g GE Industrial Systems OEM Load Center Parts Program 1 GE OEM Load Center Parts Program OEM Load Center Manual A Manual that Helps You Find Solutions The “Contractor’s Load Center” GE Industrial Systems is pleased to offer a comprehensive line of PowerMark GoldTM and PowerMark PlusTM load center interiors and components for Original Equipment Manufacturers (OEM’s). This offering has been assembled to provide OEM’s with unprecedented flexibility to meet their customers needs. In developing the PowerMark Gold load center, GE consulted with practicing electrical contractors. We incorporated many features suggested to us by contractors, features that make PowerMark Gold the finest quality, easiest-to-use residential load centers. All PowerMark Gold load centers incorporate a tinplated, solid copper bus for maximum conductivity and corrosion resistance. All load centers feature robust neutral bars that extend the full length of the bus for faster, more professional installations; plus, the neutral bars are raised, making them more accessible to speed installation. All enclosures are commercial-quality, heavy-gage steel with a protective galvanized finish for superior corrosion resistance. In addition, Robertson-style square-drive screws allow higher installation torque and prevent screwdriver slippage. GE’s OEM Load Center manual is designed to help you select and identify GE load center components quickly and accurately. Based on your amperage needs and the number of circuits required, this manual identifies the part numbers for the interior and all component parts. Envelope drawings are provided for each interior to assist you in adapting the GE interior to your own custom installation. This manual features: • Selection Guide for Residential Main Lug/ Convertible, Main Breaker and Commercial Load Centers Money-Saving THQP Circuit Breakers All PowerMark Gold load centers accommodate GE’s reliable THQL one-inch-wide circuit breaker. PowerMark Gold load centers also accommodate GE’s unique space-saving one-half-inch THQP circuit breaker. THQP circuit breakers help save you money by providing installation flexibility. THQP circuit breakers are identical in design to THQL circuit breakers and they are tested to the same UL specifications. THQP circuit breakers are most beneficial when size and cost constraints are driving factors, helping you to be more cost competitive. They help free up space to allow new circuits to be added to a crowded load center and thus may prevent the need to upgrade to a larger load center. THQP circuit breakers are available in one- and twopole designs up to 50 amps. • Circuit Breaker Selection Guide • Accessory Selection Guide • Part Number Identification for All Load Center Components • Dimensioned Envelope Drawings Dedication to Quality GE load centers are designed, manufactured, sold, and serviced with a dedication to quality unequalled in the electrical components industry. All GE products are produced in accordance with the company’s Six Sigma Quality Initiative. Six Sigma is the disciplined methodology of defining, measuring, analyzing, improving, and controlling the quality in all GE products, processes, and transactions—with the ultimate goal of virtually eliminating all defects. The Six Sigma initiative has changed the culture of GE and impacts everything we do and every product we design. US National Electrical Code Paragraph 384-15 requires branch-circuit load centers to be provided with a physical means to prevent the installation of more circuit breakers than the number for which the load center was designed, rated, and approved. GE load centers are designed to limit installation to no more than 42 total circuits per load center and thus the number of allowable THQP circuit breaker spaces may be limited. For information on which load centers accept THQP circuit breakers, reference the right-side view of each load center’s envelope drawing. In addition, each load center page also provides a chart that indicates the maximum number of breakers per load center. GE’s Six Sigma Quality Initiative is reinforced with a solid warranty program on each GE load center. All PowerMark Gold™ load centers are backed by a lifetime warranty. GE warrants that GE PowerMark Gold residential load centers will be free from defects in materials and workmanship, under normal care and proper installation, for the lifetime of the product. 2 GE OEM Load Center Parts Program Contents PowerMark Plus™ & PowerMark Gold™ Load Center Selection Guide .................................................. 4 Q Line Circuit Breakers............................................................................................................................... 7 Load Center Accessories.......................................................................................................................... 11 PowerMark Gold™ Load Center Parts..................................................................................................... 