PROJECT INFORMATION MEDMASTER™ Patient Room Luminaires Job Name Fixture Type MPCAE24 SERIES Catalog Number Approved by PRODUCT FEATURES: »» Ceiling mount – surface, grid or flange; 2'×4' »» Provides ambient and exam lighting »» Optional Ingress Barrier Door provides consistent surface for cleanability SPECIFICATIONS HOUSING: FLANGE AND GRID: 20-gauge CRS one-piece construction (IB is one piece seam welded construction). SURFACE: 18-gauge CRS one-piece seam welded construction. Housing Flange: FLANGE AND GRID: 18-gauge CRS, standard 4-piece construction, spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded to housing. Housing Finish: White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. INSIDE FLANGES: 18-gauge CRS; fastened to housing. Black matte TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours. OPTIONAL DOORFRAME: IB-AC OR IB-HD OPTIONS ONLY. Heavy duty extruded aluminum with clear satin anodized finish. Doorframe supported to housing with aircraft cables (IB-AC) to provide NSF2 listing, or an optional continuous hinged doorframe (IB-HD). Select in ordering options below. Doorframe secured to housing with continuous hinge (20-gauge SS) and Phillips-head stainless steel fasteners. Closed cell silicone gasket seals doorframe to housing. LAMP SHIELDING: Exam compartment shielded by sliding semi-specular aluminum parabolic louver. C ­ lear protective lamp shield securely fastened above louver (see Ordering Information for alternate Lamp Shield Options). Ambient compartment lamps shielded by perforated steel (white TGIC polyester powder coat finish) with pearlescent acrylic diffuser. Note: Exam compartment clear protective lamp shield omitted when IB Option is specified. ELECTRICAL: Fluorescent electronic 120/277V ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps by others. CL Option field adjustable to either side of bed. One 20W maximum, 12VAC, MR16, 120 or 277 volts. 8° narrow spot recommended. Exam area NEC compliant with isolated wiring compartment for auxiliary branch circuit feed. INSTALLATION: SURFACE MOUNT: Four .312" diameter holes. GRID MOUNT: Designed for 1" and 1.5" grid. (Housing includes hanging brackets to secure housing with wire to super structure). FLANGE MOUNT: Yoke mounting hardware & brackets included. Install Frame and Plaster Frames both positively locates yoke brackets within ceiling opening assures alignment of fixture. Install frame has no need for drywall backing. Backing is supplied on the frame brackets. LISTINGS: UL and CUL Listed for Damp Location. IB Option UL certified IP65 per IEC 60598. IP65 OPTION IB-AC ONLY ORDERING INFORMATION (Ex: MPCAE24-S-1/3-40B-120-L) Model Mounting Options Lamp Qty MPCAE24 Lamp Type Voltage Lamp Shield Options Doorframe Options Accessories / Mounting Options SSurface G Grid (1") FFlange Lamp Type 40B F40TT (Biax) 50B F50TT (Biax) 55B F55TT (Biax) Lamp Quantity (x/x) Ambient Compartment (x) 1 One Lamp 2 Two Lamps Exam Compartment (x) 3 Three Lamps 4 Four Lamps Voltage 120 120 Volts 277 277 Volts 347 347 Volts Optional Doorframe IB-AC* Ingress Barrier w/Aircraft Cables IB-HD* Ingress Barrier w/Continuous Piano Hinge (not NSF2 listed) Lamp Shield Options (Exam Section) L Semi-Specular Aluminum Parabolic 3"×3" Louver with clear acrylic lamp shield CMetalized Acrylic Parabolic .62" x.62" Louver with clear acrylic lamp shield LW Matte White 3"×3" Louver with clear acrylic lamp shield I .125" #12 Prismatic Acrylic SL Specified Louver Options AMF Antimicrobial Finish on exposed surfaces CL* Chart Light – 20W MR16 DLN▲ LED Night Light w/Light Level Control(Lamp by other) (100% - 20%) EL One-Lamp Emergency Battery Pack (32°F) (347V dry location only) – Ambient only FS Fuse & Holder LCL* LED Chart Light LVC▲ Low Voltage Controller (See Application Guide or consult factory for switching options) RF▲ Radio Frequency Filter TN▲ Night Light – 5/7/9 Watt PL (Lamp supplied by other) Accessories C-2063 Lamp, 20W MR16 12VAC 8° Spot IF Install Frame (Flange only) *Only available with L or LW Lamp Shield Option ▲ n/a with 347V www.kenall.com P: 800-4-Kenall F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. MPCAE24-020414 For additional photometry, go to www.kenall.com MEDMASTER™ Patient Room Luminaires MPCAE24 SERIES DIMENSIONAL DATA CROSS SECTION B A C CEILING CUTOUT D E DIMENSIONAL DATA (IN INCHES) A B C DE MPCAE24 5.80* 23.00×47.00 23.75×47.7523.25** 47.25** *Add .25" to fixture height when Ingress Barrier (IB) Option is specified **Add .25" to each cut-out dimension when Install Frame (IF) Accessory is specified www.kenall.com P: 800-4-Kenall F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. MPCAE24-020414