3F Condulet® Conduit Outlet Boxes With Covers

advertisement
56-57.qxp
5/27/2011
3F
12:36 AM
Page 56
Condulet® Conduit Outlet
Boxes With Covers
3F
EAJ Series
EAJX
Applications:
Options:
EAJ series conduit outlet boxes are
installed in conduit systems within
hazardous areas to:
• Protect conductors in threaded rigid
conduit
• Act as pull and splice boxes
• Interconnect lengths of conduit
• Change conduit direction
• Provide access to conductors for
maintenance and future system changes
• Act as mounting outlets for fixtures (with
appropriate covers)
• Act as sealing fittings (with appropriate
covers)
Description
Bodies – copper-free aluminum
Covers – Feraloy iron alloy –
electrogalvanized and aluminum
acrylic paint
Corro-free epoxy powder coat
Certifications and
Compliances:
EAJB
EAJC
EAJD
33/16
33/16
33/16
/2
/4
1
1
3
EAJX16†
EAJX26†
EAJX36†
Flat Covers
Cover
Opening
Dia.
Hub
Size Cat. #
33/16
33/16
33/16
/2
3
/4
1
1
EAJB16†
EAJB26†
EAJB36†
Cover Opening Dia.
Cat. #
3 /16
5
EAJ06
EAJ09
3
Dome Covers
Cover
Opening
Depth Cat. #
Dia.
Cover
Opening
Dia.
Hub
Size Cat. #
33/16
33/16
33/16
/2
/4
1
1
3
EAJC16†
EAJC26†
EAJC36†
33/16
2
EAJ0612
Fixture Covers
Union Hub Type
Cover
Opening
Dia.
Hub
Size Cat. #
33/16
33/16
33/16
/2
3
/4
1
1
EAJD16†
EAJD26†
EAJD36†
Cover
Opening
Dia.
Fixt.
Stem
Size Cat. #
33/16
3
/4
EAJ0687*
Dimensions
In Inches:
EAJT
• Body – Feraloy® iron alloy
• Cover – copper-free aluminum
Standard Finishes:
• Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
• Aluminum – natural
www.crouse-hinds.com
WOD
S752
Hub.
Size Cat. #
• Hub – 1/2" to 2"
• Cover opening – 33/16" to 5" dia.
Standard Materials:
56
SA†
Cover
Opening
Dia.
EAJ Threaded Covers
EAJL
• NEC/CEC:
Class I, Division 1 & 2, Groups A‡,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
• UL Standard: 886
• CSA Standard: C22.2 No. 30
Suffix
Size Ranges:
Features:
EAJ conduit outlet boxes have:
• Water shedding cover – suitable for wet
locations when mounted in upright
position
• External cover threads on body protecting
conductors from damage during pulling
• No pinching of conductors during cover
installation
• Six different hub arrangements
• Taper threaded hubs to provide ground
continuity
• Smooth integral hub bushing to protect
conductor insulation when pulling
• Internally threaded cover openings for
additional wiring room
• Flat overlapping threaded covers
furnished with boxes
• Weather-resistant finish
• Green ground screw standard in all boxes
• Four standard mounting pads, except for
EAJB and EAJD
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Cl. I, Div. 1 & 2, Groups A‡, B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 4, 7ABCD, 9EFG
US: 1-866-764-5454
Cover
Opening
Dia.
Hub
Size Cat. #
33/16
33/16
33/16
/2
/4
1
Cover
Opening
Dia.
Hub
Size Cat. #
33/16
33/16
33/16
5
5
5
CAN: 1-800-265-0502
1
3
/2
/4
1
11/4
11/2
2
1
3
EAJL16†
EAJL26†
EAJL36†
EAJT16†
EAJT26†
EAJT36†
EAJT49†‡
EAJT59†‡
EAJT69†‡
Cat. # a
b
c
16
26
36
49
59
69
217/32
225/32
225/32
41/16
41/16
41/16
11/2 3/4
13/4 7/8
13/4 7/8
23/16 13/32
3
11/2
3
11/2
33/4
33/4
33/4
53/4
53/4
53/4
d
e
f
55/16
59/16
59/16
75/16
713/16
713/16
33/32
33/32
33/32
43/4
43/4
43/4
*EAJ0687 is listed for Group C & D only.
†Available in copper-free aluminum, add suffix -SA.
‡Form 9 products with 5" cover opening are not
suitable for Group A.
Copyright© 2011 Cooper Crouse-Hinds
Download