14 PowerMark Plus™ Load Center Parts...................................................................................................... 38 PowerMark Gold™ OEM Specialty Load Center Parts ........................................................................... 82 Note: Text printed in blue on this and the following three pages is linked to the corresponding page in the manual. As you move the Acrobat hand pointer over the text, it will change to a finger pointer. Click the mouse button to jump to that page. 3 GE OEM Load Center Parts Program PowerMark Plus™ & PowerMark Gold™ Load Center Selection Guide • UL Recognized Component • 60°/75° C Conductor Rating • Suitable for Use as Service Entrance Equipment When Installed in Accordance with the National Electrical Code • 22 kAIC RMS Symmetrical, Except Where Noted Single-Phase, Three-Wire, 120/240 Vac OEM Interiors used in PowerMark Gold Load Centers • Main Lug and Convertible Load Center Interiors – Factory-Installed Main Lugs (TLM units convertible to main breaker) – Copper Bus – Tin-Plated Standard (all OEM interiors with suffix U2) – OEM interiors are UL-recognized components listed under UL file E21790 Maximum Spaces Main Ampere Rating 70 100 125 150 200 225 1/2" 1" THQL 1p 2p 2 1 2 1 4 2 6 3 8 4 1p 4 — 8 12 16 THQP 2p 1 — 3 4 6 12 6 24 16 8 24 Total 1-Pole Spaces OEM Interior with Neutral Bar Cat. No. OEM Interior without Neutral Bar 4 2 8 12 16 TL270U2 — TL412U TLM612U2 TLM812U2 10 24 TLM1212U2 — 16 6 24 TLM1612U2 — 12 — — 24 24 12 12 4 30 TLM2415U2 — 16 8 32 14 32 TLM1620U2 — 20 10 40 18 40 TLM2020U2 32 16 16 6 40 TLM3220U2 — 40 20 — — 40 TLM4020U2 — 42 20 — — 42 TLM4222U2 — TLM2412U2 — 565B837G2 TL412UN TLM612U2N TLM812U2N — — Complete Load Center with Indoor Enclosure TL270SCU — TPL412C TLM612SCU TLM812SCU TLM1212CCU TM1210CCU TM1212CCU TLM1612CCU TM1612CCU TLM2412CCU TM2412CCU TLM2415CCU TM2415CCU TLM1620CCU TM1615CCU TM1620CCU TLM2020CCU TM2020CCU TLM3220CCU TM3220CCU TLM4020CCU TM4020CCU TLM4222CCU TM4222CCU Drawing Page # — — — 14 17 20 22 24 26 28 30 32 34 36 For Main Breaker, order mounting kit TQMH000. Also order THQL, THHQL, or TXQL circuit breaker separately. For Main Breaker, order THQMV main breaker (includes mounting base). For Main Breaker, order THQLRK2 retainer kit plus THQL, THHQL, or TXQL circuit breaker separately. 4 GE OEM Load Center Parts Program PowerMark Plus™ & PowerMark Gold™ Load Center Selection Guide Three-Phase, Four-Wire, 208Y/120 Vac OEM Interiors used in PowerMark Plus Load Centers • Factory-Installed Main Lug Load Center Interiors – OEM interiors are UL-recognized components listed under UL file E21790 Maximum Spaces Main Ampere Rating 100 125 150 200 225 1-pole 3 12 18 24 18 30 42 30 42 1" THQL 2-pole 1 6 8 12 8 14 20 14 20 3-pole 1 4 6 8 6 10 14 10 14 Total 1-Pole Spaces 3 12 18 24 18 30 42 30 42 Cat. No. Complete-Load Center,Indoor Drawing Page-# Enclosure OEM-Interior 565B837G1 TL12412U TL14815U TL24415U TL18420U TL30420U TL42420U TL30422U TL42422U — TL12412C TL18415C TL24415C TL18420C TL30420C TL42420C TL30422C TL42422C — 38 40 42 44 46 48 50 52 • Main Breaker–Style Load Centers – Main Lugs Not Included – OEM interiors are UL-recognized components listed under UL file E21790 Maximum-Spaces Main Ampere Rating 100 125 150 200 225 1-pole 12 18 30 24 30 42 24 30 42 42 1"-THQL 2-pole 6 8 14 12 14 20 12 14 20 20 3-pole 4 6 10 8 10 14 8 10 14 14 Total 1-Pole Spaces 12 18 30 24 30 42 24 30 42 42 Cat.-No. Complete-Load Center,-Indoor Drawing Page-# Enclosure OEM-Interior TM12410U TM18410U TM30412U TM24415U TM30415U TM42415U TM24420U TM3042OU TM42420U TM42422U TM12410C TM18410C TM30412C TM24415C TM30415C TM42415C TM24420C TM30420C TM42420C TM42422C Also UL Listed for 3-phase, 4-wire 240/120 Vac delta and 3-phase, 3-wire 240 Vac branch breakers installed. Three-pole plug-in breakers available through 100 amperes. Main Breaker, THHQL32100 included. For Main Breaker, order TQD*X2 or THQD*X2 style breaker with appropriate mounting bracket (see drawings). 5 54 56 58 61 64 67 70 73 76 79 GE OEM Load Center Parts Program PowerMark Plus™ & PowerMark Gold™ Load Center Selection Guide Single-Phase, Three-Wire, 120/240 Vac Specialty OEM interiors used by GE in PowerMark Gold Meter Socket Load Centers • All Specialty interiors are constructed without the neutral bar attached to the assembly. They are packaged with or without a separately mounted neutral bar. • OEM interiors are UL-recognized components listed under UL file E21790 Types • • • • • • Narrow Style – Breaker mounting rail on one side only (Column style). Wide Style – Breaker mounting rail on two sides. Split Bus – Two sections of bus. Used with multiple service disconnects. Feed-Thru – Feed-Thru lugs factory installed. Main Lug – Factory-installed main lugs (MLO). Main Breaker – Main breaker provisions, breaker sold separately. Maximum-Spaces Main Total 1/2"-THQP 1"-THQL Ampere 1-Pole 1p 2p 1p 2p Spaces Rating Split-Bus-/-Feed- Thru-/-Narrow-Style-(Farm-Panel) 200 4 2 8 3 8 Narrow-Style-/-MLO 200 4 2 8 3 8 Feed-Thru-/-Narrow-Style 200 8 4 16 6 16 Narrow-Style 12 6 24 10 24 125 16 8 32 14 32 200 20 10 40 18 40 Wide-Style-/-Main-Breaker 125 12 6 24 10 24 200 20 10 40 18 40 Cat.