Bruno Wall Type: ________________________ Project: ______________________ Indirect Indirect T8 SCEP Option Wall Mount S P E C I F I C AT I O N S BRW1 __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________ LAMPING OPTIONS BRW1 - 1 BRW1- 2 1 3⁄4” 1 3⁄4” 8 1⁄4” 8 1⁄4” SPECIFICATIONS Construction Finish Reflectors Electrical Nominal 8 1⁄4” x 1 3⁄4” rectangular housing is formed from cold-rolled steel. Die-cast end caps are mechanically attached with no exposed fasteners. Die-formed white painted reflector. Luminaire Length Fine-textured, white polyester powder paint is standard. Consult factory for special finish requirements. 4’ 1⁄16”, 8’ and 12’ lengths in a single section. For total luminaire length, add 5⁄8” for each flat end cap and 4” for each sculptured end cap. Using internal joiners, 4’, 8’ and 12’ sections can be joined to form longer rows. Specify 120V, 277V or 347V. Pre-wired with 16AWG fixture wires. For special circuiting or wire gauge, consult factory. Plug-in electrical connectors included. UL and C-UL listed. CATALOG NUMBER Examples: __________ BRW1 2 32 WHR 40FT R8 120 GEB10 DCT LP835 C210 SCEP — BRW1 2 32 WHR 32FT R8 277 GEB10 1SE EL DCT LP835 C110 __________ Luminaire # of Lamps in Cross Section BRW1 __________ __________ _________ __________ __________ __________ __________ Lamp Type Reflector Ballast Type # of Emergency Modules WHRWhite reflector Maximum Section Length Voltage 32 Luminaire Row Length X FT (4’ increments) R4 R8 R12 120 277 347 GEB10 <10% THD Electronic ADEZ1 Advance Mark 10 dim DMHL3D1 Lutron Hi-Lume dim ADZT1Advance Mark 7 0-10V dim (Blank)None 1SE 1 section 2SE 2 sections XSE X sections 32W T8 1 2 4’ section(s) 8’ section(s) 12’ section(s) Reference Ballast Wizard on website or consult factory for other options. ________________ ________________ ______________ _________________________________ Emergency Type2 ______________ Switching Lamp Color Finish Options (Blank)None EC Emergency circuit EL1 Emergency battery pack EN1 Emergency battery pack w/night light circuit SCT DCT L/LP No lamp L/LPENo lamp. Wired for energy saving lamps. LP830 3000K 80+ CRI LP835 3500K 80+ CRI LP841 4100K 80+ CRI C110 DL DU ELH ELS ELS2 GLR GMF NYC SCEP Single circuit Dual circuit Reference Lamp Chart on website or consult factory for other options. Painted aluminum (low gloss) C210 White white (fine-textured low gloss) C099 Custom finish Damp location label Dust cover Emergency through wiring w/separate feed Emergency through wiring w/single feed, shared neutral Emergency through wiring w/single feed, separate neutrals Fusing (fast blow) Fusing (slow blow) New York City code Sculptured end cap Notes: 1 Not available in 347V 2 Emergency type is installed in last 4’ of luminaire sections. Separate feed required unless ELS or ELS2 is specified 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx BRW1 Bruno Wall Indirect T8 1 Bruno Wall Indirect Type: ________________________ Project: ______________________ Indirect T8 Wall Mount BRW1 MOUNTING DETAIL 2 x 4 switch box — by others feed cover 2 13⁄16" mounting bracket feed cover mounting holes for 1 ⁄4" bolt ⁄16" ⁄4" 11 3 mounting bracket (2) #10-24 mounting screws 1 1⁄2 " to bottom of housing ⁄4 " 3 10" (2)1⁄4 " diameter mounting bolts — by others WEIGHTS & SUPPORT SPACING STANDARD SECTIONS 2 13⁄16” typical Key: ⁄8” standard flat end caps 4” optional sculptured end caps 5 2’-8” 16 LBS Support location Standard feed location EM feed location • 4’-1 ⁄16” O.A. 5 3’-4” 34 LBS 3’-4” 8’-1 1⁄4” O.A. 4’-0” 2’-8” 4’-0” 55 LBS 12’-1 1⁄4” O.A. ELEVATION CONFIGURATIONS Tenon inside, outside and straight connectors available for wall configurations. Reference Pattern Connector Guide for additional details. PHOTOMETRICS Actual performance may differ as a result of end-user environment and application. 1-LAMP T8 61.1% efficiency 1742 delivered lumens 2-LAMP T8 65.8% efficiency 3748 delivered lumens 100.0% up / 0.0% down 100.0% up / 0.0% down 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx BRW1 Bruno Wall Indirect T8 2