Liebert® IntelliSlotTM Unity Card Version 5.1.0.0_95201 Firmware Release Notes October 30th, 2015 This document outlines: 1. Version and Compatibility Information 2. What’s New 3. Security Issues Addressed 4. Upgrade Instructions 5. Known Issues =================================================================================== 1. Version and Compatibility =================================================================================== This release contains the following firmware version: IS-UNITY_5.1.0.0_95201 This release is compatible with the following Liebert IntelliSlot communication cards: IS-UNITY-DP IS-UNITY-LIFE This release is compatible with the following Liebert power and thermal management equipment: Liebert APM™ Liebert HPC™ Liebert APS™ Liebert HPC-S,M,R,W,Generic Liebert CRV™ Liebert HPM™ Liebert CW™* Liebert NX™ 225-600 KVA Liebert Challenger™* Liebert NXC™ Liebert Deluxe System/3™* Liebert NXL™ Liebert DCP™ Liebert NXR™ Liebert DS™* Liebert PCW™ Liebert DSE™ Liebert PDX™ Liebert eXL™ Liebert PeX™* Liebert eXM™ Liebert XDC™ with iCOMTM Control Liebert GXT3™ Liebert XDP™ with iCOMTM Control Liebert GXT4™ Liebert XDP-Cray *iCOM Firmware PA1.04.033.STD versions or later 1 Emerson. Consider it Solved., Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2015 Emerson Electric Co. All rights reserved. Microsoft and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation. Google and Chrome are either registered trademarks or trademarks of Google, Inc. Mozilla and Firefox are either registered trademarks or trademarks of Mozilla Foundation Corporation. Safari, MacBook, and iPad are registered trademarks of Apple, Inc. All other trademarks, brand names, and service marks are the property of their respective owners. This release is compatible with the following sensors: Liebert SN-2D Liebert SN-T Liebert SN-Z02 Liebert SN-3C Liebert SN-TH Liebert SN-Z03 Liebert SN-L Liebert SN-Z01 This release supports the following communication interfaces: Communication Protocol Communication Card LIFE™ Services Support HTTP/ HTTPS Emerson Protocol Email SMS SNMP v1,v2c,v3 BACnet IP/MSTP Modbus TCP/RTU YDN23 IS-UNITY-DP NXL & PeX Only IS-UNITY-LIFE - - - - - - Third-Party Protocols This release supports the following browsers: o Microsoft Internet Explorer® - IE9, IE10, and IE11 o Mozilla Firefox® - ver. 28.0 or later o Google ChromeTM - ver. 34.0.1847.116 m or later o Safari® (MacBook®) - ver. 6.1.1 and 8.0.5 o Safari® (iPad®) - ver. 5.1.1 and 7.1 =================================================================================== 2. What’s New =================================================================================== This release contains the following enhancements: Support for the Liebert NX 225-600 KVA UPS units that includes o Web (HTTP/HTTPS) o Emerson Protocol o SNMP v1/v2c/v3 o Email o BACnet MSTP/IP o SMS o Modbus RTU/TCP BACnet & Modbus support for Liebert GXT3 and Liebert GXT4 UPS units NOTE: The Modbus protocol mapping for the GXT is different from the mapping used with the OC-485 card. See the Liebert IntelliSlot Modbus 485, Modbus IP and BACnet IP Reference Guide (SL-28170) for more details. 2 Emerson. Consider it Solved., Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2015 Emerson Electric Co. All rights reserved. Microsoft and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation. Google and Chrome are either registered trademarks or trademarks of Google, Inc. Mozilla and Firefox are either registered trademarks or trademarks of Mozilla Foundation Corporation. Safari, MacBook, and iPad are registered trademarks of Apple, Inc. All other trademarks, brand names, and service marks are the property of their respective owners. This release contains fixes for the following issues: Component Description Web Interface The Web user interface was enhanced to prevent security vulnerabilities, including IP forwarding, cross-site scripting, and vulnerability to malformed web queries. The Web user interface will no longer allow entering angle brackets ("<" and ">") in text input fields. OpenSSL has been upgraded to version 0.9.8zg which includes recent security fixes. Data points unique to some Liebert GXT3/4 Dual Inverter UPS models which were not included in the previous Unity release are now supported. Liebert GXT3 Dual Inverter UPS units are now properly discovered. SSL Liebert GXT3/4 UPS Support SNMP Added some missing RFC1628 MIB product information data values for several UPS products. Added and fixed various SNMP data point behavior for GXT3 and GXT4 units. BACnet Performance improvements were made to improve response time in BACnet MSTP token passing. =================================================================================== 3. Security Issues Addressed =================================================================================== The following highly publicized security vulnerabilities have already been addressed in a previous release: Name Description “ShellShock” Updated bash version to fix this in release 4.2 “Poodle” SSLv3 was disabled in release 5.0 =================================================================================== 4. Update Instructions =================================================================================== The Unity cards may be updated to this firmware version using the web-based Firmware Upload feature. Please refer to the Firmware Updates section of the Liebert IntelliSlot Unity Card User Manual (SL-52645). =================================================================================== 5. Known Issues =================================================================================== Component Description Device Settings When temperature settings are made on some thermal devices, there may be some ‘round-off’ error of one tenth of a degree between what was requested and what the device shows after the change. This is a known limitation of some thermal device firmware versions and will be corrected in future versions of the device controller firmware. 3 Emerson. Consider it Solved., Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2015 Emerson Electric Co. All rights reserved. Microsoft and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation. Google and Chrome are either registered trademarks or trademarks of Google, Inc. Mozilla and Firefox are either registered trademarks or trademarks of Mozilla Foundation Corporation. Safari, MacBook, and iPad are registered trademarks of Apple, Inc. All other trademarks, brand names, and service marks are the property of their respective owners. Component Description Liebert GXT3/4 UPS Support The IP address of the Unity card may be displayed on the local display of the Liebert GXT4 UPS unit. The IP address is pushed to the GXT4 when the card starts up. If the address changes (for example, if it is changed by the DHCP server when the DHCP lease runs out), the local GXT4 display will continue to show the old address until the card is restarted. While the SNMP OIDS for the GXT are backward compatible with those from the IS-WEBCARD, the text values in some SNMP varbinds and email/SMS notifications have changed slightly to use the Unity card equivalent. The preferred way to change the display order for multiple sensors is through the Web user interface. If the order is changed using one of the supported protocols then the entire list of sensors should be set in the correct order (including slots that should become blank) to ensure all sensors are still included. Sensor order is not reflected in the SNMP flexible MIB until after the card is rebooted. Reboot the card after setting the sensor order. SNMP getnext requests may fail on some tables if there are multiple varbinds in the request. If this occurs, use single-varbind requests. When using a recent version of the Firefox browser, do not disable the “Accept cookies from sites” option, and do not select the “Ask me every time” option for how long to keep cookies. Either of these settings causes the web page to stall on the initialization page. Sensor Support SNMP Web 4 Emerson. Consider it Solved., Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2015 Emerson Electric Co. All rights reserved. Microsoft and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation. Google and Chrome are either registered trademarks or trademarks of Google, Inc. Mozilla and Firefox are either registered trademarks or trademarks of Mozilla Foundation Corporation. Safari, MacBook, and iPad are registered trademarks of Apple, Inc. All other trademarks, brand names, and service marks are the property of their respective owners.