-No. OEM-Interior-with Neutral-Bar OEM-Interior without-Neutral Bar TSF420U TSF420UN TSLR420U TSLR420UN TSM820U TSM820UN Main Breaker 87 TSM1212U TSM1610U TSM2020U TSM1212UN TSM1610UN TSM2020UN Main Breaker Main Breaker Main Breaker 84 85 86 TSMR1212U TSMR2015U TSMR1212UN TSMR2015UN Main Breaker Main Breaker 88 89 For subfeed main breaker, order THQL, THHQL, or TXQL, 110 A max. for main breaker, order THQMV*WL breaker with main breaker retainer THQLRK1. For main breaker, order THQL, THHQL, or TXQL with mounting kit TQMH000. For main breaker, order THQMV main breaker (includes mounting base). Reverse-fed main breaker retainer is not available; customer supplied. 6 Main-Type Main Breaker MLO Drawing Page-# 82 83 GE OEM Load Center Parts Program Q Line Circuit Breakers Standard Circuit Breakers Breaker-Type • UL Listed (Molded-Case Circuit Breakers No. 489) THQP • Federal Government Specification Qualified (WC-375B) • 60°/75° C Conductor Rating THQL THHQL TXQL • Quick-Make, Quick-Break • Box-Type Terminals TQDL THQDL 10,000-AIC Ampere Rating Type-THQP- 1/2" Module 120/240- Vac Cat.-No. 125–200 1/0–250 22,000-AIC Type-THQL-1"-Module 240- Vac 120/240- Vac Cat.-No. Cat.-No. Single-Pole 15 THQP115 THQL1115 20 THQP120 THQL1120 25 THQP125 THQL1125 30 THQP130 THQL1130 35 THQP135 THQL1135 40 THQP140 THQL1140 45 THQP145 THQL1145 50 THQP150 THQL1150 Std. Pkg. 5 cartons of 20 5 cartons of 10 Two-Pole :-Incorporates-Internal-Common-Trip-Bar 15 THQP215 THQL2115 20 THQP220 THQL2120 25 THQP225 THQL2125 30 THQP230 THQL2130 35 THQP235 THQL2135 40 THQP240 THQL2140 45 THQP245 THQL2145 50 THQP250 THQL2150 60 — THQL2160 70 — THQL2170 80 — THQL2180 90 — THQL2190 100 — THQL21100 110 — THQL21110 125 — THQL21125 Std. Pkg. 5 cartons of 10 5 cartons of 5 125 — TQDL21125 150 — TQDL21150 175 — TQDL21175 200 — TQDL21200 Std. Pkg. — 10 cartons of 1 Three-Pole :-Incorporates-Internal-Common-Trip-Bar 15 — — 20 — — 25 — — 30 — — 35 — — 40 — — 45 — — 50 — — 60 — — 70 — — 80 — — 90 — 100 — — Std. Pkg. — — Wire-Size-AWG/ kcmil Cu Al 14–8 12–8 8–4 8–2 14–8 12–8 8–3 8–2 6–1/0 4–1/0 2–2/0 2–2/0 Ampere-Rating 15–25 30–50 15–30 35–60 70–100 110–125 1/0–250 65,000-AIC Type-TXQL-1"-Module Type-THHQL-1"-Module 240- Vac 120/240- Vac Cat.-No. Cat.-No. 120/240- Vac Cat.-No. — — — — — — — — — THHQL1115 THHQL1120 THHQL1125 THHQL1130 THHQL1135 THHQL1140 THHQL1145 THHQL1150 5 cartons of 10 — — — — — — — — — TXQL1115 TXQL1120 TXQL1125 TXQL1130 — — — — 5 cartons of 10 THQL2215 THQL2220 THQL2225 THQL2230 THQL2235 THQL2240 THQL2245 THQL2250 THQL2260 THQL2270 THQL2280 THQL2290 THQL22100 — — 5 cartons of 5 — — — — — THHQL2115 THHQL2120 THHQL2125 THHQL2130 THHQL2135 THHQL2140 THHQL2145 THHQL2150 THHQL2160 THHQL2170 THHQL2180 THHQL2190 THHQL21100 THHQL21110 THHQL21125 5 cartons of 5 THQDL21125 THQDL21150 THQDL21175 THQDL21200 10 cartons of 1 THHQL2215 THHQL2220 THHQL2225 THHQL2230 THHQL2235 THHQL2240 THHQL2245 THHQL2250 THHQL2260 THHQL2270 THHQL2280 THHQL2290 THHQL22100 — — 5 cartons of 5 — — — — — TXQL2115 TXQL2120 TXQL2125 TXQL2130 — — — — — — — — — — — 5 cartons of 5 — — — — — THQL32015 THQL32020 THQL32025 THQL32030 THQL32035 THQL32040 THQL32045 THQL32050 THQL32060 THQL32070 THQL32080 THQL32090 THQL32100 5 cartons of 3 — — — — — — — — — — — — — — THHQL32015 THHQL32020 THHQL32025 THHQL32030 THHQL32035 THHQL32040 THHQL32045 THHQL32050 THHQL32060 THHQL32070 THHQL32080 THHQL32090 THHQL32100 5 cartons of 3 TXQL32015 TXQL32020 TXQL32025 TXQL32030 UL Listed as HACR (heating, air conditioning, and refrigeration). UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads. 15–100 A UL Listed as HACR (heating, air conditioning, and refrigeration.). Requires four 1-inch spaces. 7 5 cartons of 3 GE OEM Load Center Parts Program Q Line Circuit Breakers Main Circuit Breaker Kits • For use with PowerMark Gold OEM Interiors with TLM prefix. • 60°/75° C Conductor Rating • Quick-Make, Quick-Break • Multipole Breakers Incorporate Internal Common Trip • Box-Type Terminals PowerMark Gold™ Main Circuit Breakers PowerMark Plus™ Main Circuit Breakers • • • • • • • • • Two-pole, 120/240 Vac For use with 150–225 A PowerMark Gold load centers 22 kAIC RMS symmetrical Includes mounting base For Specialty Load Center interiors with a main circuit breaker and lugs, use catalog number THQMV__WL, with the appropriate main breaker rating inserted in the space. Main-Breaker Rating,-A 100 125 150 175 200 225 Ampere Rating 100 125 150 175 200 225 Cat.-No. Top-Feed Bottom-Feed THQMV100 THQMV100B THQMV125 THQMV125B THQMV150 THQMV150B THQMV175 THQMV175B THQMV200 THQMV200B THQMV225 THQMV225B THQMV200 PowerMark Gold Main Circuit Breaker Kits • Two-pole, 120/240 Vac or 240 Vac • For use with 125 A PowerMark Gold load centers Main-Breaker-Kit TQMH000 Cat.-No. Description Order appropriate THQL (10 kAIC) or THHQL (22 kAIC) breakers separately TQMH000 with breaker Main Breaker Retainers For Main Lug Load Centers Using a Back-Fed Branch Breaker as a Main Load-Center Breaker Cat-No. TL (225 A max) THQL TQDL PowerMark Gold THQL THQLRK TQDLRK THQLRK1 THQLRK2 Three-pole, 240 Vac For use with 125-225A PowerMark Plus Interiors Line LUgs only included Breaker Mounting Bracket indicated on Drawings Std. Pkg. 1 THQLRK1 For six- or eight-circuit load centers. 