Installation Instructions
Important Preinstallation Note: These instructions
are for accessible ceilings (lay-in or slot-grid).
For other ceiling conditions, consult factory. Handle fixture
by sheet metal sides only.
LIGHT FIELDS™ LFULED/LFFLED
Recessed LED Fixtures
Accessible Ceilings (Lay-In and Slot-Grid)
DO NOT REMOVE THE LED GEARTRAYS. THIS WILL VOID THE WARRANTY. Call Zumtobel at 1-800-448-4131 for questions.
DA N G E R
RISK OF FIRE AND ELECTRICAL SHOCK
4
Flexible conduit or cable
accessories by others
Contact, improper installation, or improper servicing
MAY RESULT IN DEATH OR SERIOUS INJURY!
Fixture must be installed by a qualified electrician only.
Fixture is intended for installation in accordance with
the National Electrical Code, local and federal code
specifications. Disconnect power at electrical panel
before servicing. Retain these instructions for
maintenance reference.
For 1x1 and 1x4 LFULED fixtures, the frame grid
will need to be built out to size at the site with
t-bar material.
Attach access plate to power supply. Knockout
in access plate 1/2" conduit (7/8" dia.).
5
Lift the fixture into the ceiling system and install,
ensuring that the frame sits in the tees. Secure to
ceiling structure per local codes. Handle fixture by sheet
metal sides only.
1
Unpack fixture(s). Fixtures are shipped fully
assembled.
2
Remove door frame containing lens by pulling up
at sides until it loosens, and then press spring ears
together until frame detaches from housing. Keep
door frame aside in safe location.
3
Remove access plate from top of housing.
NOTE: National or municipal codes must be followed regarding fixture installation
and set back of thermal insulating material from luminaire. As a guideline, any
insulation material must be held away from the luminaire by a minimum of 3".
Fixtures are not designed for direct contact with thermal insulation.
Zumtobel Lighting, Inc. ©2013
17-09 Zink Place, Unit 7
Fair Lawn, NJ 07410
845-691-6262 • 800-448-4131 • zli.us@zumtobel.com
Part # D00347CI Date 02/04/13 Page 1 of 2
Questions? Problems? Call (800) 448-4131
and we will be happy to assist you. For technical
specification sheets or other information about our
products, please go to www.zumtobel.us
Installation Instructions
Important Preinstallation Note: These instructions
are for accessible ceilings (lay-in or slot-grid).
For other ceiling conditions, consult factory. Handle fixture
by sheet metal sides only.
LIGHT FIELDS™ LFULED/LFFLED
Recessed LED Fixtures
Accessible Ceilings (Lay-In and Slot-Grid)
DO NOT REMOVE THE LED GEARTRAYS. THIS WILL VOID THE WARRANTY. Call Zumtobel at 1-800-448-4131 for questions.
DA N G E R
RISK OF FIRE AND ELECTRICAL SHOCK
Contact, improper installation, or improper servicing
MAY RESULT IN DEATH OR SERIOUS INJURY!
Fixture must be installed by a qualified electrician only.
Fixture is intended for installation in accordance with
the National Electrical Code, local and federal code
specifications. Disconnect power at electrical panel
before servicing. Retain these instructions for
maintenance reference.
6
Make electrical connections through access plate.
Reinstall access plate in housing. Make sure wires
do not get caught between plate and housing.
7
Reattach door frame. Reinstall springs by pressing
ears together and inserting into slot or retaining bracket.
Press up on door frame until it securely fits into fixture
on all sides.
Maintenance - Turn off power first!
1
Cleaning. Wipe with a soft, lint-free cloth to
avoid scratching the acrylic protective layer.
Do not use glass cleaner or other solvents.
2
3
Access to driver. Remove adjacent ceiling tile
to access driver.
Replacement of LED boards. Contact Zumtobel
at 1 (800) 448-4131.
