TABLE OF CONTENTS

W MG Product Features ...........................................

........

........

...................................... 3

Preparation ...................................................................................................................... 4

Figure 1 - Component Identification Pictorial .............................................................. 4

Important Installation Warnings (Things To Do Before & During Installation) ......... 5

Table 1 - Component Identification Listing .................................................................. 5

Door Types and Mounting Positions ............................................................................ 6

Installation Instructions ................................................................................................. 7

Figures 5-9, Installation Pictorials................................................................................. 8

Setting The Limits......................................................................................................... 10

Figure 14 - Operator Exploded View ........................................................................... 11

Operator Parts List ....................................................................................................... 12

Figure 15 - Operator Dimensions ................................................................................ 14

Electrical Wiring Instructions ...................................................................................... 15

Figure 16 - Pneumatic Door Edge Installation ........................................................... 16

Figure 17 - Field Wiring ................................................................................................ 16

Operation and Adjustment Instructions ................................................................ 17-19

Important Safety Instructions for Owner .................................................................... 17

Wiring Terms ................................................................................................................. 17

Testing ........................................................................................................................... 18

Maintenance ................................................................................................................. 19

Troubleshooting............................................................................................................ 20

Wiring Diagram - Single Phase (331-3) ....................................................................... 21

Wiring Diagram - Three Phase (333-3) ....................................................................... 22

Wiring Diagram - Single Phase (1331-3) ..................................................................... 23

Wiring Diagram - Three Phase (1333-3) ..................................................................... 24

Warranty ........................................................................................................................ 25

READ THESE STATEMENTS CAREFULLY AND FOLLOW THE

INSTRUCTIONS CLOSELY!

The Warning and Caution boxes throughout this manual are there to protect you and your equipment. Pay close attention to these boxes as you follow the manual.

WARNING CAUTION

Indicates a MECHANICAL hazard of INJURY OR

DEATH. Gives instructions to avoid the hazard.

Indicates a MECHANICAL hazard of DAMAGE to your operator or equipment. Gives instructions to avoid the hazard.

WARNING CAUTION

Indicates an ELECTRICAL hazard of INJURY OR

DEATH. Gives instructions to avoid the hazard.

Indicates an ELECTRICAL hazard of DAMAGE to your operator or equipment. Gives instructions to avoid the hazard.

PRODUCT FEATURES 3

The purpose of this booklet is to provide assembly, installation and operation information concerning PowerMaster

W

MG Commercial

Vehicular Garage Door Operators and related

Accessory Products.

NOTE: IT IS IMPORTANT THAT THIS INSTRUCTION

MANUAL BE READ AND UNDERSTOOD COMPLETELY

BEFORE INSTALLATION OR OPERATION IS ATTEMPTED.

IT IS INTENDED THAT THE INSTALLATION OF THIS UNIT

WILL BE DONE ONLY BY PERSONS TRAINED AND

QUALIFIED IN THE INSTALLATION, ADJUSTMENT AND

SERVICE OF COMMERCIAL OVERHEAD DOORS AND

DOOR OPERATORS AND BY QUALIFIED ELECTRICIANS.

NOTE : THE IMPORTANT SAFEGUARDS AND

INSTRUCTIONS IN THIS MANUAL CANNOT COVER ALL

POSSIBLE CONDITIONS AND SITUATIONS WHICH MAY

OCCUR DURING ITS USE. IT MUST BE UNDERSTOOD

THAT COMMON SENSE AND CAUTION MUST BE

EXERCISED BY THE PERSON(S) INSTALLING,

MAINTAINING AND OPERATING THE EQUIPMENT

DESCRIBED HEREIN. DO NOT USE THIS EQUIPMENT FOR

ANY OTHER APPLICATION THAN ITS INTENDED

PURPOSE - OPERATING OVERHEAD COMMERCIAL

VEHICULAR GARAGE DOORS.

STANDARD FEATURES :

Limit Switches:

Rotary limit switches, easily adjusted over a wide range. The motor may be removed without affecting the limit switch adjustments.

MODEL W MG OPERATOR APPLICATIONS:

W

MG operators are intended for commercial and industrial use to raise or lower rolling steel or sectional overhead doors by chain coupling to the door shaft.

W

MG operators are suitable where all or part of the door remains in a vertical position when fully open such as doors with at least 18 inches of lift clearance or full vertical lift doors.

W

MG operators may also be used with roll up service doors and grills when specified on order from factory.

An

DOOR IN ITS CLOSED POSITION.

However, because the cross-header shaft is

-

-

W

MG operator

DOES NOT LOCK THE

Doors with a maximum area of 840 square feet (3 z HP) - maximum area slightly higher for lighter doors - consult factory prevented by the operator from turning, the torsion springs provide no assistance in lifting the door should an attempt be made to raise it manually.

W

MG operators are used in the following applications:

- Continuous Duty, Medium and Heavy

Duty Cycle Commercial installations.

Indoor Use Only

Manual Release:

Permits manual operation of the door in the event of a power failure. The

Model MG is equipped with a chain hoist to aid in manual operation and its use will not affect limit settings.

Control Circuit:

24 Volts AC. Standard three button open, close and stop supplied. Will accept all standard control devices.

-

-

5 HP available on Special Order

Use with foam/pneumatic reversing door edge or photoelectric device - REQUIRED where the 3-button station is out of sight of the door, or any other automatic, remote or manual control is used to activate the door.

Connections For Auxiliary Entrapment

Protection Devices:

Use with foam or pneumatic reversing door edge components or a photoelectric beam (across the opening) device.

Momentary Contact To Close: be activated by simply moving a wire on the terminal strip.

Feature can

OPTIONAL FEATURES:

Digital Radio Controls: Open, Close and

Stop operation. Radio units are available to control up to 27 doors from one transmitter

Digital Timer to Close:

Adjustable from 0 to

17 minutes in one second intervals.

Constant Contact To Close: operation.

Standard

Keyless Entry System: Connection terminals provided for hard wired keyless entry system. Optional radio receiver will allow operation of a wireless keyless system.

4 PREPARATION

WARNING

intended application and that the voltage and phase are in accordance with electrical power

ELECTRIC DOOR OPENERS ARE DESIGNED FOR

DOORS IN GOOD WORKING CONDITION, provided at the job site.

PROPERLY COUNTERBALANCED AND PROPERLY

WARNING

ADJUSTED IN ACCORDANCE WITH THE DOOR

MANUFACTURER'S INSTALLATION INSTRUCTIONS.

Warning: ROPE OFF THE AREA TO KEEP

PERSONNEL AND VEHICLESCLEAR OF

Before starting the installation of the operator, the door must be in good working condition and properly

VICINITY OF THE OPERATOR DURING THE

INSTALLATION. counterbalanced. Inspect the door and door guides for loose or missing hardware. Test the door manually for balance and ease of operation. Lubricate door hinges and

Stops should be installed at the top end of each track to prevent the possibility of rollers. If necessary, employ a qualified technician to adjust the springs for proper counterbalance of the door.

If the cross header shaft is made from hollow tubing rather than solid rod, it is

Stops should be installed at the top end of each track to prevent the possibility of the door rollers moving beyond the ends of the track.

If the cross header shaft is made from hollow tubing rather than solid rod, it is recommended that it be plugged with a short length of solid bar for a more secure installation of the shaft sprocket or flange coupler.

THE DOOR AND FLOOR SPACE IN THE

INSTALLER.

WARNING

SPRINGS ARE SUBJECT TO VERY HIGH FORCES AT

ALL TIMES AND ADJUSTMENTS MUST BE MADE

ONLY BY A QUALIFIED PROFESSIONAL DOOR

WARNING

Before removing the operator powerhead from the shipping carton, inspect the nameplate on the cover of the operator control box to verify that it is the correct model for the

REMOVE OR DISABLE ANY LOCKING

DEVICES FROM DOOR AND REMOVE ALL

ROPES.

