CEDG Surface 2013 - Carpenter Emergency Lighting

advertisement
Fixture Type:
Model Number:
Project:
CEDG Series
Surface Edge Lit Exit Signs
ORDERING GUIDE
CEDG-AC
MODEL
CEDGAC AC only
CEDGSP Battery back up
-R -SC-UA -1C -6 -W -DR
LETTER SIZE
ARROWS
LETTER
6
8
NA No Arrows
UA Universal
R Red
G Green
MOUNTING
SC Surface (Ceiling/End)
SW Surface Wall*
* 1C Panels only
6 Inches
8 inches
PANEL
HOUSING
1C
1W
2W
1M
2M
W White
B Black
Single/Clear
Single/White
Double/White
Single/Mylar
Double/Mylar
OPTIONS
2CK Dual Circuit
RT Remote test
FBZ Flasher and
buzzer
SW Special
Wording
PMK Pendant
Mount Kit
SPECIFICATIONS
Construction
Housing is constructed heavy duty steel with a bright
white finish. Other colors available.
STANDARD FEATURES
All Models
 Universal 120/277 volt 60 Hz field selectable

input
Heavy duty steel construction with a bright white
finish
Easy to install construction
Low profile housing
Long Life LED lamps provide bright and even
illumination.
Low power consumption
Red or Green Exit letters
White housing (Black is optional)
Stick on, chevron type, directional arrows.
Available as wall, ceiling or end mounting.
Available in single or double models
Installation
Housing is provided with web pattern for end, wall, or
ceiling mount.
Illumination
All models are illuminated with high intensity red or
green LEDs and meet UL requirements for uniformity.
Electronics
Universal 120/277 volts 60hz input. AC lock out and low
voltage disconnect.
Power
Consumption
AC models - 3.5 watts @ 120/277 volts
Emergency models - 4.2 watts @ 120/277 volts
Battery
Sealed NiCad battery - Provides a minimum of 90
minutes of emergency operation






Code
Compliance
ETL Listed to UL924. Meets or exceeds the requirements
of the National Code and NFPA101
Emergency Models
 Premium nickel cadmium maintenance free
Warranty
One year warranty from date of shipment on entire unit. 7
year pro rata warranty on the batteries. See Warranty
Statement for details.
DIMENSIONS
4”
7 1/8”
2¾”
14”
12”
RT - Remote test
(Optional)
Allows user to initiate a momentary test of the emergency
lighting from up to 20 feet
away.















battery
90 minutes of emergency illumination
Fully automatic solid state charger
Recharge times as per UL guidelines
Solid state relay supervision
Low battery voltage disconnect
AC lockout circuit reduces installation time
Brownout protection.
AC ready LED indicator
Momentary test switch.
Operating range 68°F to 86°F
Remote test (Optional)
MADE IN THE USA
Note: 8 inch letters increase panel height to 8¾”
Carpenter Emergency Lighting
Phone: 609-689-3090 Fax: 609-689-3091
All specifications subject to change without notice
2 Marlen Dr., Hamilton, NJ 08691
www.carpenterlighting.com
P/N 99-1006 - 2014 Rev 3