8 Catalog-Number 10- kAIC TQD32100X2 TQD32125X2 TQD32150X2 TQD32175X2 TQD32200X2 TQD32225X2 22- kAIC THQD32100X2 THQD32125X2 THQD32150X2 THQD32175X2 THQD32200X2 THQD32225X2 Wire Range #1–300 Cu or 2/0–300 Al GE OEM Load Center Parts Program Q Line Circuit Breakers Surge Arrester CB3® Ground Fault • UL Listed (1449) • Meets ANSI/IEEE Standard C62.11-1987 • Protects all circuits connected to load centers in which it is installed • UL Listed (Molded-Case Circuit Breakers No. 489 and Ground Fault Circuit Interrupters No. 943) • Class A (.005 Ampere ground fault trip level) Response Time: Clamping voltage; Maximum surge current: Reaction time: Less than 1 nanosecond 500 V 27,000 A 1 microsecond 1-Pole 120- Vac Ampere Rating Cat.-No. 15 THQL1115GF 20 THQL1120GF 10 kAIC 30 THQL1130GF 40 — 50 — 15 THHQL1115GF 22 kAIC 20 THHQL1120GF 30 THHQL1130GF Std. Pkd. 10 cartons of 1 Cat.-No. THQLSURGE THQLSURGE Arc Fault Circuit Interrupters • UL Listed (Molded-Case Circuit Breakers No. 489) • UL Classified for mitigating the effects of arc faults • 10 kAIC RMS symmetrical Ampere Rating 15 20 2-Pole 120/240- Vac Cat.-No. THQL2115GF1 THQL2120GF1 THQL2130GF1 THQL2140GF1 THQL2150GF1 — — — 10 cartons of 1 THQL1120GF Switching Neutral • UL Listed (Molded-Case Circuit Breakers No. 489) • 10 kAIC RMS symmetrical • Standard one- or two-pole automatic breaker plus one fully rated, nonautomatic pole 1-Pole,-120/240- Vac Cat.-No. THQL1115AF THQL1120AF THQL1115AF Rating,-A 15 20 25 30 Std. Pkg. 9 1-Pole-plus Switching-Neutral 120/240- Vac Cat.-No. THQL21WY15 THQL21WY20 THQL21WY25 THQL21WY30 5 cartons of 5 2-Pole-plus Switching-Neutral 120/240- Vac Cat.-No. THQL31WY15 THQL31WY20 THQL31WY25 THQL31WY30 5 cartons of 5 THQL21WY20 GE OEM Load Center Parts Program Q Line Circuit Breakers HID Lighting Molded-Case Switches • UL Listed (Molded-Case Circuit Breakers No. 489) • HID breakers have been designed to handle the current and voltage spikes that result when gaseous discharge lamps, including fluorescent and HID lamps, are switched on and off. • UL Listed (Molded-Case Switches No. 1087) • Without overload or short-circuit protection Vac 1-Pole 120/240- Vac Ampere Rating Cat.-No. 15 THQL1115HID 10 kAIC 20 THQL1120HID 30 THQL1130HID 15 THHQL1115HID 22 kAIC 20 THHQL1120HID 30 THHQL1130GF Std. Pkg. 5 cartons of 10 Rating,-A 60 120/240 100 60 240 100 Std. Pkg. 2-Pole 120/240- Vac Cat.-No. THQL2115HID THQL2120HID THQL2130HID THHQL2115HID THHQL2120HID THHQL2130HID 5 cartons of 10 TQL21Y100 • 3/4-inch wide • 10 kAIC RMS symmetrical • UL Classified • For use in Square D QO® load centers Rating,-A 15 20 30 40 50 60 Std. Pkg. THQL1120HID High Magnetic • UL Listed (Molded-Case Circuit Breakers No. 489) • 10 kAIC RMS symmetrical • High short-circuit setting suitable for circuits with inherent high inrush load currents 1-Pole 120- Vac Cat.-No. THQL1115HM THQL1120HM THQL1125HM THQL1130HM THQL1140HM THQL1150HM 5 cartons of 10 3-Pole Cat.-No. — — TQL32Y60 TQL32Y100 5 cartons of 3 TQ Circuit Breakers UL Listed as SWD (switching duty). Suitable for 120 Vac fluorescent lighting loads. Ampere Rating 15 20 25 30 40 50 Std. Pkg. 2-Pole Cat.-No. RQL21Y60 TQL21Y100 TQL22Y60 TQL22Y100 5 cartons of 5 THQL1140HM 10 1-Pole Cat.-No. TQ1115 TQ1120 TQ1130 TQ1140 TQ1150 — 1 carton of 10 2-Pole Cat.-No. TQ2115 TQ2120 TQ2130 TQ2140 TQ2150 TQ2160 1 carton of 5 TQ1120 GE OEM Load Center Parts Program Load Center Accessories Equipment Ground Kits Neutral Kits PowerMark Plus Equipment Ground Kits PowerMark Plus Neutral Kits Small-14–8 Cu,-12–8-Al 4 7 11 14 10 — — — Number-of-Terminals Large-14–4 Other-AWG/ Cu,-12–4-Al kcmil-Cu/Al 3 — — — 3 — — — 2 (1) 14–2 — (1) 6–2/0 — (3) 10–1/0 — (6) 10–1/0 Cat.-No. TGL1 TGL3 TGL2 TGL4 TGL8 TGL20 TNG3 TNG6 Wire-Size-AWG/ kcmil-Cu/Al (5) 14–1/0 (3) 1–300 (1) 6–2/0 (1) 1–300 Cu or 2/0–300 Al Std.-Pkg. Cat.-No. TNLK1 TNLK2 286A8894G1 192A7663G13 Std.-Pkg. 1 Suitable only for 400 and 600 amp devices. Add-on neutral lug kit for 100–200 amp load centers. 20 PowerMark Gold Neutral and Neutral Ground Kits TGL1 and TGL3 mount interchangeably. TGL2, TGL4, and TGL8 mount interchangeably. Add-on equipment ground lug (for use on any TGL kit). Suitable only for 400 and 600 amp devices. Description Neutral Neutral Neutral Neutral/Ground Neutral/Ground 1 Wire-Size,-Cu/Al 6–1 6–2/0 6–250 6–2/0 6–250 Cat.-No. TNLK12 TNLK20 TNLK250 TLK20 TLK250 Std.-Pkg. 1 PowerMark Gold and Three-Phase PowerMark Plus Equipment Ground and Isolated Ground Bus Bar Description-(4–14-Cu/10–12-Al-Wire Ranges per-Hole,-Solid-or-Stranded) 12-hole Ground 24-Hole Ground 32-Hole Ground 42-Hole Ground Isolated Ground Bus Bar Kit (Order with TGK Equipment Ground Kits) Cat.No. TGK12 TGK24 TGK32 TGK42 Std.Pkg. TNLK1 1 TGKIS TLK20 shown attached to neutral/ground bar TLK250 shown attached to neutral/ground bar TNLK20 TNLK250 TLK20 TLK250 TGL2 TGK12 with TGKIS Main Lug Kits TGK12 Load-Center-Type PowerMark Plus PowerMark Gold THLK200 11 Wire-Size AWG/kcmil-Cu/Al 2–3/0 1–250 6–2/0 6–250 6–300 Ampere-Rating 150 200 125 200 225 TMLK200 Cat.