FIGURE 1 - COMPONENT IDENTIFICATION

IMPORTANT INSTALLATION NOTES

WARNING

5

TO REDUCE THE RISK OF SEVERE INJURY

OR DEATH: READ AND FOLLOW ALL

INSTALLATION INSTRUCTIONS!

• Install only on a properly balanced garage door. An improperly balanced door could

cause severe injury. Have a qualified

service person make repairs to cables,

spring assemblies and other hardware before installing the opener. type is STRONGLY ADVISED FOR ALL commercial operator installations.

- An auxiliary entrapment protection device is

REQUIRED

when the three button control station is out of sight of the door or any other automatic or manual control is used.

• Remove all ropes and remove or make

inoperative all locks (unless mechanically and/or electrically interlocked to the power unit) that are connected to the garage door before installing the opener.

• Install the opener at least 8 feet or more above the floor.

• Do not connect the opener to the source of power until instructed to do so.

• Lightweight doors (fiberglass, aluminum etc.) must be reinforced to avoid door damage.

Check the door manufacturer’s instruction

manual for a bracing procedure or the availability of a Reinforcement Kit.

• Locate the control station: a) within sight of the door and; b) at a minimum height of five feet above the floor and;

- The MG Series Operator is a Commercial

Vehicular Door Operator and as such is NOT recommended for pedestrian traffic. In installations where it is known that pedestrians will be nearby ensure a pedestrian door is available for entrance and exit to the building.

In addition

YOU MUST install an auxiliary entrapment protection device (reversing door edge or photoelectric beam device) as part of the complete operator system

.

- Connect an auxiliary entrapment protection device (reversing edge or photoelectric device across the door opening).

A device of this c) away from all moving parts of the door.

• Do not overtighten the clutch adjustment

(when provided) to compensate for a poorly working door.

• Securely attach any WARNING signs or placards to either the door or above the control station as directed (see page 15).

• After installing the opener, all control

features must be tested for proper operation (see page 18).

TABLE 1 - COMPONENT IDENTIFICATION LISTING

Item # Description

1 Operator Power Head

2 Driven Sprocket on Door Shaft

3 Set Screw, 5/16-18 x 1, Square

Head

4 Steel Square Key

6 Drive Chain

7 Master Link

8 3 Button Station

1

1

1

1

Qty. Item #

1

Description

10 Sash Chain, Precut

1

2

11 Chain lock Bracket

13 Hand Chain, Precut

14 Mounting Bracket

15 Wall Mounting Plate w/Studs

16 Drive Sprocket

17 Set Screw, 5/16-18 x 5/16 socket head set screw

18 Key, 1/4 x 1/4 x 1

Qty.

1

1

1

Optional

Optional

1

2

1

6 DOOR TYPES & MOUNTING POSITIONS

1 6

2 7

3

Figure 2

#1 Vertical Front of Coil, Right Hand

#2 Horizontal Top Of Coil, Right Hand

#3 Vertical Wall Mount, Right Hand

#4 Horizontal Side of Coil, Right Hand

#5 Horizontal Front of Coil, Right Hand

#6 Vertical Front of Coil, Left Hand

#7 Horizontal Top Of Coil, Left Hand

#8 Vertical Wall Mount, Left Hand

#9 Horizontal Side of Coil, Left Hand

#10 Horizontal Front of Coil, Left Hand

5

4

Figure 3

9

10

INSTALLATION INSTRUCTIONS 7

WARNING

SPRINGS, PULLEYS, CABLES AND MOUNTING HARDWARE USED TO

BALANCE YOUR GARAGE DOOR ARE UNDER EXTREME TENSION AT ALL

TIMES AND CAN CAUSE SEVERE INJURY OR DEATH IF DISTURBED.

DO NOT ATTEMPT ADJUSTMENT.

MOUNTING THE OPERATOR: WHEN PREPARING THE

MOUNTING SURFACE ENSURE THE OPERATOR WILL BE

RIGID AND SECURE WHEN INSTALLED, THE MOUNTING

SURFACE WILL PROVIDE A LEVEL BASE, AND THE

OPERATOR’S DRIVE SHAFT WILL BE PARALLEL WITH

THE DOOR SHAFT. FAILURE TO MEET THESE

CONDITIONS WILL RESULT IN AN OVERALL UNSAFE

DOOR OPERATION AND PREMATURE FAILURE OF THE

DOOR AND DOOR OPERATOR.

1. Figures 2 and 3, page 6 illustrates several positions suitable for mounting the operator; right hand or left hand wall mount or horizontal (shelf) mount to the torsion shaft.

For sectional doors, the MG operator must be wall mounted. For rolling steel doors the operator may be wall mounted or hood mounted by using an optional hood mounting bracket, [14]. A wall mounting plate [15] is also available from the factory (see Figure 1 ). The mounting plate/bracket provides for chain tension adjustment as well as aiding installation.

NOTE: THE OPERATOR DRIVE SPROCKET MAY

BE INSTALLED ON EITHER SIDE OF THE GEAR

REDUCER. SELECTION DEPENDS ON WHICH SIDE

OF THE DOOR THE OPERATOR IS MOUNTED ON.

punch.

4. With the chain tight and straight and the operator’s output shaft parallel with the door’s torsion shaft, trace the mounting slots (holes) on the mounting surface then lower the operator to the floor. The MG operator gear box mounting hole pattern is shown in Figure 4 .

5. The operator should be installed using 3/8” bolts through the wall. If the building’s construction will not allow the usage of through bolts then use lag bolts and shields (or the equivalent type fasteners). Mount the operator, slipping the drive chain on before bolting the operator to the mounting surface but do not completely tighten the bolts at this time.

6. Re-align the door shaft and operator drive shaft sprockets and connecting drive chain. Secure the sprockets in place with their set screws. If no keyway exists in the door shaft, drill a 3/8” diameter hole through the door sprocket and door shaft with the sprocket in its aligned position. Insert a

3/8” diameter bolt (not provided) through the sprocket hub and shaft. Secure with a lock washer and hex nut. See

Figure 7 .

7. Adjust the drive chain tension such that there is no more than 1/4” slack when the chain is depressed between the sprockets. See Figure 8 . The preferred mounting is with the motor end up and the operator below the door shaft.

This results in better clearance for the hand chain and disconnect chain.

Figure 4

2. Determine which side of the door the operator will be located on. Fasten the sprockets [2] and [16] and the keys

[4,18] on the chosen side of the torsion shaft of the door and on the corresponding end of the output shaft of the operator. Tighten the set screws enough to prevent the sprockets from sliding off the shaft. If the door shaft lacks a keyway you will need to drill and pin the sprocket in accordance with Step 6 (tightening the set screws is sufficient for this step). The sprockets should be kept as close as possible to the bearings. Fasten the wall mounting plate or the mounting bracket (as applicable and if available) to the operator gear box flange. Temporarily suspend the operator in its mounting position so that the distance between the door shaft and the operator’s output shaft is between 12” and 15”. See F igure 5 for wall mount and Figure 6 for bracket plate mount illustration. The distance between the shafts may be greater if the mounting conditions prohibit installation as suggested.

3. Connect the two drive sprockets [2 and 16] with the drive chain [6] and connecting link [7], shortening the chain to the proper length if necessary. To shorten the chain use a chain break tool or drive out the appropriate rivets with a

8 INSTALLATION INSTRUCTIONS

12” to 15”

Figure 6

12” to 15”

Figure 5

Figure 8

INSTALLATION INSTRUCTIONS

CHAIN HOIST INSTALLATION

1. Refer to to install the chain hoist. Pass the hand chain, item 13 over the chain pocket wheel and through the guide holes in the chain guard.

