Analytical Report for E-Liquid Samples Certificate Number Method: GCMS/FID Date of receipt ################# Instrument: 7890B-5977 Date of report 5-Sep-16 Expiry Date #NAME? R2544 Batch Number ZAP8700 Product Name ZEST APPEAL 0mg ZAP8700 Mode of Detection GC-MS (SIM) Compound Diacetyl Acetyl Propionyl Acetoin Ethylene Glycol Diethylene Glycol Nicotine Concentration Units ppm ppm ppm ppm ppm Result Not Detected Not Detected Not Detected Not Detected Not Detected mg/mL Not Detected Propylene Glycol Glycerin 87 Limit of Detection 1 1 1 10 10 0.001 GC-FID PG:VG Ratio 13 Figure 1. GC-MS (SIM) chromatogram of sample. Abundance Diphenylamine TIC: ZEST APPEAL 0mg ZAP8700.D\datasim.ms 900000 800000 600000 500000 400000 300000 200000 100000 Glycerin Propylene Glycol 700000 6.00 7.00 8.00 9.00 10.0011.0012.0013.0014.0015.0016.0017.0018.00 Time--> Figure 2. GC-FID chromatogram of sample. Abundance Signal: ZEST APPEAL 0mg ZAP8700.D\FID1A.ch 3500000 3000000 2500000 - 2000000 1500000 1000000 500000 6.00 7.00 8.00 9.00 10.0011.0012.0013.0014.0015.0016.0017.0018.00 Time--> Page 1 of 2 C:\GCMS\custrpt\ECIG SIM FID GENERAL.CRT 5/9/2016 10:27 AM Figure 3: GC-MS Total Scan (Total Ion Chromatogram) of sample Abundance TIC: ZEST APPEAL 0mg ZAP8700.D\data.ms 900000 800000 700000 600000 500000 400000 300000 200000 100000 6.00 7.00 8.00 9.00 10.0011.0012.0013.0014.0015.0016.0017.0018.00 Time--> GENERAL REPORT NOTES: This report only relates to the Lot/batch number and sample name given above. Each sample has been analysed as received and so the lab does not bear any responsibility for variations in expected results due to inappropriate packaging, storage and transportation prior to receipt. All samples, upon receipt, are secured within access controlled storage. Samples are analysed within quality controlled batches. Each batch consists of a set of matrix-matched control standards; independent standards; and internal calibration standard. The target compounds used are sourced from ISO Guide 34 compliant suppliers where possible; and the dilution/preparing of the calibration solutions were prepared in accordance to in-house procedures. The metrological traceability of the gravimetric measurements employed in the analytical technique is assured in accordance to ISO/IEC 17025. The analytical balance employed was first checked before use with class E2 analytical weights, traceable to DKD. Cold storage is maintained within set limits (5±3°C) and monitored daily using calibrated thermometers that are NIST traceable. The hyphenated analytical technique employed was Gas Chromatography with Mass Spectrometer and Flame Ionisation Detection (GC-MS-FID). The quality control measures employed within each batch ensures that each analysis is acceptable to ±10% of the true value. COMMON NAME Diacetyl Acetyl Propionyl Acetoin Ethylene Glycol Diethylene Glycol Propylene Glycol Glycerin Nicotine Diphenylamine CHEMICAL NAME 2,3-Butanedione 2,3-Pentanedione 3-Hydroxybutan-2-one 1,2-Ethanediol Bis(2-Hydroxyethyl)ether 1,2-Propanediol 1,2,3-Propanetriol 3-[(2S)-1-methylpyrrolidin-2-yl]pyridine N-Phenylalinine CAS No. 431-03-8 600-14-6 513-86-0 37221-95-7 111-46-6 190913-75-8 29796-42-7 54-11-5 122-39-4 Definitions: Not Detected: Target compound is less than the method detection limit or limit of quantification. If limits of detection are different from that quoted, a caveat will be included in the comment section of the report. Limit of Detection: The least amount of a target substance that can be clearly differentiated from other components within the same matrix and distinguished from a blank sample. Analysed by: Approved by: Contact Phone: Richard Gandon Kenoye Muzan 01733 562 322 Sequence File Path: D:\Routine\Routine 249\ This report has been generated by Electronic Cigarettes LTD Unit 3 Fengate Trade Park, Peterborough, PE1 5XA Page 2 of 2 C:\GCMS\custrpt\ECIG SIM FID GENERAL.CRT 5/9/2016 10:27 AM