-No. THLK150 THLK200 TMLK125 TMLK200 TMLK225 GE OEM Load Center Parts Program Load Center Accessories Door Lock Description For all indoor load centers except TPL412 Handle Locks (Padlocking) Cat.-No. Std.-Pkg. TDL106 10 Breaker THQP THQL TQDL TQD TDL106 Circuit Directory Description Card and holder with pressure-sensitive backing. Mounts inside door. ON or OFF, Snap-On, Padlock Not Included Cat.-No. Std.-Pkg. TD42 1 Cat.-No. TQPPL THP100 TQDLPDL1 TQQPLD1 Std.-Pkg. 10 THP100 Handle Locks (Non-Padlocking) ON or OFF, Snap-On Description 12.75 oz. spray can of light-gray enamel Breaker THQP THQL TD42 Touch-Up Paint Cat.-No. Std.-Pkg. TSP61 1 Cat.-No. TQPL THL103 Std.-Pkg. 10 THL103 Handle Ties For Two Single-Pole Breakers TSP61 Front Filler Plates (all multipole breakers have internal common trip) (to cover rectangular breaker knockouts) Knockout-Width 1/2" 1" Cat.-No. TFH TQLFP1 Breaker Std.-Pkg. 100 50 THQP TFH Universal Rain-Tight Hubs (Aluminum) THQL Description Solid Snap-On Trip Indicating For two THQPs separated by two side-by-side THQPs Solid Snap-On Trip Indicating Cat-No. Std. Pkg. THT1 100 THT2 20 THT104 TQHT1 50 20 For Outdoor Enclosures with Removable Closing Caps Nominal-Conduit-Diameter in-Inches 3/4 1 11/4 11/2 2 21/2 Closing Cap 3 Cat.-No. TC75 TC100 TC125 TC150 TC200 TC250 TCCP TC300 Std.-Pkg. Cat.-No. TRL22 TRL22B Std.-Pkg. Load Center Hardware & Hardware Kits Description PowerMark Gold bond screw kit with one bond screw PowerMark Gold hardware kit with 20 front-mounting screws 10 5 TC150 Door Handles Location-of-Main-Lugs-or Main-Breaker Top Bottom 1 TRL22 12 Cat.-No. TBS THDWRKIT Std.-Pkg. 1 THT1, THT2, THT104 GE OEM Load Center Parts Program Load Center Accessories Residential Circuit Breaker Enclosures • • • • UL Listed Suitable for use as service entrance Short-circuit ratings equal to the installed breaker Steel enclosures TQD200NRE Breaker Type THQL, THQL-GF, TXQL TQD, THQD Max. Amp Rating Poles 100 1, 2, 3 225 THQMV Type-1-Indoor Enclosure — TQL100F TQL100S 2 — 2, 3 TQD225F TQD225S 2 — Cat.-No. Type-3R-Outdoor Enclosure TQL100RE TQL100R TQD225NR TQD150NRE TQD200NRE TQD225R THMQMV150NRE THMQMV200NRE F – flush, S – surface, C – combination 100– 250 A devices have removable closing caps. Larger amp devices require field-cut openings. Order hubs separately. 100 A circuit breaker factory installed. Suitable only for two-pole breaker. 150 and 200 A circuit breaker factory installed. Subfeed and Feed-Through Lugs • UL Listed • For use in load centers to economically supply power to subpanel • Includes mounting base Poles 2 3 2 2 3 Rating,-A 125 125 150 200 225 Cat.-No. THLK2125 THLK3125 THLK2150 THLK2200 THLK3225 THLK2125 For use with PowerMark Gold load centers only. 13 GE OEM Load Center Parts Program TLM612U2 Interior Assembly Part Number TLM612U2 TLM612U2N THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior with neutral, 6 Circuit, 125 A, Cu Interior without neutral, 6 Circuit, 125 A, Cu Interior Mounting Screw Kit 1 10 10 10 Flush Front, TLM612FCU Flush Front with Door, TLM612FCUD Surface Front, TLM612SCU Surface Front with Door, TLMSCUD Front Mounting Screw Kit 1 1 1 1 20 1 1 1 1 1 Box Assembly 1 72 Bonding Screw Kit Equipment Ground Kit 1 1 1 200 Front Assembly TLM6FC TLM6FCD TLM6SC TLM6SCD THDWRKIT Box Assembly LC612BOX Accessories TBS TGK12 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 125 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 6 3 12 4 14 Total 1-Pole Spaces 12 GE OEM Load Center Parts Program TLM612U2 Equipment Ground Terminations UL listed (Panelboards No. 67) Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 6–3 Cu-Al Neutral Lugs 6–2/0 Cu-Al Flush Mount – TLM612FCU 15 GE OEM Load Center Parts Program TLM612U2 UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. Surface Mount – TLM612SCU 16 GE OEM Load Center Parts Program TLM812U2 Interior Assembly Part Number TLM812U2 TLM812U2N THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior with neutral, 8 Circuit, 125 A, Cu Interior without neutral, 8 Circuit, 125 A, Cu Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan, Flush Mount Door, Flush Mount, Front Assembly Assembly, Front and Pan, Surface Mount Door, Surface Mount, Front Assembly Front Mounting Screw Kit 1 1 1 1 20 1 1 1 1 20 Box Assembly 1 72 Bonding Screw Kit Equipment Ground Kit 1 1 1 200 Front Assembly TLM8FC TLM8FCD TLM8SC TLM8SCD THDWRKIT Box Assembly LC612BOX Accessories TBS TGK12 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 125 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 8 4 16 6 17 Total 1-Pole Spaces 16 GE OEM Load Center Parts Program TLM812U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al UL listed (Panelboards No. 67) Stranded, AWG 14–4 Cu 12–4 Al 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 6–3 Cu-Al Neutral Lugs 6–2/0 Cu-Al Flush Mount – TLM812FCU 18 GE OEM Load Center Parts Program TLM812U2 UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. Surface Mount – TLM812SCU 19 GE OEM Load Center Parts Program TLM1212U2 Interior Assembly Part Number TLM1212U2 THDWRKIT2 Description Interior, 12 circuit, 100–125 A, Cu Interior Mounting Screw Kit Min. Qty. Master Pack Qty. 1 10 10 10 Front Assembly TLM12BC TM12FC 139C5515P2 192A6597P1 THDWRKIT Assembly, Front and Pan For convertible main For main breaker units Door Hinge Front Mounting Screw Kit 1 1 1 3 20 1 1200 20 Box Assembly 1 40 Bonding Screw Kit Equipment Ground Kit 1 1 1 200 Box Assembly LC1212BOX Accessories TBS TGK12, TGK24 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 125 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 12 6 24 10 20 Total 1-Pole Spaces 24 Main Breaker Conv Kit TQMH000 GE OEM Load Center Parts Program TLM1212U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 6–2/0 Cu-Al (TLM1212) 4–1/0 Cu-Al (TM1210) 1–2/0 Cu-Al (TM1212) Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 21 GE OEM Load Center Parts Program TLM1612U2 Interior Assembly Part Number TLM1612U2 THDWRKIT2 Description Interior, 16 circuit, 125 A, Cu Interior Mounting Screw Kit Min. Qty. Master Pack Qty. 1 10 10 10 Front Assembly TLM16DC TM16EC 139C5515P2 192A6597P1 THDWRKIT Assembly, Front and Pan For convertible main For main breaker units Door Hinge Front Mounting Screw Kit 1 1 1 3 20 1 1200 20 Box Assembly 1 40 1 1 1 200 Box Assembly LC1212BOX Accessories TBS TGK12, TGK24 Bonding Screw Kit Equipment Ground Kit OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 125 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 16 8 16 6 22 Total 1-Pole Spaces 24 Main Breaker Conv Kit TQMH000 GE OEM Load Center Parts Program TLM1612U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 1–2/0 Cu-Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 23 GE OEM Load Center Parts Program TLM2412U2 Interior Assembly Part Number TLM2412U2 THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 24 circuit, 125 A, Cu Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TLM24BC 139C5515P3 192A6597P1 THDWRKIT Box Assembly LC24415BOX Accessories TBS TGK24 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 125 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 24 12 — — 24 Total 1-Pole Spaces 24 Main Breaker Conv Kit TQMH000 GE OEM Load Center Parts Program TLM2412U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 6–2/0 Cu-Al (TLM) 1–2/0 Cu-Al (TM) Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 25 GE OEM Load Center Parts Program TLM2415U2 Interior Assembly Part Number TLM2415U2 THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 24 circuit, 150 A, Cu Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TM24EC 139C5515P3 192A6597P1 THDWRKIT Box Assembly LC2015BOX Accessories TBS TGK24, TGK32 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 150 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 24 12 12 4 26 Total 1-Pole Spaces 30 Main Breaker Conv Kit THQMV150 GE OEM Load Center Parts Program TLM2415U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 1–2/0 Cu 2/0–3/0 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 27 GE OEM Load Center Parts Program TLM1620U2 Interior Assembly Part Number TLM1620U2 THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 16 circuit, 200 A, Cu Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TM16GC 139C5515P3 192A6597P1 THDWRKIT Box Assembly LC1620BOX Accessories TBS TGK32 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 150 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 16 8 32 16 28 Total 1-Pole Spaces 32 Main Breaker Conv Kit THQMV200 GE OEM Load Center Parts Program TLM1620U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 1–250 Cu 2/0–250 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 29 GE OEM Load Center Parts Program TLM2020U2 Interior Assembly Part Number TLM2020U2 THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 20 circuit, 200 A, Cu Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TM20EC 139C5515P3 192A6597P1 THDWRKIT Box Assembly LC2015BOX Accessories TBS TGK24, TGK42 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 20 10 40 18 30 Total 1-Pole Spaces 40 Main Breaker Conv Kit THQMV200 GE OEM Load Center Parts Program TLM2020U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 1–250 Cu 2/0–250 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 31 GE OEM Load Center Parts Program TLM3220U2 Interior Assembly Part Number TLM3220U2 THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 32 circuit, 200 A, Cu Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TM32FC 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC3220BOX Accessories TBS TGK32 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 32 16 16 6 32 Total 1-Pole Spaces 40 Main Breaker Conv Kit THQMV200 GE OEM Load Center Parts Program TLM3220U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 1–250 Cu 2/0–250 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 33 GE OEM Load Center Parts Program TLM4020U2 Interior Assembly Part Number TLM4020U2 THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 40 circuit, 200 A, Cu Interior Mounting Screw Kit 1 10 6 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TM40BC 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC4020BOX Accessories TBS TGK42 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 40 20 — — 34 Total 1-Pole Spaces 40 Main Breaker Conv Kit THQMV200 GE OEM Load Center Parts Program TLM4020U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 1–250 Cu 2/0–250 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 35 GE OEM Load Center Parts Program TLM4222U2 Interior Assembly Part Number TLM4222U2 THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 42 circuit, 225 A, Cu Interior Mounting Screw Kit 1 10 6 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 16 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TM42BC 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC4222BOX Accessories TBS TGK42 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 225 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 42 20 — — 36 Total 1-Pole Spaces 42 Main Breaker Conv Kit THQMV225 GE OEM Load Center Parts Program TLM4222U2 Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 1–250 Cu 2/0–250 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 37 GE OEM Load Center Parts Program TL12412U Interior Assembly Part Number TL12412U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 12 circuit, 3-phase, 125 A, MLO Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 40 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TL12AC3 139C5515P2 192A6597P1 THDWRKIT Box Assembly LC1212BOX Accessories TBS TGK12, TGK24 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 125 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 12 6 4 Total 1-Pole Spaces 12 Alternate backfed main breaker rating: 100 A max. THQL style Main breaker retainer required: THQLRK 38 GE OEM Load Center Parts Program TL12412U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 6–2/0 Cu-Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 39 GE OEM Load Center Parts Program TL18415U Interior Assembly Part Number TL18415U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 18 circuit, 3-phase, 150 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TL18BC3 139C5515P3 192A6597P1 THDWRKIT 20 Box Assembly LC24415BOX Accessories TBS TGK24, TGK32 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 150 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 18 8 6 Total 1-Pole Spaces 18 Alternate backfed main breaker rating: 100 A max. Main breaker retainer required: THQLRK 40 GE OEM Load Center Parts Program TL18415U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–3/0 Cu 2/0–3/0 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 41 GE OEM Load Center Parts Program TL24415U Interior Assembly Part Number TL24415U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 24 circuit, 3-phase, 150 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TL24AC3 139C5515P3 192A6597P1 THDWRKIT Box Assembly LC24415BOX Accessories TBS TGK24, TGK32 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 150 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 24 12 8 Total 1-Pole Spaces 24 Alternate backfed main breaker rating: 100 A max. Main breaker retainer required: THQLRK 42 GE OEM Load Center Parts Program TL24415U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–3/0 Cu 2/0–3/0 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 43 GE OEM Load Center Parts Program TL18420U Interior Assembly Part Number TL18420U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 18 circuit, 3-phase, 200 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TL18DC3 139C5515P3 192A6597P1 THDWRKIT Box Assembly LC1620BOX Accessories TBS TGK32 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 18 8 6 Total 1-Pole Spaces 18 Alternate backfed main breaker rating: 100 A max. Main breaker retainer required: THQLRK 44 GE OEM Load Center Parts Program TL18420U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–10 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Wire Sizes Line 1–250 Cu 2/0–250 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 45 GE OEM Load Center Parts Program TL30420U Interior Assembly Part Number TL30420U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 30 circuit, 3-phase, 200 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 3 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TL30BC3 139C5515P5 192A6597P1 THDWRKIT 1 20 1 1 1200 20 Box Assembly LC30420BOX Accessories TBS TGK32 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 30 14 10 Total 1-Pole Spaces 30 Alternate backfed main breaker rating: 100 A max. Main breaker retainer required: THQLRK 46 GE OEM Load Center Parts Program TL30420U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–250 Cu, 2/0–250 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 47 GE OEM Load Center Parts Program TL42420U Interior Assembly Part Number TL42420U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 42 circuit, 3-phase, 200 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TL42BC3 