EDGE EV6A E V O L U T I O N LED Recessed Linear with Satine Lens Project Name Date Catalog Number Type CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflective die-formed white painted steel reflector, .125” (3.2mm) white snap-in acrylic lens with matte finish, removable for maintenance. ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard. Must specify 1D in circuiting for dimming. LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. R9≥20, 27K is CRI≥90, 30K, 35K, and 40K is CRI≥82. Minimum lifetime greater than 60,000 hours. MOUNTING Edge is designed to install into acoustical grid and inaccessible ceilings. Specify GXG, FLF, SFS, NFN for individual, unjoinable units (individual units will fall on-grid). Specify GX, FL, SF, NF for continuous runs (runs designed to fall on-grid). Grid retention brackets are integral to housing. Each housing contains 4 grid retention brackets. Consult factory for detailed installation instructions. FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish, consult factory for chip of standard paint finishes. Contact factory for additional custom color and finish options. WARRANTY Edge LED offered with a 5-year limited warranty. Covers LED, driver and fixture. LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted. YEAR LED WARRANTY 5-3/4” 5-3/4 (146.1mm) Daylight Sensor MR16 Corners LFL Convertible LED (146.1m LED Convertible YEAR LED WARRANTY LFL 1” 5” (127mm) LFL Grid: 5-13/16” (147.6mm) LED Convertible Convertible FL: 6-1/8” LED (155.6mm) LFL L U M I N A I R E S P E C I F I C AT I O N 5” (127mm) Grid: 5-13/16” (147.6mm) FL: 6-1/8” (155.6mm) Sample Catalog #: EV6A-30-24’-FL-120-1C-W EV6A- ____- ___’- ___- HOUSING COLOR/LUMENS LENGTH MOUNTING ___- __- YEAR LED WARRANTY VOLTAGE 1 LFL Convertible EV6A- Edge Evolution 6, Satine Lens (25.4mm) LED CIRCUITING LED __- ____ FINISH OPTIONS 5-3/4” Convertible (146.1mm) LFL 1C- Single Circuit 1D- Single Circuit Dimming5 1B- Single Circuit with Battery Pack5,6 5” (127mm) 1E- Single Cirtuit with Grid: 5-13/16” (147.6mm) Emergency Circuit Lamps FL: 6-1/8” (155.6mm) 3 Individual Units (CANNOT BE JOINED)2 Continuous Runs xx’- SpecifyLFL row length to 1’ increments LED Acoustical Grid Ceiling13 Convertible ConvertibleG1G- 1” (25.4mm) Ceiling Grid (Utilize Illuminated [EI] or Non-Illuminated 27K Color Temperature Lumen Options LED LFL [EN] Extension in the Options section to G9G- 9/16” (14.3mm) Ceiling Grid Staggered 27- 27K, 370 lumens/ft (5.2 watts/ft) Lamps specify rows to 1/8” increments) GBG- 9/16” (14.3mm) Ceiling Grid with Bevel Trim 27HO- 27K, Installation 673 lumens/ft (10.1 watts/ft) Instructions GSG- Screw Slot Ceiling Grid 30K Color Temperature Lumen Options Inaccessible Ceiling 30- 30K, 450 lumens/ft (5.2 watts/ft) FLF- Standard 1/2” (12.7mm) Flange5-3/4” 30HO- 30K, 819 lumens/ft (10.1 watts/ft) (146.1mm) W- Matte White SFS- Spackle Flange 35K Color Temperature Lumen Options 4 S- Metallic Silver NFN- Flangeless Year LED 35- 35K, 470 lumens/ft (5.2 watts/ft) Warranty BL- Textured Black Continuous Runs (JOINABLE)3 35HO- 35K, 855 lumens/ft (10.1 watts/ft) GR- Graphite 13 Acoustical Grid Ceiling BR- Bronze G1- 1” (25.4mm) Ceiling Grid 40K Color Temperature Lumen Options LFL LED 5” (127mm) CC- Custom Color G99/16” (14.3mm) Ceiling Grid 40- 40K, 482 lumens/ft (5.2 watts/ft) Convertible Convertible 5-13/16” (147.6mm) LED LFL GB- 9/16”Grid: (14.3mm) Ceiling Grid with Bevel Trim 40HO- 40K, 877 lumens/ft (10.1 watts/ft) 6-1/8” (155.6mm) GS- Screw FL: Slot Ceiling Grid Custom Output Inaccessible Ceiling CL_____- Specify color temp. and lumens/ft. (i.e. CL35600) FL- Standard 1/2” (12.7) Flange CW____- Specify color temp. and wattage/ft. (i.e. CW407.5) SF- Spackle Flange (Specify lumens/watts between standard offering listed above. NF- Flangeless4 Lumens are specified per color temp.) Individual Units2 2- 2’, 23” (584.2mm) fixture2 3- 3’, 35” (889mm) fixture2 4- 4’, 47” (1193.8mm) fixture2 6- 6’, 71” (1803.4mm) fixture2 YEAR LED WARRANTY 2 Staggered8- 8’, 95” (2413mm) fixture 120- 120 V 277- 277 V UNV- UNV (120-277) QSCPMRFLMRFXLEDMRA- Quick Ship12 Chicago Plenum Fixed MR16 Halogen9 Fixed MR16 LED9 Fixed Xicato LED9 Adjustable MR16 Halogen9 LMRA Adjustable MR16 LED9 PMPerimeter Mount7 RCRotating Crossbar8 EV6CH- 90° Horizontal Corner10 EV6CI- 90° Inside Corner10 EV6CO- 90° Outside Corner10 EI__- Factory Installed Illuminated Extension11 EN__- Factory Installed NonIlluminated Extension13 See back page for mounting detail. 2Individual units cannot be joined. All end trims are factory installed and cannot be removed in the field. 