56-57.qxp 5/27/2011 3F 12:36 AM Page 56 Condulet® Conduit Outlet Boxes With Covers 3F EAJ Series EAJX Applications: Options: EAJ series conduit outlet boxes are installed in conduit systems within hazardous areas to: • Protect conductors in threaded rigid conduit • Act as pull and splice boxes • Interconnect lengths of conduit • Change conduit direction • Provide access to conductors for maintenance and future system changes • Act as mounting outlets for fixtures (with appropriate covers) • Act as sealing fittings (with appropriate covers) Description Bodies – copper-free aluminum Covers – Feraloy iron alloy – electrogalvanized and aluminum acrylic paint Corro-free epoxy powder coat Certifications and Compliances: EAJB EAJC EAJD 33/16 33/16 33/16 /2 /4 1 1 3 EAJX16† EAJX26† EAJX36† Flat Covers Cover Opening Dia. Hub Size Cat. # 33/16 33/16 33/16 /2 3 /4 1 1 EAJB16† EAJB26† EAJB36† Cover Opening Dia. Cat. # 3 /16 5 EAJ06 EAJ09 3 Dome Covers Cover Opening Depth Cat. # Dia. Cover Opening Dia. Hub Size Cat. # 33/16 33/16 33/16 /2 /4 1 1 3 EAJC16† EAJC26† EAJC36† 33/16 2 EAJ0612 Fixture Covers Union Hub Type Cover Opening Dia. Hub Size Cat. # 33/16 33/16 33/16 /2 3 /4 1 1 EAJD16† EAJD26† EAJD36† Cover Opening Dia. Fixt. Stem Size Cat. # 33/16 3 /4 EAJ0687* Dimensions In Inches: EAJT • Body – Feraloy® iron alloy • Cover – copper-free aluminum Standard Finishes: • Feraloy iron alloy – electrogalvanized and aluminum acrylic paint • Aluminum – natural www.crouse-hinds.com WOD S752 Hub. Size Cat. # • Hub – 1/2" to 2" • Cover opening – 33/16" to 5" dia. Standard Materials: 56 SA† Cover Opening Dia. EAJ Threaded Covers EAJL • NEC/CEC: Class I, Division 1 & 2, Groups A‡,B,C,D Class II, Division 1, Groups E,F,G Class II, Division 2, Groups F,G Class III • UL Standard: 886 • CSA Standard: C22.2 No. 30 Suffix Size Ranges: Features: EAJ conduit outlet boxes have: • Water shedding cover – suitable for wet locations when mounted in upright position • External cover threads on body protecting conductors from damage during pulling • No pinching of conductors during cover installation • Six different hub arrangements • Taper threaded hubs to provide ground continuity • Smooth integral hub bushing to protect conductor insulation when pulling • Internally threaded cover openings for additional wiring room • Flat overlapping threaded covers furnished with boxes • Weather-resistant finish • Green ground screw standard in all boxes • Four standard mounting pads, except for EAJB and EAJD Explosionproof Dust-Ignitionproof Raintight Wet Locations Cl. I, Div. 1 & 2, Groups A‡, B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 7ABCD, 9EFG US: 1-866-764-5454 Cover Opening Dia. Hub Size Cat. # 33/16 33/16 33/16 /2 /4 1 Cover Opening Dia. Hub Size Cat. # 33/16 33/16 33/16 5 5 5 CAN: 1-800-265-0502 1 3 /2 /4 1 11/4 11/2 2 1 3 EAJL16† EAJL26† EAJL36† EAJT16† EAJT26† EAJT36† EAJT49†‡ EAJT59†‡ EAJT69†‡ Cat. # a b c 16 26 36 49 59 69 217/32 225/32 225/32 41/16 41/16 41/16 11/2 3/4 13/4 7/8 13/4 7/8 23/16 13/32 3 11/2 3 11/2 33/4 33/4 33/4 53/4 53/4 53/4 d e f 55/16 59/16 59/16 75/16 713/16 713/16 33/32 33/32 33/32 43/4 43/4 43/4 *EAJ0687 is listed for Group C & D only. †Available in copper-free aluminum, add suffix -SA. ‡Form 9 products with 5" cover opening are not suitable for Group A. Copyright© 2011 Cooper Crouse-Hinds