Fasten the ends of the chain together (to make one continuous loop) by opening and re-closing one link using two pairs of pliers. If the chain is too long, shorten it to the desired length by removing links.

2. Remove the sash chain from the shipping bag and let hang from the disconnect lever. Pull the sash chain to engage the hand chain. This will actuate the interlock switch and disengage the solenoid brake.

3. Use lag screws to attach the chain lock bracket, item

11, to the wall, vertically in line with the sash chain about four feet off the floor. See Figure 11 .

BEFORE PROCEEDING WITH THE OPERATOR

INSTALLATION AND SETTINGS, MAKE A FINAL

CHECK FOR TIGHTNESS OF ALL MOUNTING

HARDWARE AND SET SCREWS.

Figure 11

107174

9

Figure 10

10

WARNING

TO AVOID RISK OF ENTRAPMENT AND POSSIBLE

DAMAGE TO THE DOOR AND OPERATOR THE LIMITS

MUST BE ADJUSTED BEFORE APPLYING POWER TO

THE OPERATOR.

SETTING THE LIMIT SWITCHES

1. Open the cover on the electrical enclosure. There are two limit nuts on the threaded shaft that move laterally along the shaft as the operator opens and closes the door. When a limit nut nears the end of the shaft it activates a (set of) switch(es).

The OPEN limit switch is on the LEFT and the CLOSE limit switch is on the RIGHT. Auxiliary switches may also be present, they are used to control other functions. These are mounted to a separate bracket and should not be confused with the the OPEN and CLOSE Limit Switches which are mounted to the back of the electrical enclosure box and are somewhat hidden from view.

2. Manually raise the door to a nearly open position.

3. Depress the limit nut retaining bracket away from the slots in the limit nuts. Turn the OPEN limit nut on the shaft until it

INSTALLATION INSTRUCTIONS

engages the Open Limit Switch, the switch will sound an audible “click” when engaged. If the Open Limit is a DPDT switch (a total of 6 (six) connecting terminals protruding from the switch body, a SPDT switch has only three (3) terminals), you will need to listen for two audible clicks. Release the retaining bracket and be sure that it engages in slots of both limit nuts.

4. Manually lower the door to a nearly closed position and repeat Step #3 with the Close limit nut and switch.

5. If auxiliary switches are present, the limit nut will actuate them just prior to activating the open or close limit switch. (This is preset at the factory.)

6. Manually move the door to a half open position to avoid door damage due to incorrect power supply phasing. On three phase units the door may initially run in the wrong direction when power is first applied.

With the door in a mid position there will be time to stop the door before damage can happen if incorrect phasing occurs.

7. A final limit adjustment will be necessary after the connection of the power supply in order to ensure the door stops at the proper Open and Close positions.

Figure 13

8 2

9 0

9 7

3 9

4 7

9 6

1 1 0

9 2

4 8

4 5

7 9

1 0 9

4 6

3 8

9 7

9 0

4 3

4 9

9 7

7 1

5 8 5 4

4 4

1 0 1

1 0 6

4 2 4 0

9 5

8 1 4 9

6 3

3 2

5 0

8 3

8 4

2 0

8 5

8 0

1 6

1 0 1

1 0 6

4 1

2 2

3 1

5 0

4 9

1 0 3

3 7

6 2

6 4

9 3

6 1

7 5

1 9

7 3

8 6

6 6

2 8

1 2

5 9

2 1

7 5

7 2

6 5

8 7

1 0 2

8 5

2 5

7 5

2 4

9 1

5 5

9 9

8 5

1 5

1 0 4

9 8

2 9

8 5

8 5

1 7

3 0

7 3

1 1

7 5

2 7

9 9

5 5 6 1

7 4

5 1

9 7

6 9

4 4

4 3

1 0 8

1 0 5

1 0 7 1 0 2

9 9

9 7

1 1 1

1 0 7

8 8

1 0 0

2 9

9 1

7 5

7 6

1 4

6 2

9 9

5 3

7 8

3 4

7 8

8 8

1 0 8

3 6

6 7

7 8 6 8

2 3

7 0

2 6

6 1

1 3

5 6

5 7

6 0

6 1

6 2

1 0

3 3 5 8

7 7

7 7 3 5

7 0

8 9

O P E R A T O R M O D E L

" W M O "

5 6 0 3 - A

W M O

P o w e r M a s t e r

I T E M Q T Y .

D E S C R I P T I O N P A R T S #

1 O n e N E M A 4 o r N E M A 1 2 e n c l o s u r e

2 O n e E l e c t r i c a l p l a t e

3 T w o W M O e l e c t r i c b o x m o u n t i n g b r a c k e t

4 O n e B e a r i n g b r a c k e t

A S R E Q ' D .

6 8 0 4

6 8 0 2

6 8 0 3

5 O n e L i m i t n u t r e t a i n i n g p l a t e

6 O n e P a d d l e

6 2 0 9

6 7 0 8

7 O n e E m e r g e n c y m a c h i n e r y b o x ( c h a s s i s b o x ) 6 4 0 5

8 O n e E m e r g e n c y m a c h i n e r y b o x c o v e r

9 O n e G e a r e n g a g e m e n t p l a t e ( h o r s e s h o e )

1 0 O n e C h a i n l o c k b r a c k e t

1 1 O n e S o l e n o i d l i n k a g e

1 2 O n e B r a k e w i r e l i n k

1 3 O n e C h a i n g u a r d

1 4 O n e D i s c o n n e c t l e v e r

1 5 O n e S p r e a d e r b r a c k e t

1 6 O n e U n i v e r s a l b r a c k e t

1 7 O n e I n t e r l o c k s t o p b r a c k e t

1 8

1 9 O n e S e c o n d a r y s h a f t

2 0 O n e S t a n d a r d l i m i t s h a f t

2 1 O n e D i s c o n n e c t , s q u a r e s h a f t

2 2 O n e 3 / 1 6 " S q u a r e k e y

2 3 O n e 1 / 4 " S q u a r e k e y

2 4 O n e B r a k e s h o e

6 4 0 7

6 4 0 8

6 4 0 9

6 4 1 0

6 4 1 1

6 4 2 1

6 4 5 0

6 4 1 2

2 3 3 7

6 7 0 9

2 5 O n e B r a k e w h e e l

2 6 O n e P o c k e t C h a i n w h e e l

2 7 O n e M i t e r g e a r w i t h o u t b u s h i n g

2 8 O n e M i t e r g e a r w i t h b e a r i n g

2 9 T w o D i s c o n n e c t s h a f t s p a c e r

3 0 O n e B r a k e s h o e s p a c e r

3 1 T w o 1 / 2 " L i m i t s w i t c h s p a c e r

3 2 T w o 1 / 4 " L i m i t s w i t c h s p a c e r

3 3 O n e L i m i t s h a f t f i t t i n g

3 4 O n e L i m i t d r i v e s p r o c k e t

3 5 O n e L i m i t d r i v e n s p r o c k e t

3 6 O n e D r i v e s p r o c k e t

3 7 O n e M o t o r

3 8 O n e C o n t a c t o r

3 9 O n e 1 Ø T r a n s f o r m e r

o r 3 Ø T r a n s f o r m e r

6 4 2 3

6 4 2 7

6 4 3 3

S K 3 1 6 x 1 3 7 5

S K 1 4 x 1 2 5 0

6 4 4 7

6 4 4 8

6 4 1 7

6 4 2 9

6 4 3 1

6 0 9 9 8

6 0 8 1 1

6 0 2 2 3

6 0 1 9 5

A 1 0 5 - 6 - 8

7 3 3 9

1 0 3 6

7 3 1 4

A S R E Q ' D .

L C 2 D 0 9 1 0

T U 1 - 2 4 4 0 V A

T U 3 - 2 4 4 0 V A

L I S T

P R I C E

5 8 0 3 - 1 - B

W M O

P o w e r M a s t e r

I T E M Q T Y .

