FACT OPTICAL DISTRIBUTION FRAME SYSTEM Fiber Connectivity for Splice/Patch and Patch/Patch For almost 30 years, CommScope has led the industry with solutions such as FIST fiber management system, providing a system of fiber management from the central office through the customer premises. Now, we continue that leadership with the introduction of the FACT ODF system, enabling faster and easier installation in a high density environment. The toolless system approach and the high level of modularity guarantee an easy migration path towards new connectivity platforms and expansion of existing central office sites. FACT modules support full patch and/or splice-patch functions within a rack environment. Trays within the element can be configured with adapters, splicing and passive optical components. Trays are staggered for easy fiber routing and access to connectors.Currently available, the FACT standard version integrates into a current partially or non-equipped FIST-GR2/3 frame or lineup. Features • Patching, using patch cords, connectorized breakout or intrafacility cables • Enhanced modularity created by stacking four elements together in a 3HU grouping • Kits available to attach cables at the side of the elements • Splicing loose tube, non-connectorized intrafacility or breakout cables to pigtails and patching these pigtails to patch cords • Full patching capability on the elements and between elements in one module and across modules • Full wrap-around solution accessible from the front to guide fibers and pigtail • Supports integration of passive optical splitters and wavelength division multiplexers • Use of connectorized cables allows repair of pigtails • Various connector/adapter types possible • Easy identification of each fiber 1 • Can be installed in FIST racks and metric (ETSI) rack sizes • FACT elements and modules are shipped with the maximum number of trays already installed. For more information, visit commscope.com FACT OPTICAL DISTRIBUTION FRAME SYSTEM Standard Size for FIST-GR Retrofit Benefits of advanced element patching • Easy: Full front access and non-moving fiber during element manipulation • Secure: Because of their position in the trays, connectors are better protected than in some front facing patch shelves • Fast: Toolless scalable system • Manipulation of patch cords does not cause transient losses • Clean: Both sides easily accessible for cleaning adapters • Reconnection to other positions in the same tray or shelf does not result in uncontrolled overlengths • Safe: Laser light oriented perpendicularly to the operator • Bend controls guide and protect the pigtail cable and ensure controlled cable routing • Accessible: Guaranteed full front access at both sides of connection • Visible: Patch cords do not hamper access or visibility of ports Dimensions of FACT elements Standard (retrofit in FIST-GR3 frames) Height in mm Width in mm Depth in mm 30.95 524 283.1 Number of standard/ small-form-factor adapters 24/48 Ordering FACT modules • Element colors: Orange (RAL 2011) and grey (RAL 7035) • Elements are always ordered fully loaded • For a list of accessories and consumables, please refer to the FACT accessories ordering guide • Elements are configured with single adapters* • Cable construction (the number of fibers per cable) will determine the number and combination of elements to be ordered • Depending on the cable’s fiber count, at least one of the total number required to support that number of fibers must be releasable (equipped with a latch that allows a set/combination of elements to be removed from the rack) • Elements support most common cable constructions (loose tube, central core, IFC) • Four (4) elements equal 3HU (125mm) * For FACT elements with adapter packs, please contact your local sales representative. 2 For more information, visit commscope.com FACT OPTICAL DISTRIBUTION FRAME SYSTEM Standard Size for FIST-GR Retrofit Cable fiber count SC connectors/adapters LC connectors/adapters 24 SC connectors per element(1) 48 LC connectors per element(2) Number of FCEs Height Units Number of FCEs Height Units 24 1 Fits 1HU 1* Fits 1HU 48 2 Fits 2HU 1 Fits 1HU 72 3 Fits 3HU 2** Fits 2HU 96 4 Fits 3HU 2 Fits 2HU 144 6 Fits 5HU 3 Fits 3HU 192 8 Fits 6HU 4 Fits 3HU 288 - - 6 Fits 5HU 1 SC connectors with up to 2.4mm patch cords 2 LC connectors with up to 1.8mm patch cords * E lement ships with 2 trays, each with 12 LC adapters (24 LC connections); 48 LC connections in total. Unused tray may be discarded or used for future growth. ** E ach elements ship with 2 trays, each with 12 LC adapters (24 LC connections). 