CXA-0540 Dimming/Connector Type ■ Features ■ Applications F A MED ●With shut down function. ●With a sensing function for running out of lamp (alarm output). ●In the high-voltage generator (a terminal and a pattern), an anti-dust measure by silicone application is taken. (Notice) Applicable panel size becomes a standard. DC-AC Inverter ●1 output ●Applicable panel size: 3 to 15 inches ●With brightness control function (Pulse Width Modulation Dimming). MEASURE CXA-0540 Specifications (Please refer to each specification before use) Electrical Characteristics Item Unit Symbol min Iout (Maximum dimmer) Specification typ max Condition Vin(V) Vrmt(V) Vbr(V) Rbr(kΩ) Ta(℃) RL(kΩ) CL(PF)(*3) 6.5 7.0 12±1.2 5 0 - -30 to 80 80 5 6.0 6.5 7.0 12±1.2 5 - 0 -30 to 80 80 5 1.8 2.5 3.2 12±1.2 5 2.5 - -30 to 80 80 5 1.8 2.5 3.2 12±1.2 5 - 50 -30 to 80 80 5 0.40 12± 0.6 12± 0.6 12± 0.6 5 -30 to 80 -30 to 80 -30 to 80 80 80 80 5 5 5 -30 to 80 80 Output Current mArms Iout (Minimum dimmer) A mA kHz Iin1 Iin2 Freq1 Hz Freq2 (Duty frequency) Open Circuit Voltage Vrms Vopen Alarm Signal V Vst Input Current Oscillatory Frequency - 0 45 50 0.65 1 55 220 270 320 12± 0.6 5 1600 1700 2200 10.8min. 5 0 -30 to 80 ∞ 4.5 5.0 5.5 12±1.2 5 0 -30 to 80 ∞ - 0 0.5 12±1.2 5 0 -30 to 80 - 0 5 0 2.5 50 80 Remarks Voltage dimmer (*1) Volume dimmer (*1) Voltage dimmer (*1) Volume dimmer (*1) Remote ON Remote OFF 5 Open load 5 In case of lamp anomaly (*2) On a normal operation (*2) Connector type/1 output 6.0 (*1) Please refer to the connection diagram for details of a dimming method. (*2) Please refer to the connection diagram for details of alarm output. (*3) As equivalent circuit of panel load, connect resistance load (RL) and distributed capacity (CL), and have provided by an electrical characteristic. Other Specifications Dimming Function Operating Temperature Storage Temperature Operating Humidity Ratio Safety Standard Weight Dimensions (WxDxH) Fused Input Remote ON / OFF Alarm Signal Function Shutdown Function Silicone Coating on High Voltage Area Yes ℃ -30 to +80 ℃ -30 to +85 RH% 95max. UL60950-1 g mm ■ Conformity to RoHs Directive This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. 19typ. 110x22x8.5 (*4) Yes Yes Yes Yes Yes (*4) These dimensions are indicated the maximum only H. Others are typical values. ・All specifications are subject to change without notice. C-39 CXA-0540 Outline Drawing ③ 2-φ3.5±0.2 ① 3 1 CXA-0540 U 9405 MADE IN JAPAN CAUTION HIGH VOLTAGE 4±0.3 1 8 CN1 14±0.3 DC-AC Inverter 22±0.5 1 CN2 ② 12±0.5 84±0.3 110±0.5 8.5max. Label display example Product name, country of origin Silicon a:High voltage generating area (50mm from board end panel)* Connector type/1 output *From high-voltage generator, please secure space distance more than 3mm in top and bottom right and left. Unit: mm Connector No. Component name Type name Qty Remarks ① Printed circuit board PCB Composite (CEM-3) 1 UL94V-0 t=1.0 - ② Input connector CN1 53261-0871 1 Molex 51021-0800 ③ Output connector CN2 SM02(8.0)B-BHS-1-TB(LF)(SN) 1 J.S.T Mfg., Co., Ltd BHR-03VS-1 Terminal Number & Function Input side CN1 Terminal No. CN1-1 CN1-2 CN1-3 CN1-4 Symbol Vin GND Rating 12±1.2V 0V Recommended suitable connector Output side CN2 Remarks Power source input Terminal No. Symbol Rating Remarks CN2-1 VHIGH 520Vrms Output CN2-2 NC ー ー CN2-3 VLOW (2V) Output return Ground 0 to 0.4V : OFF 0V/2.5V to Vin Remote terminal 2.5 to Vin : ON 0 to 2.5V Dimmer terminal 1 CN1-6 Vbr1/Rbr1 /0 to 50kΩ Dimmer terminal 2 CN1-7 Vbr2/Rbr2 GND/0 to 50kΩ Alarm output Vst 0V/5V CN1-8 (output) Lamp open : 5V CN1-5 C-40 Vrmt ・All specifications are subject to change without notice. CXA-0540 Connections DC-AC Inverter RL: Load resistance (7W minimum) CL:Distributed capacity capacitor (3kV minimum) Unit operates Unit operates Operates Voltage dimmer Vbr = 0 㫋㫆 2.5V (0V: Maximum brightness) Does not operate Volume dimmer VR = 0 㫋㫆 50kΩ (0Ω: Maximum brightness) Does not operate Connector type/1 output Operate by ON-OFF of SW2 as follows. Operate by ON-OFF of SW1 as follows. Protection Circuit Operation Load condition Alarm output (CN1-8)*1 Does not shut down When normal When 1 load (lamp) are NG Shutdown function*2 㪌±㪇㪅㪌㪭 Shuts down *1. When more than one of SW3-SW4 in the connection diagram was opened, output alarm signal of 5V. *2. When all lamps were opened, this inverter has included protective function to stop operation in about 3 seconds. ・All specifications are subject to change without notice. C-41