4 0 O n e L i m i t s w i t c h

4 1 O n e D o u b l e l i m i t s w i t c h

4 2 O n e B 1 l i m i t s w i t c h

4 3 O n e I n t e r l o c k s w i t c h

D E S C R I P T I O N P A R T S #

o r 3 Ø o v e r l o a d r e s e t s w i t c h ( a s r e q u i r e d ) L R 2 - A S R E Q ' D

4 5 O n e 2 4 V A C R e l a y

4 6 O n e 1 2 0 V A C R e l a y f o r 1 Ø 1 1 0 V

L S - A T - 4

L S - D A T

L S - A T - B 1

I S - A J

M B - A S R E Q " D .

R 2 4 A - S E D P D T

R 1 2 0 A - I R D P D T

o r 2 4 0 V A C R e l a y f o r 1 Ø 2 2 0 V R 2 4 0 A - I R D P D T

o r 2 4 V A C R e l a y f o r 3 Ø ( a s r e q u i r e d ) R 2 4 A - S E D P D T

4 7 O n e 1 4 P o s i t i o n t e r m i n a l s t r i p

4 8 O n e 3 p o s i t i o n t e r m i n a l b l o c k

T B - 1 1 4

T B - 0 3

4 9 T w o 1 / 2 " S t r a i g h t l i q u i d - t i g h t c o n n e c t o r 4 3 0 - L T 2

5 0 A s R e q . 1 / 2 " l i q u i d - t i g h t c o n d u i t

5 1 O n e B r a k e s o l e n o i d 1 2 0 V

1 / 2 - E F / L T

4 x 2 4 0

o r B r a k e s o l e n o i d 2 4 0 V ( a s r e q u i r e d ) 4 x 8 9 4

5 2

5 3 O n e G e a r r e d u c e r ( u p t o 1 H P ) V E - 5 5

o r g e a r r e d u c e r ( 1 1 / 2 - 2 H P ) a s r e q u i r e d V E - 7 0

5 4 O n e 3 / 8 " F l a n g e b e a r i n g

5 5 T w o 3 / 4 " F l a n g e b e a r i n g

5 6 O n e 1 " F l a n g e b e a r i n g

5 7 O n e 3 / 4 " B e a r i n g

5 8 T w o 3 / 8 " S h i m

5 9 O n e 5 / 8 " S h i m

6 0 O n e 3 / 4 " S h i m ( t h i n )

6 1 T e n 3 / 4 " S h i m ( t h i c k )

6 2 T h r e e 3 / 4 " E - R i n g

6 3 T w o L i m i t n u t g u i d e p r e s s u r e s p r i n g

6 4 O n e M i t e r g e a r r e t u r n s p r i n g

6 5 O n e H o r s e s h o e r e t u r n s p r i n g

6 6 O n e B r a k e s h o e r e t u r n s p r i n g

6 7 O n e L i m i t c h a i n ( f o r 5 5 r e d u c e r )

o r l i m i t c h a i n ( f o r 7 0 r e d u c e r )

6 8 O n e D r i v e c h a i n

6 9 O n e E m e r g e n c y h a n d c h a i n

7 0 O n e D i s c o n n e c t c h a i n

7 1 O n e R o l l p i n

7 2 O n e R o l l p i n

7 3 T w o R o l l p i n

F B - 3 7 5

9 4 0 3

F B - 1 0 0 0

P B - 7 5 0

3 7 5 - 0 5 0

6 2 5 x 0 5 0

7 5 0 x 0 1 6

7 5 0 x 0 5 0

S E - 7 4 - S T P A

0 4 5 D 3 M W

L C 0 6 7 K 4 M W

L E 0 4 9 C 0 9 M W

L E 0 6 3 E 3 M W

R C 6 5 x 4 9

R C 6 5 x 5 1

R C 5 0 x 8 7

L L - 4 0

8 A - 1 2

R 1 2 5 x . 6 2 5

R 1 8 7 x 2 . 5

R 3 1 2 x 1 . 6 2 5

L I S T

P R I C E

5 8 0 3 - 2 - A

I T E M Q T Y .

W M O

D E S C R I P T I O N

P o w e r M a s t e r

P A R T S #

L I S T

P R I C E

9 8 T h r e e S e r r a t e d f l a n g e h e x n u t

9 9 S e v e n S e r r a t e d f l a n g e h e x n u t

1 0 0 O n e S e r r a t e d f l a n g e h e x n u t

1 0 1 F o u r H e x n u t

1 0 2 T w o H e x n u t

1 0 3 T w o L i m i t n u t

1 0 4 O n e F l a t w a s h e r

1 0 5 F o u r F l a t w a s h e r

1 0 6 f o u r L o c k w a s h e r

1 0 7 F i v e L o c k w a s h e r

1 0 8 F o u r L o c k w a s h e r

1 0 9 T w o R i v e t

7 4 O n e R o l l p i n

7 5 F i v e C o t t e r p i n

7 6 O n e C o t t e r p i n

7 7 T w o S o c k e t s e t s c r e w

7 8 T h r e e S o c k e t s e t s c r e w

7 9 F o u r P a n h e a d m a c h i n e s c r e w

8 0 T w o P a n h e a d m a c h i n e s c r e w

8 1 T w o P a n h e a d m a c h i n e s c r e w

R 3 1 2 x 2 . 5

C 1 2 5 x 1

C 1 2 5 x 1 . 5

1 4 0 4 S S C

3 1 0 5 S S C

0 6 0 6 M S P

0 6 2 4 M S P

0 8 0 6 M S P

8 2 F o u r P a n h e a d m a c h i n e s c r e w

8 3 T w o H e x h e a d m a c h i n e s c r e w

8 4 T w o H e x h e a d m a c h i n e s c r e w

8 5 1 1 H e x h e a d t a p b o l t

1 0 0 6 M S P

0 6 1 6 M H

0 6 3 2 M H

1 4 1 0 B H T

8 6 O n e H e x h e a d t a p b o l t

8 7 O n e H e x h e a d t a p b o l t

1 4 2 6 B H T

3 1 2 8 B H T

8 8 F o u r H e x h e a d t a p b o l t 3 7 1 6 B H T

8 9 T w o H e x w a s h e r h e a d , t y p e B , s h e e t m e t a l s c r e w 0 8 0 4 B S W

9 0 F o u r H e x w a s h e r h e a d m a c h i n e s c r e w

9 1 S i x H e x w a s h e r h e a d m a c h i n e s c r e w

0 8 0 8 M S W

0 8 1 2 M S W

9 2 O n e H e x w a s h e r h e a d m a c h i n e s c r e w ( g r e e n ) 1 1 0 6 M S W

9 3 T h r e e S o c k e t h e a d s c r e w 1 1 1 4 C S P

9 4

9 5 T w o E l a s t i c s t o p n u t

9 6 F o u r S e r r a t e d f l a n g e h e x n u t

9 7 1 2 S e r r a t e d f l a n g e h e x n u t

0 6 N S

0 6 N R

0 8 N R

1 1 N R

1 4 N R

3 1 N R

0 6 N F

1 4 N F

L - 1 0 0

3 1 W S A E

3 7 W S A E

0 6 W S

1 4 W S

3 7 W S

B F 0 1 - 0 6 3 0

S D - 4 6 B S 1 1 0 T w o R i v e t

1 1 1 T w o P l a s t i c c l a m p

5 8 0 3 - 3

ELECTRICAL WIRING INSTRUCTIONS

WARNING

TO PREVENT THE RISK OF PERSONAL INJURY OR

DEATH :

• DISCONNECT POWER AT THE FUSE BOX

BEFORE PROCEEDING.

• ELECTRICAL CONNECTIONS MUST BE

MADE BY A QUALIFIED INDIVIDUAL.

• OBSERVE LOCAL ELECTRICAL CODES WHEN

WIRING THE OPERATOR.

1 5

WARNING

RISK OF ENTRAPMENT THAT MAY RESULT IN

SERIOUS PERSONAL INJURY OR DEATH.

DISCONNECT POWER TO THE OPENER BEFORE

AND DURING INSTALLATION OF AN ACCESSORY

REVERSING DOOR EDGE OR PHOTOELECTRIC

DEVICE. DO NOT RECONNECT POWER TO

OPENER UNTIL INSTRUCTED TO DO SO. ENSURE

DOORWAY IS CLEAR BEFORE STARTING TESTING

OF UNIT.

NOTE: Modelr WMG operators have been designed and constructed for use with voltages from 115 Volts AC to 480

Volts AC, in single or three phase. Check the operator nameplate label on the control box cover for the proper voltage and phase. The application of an improper input voltage or phase will result in catastrophic failure to the internal electrical components. Observe local electrical codes when wiring the operator.

When hard wiring, observe state and local electrical codes. A wiring diagram is attached to the inside of the control box cover. Connect the appropriate voltage and phase power leads to the appropriate terminals as per the wiring diagram and connect a ground wire to the grounding screw. On three phase units, incorrect phasing of the power supply will cause the motor to rotate in the wrong direction (open when CLOSE button is pushed and vice versa). To correct this, interchange any two of the incoming three phase conductors.

The wiring diagram attached inside the cover of the control box details all of the field wiring terminal connections for the operator. Always connect the wires to the push-button controls and auxiliary devices exactly as shown.

Warning: Control voltage of the operator is 24 volts AC,

Class 2. Do not run the power leads and control circuit wiring in the same electrical conduit.

WARNING

TO PREVENT THE RISK OF PERSONAL INJURY AND/

OR DAMAGE TO DOOR OR PROPERTY, ONLY

OPERATE DOOR CONTROL WHEN DOOR IS IN

CLEAR VIEW. IF CONTROL STATION CANNOT BE

LOCATED WHERE THE DOOR IS VISIBLE OR IF ANY

OTHER DEVICE IS USED TO CONTROL THE DOOR

AN AUXILIARY ENTRAPMENT DEVICE (DOOR EDGE

OR PHOTOELECTRIC) MUST BE CONNECTED .

Note:

Most WMG operators are pre-wired to accept reversing edge components. To comply with UL requirements, one of these systems must be installed and wired to the operator. Refer to Figures 16 and 17 for Edge component wiring and installation.

For operator models not installed with reversing edge components or photoelectric device, ONLY ONE THREE

BUTTON STATION OR A CONTROL WIRED FOR

CONSTANT PRESSURE TO CLOSE MAY BE USED TO

CONTROL THE OPERATOR. THIS IS TO COMPLY WITH

UL SAFETY REQUIREMENTS. IN THIS CASE THE

CONTROL STATION MUST BE LOCATED WITHIN

CLEAR SIGHT OF THE DOOR ADJACENT TO A

PLACARD (SUPPLIED WITH THE OPERATOR) WITH

THIS WORDING:

WARNING TO PREVENT ENTRAPMENT

DO NOT START DOOR DOWNWARD

UNLESS DOOR WAY IS CLEAR

Operators which are equipped with a reversing edge circuit may have one or more additional means of control which should be wired in accordance with the diagram supplied in the operator. Refer to Figure 17.

Number 18 gauge wire or heavier must be used for wiring the control stations and auxiliary control devices to the operator. Smaller gauge wire will cause operational problems, especially when multiple pushbutton stations are used or during summer months.

CAUTION

TO AVOID DAMAGE TO DOOR AND OPERATOR

ENSURE ALL DOOR LOCKS ARE DISABLED.

USE AN INTERLOCK SWITCH IF A LOCK IS

REQUIRED TO RETAIN FUNCTIONALTY.

16 PNEUMATIC DOOR EDGE INSTALLATION - FIELD WIRING

Figure 16

5 4

OR

3

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1

BR

ST

OP CL

PHOTOCELL

OR 3-WIRE

AIRSWITCH

V

2

SINGLE

CONTACT

CONTROL

EXT'L INTL'K

(WHEN REQ'D)

TIMER DEFEAT

SWITCH (N.C.)

(WHEN REQ'D)

NOTES:

2-WIRE EDGE

OR AIRSWITCH

(SEE NOTE #3)

OBSTRUCTION

SENSING DEVICE

1 - INSTALL BROWN JUMPER WIRE IF THERE IS NO STOP BUTTON OR EXTERNAL

INTERLOCK SWITCH CONNECTED TO TERMINAL STRIP.

2 - REMOVE VIOLET JUMPER WIRE WHEN TIMER DEFEAT

SWITCH IS USED.

3 - INTERNAL ORANGE JUMPER.

-MOVE THIS JUMPER FROM TERMINAL #7 TO #8 IF ALL OBSTRUCTIONS

SENSORS ARE 2-WIRE TYPE.

-REMOVE JUMPER IF 3-WIRE DEVICES ARE USED.

4 -TREADLES, PULL SWITCHES, KEY SWITCHES, PHOTO-ELECTRIC DEVICES,

ETC. MAY BE CONNECTED TO TERMINALS INDICATED.

5 -REMOTE CONTROL UNITS (EXCLUDING TREADLES AND PHOTO-ELECTRIC UNITS).

PULL SWITCHES AND SINGLE CONTACT CONTROL STATIONS MAY BE CONNECTED

TO TERMINALS INDICATED.

FIG U R E 17

GND

L1 L2 L3

INCOMING LINE

R3 R2 R1

RADIO

RCVR

OPERATION AND ADJUSTMENT INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS FOR OWNER

17

WARNING

TO REDUCE THE RISK OF SEVERE INJURY OR

DEATH: READ AND FOLLOW ALL INSTRUCTIONS!

NEVER let children operate or play with door controls. Keep the Remote Control away from children.

ALWAYS keep a moving door in sight and keep people and objects away from the door area until the door is completely closed. NO ONE SHOULD CROSS THE PATH OF A MOVING

DOOR.

• TEST THE DOOR OPENER’S REVERSING FEATURE (where applicable) MONTHLY. The door

MUST reverse upon contact with a 4” high object on the floor.

• After adjusting the force setting, if equipped with a clutch, or the limit of travel, ALWAYS RETEST the Opener.

Failure to ADJUST THE OPENER PROPERLY may result in SERIOUS INJURY

OR DEATH.

DO NOT over adjust the force setting (clutch, where applicable) to compensate for a poorly working door. See page 19 for procedure to check the door operation and insert sheet for proper clutch adjustment.

KEEP THE GARAGE DOOR PROPERLY BALANCED. (See the door owner's manual.)

AN IMPROPERLY BALANCED DOOR MAY CAUSE SEVERE INJURY OR DEATH.

Have a QUALIFIED SERVICE PERSON MAKE REPAIRS TO CABLES, SPRING ASSEMBLIES

AND OTHER HARDWARE.

SAVE THIS INSTRUCTION MANUAL AND GIVE TO THE END USER.

NOTE: It is now necessary to turn on the power in order to run the Opener to check for proper operation and limit settings.

Before doing so, ensure that all mounting hardware are installed and properly tightened, that all electrical connections are per local code requirements, and that proper wiring practices have been followed.

Also, double-check that all ropes have been removed from the door and that the doorway is clear.

WIRING TERMS

WARNING

FAILURE TO TEST REVERSING SYSTEM COULD

RESULT IN DEATH OR SERIOUS INJURY. TEST

THIS SYSTEM ONCE A MONTH.

WARNING

AVOID ELECTROCUTION:

DO NOT ROUTE LOW VOLTAGE WIRES IN

SAME CONDUIT AS HIGH VOLTAGE WIRES.

FOLLOW ALL LOCAL ELECTRICAL CODES or

THE NATIONAL ELECTRICAL CODE (NEC).

MOMENTARY CONTACT:

Button can be pushed and then released and door will keep moving or stop without maintaining pressure on the button.

CONSTANT PRESSURE:

Constant pressure is required on the button in order for continued door movement. When the button is released the door will stop and possibly reverse to full open depending on wiring type.

DOOR EDGE/PHOTOELECTRIC INPUT:

The operator wiring provides for input from an optional pneumatic or electric door bottom edge or photoelectric device that will cause a closing door to stop and may reverse it to open depending on the wiring type.

18 OPERATION AND ADJUSTMENT INSTRUCTIONS

TESTING

WARNING

MG operators are equipped with a reversing edge circuit for use with pneumatic edge or foam edge door components.

ALWAYS DISCONNECT POWER TO THE

O P E R A T O R B E F O R E S E R V I C I N G ,

CONNECTING ACCESSORY DEVICES OR

MAKING ADJUSTMENTS.

WARNING

Following installation, the operator MUST be tested and respond correctly to all controls as specified on the wiring diagram. KEEP personnel and equipment clear of the area beneath the door when performing the tests. When testing the 3-button wall station, first observe that each button operates the door in the direction indicated and that the

STOP button performs that function. With the door stopped at its full open position, the OPEN button should be inoperative. This should be verified and, likewise, the CLOSE button should be inoperative with the door fully closed.

Certain operator control circuits use only a single button or a two button control station and may be designed to function differently than the more common three-button circuit described above. Test the controls in accordance with the proper response for your installation.

Observe the door when traveling in each direction for smoothness of operation. Test the setting of the clutch (if equipped) by restraining the door by hand. The clutch should slip. Re-check the limit settings. The door should close tightly at the floor without excessive impact. Likewise, it should fully clear the door opening without the carrier striking the stops on the rail.

DO NOT STAND UNDER DOOR TO TEST

REVERSING EDGE. USE A CORRUGATED

BOX OR SIMILAR OBJECT.

To test it for proper reversal, place an object beneath the leading edge of the door. The door should instantly reverse when it comes into contact with the object provided the height of the object exceeds the cut out point built into the close limit switch (approximately four inches).

If the operator is equipped with other means of control, such as additional 3 button stations or radio controls, each of these should be tested separately for proper operation.

To test the manual disconnect first move the door to the fully closed position. Then disconnect the power to the operator. Manual door operation mode should engage when the release chain is pulled. The door can then be manually opened or closed by physically moving the door or using the hoist chain. If it is difficult to engage and/or the jackshaft to doorshaft chain appears to be under compression, reset the CLOSE limit slightly to reduce the door travel in the close direction.

MAINTENANCE 19

Normally, very little maintenance is required. A monthly visual inspection must be made for loose or missing hardware and for excessive slack in the jackshaft chain. The brake is adjusted at the factory and will need periodic adjustment for wear.

Test the reversing edge circuit or components (where applicable) at least once a month by permitting the door to contact an obstruction while closing.

WARNING

DO NOT STAND UNDER DOOR TO TEST

REVERSING EDGE. USE A CORRUGATED

BOX OR SIMILAR OBJECT.

Periodic inspection of gear box oil level should be made by removing oil level plug. If oil level is below this plug, add Mobil 1 Gear Oil or equivalent to bring to proper level.

Lubrication of the operator is not required. It is important, for trouble free service from the operator, that the door be kept free from binding, properly counter balanced and periodically lubricated. An annual inspection of the door by a qualified overhead door professional is recommended.

* Door must be in good operating condition. An electrical door operator cannot move a garage door that is in poor condition. The door must operate freely in the track, with no binding or obstructions, and must be well balanced. Check the spring balance of your door by bringing the door to a half-open position and leaving it there. If the door stays in that position, it is well balanced. If it moves more than a few inches the springs possibly need adjustment. Call a qualified door service company.

Warning: Repairs and adjustments to the door and operator should be performed only by someone qualified to service commercial overhead doors and operators.

20

OPERATION AND ADJUSTMENT INSTRUCTIONS

SYMPTOM POSSIBLE CAUSE SOLUTION

Motor runs but door does not move

Door jammed or obstructed. Check manual operation of door.

Sprocket key missiing or

Limit switches do not hold setting

Drive chain too loose; permits chain to jump teeth

Limit nuts binding on screw, causing them to jump

Check drive chain for operation.

Adjust chain to proper tension. See Figure 7.

Check for free rotation on limit screw. Lubricate screw or replace nuts if threads are defective.

Limit nut retaining bracket not engaging notches in nuts.

Set nuts and be sure bracket is in notch on each nut. (See

Figure 13.

Door drifts when operator shuts off.

Inoperative or improperly adjusted brake.

Door tension incorrect.

Motor hums — does not run.

Dead phase (on 3 phase).

Adjust brake. See Figure 18.

Disconnect operator and check operation of door.

Check power supply.

Brake does not release.

*Door locked or jammed.

Check wires to brake solenoid, check adjustment.

Check door. Try manual operation.

Motor does not run when open or close wall button is pressed.

Building fuse blown or circuit breaker tripped.

Check power supply fuses, circuit breakers, disconnect switch, check for cause.

Overload protector tripped. Reset and check for cause.

NOTE: To isolate cause, operate contactor solenoid plunger manually. If motor runs, cause is in push button circuit.

Check pushbutton circuits for voltage against voltage indicated on wiring diagram. Check push button wiring.

Check interlock switch wiring.

Interlock switch broken or inoperative.

Check that brake release pin is making contact with interlock switch located inside chassis box. Check wiring to switch and switch function.

Normally closed for operation electrically and normally open for hand chain operation.

Operator closes door when “open” button is pressed, and limit switches do not function properly.

Operator fails to shut off at fully open closed position.

On three phase operators power supply is connected out of phase.

Interchange connections of any two power supply leads.

(See wiring diagram)

Operator not installed correctly.

Remount operator so that motor is “up” or toward door wall or contact factory as to wiring changes required.

On three phase operators power supply is connected out of phase.

Check phase as above.

Limit nuts not adjusted

Defective limit switch.

See limit adjustments page 10.

Operator limit switfch manually while door is moving to determine if switch is operative.

Single phase operator (without instant reverse motor). Stuck push button or short in control wiring.

Limit drive chain broken or inoperative.

If door overrides up limit, check down button and circuit. If door overrides down limit, check open button and circuit.

Replace chain, check limit screw for rotating.

WIRING DIAGRAM - SINGLE PHASE 331-3

SE

21

L3

L1

TO

MOTOR

V

BL

GY

Y

OR

2

C S.E.L

NO

NC

6

7

BL

Y

WH

3

C O-L/S

NC

NO

GY

WH

WH

BL

3

24 VAC

COIL

Y/W

6

BK

SER

8

BL

7

2

OR/BL

Y/W

OR

BL

BL

LINE

VOLTAGE

COIL

TO MOTOR

(208V/

230V ONLY)

IR

6

Y

Y

A2

OR

5

14

V

13

Y

Y

4

BK

2

BL

A2

R

10

BK

14 6

BK BK

4 2

OPEN

BK

BK

BK

BK

BK

BK

5 3 1

CLOSE

13 5 3

A1

(115V

ONLY)

BL BL

1

A1

BL GY Y

(115V ONLY)

BK

BRAKE

(WHEN

REQ'D)

Y/W

SE

NO

S/E OFF C

NC

9

Y

BL

SE

NC

NO

C-L/S C

3

W

BK

WH

24VAC

3

BR

4

C

HOIST CHAIN INTERLOCK

(WHEN REQ'D)

(BREAKS CIRCUIT WHEN

ACTIVATED)

BL

7 SOLID STATE

TIMER

14

BR

L3

L1

L2

L3

UL

OVERLOAD

OR/BL

WH

R

OR

OR WH

OR OR

WH WH BR

OR

OR Y Y

BL

Y/W

BL OR

BL

3

OR

R BL

BK BKBK BK

R3 R2 R1 1 2 3 4 5 6 7 8 9 10 11 12 13 14

NOTES:

RADIO

RCVR B TO OPEN

B TO CLOSE

1

EXT'L INTL'K

(WHEN REQ'D)

1-WIRE-NOT FURNISHED WHEN EXTERNAL INTL'K SWITCH IS USED.

BR

ST

A

OP

A

CL

- NOT FURNISHED WHEN STOP BUTTON IS USED.

2- WIRE-NOT FURNISHED WHEN TIMER DEFEAT SWITCH IS USED.

3a- MOVE THIS JUMPER FROM #7 TO #8 IF ALL OBSTRUCTIONS SENSORS

ARE 2-WIRE TYPE.

2-WIRE EDGE

OR AIRSWITCH

(SEE NOTE #3)

3b-REMOVE JUMPER IF ANY 3-WIRE DEVICES ARE USED.

A-TREADLES,PULL SWITCHES, KEY SWITCHES, PHOTO-ELECTRIC DEVICES,

ETC. MAY BE CONNECTED TO TERMINALS INDICATED.

B-REMOTE CONTROL UNITS (EXCLUDING TREADLES AND PHOTO-ELECTRIC UNITS). PULL SWITCHES

AND SINGLE CONTACT CONTROL STATIONS, MAY BE CONNECTED TO TERMINALS INDICATED.

PHOTOCELL

OR 3-WIRE

AIRSWITCH

V

2

TIMER DEFEAT

SWITCH (N.C.)

(WHEN REQ'D)

OBSTRUCTION

SENSING DEVICE

L1 L2 L3

GND

INCOMING LINE

L2-HOT LEG

L1-NEUTRAL (115V ONLY)

WIRED FOR

V, 1 O

WIRING TYPE: SAFETY EDGE TO REVERSE

WITH OPTIONAL TIMER

MTR/CNTR: 1 O

DATE: 10-31-02

BY: F.S.

REV. 15

SPECIAL: OPTIONAL TIMER CIRCUIT IN

DASHED LINES

WIRING DIAGRAM NO. 331-3

C Copyright PowerMaster 1997

No portion of this diagram may be reproduced without the expressed written permission of the manufacturer.

BK

BK

22 WIRING DIAGRAM - THREE PHASE 333-3

SE L3

L2

L1

TO MOTOR

R

R

BL

Y

GY

BRAKE

(WHEN

REQ'D) GY A2

OR

5

14 6 4

OPEN

BK

BK

BK

2

BK

BL

A2

14

BK

R

10

6 4

CLOSE

BK

2

THERMAL

O/L RELAY

(WHEN REQ'D)

13 5

6

Y

3

GY

1

A1

13

7

BL BL

5 3 1

A1 L1 L2 L3

OR

2

C S.E.L

NO

7

NC

6

BL

Y

BL Y

Y/W

SE

NO

NC

S/E OFF C

9

Y

WH

3

C O-L/S

NC

NO

WH

GY

BL

WH

BL

3

24VAC SER

6 8 2

OR/BL

Y/W

Y/W

BR

BL

SE

NC

NO

C-L/S C

3

WH

TO

MOTOR

O/L

WH

24VAC

3

BR

BR

4

C

INTERNAL INTL'K

(WHEN REQ'D)

(BREAKS CIRCUIT WHEN

ACTIVATED)

L3

L1

OR

OR

WH

WH

BR OR

Y/W

BL

O/BL

WH OR Y Y BL

OR

R

OR

BL

BL

7

14

SOLID STATE

TIMER

OR 3

R3 R2 R1 1 2 3 4 5 6 7 8 9 10 11 12 13 14

1

BR

A

RADIO

RCVR

ST

OP

B TO OPEN

B TO CLOSE

EXT'L INTL'K

(WHEN REQ'D)

NOTES:

1-WIRE-NOT FURNISHED WHEN EXTERNAL INTL'K SWITCH IS USED.

- NOT FURNISHED WHEN STOP BUTTON IS USED.

2- WIRE-NOT FURNISHED WHEN TIMER DEFEAT SWITCH IS USED.

3a-MOVE THIS JUMPER FROM #7 TO #8 IF ALL OBSTRUCTIONS SENSORS

ARE 2-WIRE TYPE.

3b-REMOVE JUMPER IF ANT 3-WIRE DEVICES ARE USED.

A-TREADLES,PULL SWITCHES, KEY SWITCHES, PHOTO-ELECTRIC DEVICES,

ETC. MAY BE CONNECTED TO TERMINALS INDICATED.

B-REMOTE CONTROL UNITS (EXCLUDING TREADLES AND PHOTO-ELECTRIC

UNITS). PULL SWITCHES AND SINGLE CONTACT CONTROL STATIONS,

MAY BE CONNECTED TO TERMINALS INDICATED.

A

CL

2-WIRE EDGE

OR AIRSWITCH

(SEE NOTE #3)

PHOTOCELL

OR 3-WIRE

AIRSWITCH

OBSTRUCTION

SENSING DEVICE

V

2

TIMER DEFEAT

SWITCH (N.C.)

(WHEN REQ'D)

GND

BK

BK

L1 L2 L3

BK

BK

INCOMING LINE

WIRED FOR

V, 3 O

WIRING TYPE: SAFETY EDGE TO REVERSE WITH

OPTIONAL TIMER

MTR/CNTR: 3 O

DATE: 10-31-02

BY: F.S.

REV. 11

SPECIAL: OPTIONAL TIMER CIRCUIT IN

DASHED LINES

WIRING DIAGRAM NO. 333-3

C Copyright PowerMaster 1997

No portion of this diagram may be reproduced without the expressed written permission of the manufacturer.

WIRING DIAGRAM - SINGLE PHASE 1331-3

WH

TO

MOTOR

V

Y

BL

GY

OR

2

C S.E.L

NO

NC

7

6

Y

BL

3

C O-L/S

NC

NO

WH

GY

SE

A2

OR

5

14

V

Y

13

Y

4

BK

2

BL

A2

R

10

14

BK

6

BK BK

4 2

OPEN

BK

BK

BK

B K

BK

BK

5 3 1 13

CLOSE

5 3

A1

(115V

ONLY)

BL BL

1

A1

BL GY Y

(115V ONLY)

BK

BRAKE

(WHEN

REQ'D)

L3

L1

Y/W

BL

SE

SE

NC

NO

NC

C-L/S C

NO

S/E OFF C

3

9

Y

WH

23

WH

TDR 3

WH

24VAC SER

Y/W

6 8 2

OR/BL

Y/W

BL

V

WH

24VAC

3

LINE

VOLTAGE

COIL

BK

IR

TO MOTOR

(220V)

Y

R 6

V

Y

Y

OR/BL

V

R

TDM

BR

V

4

C

INTERNAL INTL'K

(WHEN REQ'D)

(BREAKS CIRCUIT

WHEN ACTIVATED)

WH

BL

7

24VDC TDR

7

BL

BL

14

WH

SE

BL

OR

WH

R

OR

OR

OR

Y

Y/W

BL

Y R BL

OR WH BR OR OR

3

R3 R2 R1 1 2 3 4 5 6 7 8 9 10 11 12 13 14

3 2 1

RADIO

RCVR

B TO OPEN

B TO CLOSE

1 BR

ST

A

OP

A

CL

PHOTOCELL

OR 3-WIRE

AIRSWITCH

V

TIMER DEFEAT

NOTES:

EXT'L INTL'K (WHEN REQ'D) SWITCH (N.C.)

