EDGE EV3CI
E V O L U T I O N
LED EV3 Inside Corner
For use with Edge Evolution 3 LED
Project Name
Date
Catalog Number
Type
CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflec-
tive die-formed white painted steel reflector, .125” white snap-in acrylic lens with matte finish, removable for lamp
replacement.
ELECTRICAL Electronic, 120 to 277 volt input and 24V output. 0-10 volt dimming standard.
LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80.
R9≥20, CRI≥82. Minimum lifetime greater than 60,000 hours.
MOUNTING Edge is designed to install into acoustical grid and inaccessible ceilings. Specify entire wall to ceiling
configuration below. For in-wall component, specify IW or IWS. For ceiling component, specify GX, FL, SF or NF. Inside
corner units easily join to in-wall and ceiling fixtures. Grid retention brackets are integral to housing. Each housing
contains 4 grid retention brackets. Consult factory for detailed installation instructions.
FINISH Standard powder-coat textured white, metallic silver, textured black, graphite, or bronze painted finish on
exposed trim, consult factory for custom colors.
WARRANTY Edge LED offered with a 5-year limited warranty. Covers LED, driver and fixture.
LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted.
Utilize EV3CI Specification sheet for Specifying
entire row configuration with corner.
5-1/8”
4-1/2”
YEAR LED
WARRANTY
LFL
LED
Convertible
3”
LFL
Convertible
Convertible
LED
G1/G9/GS:
5-1/8”
YEAR LED
WARRANTY
LFL
LED
LED
Convertible
Standard
EV3
LFL
3”
G1/G9/GS:
3-13/16”
FL : 4-1/8”
3-13/16”
FL & FLF: 4”
4-1/2”
See back page for more details.
L U M I N A I R E S P E C I F I C AT I O N
Sample Catalog #: EV3CI-30HO-8’/24’-IWS/FL-120-1C-W
EV3CI-
____-
__/__-
HOUSING
COLOR/LUMENS
WALL/CEILING LENGTH
YEAR LED
WARRANTY
__/__-
WALL/CEILING
MOUNTING
LFL
LED
Convertible
LED
EV3CI- Edge
Evolution 3
Inside 90˚
Corner, Satine
Lens6
27K Color Temperature Lumen Options
27- 27K, 373 lumens/ft (6.2 watts/ft)
27HO- 27K, 697 lumens/ft (13.1 watts/ft)
30K Color Temperature Lumen Options
30- 30K, 399 lumens/ft (6.2 watts/ft)
30HO- 30K, 746 lumens/ft (13.1 watts/ft)
35K Color Temperature Lumen Options
35- 35K, 408 lumens/ft (6.2 watts/ft)
35HO- 35K, 762 lumens/ft (13.1 watts/ft)
40K Color Temperature Lumen Options
40- 40K, 425 lumens/ft (6.2 watts/ft)
40HO- 40K, 795 lumens/ft (13.1 watts/ft)
In-Wall Component
Individual Units
2- 2’, 23” fixture
3- 3’, 35” fixture
4- 4’, 47” fixture
6- 6’, 71” fixture
8- 8’, 95” fixture
Continuous Runs1
xx’- Specify nominal overall row
length in 1’ increments
Ceiling Component
Individual Units
2- 2’, 23” fixture
3- 3’, 35” fixture
4- 4’, 47” fixture
6- 6’, 71” fixture
8- 8’, 95” fixture
Continuous Runs1
xx’- Specify nominal overall row
length in 1’ increments
Convertible
___-
__-
__-
VOLTAGE
CIRCUITING
FINISH
LFL
In-Wall Component
IW- Standard 1/2” Flange
IWS- Spackle Flange
120- 120 V
Ceiling Component
277- 277 V
Acoustical Grid Ceiling7
UNV- UNV3
G1- 1” Ceiling Grid
(120-277)
G9- 9/16” Ceiling Grid
GB- 9/16” Ceiling Grid with Bevel Trim
GS- Screw Slot Ceiling Grid
Inaccessible Ceiling
FL- Standard 1/2” Flange
SF- Spackle Flange
NF- Flangeless2
W- Matte
White
S- Metallic
Silver
BL- Textured
Black
GR- Graphite
BR- Bronze
CC- Custom
Color
1C- Single Circuit
1D- Single Circuit Dimming4
1B- Single Circuit with
Battery Pack3, 4, 5
Custom Output
CL_____- Specify color temp. and lumens/ft. (i.e. CL35600)
CW____- Specify color temp. and wattage/ft. (i.e. CW407.5)
(Specify lumens/watts between standard offering listed above.
Lumens are specified per color temp.)
Continuous Rows made up of both even and odd length fixtures. Ceiling fixtures designed to fall on-grid. 2NF to be utilized for metal pan / millwork ceiling. 3UNV not available with battery pack. 4Some
Edge configurations will not accommodate all electrical options. Consult factory. 5Integral battery packs with remote test switch are provided with 1B option. 6Corner available with satine lens only. 7See
page 3 for grid retention bracket details.
1
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting®
February 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
EDGE EVOLUTION 3 / 90º INSIDE CORNER
MOUNTING DETAILS
1” Grid Mounting Options
9/16” Grid Mounting Options
Screw Slot
Mounting
1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile:
Screw Slot Grid:
Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part #
Flange Detail
Non-Flange
Spackle Flange
Exposed Flange Detail:
Metal Pan or Millwork:
Drywall, Flangeless Look:
Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part #
LAYOUT
Edge Evolution 3 LED
1” Grid Mounting Options
9/16” Grid Mounting Options
Screw Slot
Mounting
Inside Corner
Assembly
1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile:
Screw Slot Grid:
Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part #
Flange Detail
Non-Flange
Spackle Flange
Edge Evolution 3 LED
Exposed Flange Detail:
Metal Pan or Millwork:
Drywall, Flangeless Look:
Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part #
Corner Mounting
Screw
Inside Corner
Assembly
Wire Chase
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting®
February 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
GRID RETENTION BRACKET
EDGE EVOLUTION 3 / 90º INSIDE CORNER
Joint holes
Joint for
holes
#8-32
for #8-32
ScrewsScrews
GRID RETENTION: At every
joint, the addition of grid
retention brackets results in
a sturdy connection between
the fixtures and the grid.
Insert screws through the
bracket into the grid to
secure.
JOINT ALIGNMENT: Incorporating biscuits and screws
not only creates a secure
joint but also aids in fixture
alignment.
BiscuitBiscuit
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting®