Installation Instructions ADVANCED HIGH CEILING 16” Cylinder Series ! IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Before wiring to power supply and during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard. Product must be at locations and at heights and in a manner consistent with its intended use, and in compliance with Electrical Code and local codes. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. 7 8” 1. Remove fixture and all components from box. 2. Connect power input wires with corresponding blue/brown/green wires using attached connector at end of wires. Install cable clamp connector(required, but not included) Push connected wires through cable clamp connector. Clamp to secure. 3. Secure stem (by others) to bracket with two hex nuts (by others) as shown. METEOR LIGHTING P: 213.255.2060 F: 213.596.3704 www.meteor-lighting.com INC01S01-16 V1.1 | Page 1 of 4 *METEOR LIGHTING reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. Installation Instructions ADVANCED HIGH CEILING 16” Cylinder Series Pendant (Adjustable Aircraft) Mounting Hole Junction Box 1 3 Crossbar Ground Screw Stud 7 4 Canopy Terminal Strain Relief Bushing 2 Coupler Cable 8 Gripper 6 2 Piece Cable Puck Half ball end 5 1/16” Cable 9 1. Secure the crossbar to the 4" octagonal box (by others) designed to support the weight of the fixture. 2. Insert power feed cord through canopy wire hole and secure with strain relief bushing. Leave sufficient length to make wire connections. 3. Make ground connection to the ground screw on crossbar. Connect line voltage to the Black conductor, neutral to the White conductor. For 0-10V dimming option, make connections (Data+ to Purple conductor and Data- to Gray conductor). 4. Thread the cable through the coupler (the terminal side of cable must be on top). Slide the coupler up to the canopy and secure with the stud on crossbar. 5. Lay half ball end cables into lower section of cable puck. 6. Attach upper section of puck over top of bottom of puck aligning power cord holes of upper and lower section of puck. And secure gripper into top of puck completing puck assembly. 7. Attach puck assembly to fixture by dropping paddle ends of cables into the 3 holes on the back of the fixture. 8. Insert the cable through the gripper on top of puck. Adjust to desired height. Thread Cable thru both holes in Cable Locking Tube and tighten set screws. 9. Insert the cord through the puck. Trim cord to suitable length and make electric connection in the junction box for fixture. Paddle METEOR LIGHTING P: 213.255.2060 F: 213.596.3704 www.meteor-lighting.com INC01S01-16 V1.1 | Page 2 of 4 *METEOR LIGHTING reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. Installation Instructions ADVANCED HIGH CEILING 16” Cylinder Series Wiring diagram Superior 0-10V Superior 0-10V Dimming wire Power wire BLUE / VIOLET- POSITIVE Superior 0-10V Dimming WHITE / GRAY- NEGATIVE DMX Power wire BLUE - NATURAL BROWN - LINE GREEN - GROUND AC WIRE Standard DMX512 Wire with 5 pin in/out Connector (not included) DMX address DMX512 is connected using a daisy-chain methodology where the source connects to the input of the first device, the output of the first device connects to the input of the next device, and so on. METEOR LIGHTING P: 213.255.2060 F: 213.596.3704 www.meteor-lighting.com INC01S01-16 V1.1 | Page 3 of 4 *METEOR LIGHTING reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately. Installation Instructions ADVANCED HIGH CEILING 16” Cylinder Series DMX Power Supply Box Installation & Electrical Connection Power Supply: Before making electrical connections, be sure the AC voltage in your area matches the required voltage for the purchased Meteor LED fixture. Because the line voltage may vary from venue to venue, you should be sure your unit voltage matches the wall outlet voltage before attempting to operate the fixture. DMX-512: DMX stands for Digital Multiplex Signal. It is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR connector located on our power supply box. DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. DMX512 is connected using a daisy-chain methodology where the source connects to the input of the first device, the output of the first device connects to the input of the next device, and so on. Network can be expanded across parallel buses using DMX splitters. Daisy Chain Layout (DMX) ! Electrical System WARNING 1. Before installation, please test LED fixture with DMX function on ground to ensure compatibility with control console. 2. DMX address is listed on power box. If DMX address needs to be reset, please contact our technical department for further instructions. 3. Our lights require its own channel. If using different fixture type, please use splitter device to separate. 4. The final fixture should be terminated by the use of DMX Terminator (by others). DMX IN Standard DMX512 Wire Cable with 5 Pin In/Out Connector DMX IN DM X The dotted lines represent AC power circuits DMX OUT DMX OUT DMX IN DMX IN Splitter DMX Console METEOR LIGHTING P: 213.255.2060 F: 213.596.3704 www.meteor-lighting.com INC01S01-16 V1.1 | Page 4 of 4 *METEOR LIGHTING reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.