WHEN REPLACING PCB ASSEMBLIES, PLEASE WEAR AN ESD
WRIST STRAP AND CONNECT IT TO THE METAL ENCLOSURE.
Zumtobel Lighting, Inc. ©2013
17-09 Zink Place, Unit 7
Fair Lawn, NJ 07410
845-691-6262 • 800-448-4131 • zli.us@zumtobel.com
Part # D00347CI Date 02/04/13 Page 2 of 2
Questions? Problems? Call (800) 448-4131
and we will be happy to assist you. For technical
specification sheets or other information about our
products, please go to www.zumtobel.us
Installation Instructions
Important Preinstallation Note: These instructions are
for recessed LIGHT FIELDS™ to be mounted flangeless in
inaccessible (gypsum board or selected concealed) ceilings.
Plaster frame provided for gypsum board installations.
For other ceiling conditions, consult factory.
LIGHT FIELDS™ LED LFTLED 1x1
Recessed LED Fixtures
Accessible Ceilings (Lay-In and Slot-Grid)
DO NOT REMOVE THE LED GEARTRAYS. THIS WILL VOID THE WARRANTY. Call Zumtobel at 1-800-448-4131 for questions.
DA N G E R
RISK OF FIRE AND ELECTRICAL SHOCK
Contact, improper installation, or improper servicing
MAY RESULT IN DEATH OR SERIOUS INJURY!
Fixture must be installed by a qualified electrician only.
Fixture is intended for installation in accordance with
the National Electrical Code, local and federal code
specifications. Disconnect power at electrical panel
before servicing. Retain these instructions for
maintenance reference.
2
3
4
Use template (provided) to cut hole in center of ceiling
grid. Hole should be 11 1/8" square.
Remove access plate from top of housing.
Insert fixture into tile from the bottom side.
1
Unpack fixture(s).
Fixtures are shipped fully assembled.
5
Attach adjustable mounting bracket by installing
screws into fixture housing. Adjust the height to
secure the fixture to the grid and tighten screws.
Mounting Hardware
by others
24"
Ceiling Tee
Support Bar
T-bar mounting bracket for 2' ceiling tiles only.
Zumtobel Lighting, Inc. ©2014
3300 Route 9W
Highland, NY 12528-2630
845-691-6262 • 800-448-4131 • zli.us@zumtobel.com
Part # D00369CI Date 04/08/14 Page 1 of 2
Ceiling Tile
by others
6
Insert tile and fixture into ceiling grid.
Mounting Bracket
Adjustable for Tiles up
to 1 1/8" thick
Questions? Problems? Call (800) 448-4131
and we will be happy to assist you. For technical
specification sheets or other information about our
products, please go to www.zumtobel.us
Installation Instructions
Important Preinstallation Note: These instructions are
for recessed LIGHT FIELDS™ to be mounted flangeless in
inaccessible (gypsum board or selected concealed) ceilings.
Plaster frame provided for gypsum board installations.
For other ceiling conditions, consult factory.
LIGHT FIELDS™ LED LFTLED 1x1
Recessed LED Fixtures
Accessible Ceilings (Lay-In and Slot-Grid)
DO NOT REMOVE THE LED GEARTRAYS. THIS WILL VOID THE WARRANTY. Call Zumtobel at 1-800-448-4131 for questions.
DA N G E R
RISK OF FIRE AND ELECTRICAL SHOCK
Contact, improper installation, or improper servicing
MAY RESULT IN DEATH OR SERIOUS INJURY!
Fixture must be installed by a qualified electrician only.
Fixture is intended for installation in accordance with
the National Electrical Code, local and federal code
specifications. Disconnect power at electrical panel
before servicing. Retain these instructions for
maintenance reference.
7
Install
1/4-20 bolt
(by others) into
the mounting
bracket.
NOTE: National or municipal codes must be followed regarding fixture installation
and set back of thermal insulating material from luminaire. As a guideline, any
insulation material must be held away from the luminaire by a minimum of 3".
Fixtures are not designed for direct contact with thermal insulation.
10
Make electrical connections through access
plate. Reinstall access plate in housing. Make
sure wires do not get caught between plate and housing.
For EM fixtures:
Install fixture following
instructions above. To mount
the remote EM pack, use the
mounting brackets (provided)
onto the adjacent grid.
8
Bend tabs on
support bar to
accomodate grid.
9
Maintenance - Turn off power first!
Attach support bar to grid, being sure to line up
the bolt in the mounting bracket with the hole in
the support bar. Bend out tabs on support bar to tighten
to the grid. Tighten bolts in mounting bracket using
washer
and nut
(by others).
1
2
3
Cleaning. Wipe with a soft, lint-free cloth to
avoid scratching the acrylic protective layer.
Do not use glass cleaner or other solvents.
Access to driver. Remove door frame as in
step 2. Remove fixture from plaster frame, and
access ballast on back of fixture.
Replacement of LED boards.
Contact Zumtobel at 1 (800) 448-4131.
WHEN REPLACING PCB ASSEMBLIES, PLEASE WEAR AN ESD
WRIST STRAP AND CONNECT IT TO THE METAL ENCLOSURE.
Zumtobel Lighting, Inc. ©2014
3300 Route 9W
Highland, NY 12528-2630
845-691-6262 • 800-448-4131 • zli.us@zumtobel.com
Part # D00369CI Date 04/08/14 Page 2 of 2
Questions? Problems? Call (800) 448-4131
and we will be happy to assist you. For technical
specification sheets or other information about our
products, please go to www.zumtobel.us
Installation Instructions
Important Preinstallation Note: These instructions are for recessed
LIGHT FIELDS™ to be mounted flangeless in inaccessible (gypsum
board or selected concealed) ceilings. Plaster frame provided for
gypsum board installations. For other ceiling conditions, consult factory.
LIGHT FIELDS™ LFULED 2'x2' Cluster
Recessed LED Fixtures
Inaccessible Ceilings,
Plaster Frame, Flangeless
DO NOT REMOVE THE LED GEARTRAYS. THIS WILL VOID THE WARRANTY. Call Zumtobel at 1-800-448-4131 for questions.
DA N G E R
RISK OF FIRE AND ELECTRICAL SHOCK
Contact, improper installation, or improper servicing
MAY RESULT IN DEATH OR SERIOUS INJURY!
Fixture must be installed by a qualified electrician only.
Fixture is intended for installation in accordance with
the National Electrical Code, local and federal code
specifications. Disconnect power at electrical panel
before servicing. Retain these instructions for
maintenance reference.
2
Install supplied
Plaster Frame into
ceiling cutout and firmly
secure all four sides to
building structure using
screws (by others).
Suspension Cable
1
Unpack fixture(s) and prepare ceiling. Fixtures are
shipped fully assembled. Make ceiling cutout (depending
on the quantity and configuration of Cluster fixtures).
Ceiling cutout =
1
2
3
4
6
9
24 13/16" SQ
24 13/16" X 48 13/16"
24 13/16" X 72 13/16"
48 13/16" SQ
48 13/16" X 72 13/16"
72 13/16" SQ
Concealed Ceiling Plaster Frame Kit,
Flangeless Appearance (PF option)
2X2 LIGHT FIELDS™
Fixture (LFU)
Fixture Support
Brackets (4)
Micro Pyramidal
Optic (MP)
wall
24" grid
3
Provide 1/4-20"
cable support from
ceiling structure to center
of frame. Tighten, making
sure all sides are level.
Cut excess cable.