(WHEN REQ'D)

1-WIRE-NOT FURNISHED WHEN EXTERNAL INTL'K SWITCH IS USED.

- NOT FURNISHED WHEN STOP BUTTON IS USED.

2-WIRE-NOT FURNISHED WHEN TIMER DEFEAT SWITCH IS USED.

3a-MOVE THIS JUMPER FROM #7 TO #8 IF ALL OBSTRUCTIONS SENSORS

2-WIRE EDGE

OR AIRSWITCH

(SEE NOTE #3)

ARE 2-WIRE TYPE.

3b-REMOVE JUMPER IF ANY 3-WIRE DEVICES ARE USED.

A-TREADLES,PULL SWITCHES, KEY SWITCHES, PHOTO-ELECTRIC DEVICES,

ETC. MAY BE CONNECTED TO TERMINALS INDICATED.

B-REMOTE CONTROL UNITS (EXCLUDING TREADLES AND PHOTO-ELECTRIC UNITS). PULL

OBSTRUCTION

SENSING DEVICE

SWITCHES AND SINGLE CONTACT CONTROL STATIONS, MAY BE CONNECTED TO TERMINALS INDICATED.

2

BR

G

L3

L1

BK BK BK BK

L1 L2 L3

INCOMING LINE

LI-NEUTRAL (115V)

L2 HOT LEG

L2

L3

UL

OVERLOAD

WIRED FOR

V,1 Ø

BK

BK

WIRING TYP: SAFETY EDGE 1 O TO REVERSE WITH

OPTIONAL TIMER

MTR/CNTR: 1 O

DATE: 10/31/02

BY: F.S.

REV. 12

SPECIAL: OPTIONAL TIMER CIRCUIT IN DASHED

LINES. DELAY ON REVERSE

WIRING DIAGRAM NO. 1331-3

C Copyright PowerMaster 1997

No portion of this diagram may be reproduced without the expressed written permission of the manufacturer.

24 WIRING DIAGRAM - THREE PHASE 1333-3

TO MOTOR

R

R

BL

Y

GY

BRAKE

(WHEN

REQ'D)

OR

2

C S.E.L

NO

NC

6

7

BL

Y

GY

WH

3

C O-L/S

NC

NO

WH

GY A2

OR

5

14 6

OPEN

4

BK

SE

2

BK

BR

BL

A2

14

BK

R

10

62 54 62 54

BK

61 53

BK

61 53

6 4

CLOSE

BK

2

13 5 3 1 13 5 3 1

A1

Y GY

V

BL BL

BL Y

A1

BL

SE

Y/W

SE

V

L3

L2

L1

THERMAL

O/L RELAY

(WHEN REQ'D)

NC

NO C-L/S

NC

NO

C

S/E OFF C

9

3

WH

Y

WH

BL

WH

BL

3

24VAC SER

6

OR

8

Y/W

Y

2

WH

6

Y/W

OR/BL

Y

TO

MOTOR

O/L

WH

24VAC

BR

3

BR

L3

L1

24VDC

TDR

OR/BL

WH

V

TDM V

R

4

C

BR

INTERNAL INTL'K

(WHEN REQ'D)

(BREAKS CIRCUIT WHEN

ACTIVATED)

7

R BL

BL

BR

OR

OR

OR WH

BR Y

OR Y Y/W BL

R

OR Y

OR

3

BL

BL

7

14

SOLID STATE

TIMER

R3 R2 R1 1 2 3 4 5 6 7 8 9 10 11 12 13 14

1

BR A

OP

RADIO

RCVR

ST

B TO OPEN

B TO CLOSE

EXT'L INTL'K

(WHEN REQ'D)

NOTES:

1-WIRE-NOT FURNISHED WHEN EXTERNAL INTL'K SWITCH IS USED.

- NOT FURNISHED WHEN STOP BUTTON IS USED.

2- WIRE-NOT FURNISHED WHEN TIMER DEFEAT SWITCH IS USED.

3a-MOVE THIS JUMPER FROM #7 TO #8 IF ALL OBSTRUCTION

SENSORS ARE 2-WIRE TYPE.

3b-REMOVE JUMPER IF ANY 3-WIRE DEVICES ARE USED.

A-TREADLES,PULL SWITCHES, KEY SWITCHES, PHOTO-ELECTRIC DEVICES,

ETC.. MAY BE CONNECTED TO TERMINALS INDICATED.

B-REMOTE CONTROL UNITS (EXCLUDING TREADLES AND PHOTO-ELECTRIC

UNITS). PULL SWITCHES AND SINGLE CONTACT CONTROL STATIONS,

MAY BE CONNECTED TO TERMINALS INDICATED.

A

CL

2-WIRE EDGE OR

AIR SWITCH

(SEE NOTE #3)

PHOTOCELL

OR 3-WIRE

AIRSWITCH

OBSTRUCTION

SENSING DEVICE

V

2

TIMER DEFEAT

SWITCH (N.C.)

(WHEN REQ'D)

GND

BK

BK

L1 L2 L3

BK

BK

INCOMING LINE

WIRED FOR

V, 3 O

WIRING TYPE: SAFETY EDGE TO REVERSE WITH

OPTIONAL TIMER

MTR/CNTR: 3 O

DATE: 10-31-02

BY: F.S.

REV. 12

SPECIAL: OPTIONAL TIMER CIRCUIT IN

DASHED LINES.

WIRING DIAGRAM 1333-3

C Copyright PowerMaster 1997

No portion of this diagram may be reproduced without the expressed written permission of the manufacturer.

PowerMaster

Limited 2 Year Warranty

PowerMaster warrants all door operators to be free of defects in materials and workmanship for a period of two (2) years from date of purchase. If any part is found to be defective during this period, new parts will be furnished free of charge. Failure of this product due to misuse, improper installation, alterations, vandalism, or lack of maintenance is not covered under this warranty, and voids any other implied warranties herein.

PowerMaster is not responsible for any labor charges incurred in connection with the installation of warranted parts.

In order to activate this warranty, the registration form on opposite page MUST be completed and returned within THIRTY

CALENDER DAYS FROM DATE OF PURCHASE VIA

CERTIFIED MAIL, fax (631-951-3934) or via email

PMTECH@optonline.net

If registration is not activated, a one year warranty will apply.

Model __________

Date Installed____________

Serial # ________________

Installer’s Information

Company Name _____________________

Company Address ___________________

Company Address ___________________

Company Address ___________________

Company Telephone # ________________

Company Contact ____________________

R&S Automation

7200 E. 92nd Avenue

Unit A

Portland, OR 97266

877-388-4001

503-771-4685

Fax 503-774-6708

John Greene Corp.

2807 Center Circle Drive

Downers Grove. IL 60515

800-374-7890

Fax 630-627-7995

Oregon

New York

Illinois

R & S Automation Inc.

15075 Wicks Blvd

San Leandro, CA 94577

800-543-6001

510-357-4110

Fax 510-483-1326

T e x a s

F lo ri d a

R & S Automation Inc.

1560 N. Missle Way

Anaheim, CA 92801

800-963-3111

714-449-1645

Fax 714-449-1679

John Greene Corp.

3024 Avenue E. East

Arlington, Tx 76011

800-925-7890

Fax 817-633-5735

John Greene Corp.

3516 E. Norvell Bryant Hwy.

Hernando, Fl 34442

800-323-3674

Fax 352-726-8999

Toll Free technical support @ 1-800-243-4476

Email to techsupport@power-master.net

Power Door Products

610 Fenimore Rd.

Mamaroneck, NY 10543

914-698-5083

Fax 914-698-6866

Call 1- 800 - 323 - 3674 to order or to find a distributor near you

Standard Two Year Warranty

Warehouses across the country w/ factory trained managers

Prompt delivery from stock

Special operators normally ship within 7 days

06-0922 W MG