partial electrical plan partial reflected ceiling plan locker addition

MTL. TOP TRACK
BY 'CEMCO' ICC ESR-3016 & 2620
#8 SHT. MTL. SCREW
AT EA. STUD
MTL. CEIL. JOIST
+10'-0"
6"-20 GA. BOTTOM
TRACK PRESSURE
TRT'D PLATE
w/ 1" POWDER
ACTUATED PINS @24" O.C.
METAL STUDS OR
2X CEILING JOISTS @ 16" O.C
TO MATCH EXISTING
SUSP. CEIL. LINE
MTL. STUDS
BY 'CEMCO' ICC ESR-3016 & 2620
GYP. BD.
#8 SHT. MTL. SCREW
AT EA. STUD.
EXISTING
CONC. SLAB
GYP. BD.
8'-0"
@ RESTROOMS
ANTONIO SANTAMARIA DESIGN
WENDELL VEITH ARCHITECT
9'-0"
#8 SHT. MTL. SCREW
AT EA. CEIL. JOIST
R=13 INSULATION
WHERE OCCURS
+9'-0"
custom homes
5/8" WATER RESIST. GYP. BD.
(TYPE X WHERE OCCURS) ON
7/8" FURRING "HAT" CHANNELS
@ 16" O.C
MTL. WALL RUNNER w/
2-#8 SHT. MTL. SCREWS
TO EA. STUD
commercial
antonio.santamaria@live.com
TRANSVERSAL
LONGITUDINAL
41905 Boardwalk , Suite R
tel. 760.625.4563
palm desert, ca. 92211
7 LOCKERS RELOCATED
ELEVATION 3
HARD CEILING DETAIL @ TOILET ROOM
WALL TO CONCRETE SLAB
3
1
9'-0"
5
9'-0"
WALL TO CEILING METAL STUDS
6" METAL STUD WALL
TO MATCH EXISTING
GYP BOARD W.R. W/
FINISH
5/8" GYPSUM BOARD
4" CERAMIC TILE BASE
CERAMIC TILE TO MATCH
EXISTING
6"
SEALANT
Revisions :
ELEVATION 1
ELEVATION 2
SEALANT
1
18 GA. GALV.
METAL FRAME
PLANCHECK B15-001-892
LOCKER ADDITION ELEVATIONS
HOLLOW METAL DOOR
SCALE : 1/4" = 1'-0"
4
TYPICAL BASE DETAIL
DOOR JAMB/HEAD
2
Instruments of Service
THIS DOCUMENT CONTAINS INFORMATION PROPERTY OF ANTONIO
SANTAMARIA DESIGN AND IS FURNISHED IN CONFIDENCE FOR THE
LIMITED PURPOSE OF EVALUATION, BIDDING AND CONSTRUCTION. THIS
DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER
PURPOSE OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN
CONSENT OF ANTONIO SANTAMARIA DESIGN
ALL RIGHTS RESERVED
C COPYRIGHT 2015
WOMEN'S REST ROOM
WOMEN'S REST ROOM
JANITOR
VESTIBULE
JANITOR
VESTIBULE
Project :
MEN'S LOCKER ROOM EXPANSION
TELE/DATA
THE COACHELLA VALLEY
MOSQUITO & VECTOR
CONROL DISRICT
TELE/DATA
MEN'S REST ROOM
MEN'S REST ROOM
43420 Trader Place
Indio , California 92201
(E) 9'-0" HT. CLG.
S
VESTIBULE
(E) 9'-0" HT. CLG.
CORRIDOR
S
CORRIDOR
16
(E) 9'-0" HT. CLG.
MEN'S LOCKER ROOM
MEN'S LOCKER ROOM
S
(E)
(E)
MEN'S SHWRS.
3
A3
(N)
(N)
(E) 9'-0" HT. CLG.
Sheet Title :
MEN'S SHWRS.
ELECTRICAL & CEILING PLAN
(E)
(E)
(E)
S
(E)
(E)
(E)
2
1
Project No.:
ELECTRICAL SYMBOL SCHEDULE
1'X4' RECESSED OR SURFACE MOUNTED
FLUORESCENT LIGHT FIXTURE WITH 32-WATT
T8 LAMPS AND ELECTRONIC BALLAST.
SEASONAL STAFF ROOM
S
EXISTING
26-WATT ROUND RECESSED "ICAT" RATED CAN
CFL LIGHT FIXTURE WITH ELECTRONIC BALLAST
AND WHITE OR ALUMINUM REFLECTOR AND TRIM.
EXISTING FIRE ALARM
PARTIAL REFLECTED CEILING PLAN
SCALE : 1/4" = 1'-0"
EXISTING CEILING MOUNTED FIRE SPRINKLER HEAD
JULY 29, 2015
Drawn by:
A.S.
Scale:
As Shown
SEASONAL STAFF ROOM
STANDARD SWITCH
EXISTING SMOKE DETECTOR
Date:
PARTIAL ELECTRICAL PLAN
SCALE : 1/4" = 1'-0"
Sheet :