24"
23 9/16"
optic frame
23 9/16" optic frame
reveal to wall
With PF Option
1 3/4"
min.
reveal to wall
9/16"
Zumtobel Lighting, Inc. ©2013
LF-5 - Zink
2x2 lightfields
recessed
17-09
Place, Unit
7 (for clusters/patterns))
Fair Lawn, NJ 07410
845-691-6262 • 800-448-4131 • zli.us@zumtobel.com
Part # D00362CI Date 02/04/13 Page 1 of 3
Gypsum
Ceiling
Plaster
Frame (PF)
24"
approx. 7/16" clearance between optic frames
Plaster frame kit
Installation,
Flangeless (PF)
Questions? Problems? Call (800) 448-4131
and we will be happy to assist you. For technical
specification sheets or other information about our
products, please go to www.zumtobel.us
Installation Instructions
Important Preinstallation Note: These instructions are for recessed
LIGHT FIELDS™ to be mounted flangeless in inaccessible (gypsum
board or selected concealed) ceilings. Plaster frame provided for
gypsum board installations. For other ceiling conditions, consult factory.
LIGHT FIELDS™ LFULED 2'x2' Cluster
Recessed Fluorescent Fixtures
Inaccessible Ceilings,
Plaster Frame, Flangeless
DO NOT REMOVE THE LED GEARTRAYS. THIS WILL VOID THE WARRANTY. Call Zumtobel at 1-800-448-4131 for questions.
DA N G E R
RISK OF FIRE AND ELECTRICAL SHOCK
9
Install multiple Cluster fixtures in the same manner.
24"
wall
Contact, improper installation, or improper servicing
MAY RESULT IN DEATH OR SERIOUS INJURY!
Fixture must be installed by a qualified electrician only.
Fixture is intended for installation in accordance with
the National Electrical Code, local and federal code
specifications. Disconnect power at electrical panel
before servicing. Retain these instructions for
maintenance reference.
24" grid
24"
4
Remove door frame
containing prismatic diffuser
by pulling up at sides until it
loosens, and then press spring
ears together until frame
detaches from housing. Keep
door frame aside in safe location.
5
6
23 9/16"
optic frame
approx. 7/16" clearance between optic frames
23 9/16" optic frame
Remove access plate from top of housing.
Attach access plate
to power supply.
Knockout in access plate
1/2" conduit (7/8" dia.).
Withreveal
PF Option
to wall 9/16"
Flexible conduit or cable
accessories by others
10
LF-5 - 2x2 lightfields recessed (for clusters/patterns))
Reattach door frame. Reinstall springs by pressing
ears together and inserting into slot or retaining bracket.
Press up on door frame until it securely clicks into fixture on all sides.
7
Make electrical connections through access plate.
Reinstall access plate in housing. Make sure wires do
not get caught between plate and housing.
8
Lift the fixture into the installed Plaster frame and
engage mounting bracket into frame. Tighten screws.
Secure to ceiling structure per local codes. Handle fixture
by sheet metal sides only. Install multiple Cluster fixtures
in the same manner.
NOTE: National or municipal codes must be followed regarding fixture installation
and set back of thermal insulating material from luminaire. As a guideline, any
insulation material must be held away from the luminaire by a minimum of 2".
Fixtures are not designed for direct contact with thermal insulation.
Zumtobel Lighting, Inc. ©2013
17-09 Zink Place, Unit 7
Fair Lawn, NJ 07410
845-691-6262 • 800-448-4131 • zli.us@zumtobel.com
Part # D00362CI Date 02/04/13 Page 2 of 2
Maintenance - Turn off power first!
1
2
3
Cleaning. Wipe with a soft, lint-free cloth to
avoid scratching the acrylic protective layer.
Do not use glass cleaner or other solvents.
Access to driver. Remove door frame as in
step 2. Remove fixture from plaster frame, and
access ballast on back of fixture.
Replacement of LED boards. Contact Zumtobel
at 1 (800) 448-4131.
WHEN REPLACING PCB ASSEMBLIES, PLEASE WEAR AN ESD
WRIST STRAP AND CONNECT IT TO THE METAL ENCLOSURE.
Questions? Problems? Call (800) 448-4131
and we will be happy to assist you. For technical
specification sheets or other information about our
products, please go to www.zumtobel.us
Download