3Continuous Rows made up of both even and odd length fixtures. Designed to fall on-grid. 4NF and NFN to be utilized for metal pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Integral battery packs with remote test switch are provided with 1B option. 7Available for acoustical grid ceilings. Wall rail painted white unless otherwise specified. 81/2” to 5/8” drywall thickness. Available for standard 1/2” flange (FL). 9Consult MR16 Resource Guide for configurations using MR16 units. 10See EV6 Corner Specification sheets for more information. 11Use “__” to specify desired length. Minimum length is 3”. Sample part number EV6A-27-24-G1-120-1C-W-EI4 for order a 24’-4” run. 12Includes EV3A, 4 ft individual, unjoinable units, G1G and FLF mounts, universal voltage, std white finish, 1C and 2C circuiting. 13 Use “__” to specify desired length. Minimum length is .5”. Sample part number EV6A-27-24-G1-120-1C-W-EN2 for order a 24’-2” run. 14 See page 3 for grid retention bracket details. 1 ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® July 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. PHOTOMETRY EDGE EVOLUTION EV6C, EV6D 765 2' 1383 23" (584.2mm) 574 1045 383 (1) lens per 2'191 unit Side View 697 348 35" (889mm) 71” (1803.4mm) or 72” (1828.8mm) 6' 3' (1) lens per 3' unit (1) lens per 6' unit 47” (1193.8mm) or 48” (1219.2mm) 95” (2413mm) or 96” (2438.4mm) 4' 8' Test #: ITL82394 Test #: ITL82395 (1) lens per 8' unit (1) lens per 4' unit Part #: EV6A-40-4’ Part #: EV6A-40HO-4’ 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. Lumens per watt: 94 Lumens per watt: 87 Total Delivered Lumens: 1,927 Total Delivered Lumens: 3,507 EV6A, EV6H, EV6AL INDIVIDUAL AND CONTINUOUS RUN MODULES 1 23" (584.2mm) Side View 2' (1) lens per 2' unit 3' 35" (889mm) (1) lens per 3' unit 4' 71” (1803.4mm) or 72” (1828.8mm) 6' (1) lens per 6' unit 47” (1193.8mm) or 48” (1219.2mm) 95” (2413mm) or 96” (2438.4mm) 8' (1) lens per 8' unit (1) lens per 4' unit 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. MOUNTING DETAILS EV6P 1” Grid Mounting Options 9/16” Grid Mounting Side ViewsOptions 48”, 72”, 96” 23" Screw Slot Mounting 23”, 35”, 47”, 71”, 95” 2' (1) louver per 2' unit 35" 71” or 72” 6' 3' (1) louver per 3' unit (2) louvers per 6' unit 1” Grid, Standard Tile: Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: Screw Slot Grid: 47” or1”48” 95” or 9/16” 96” Grid, Tegular Tile: Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part # 4' 8' (2) louvers per 8' unit (1) louver per 4' unit INACCESSIBLE MOUNTING SPECIALTY MOUNTS 1Acoustical Grid Ceiling andCEILING Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. Flange Detail Non-Flange Spackle Flange Exposed Flange Detail: Metal Pan or Millwork: Drywall, Flangeless Look: Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part # MR16 LAMP APPLICATION: MR16’s are ideal for conference rooms, corridors, wall washing, retail spaces and training facilities where accent lighting is required. Perimeter Mount Rotating Crossbar Bracket and Wall Rail: Specify PM in part # Unavailable Structure Support: Specify RC in part # ELECTRICAL: Standard 50 watt max halogen lamp transformer (120v or 277v), 60 watt max LED electronic transformer (120v or 277v). MR16 installed as independent circuit. MR16 voltage to match LED voltage. LABELS: UL and cUL Listed, approved for dry/damp location unless othTECHNICAL: MR16 fully enclosed compartment elimierwise noted. nates light from entering into other fixture areas. Availin 20, 35 and 50 watt halogen lamps, up to9/16” 12 watt ORDERING INFORMATION: MR16’s should be specified utilizing 1” Grid Mounting able Options Grid Mounting Options Screw Slot LED lamps (lamps not included). Consult factory for other lamp types/ wattages. MR16 layout guide. Mounting ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® July 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. 1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: Screw Slot Grid: GRID RETENTION BRACKET EDGE EVOLUTION Joint holes Joint for holes #8-32 for #8-32 ScrewsScrews GRID RETENTION: At every joint, the addition of grid retention brackets results in a sturdy connection between the fixtures and the grid. Insert screws through the bracket into the grid to secure. JOINT ALIGNMENT: Incorporating biscuits and screws not only creates a secure joint but also aids in fixture alignment. BiscuitBiscuit ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® July 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.