EDGE EV3CI E V O L U T I O N LED EV3 Inside Corner For use with Edge Evolution 3 LED Project Name Date Catalog Number Type CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflec- tive die-formed white painted steel reflector, .125” white snap-in acrylic lens with matte finish, removable for lamp replacement. ELECTRICAL Electronic, 120 to 277 volt input and 24V output. 0-10 volt dimming standard. LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. R9≥20, CRI≥82. Minimum lifetime greater than 60,000 hours. MOUNTING Edge is designed to install into acoustical grid and inaccessible ceilings. Specify entire wall to ceiling configuration below. For in-wall component, specify IW or IWS. For ceiling component, specify GX, FL, SF or NF. Inside corner units easily join to in-wall and ceiling fixtures. Grid retention brackets are integral to housing. Each housing contains 4 grid retention brackets. Consult factory for detailed installation instructions. FINISH Standard powder-coat textured white, metallic silver, textured black, graphite, or bronze painted finish on exposed trim, consult factory for custom colors. WARRANTY Edge LED offered with a 5-year limited warranty. Covers LED, driver and fixture. LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted. Utilize EV3CI Specification sheet for Specifying entire row configuration with corner. 5-1/8” 4-1/2” YEAR LED WARRANTY LFL LED Convertible 3” LFL Convertible Convertible LED G1/G9/GS: 5-1/8” YEAR LED WARRANTY LFL LED LED Convertible Standard EV3 LFL 3” G1/G9/GS: 3-13/16” FL : 4-1/8” 3-13/16” FL & FLF: 4” 4-1/2” See back page for more details. L U M I N A I R E S P E C I F I C AT I O N Sample Catalog #: EV3CI-30HO-8’/24’-IWS/FL-120-1C-W EV3CI- ____- __/__- HOUSING COLOR/LUMENS WALL/CEILING LENGTH YEAR LED WARRANTY __/__- WALL/CEILING MOUNTING LFL LED Convertible LED EV3CI- Edge Evolution 3 Inside 90˚ Corner, Satine Lens6 27K Color Temperature Lumen Options 27- 27K, 373 lumens/ft (6.2 watts/ft) 27HO- 27K, 697 lumens/ft (13.1 watts/ft) 30K Color Temperature Lumen Options 30- 30K, 399 lumens/ft (6.2 watts/ft) 30HO- 30K, 746 lumens/ft (13.1 watts/ft) 35K Color Temperature Lumen Options 35- 35K, 408 lumens/ft (6.2 watts/ft) 35HO- 35K, 762 lumens/ft (13.1 watts/ft) 40K Color Temperature Lumen Options 40- 40K, 425 lumens/ft (6.2 watts/ft) 40HO- 40K, 795 lumens/ft (13.1 watts/ft) In-Wall Component Individual Units 2- 2’, 23” fixture 3- 3’, 35” fixture 4- 4’, 47” fixture 6- 6’, 71” fixture 8- 8’, 95” fixture Continuous Runs1 xx’- Specify nominal overall row length in 1’ increments Ceiling Component Individual Units 2- 2’, 23” fixture 3- 3’, 35” fixture 4- 4’, 47” fixture 6- 6’, 71” fixture 8- 8’, 95” fixture Continuous Runs1 xx’- Specify nominal overall row length in 1’ increments Convertible ___- __- __- VOLTAGE CIRCUITING FINISH LFL In-Wall Component IW- Standard 1/2” Flange IWS- Spackle Flange 120- 120 V Ceiling Component 277- 277 V Acoustical Grid Ceiling7 UNV- UNV3 G1- 1” Ceiling Grid (120-277) G9- 9/16” Ceiling Grid GB- 9/16” Ceiling Grid with Bevel Trim GS- Screw Slot Ceiling Grid Inaccessible Ceiling FL- Standard 1/2” Flange SF- Spackle Flange NF- Flangeless2 W- Matte White S- Metallic Silver BL- Textured Black GR- Graphite BR- Bronze CC- Custom Color 1C- Single Circuit 1D- Single Circuit Dimming4 1B- Single Circuit with Battery Pack3, 4, 5 Custom Output CL_____- Specify color temp. and lumens/ft. (i.e. CL35600) CW____- Specify color temp. and wattage/ft. (i.e. CW407.5) (Specify lumens/watts between standard offering listed above. Lumens are specified per color temp.) Continuous Rows made up of both even and odd length fixtures. Ceiling fixtures designed to fall on-grid. 2NF to be utilized for metal pan / millwork ceiling. 3UNV not available with battery pack. 4Some Edge configurations will not accommodate all electrical options. Consult factory. 5Integral battery packs with remote test switch are provided with 1B option. 6Corner available with satine lens only. 7See page 3 for grid retention bracket details. 1 Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® February 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. EDGE EVOLUTION 3 / 90º INSIDE CORNER MOUNTING DETAILS 1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot Mounting 1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: Screw Slot Grid: Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part # Flange Detail Non-Flange Spackle Flange Exposed Flange Detail: Metal Pan or Millwork: Drywall, Flangeless Look: Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part # LAYOUT Edge Evolution 3 LED 1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot Mounting Inside Corner Assembly 1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: Screw Slot Grid: Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part # Flange Detail Non-Flange Spackle Flange Edge Evolution 3 LED Exposed Flange Detail: Metal Pan or Millwork: Drywall, Flangeless Look: Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part # Corner Mounting Screw Inside Corner Assembly Wire Chase Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® February 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. GRID RETENTION BRACKET EDGE EVOLUTION 3 / 90º INSIDE CORNER Joint holes Joint for holes #8-32 for #8-32 ScrewsScrews GRID RETENTION: At every joint, the addition of grid retention brackets results in a sturdy connection between the fixtures and the grid. Insert screws through the bracket into the grid to secure. JOINT ALIGNMENT: Incorporating biscuits and screws not only creates a secure joint but also aids in fixture alignment. BiscuitBiscuit Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® February 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.