96 LC connections in total. Unused trays may be discarded or used for future growth. 3 For more information, visit commscope.com FACT OPTICAL DISTRIBUTION FRAME SYSTEM Standard Size for FIST-GR Retrofit FACT STANDARD SIZE Ordered for retrofit into a current partially or non-equipped FIST-GR2/3 frame or lineup. 4 For more information, visit commscope.com FACT OPTICAL DISTRIBUTION FRAME SYSTEM Standard Size for FIST-GR Retrofit Ordering Information FACT Module - Standard Size Patch only. No Cable. Standard kit includes: • Trumpets • Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 8 for information. Ordering Information FACT - S -XXX XX AA - 0 NN Port count 024 24-position (SC only) 048 48-position 072 72-position (SC only) 096 96-position 144 144-position 192 192-position 288 288-position (LC only) Adaptor type Single adapters S1 SC/UPC S2 SC/APC 8° L1 LC/UPC L2 LC/APC E9 E2000 8° For FACT elements with adapter packs, please contact your local sales representative. 5 For more information, visit commscope.com FACT OPTICAL DISTRIBUTION FRAME SYSTEM Standard Size for FIST-GR Retrofit Ordering Information FACT Module - Standard Size Splice/Patch. No Cable. Standard kit includes: • Trumpets • Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 8 for information. Cable attachment kits ordered separately. Attachment size defined by cable size and fiber type. See pages 9 and 10 for information. Ordering Information FACT - S -XXX XX XX - 0 NN Port count 024 Tray Option 24-position (SC only) Standard adapters Right of Left of shelf(1) shelf(2) 048 48-position 072 72-position (SC only) Adapters; SMOUV splice protector; no fiber(3) AE EA 096 96-position Adapters; ANT splice holder(4); no fiber AF FA 144 144-position 192 192-position AI IA 288 288-position (LC only) Connector/adapters; with pigtails and SMOUV splice protector(3); fiber from adapters to splice holder, ready for incoming cable Connector/adapters; with pigtails and ANT splice holder(4); fiber from adapters to splice holder, ready for incoming cable AJ JA Adapter type Single adapters Standard (Grade C) Superior (Grade B) SC/UPC S1 - SC/APC 8° S2 SG SC/APC 9° S3 - LC/UPC L1 LF LC/APC L2 LG E2000 8° E9 - 1 2 3 4 Patch cords leave shelf to right Patch cords leave shelf to left 45 mm SMOUV heat shrink splice protector is included ANT splice holder ONLY; splice protectors must be ordered separately NOTE: Pigtails are installed with DIN IEC 60304 color coding. DIN IEC 60304 For FACT elements with adapter packs, please contact your local sales representative. Fiber 1 Red Fiber 7 Brown Fiber 2 Green Fiber 8 Violet Fiber 3 Blue Fiber 9 Aqua Fiber 4 Yellow Fiber 10 Black Fiber 5 White Fiber 11 Orange Fiber 6 Grey Fiber 12 Pink If you want a different color coding, please contact your local sales representative. 6 For more information, visit commscope.com FACT OPTICAL DISTRIBUTION FRAME SYSTEM Standard Size for FIST-GR Retrofit Ordering Information FACT Module - Standard Size Splice/Patch. Pre-cabled. Standard kit includes: • Trumpets (pre-installed) • Cable attachments (pre-installed) • Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 8 for information. Ordering Information FACT - S -XXX XX XX - XX XX Port count Intrafacility cable 024 24-position 048 48-position 072 72-position 096 96-position 144 144-position 192 192-position 288 288-position (LC only) 1A 12-fiber (no strength member) Micro-distribution breakout cable MA 8-fiber MB 12-fiber Length in meters Loose tube indoor cable 0-99 Adapter type Single adapters Standard (Grade C) Superior (Grade B) SC/UPC S1 - SC/APC 8° S2 SG SC/APC 9° S3 - LC/UPC L1 LF LC/APC L2 LG E2000 8° E9 - For FACT elements with adapter packs, please contact your local sales representative. OD 24-fiber OF 48-fiber OG 72-fiber OH 96-fiber For other cable types, please contact your sales representative. Tray Option Standard adapters Right of Left of shelf(1) shelf(2) Adapters; SMOUV splice protector; no fiber(3) AE EA Adapters; ANT splice holder(4); no fiber AF FA 1 2 3 4 Patch cords leave shelf to right Patch cords leave shelf to left 45 mm SMOUV heat shrink splice protector is included ANT splice holder ONLY; splice protectors must be ordered separately NOTE: Pigtails are installed with DIN IEC 60304 color coding. DIN IEC 60304 Fiber 1 Red Fiber 5 White Fiber 9 Aqua Fiber 2 Green Fiber 6 Grey Fiber 10 Black Fiber 3 Blue Fiber 7 Brown Fiber 11 Orange Fiber 4 Yellow Fiber 8 Violet Fiber 12 Pink If you want a different color coding, please contact your local sales representative. 7 For more information, visit commscope.com FACT OPTICAL DISTRIBUTION FRAME SYSTEM Standard Size for FIST-GR Retrofit Back plates for standard size FACT elements and modules Description Ordering Number Back plates Allow placement of FACT STANDARD size elements or modules in FIST-GR3 Fits 1 HU; mounts 1 standard size FACT element Kit includes: (2) cage nuts (2) bolts (2) washers (2) single U-shape FACT brackets FACT-BPLATE-1E-S Fits 2 HU; mounts 2 standard size FACT elements Kit includes: (4) cage nuts (4) bolts (4) washers (2) double U-shape FACT brackets FACT-BPLATE-2E-S Equal to 3 HU; mounts 4 standard size FACT elements (1 FACT module) Kit includes: (4) cage nuts (4) bolts (4) washers (4) double U-shape FACT brackets FACT-BPLATE-4E-S NOTE: W hen an empty FIST-GR3 rack is to be fully loaded with FACT elements, a kit (FACT-BPLATE-28E-S) is available. This one piece plate accommodates 28 FCE and occupies one half of the FIST-GR3 (2.2m) rack. Please contact your local sales representative for more information. Cable SC connectors/adapters LC connectors/adapters 24 SC connectors per element 48 LC connectors per element fiber count Number of FCEs Height Units Number of back plates Number of FCEs Height Units Number of back plates 24 1 Fits 1HU (1) 1E-S 1 Fits 1HU (1) 1E-S 48 2 Fits 2HU (1) 2E-S 1 Fits 1HU (1) 1E-S 72 3 Fits 3HU (1) 1E-S + (1) 2E-S 2 Fits 2HU (1) 2E-S 96 4 Fits 3HU (1) 4E-S 2 Fits 2HU (1) 2E-S 144 6 Fits 5HU (1) 2E-S + (1) 4E-S 3 Fits 3HU (1) 1E-S + (1) 2E-S 192 8 Fits 6HU (2) 4E-S 4 Fits 3HU (1) 4E-S 288 - - - 6 Fits 5HU (1) 2E-S (1) 4E-S 8 For more information, visit commscope.com FACT OPTICAL DISTRIBUTION FRAME SYSTEM Standard Size for FIST-GR Retrofit Cable attachment kits for standard size FACT elements and modules Description Ordering Number Cable bracket kits 250 μ cable For cable diameters up to 8.5mm* Occupies 1 FACT element Kit includes: Single cable attachment sub-assemblies Strength members 250 μ routing components Plastic covers 250 μ overtubing Overtubing fixation devices Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-SMALL-PF For cable diameters from 8.5mm to 15mm** Occupies 1 FACT element Kit includes: Single cable attachment sub-assembly Strength member 250 μ routing components Plastic cover 250 μ overtubing Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-MEDIUM-PF Cable bracket kits 900 μ cable For cable diameters up to 8.5mm* Occupies 1 FACT element Kit includes: Single cable attachment sub-assemblies Strength members 900 μ routing components Plastic covers Fiber fixation devices Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-SMALL-SF For cable diameters from 8.5mm to 15mm** Occupies 1 FACT element Kit includes: Single cable attachment sub-assemblies Strength members 900 μ routing components Plastic covers Fiber fixation devices Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-MEDIUM-SF * Note: Cable should be flexible and allow minimum bend radius of 75 mm. Cable attachment fits corrugated tube 10mm outer diameter ** Note: Cable should be flexible and allow minimum bend radius of 75 mm. Cable attachment fits corrugated tube 16mm outer diameter 9 For more information, visit commscope.com FACT OPTICAL DISTRIBUTION FRAME SYSTEM Standard Size for FIST-GR Retrofit Cable SC connectors/adapters LC connectors/adapters 24 SC connectors per element 48 LC connectors per element fiber count Number of FCEs Height Units Number of cable attachment kits SMALL MEDIUM Number of FCEs Height Units Number of cable attachment kits SMALL MEDIUM 24 1 Fits 1HU 1 1 - - - - 48 2 Fits 2HU 2 2 1 Fits 1HU 1 1 72 3 Fits 3HU 3 3 2 Fits 2HU 2 2 96 4 Fits 3HU 4 4 2 Fits 2HU 2 2 144 6 Fits 5HU 6 6 3 Fits 3HU 3 3 192 8 Fits 6HU 8 8 4 Fits 3HU 4 4 288 - - - - 6 Fits 5HU 6 6 www.commscope.com Visit our website or contact your local CommScope representative for more information. © 2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. PS-319161.4 (10/15)