Cisco switches, UPS and batteries while also increasing the capacity and efficiency of the cooling system. The expansion channels also reduce the sound level of the row based equipment and its dependency on the building HVAC allowing the SmartRow to be deployed in shared spaces – no need to build out dedicated MDF/IDF rooms. Controls and Monitoring. The SmartRow comes equipped with Liebert iCOM™ controls that manage the cooling system in real-time, including the outdoor heat rejection, and ensures the highest levels of efficiency. All power and cooling components can be managed via the network using standard management protocols. Remote Access. You will be able to always access the Cisco switches through your network or a modem connection. This means you will never lose access to your network equipment and will be able to commission, troubleshoot, and fix issues remotely saving you time and money. Cooling System. The SmartRow integrated high-efficiency cooling system is comprised of an 20kW air-cooled Liebert CRV™ row based cooling unit, a high efficiency outdoor condenser, and back-up ventilation fans that will automatically activate during a loss of primary cooling to prevent the switches from overheating. With standard and expanded outdoor temperature configurations available, the SmartRow for Digital Ceiling can be quickly deployed in virtually any location. Cooling. Variable capacity, high efficiency thermal management for typical and extreme climates. UPS. Conditioned power and distribution with extended runtime. Backup Fans. Automatic emergency backup ventilation. Cabinets. Two 42U, 800mm wide cabinets house 50 Cisco 3850 switches. Expansion. Easily add-on an additional cabinet with power distribution. Closed Architecture. Quiet, highly efficient, predicatable performance. 2 Emerson Network Power SmartRow™ for Digital Ceiling Emergency Ventilation Fans Automatically activate during a loss of primary cooling Appearance Trim Helps provide a clean installation Cable Trays Help manage the large volume of PoE cabling Expansion Channels Isolate the SmartRow from its surroundings, increasing security and energy efficiency while reducing site dependency Primary Cooling Up to 20kW of rack-mount heat can be efficiently and reliably rejected year round Backup Batteries Standard and extended backup power runtimes available UPS System 75kVA of continuous conditioned power Networking Racks 42U cabinets optimized for 1,200 cables Power Distribution The maintenance bypass cabinet allows for service to the UPS system while still powering the switches 75kVA SmartRow for Digital Ceiling Reliable year round performance in extreme climates Complete Awareness 75kVA SmartRow™ for Digital Ceiling 90 A SmartRow for Digital Ceiling allows you to remotely monitoring the environment in which your Digital Ceiling is running to ensure that you will receive alerts when conditions degrade. 80 70 60 50 Power awareness: You will receive alarms when the utility power is down and the UPS is running on battery. 40 30 20 10 0 200 Outdoor Heat Rejection 300 400 500 600 700 800 900 1000 1100 PoE End-Points (60W per Port) Standard Run-time Extended Run-time Up to 50 Cisco 3850 switches with 1,200 PoE ports can be supported by the SmartRow system. A minimum of 4kW of continuous heat load must be maintained inside the SmartRow (equivalent to 19 fully loaded Cisco 3850 switches). Thermal awareness: Two temperature sensors monitor each rack of Cisco switches to ensure the temperature of the incoming air is within the acceptable range for operating the Digital Ceiling. The cooling and UPS systems have full SNMP capabilities and will allow you to monitor the power and sensors on a SmartRow via any network management software or BMS that supports SNMP. 3 Emerson Network Power SmartRow™ for Digital Ceiling Battery UPS Quiet Secure Distribution Efficient Switches Fast to Deploy Switches Cooling Reliable Control Ordering Info SmartRow™ for Digital Ceiling for up to 50 Cisco 3850 switches Model number 2 Rack 75kVA SmartRow DCX with standard UPS runtime and standard outdoor temperature range BAB0AJAJ00AAA 2 Rack 75kVA SmartRow DCX with extended UPS runtime and standard outdoor temperature range BAB0AMAJ00AAA 2 Rack 75kVA SmartRow DCX with standard UPS runtime and expanded outdoor temperature range BAF0AJAJ00AAA 2 Rack 75kVA SmartRow DCX with extended UPS runtime and expanded outdoor temperature range BAF0AMAJ00AAA Standard outdoor temperature range: -20 to 110°F Expanded outdoor temperature range: -30 to 120°F The SKUs above have been created for your convenience; however, you have full flexibility on how your SmartRow is configured. Extended warranty and preventative maintenance plans are available. Please send your questions or customization request to DigitalCeiling@Emerson.com SmartRow™ for Digital Ceiling can be equipped with a UL924 compliant UPS system. UL924 states that compliant building lighting must provide at least 90 minutes of battery powered illumination, even under extreme conditions such as electrical surges and full loads, to ensure building occupants are provided time to evacuate. Emergency lighting shall engage automatically and immediately after a primary power failure. EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2016 Emerson Electric Co. While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2016 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. ® Liebert is a registered trademark of the Liebert Corporation. SL-XXXX (R06/16) Printed in USA