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC4020BOX Accessories TBS TGK42 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 42 20 14 Total 1-Pole Spaces 42 Alternate backfed main breaker rating: 100 A max. Main breaker retainer required: THQLRK 48 GE OEM Load Center Parts Program TL42420U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–250 Cu 2/0–250 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 49 GE OEM Load Center Parts Program TL30422U Interior Assembly Part Number TL30422U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 30 circuit, 3-phase, 225 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 14 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TL30AC3 139C5515P4 192A6597P1 THDWRKIT Box Assembly LC30422BOX Accessories TBS TGL2 (two) OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 225 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 30 14 10 Total 1-Pole Spaces 30 Alternate backfed main breaker rating: 100 A max. Main breaker retainer required: THQLRK 50 GE OEM Load Center Parts Program TL30422U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–300 Cu 2/0–300 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 51 GE OEM Load Center Parts Program TL42422U Interior Assembly Part Number TL42422U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 42 circuit, 3-phase, 225 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 14 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TL42AC3 139C5515P4 192A6597P1 THDWRKIT Box Assembly LC30422BOX Accessories TBS TGL2 (two) OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 225 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 42 20 14 Total 1-Pole Spaces 42 Alternate backfed main breaker rating: 100 A max. Main breaker retainer required: THQLRK 52 GE OEM Load Center Parts Program TL42422U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–300 Cu 2/0–300 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 53 GE OEM Load Center Parts Program TM12410U Interior Assembly Part Number TM12410U THDWRKIT2 THHQL32100 THQLRK Description Min. Qty. Master Pack Qty. Interior, 12 circuit, 3-phase, 100 A Interior Mounting Screw Kit Main Breaker, 3-pole, 100 A THQL Retainer Kit 1 10 1 1 10 10 15 200 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 40 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TM12AC3 139C5515P3 192A6597P1 THDWRKIT Box Assembly LC18410BOX Accessories TBS TGK12, TGK24 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 100 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 12 6 4 Note: Main breaker included. 54 Total 1-Pole Spaces 12 GE OEM Load Center Parts Program TM12410U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 6–1/0 Cu, 4–1/0 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 55 GE OEM Load Center Parts Program TM18410U Interior Assembly Part Number TM18410U THDWRKIT2 THHQL32100 THQLRK Description Min. Qty. Master Pack Qty. Interior, 18 circuit, 3-phase, 100 A Interior Mounting Screw Kit Main Breaker, 3-pole, 100 A THQL Retainer Kit 1 10 1 1 10 10 15 200 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 40 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Front Assembly TM18AC3 139C5515P3 192A6597P1 THDWRKIT Box Assembly LC18410BOX Accessories TBS TGK24, TGK32 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 100 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 18 8 6 Note: Main breaker included. 56 Total 1-Pole Spaces 18 GE OEM Load Center Parts Program TM18410U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 6–1/0 Cu, 4–1/0 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 57 GE OEM Load Center Parts Program TM30412U Interior Assembly Part Number TM30412U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 30 circuit, 3-phase, 125 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit Circuit Breaker, TQD225 Style ASM, Support Bracket, Breaker Screw, Support Bracket Mounting Screw, Breaker Mounting to Bracket Screw, Breaker Load Connection 1 1 1 1 1 1 3 1 1 1 200 200 200 200 Front Assembly TM30EC3 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC30420BOX Accessories TBS TGK32 THQD32125X2 315A7060G2 N667CP12004B6 N37P17042B6 192A6976P167 58 GE OEM Load Center Parts Program TM30412U OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 125 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 30 14 10 Total 1-Pole Spaces 30 Note: Main breaker and accessories not included with OEM interior; order separately. 59 GE OEM Load Center Parts Program TM30412U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–3/0 Cu, 2/0–3/0 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 60 GE OEM Load Center Parts Program TM24415U Interior Assembly Part Number TM24415U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 24 circuit, 3-phase, 150 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit Circuit Breaker, TQD225 Style ASM, Support Bracket, Breaker Screw, Support Bracket Mounting Screw, Breaker Mounting to Bracket Screw, Breaker Load Connection 1 1 1 1 1 1 3 1 1 1 200 200 200 200 Front Assembly TM24EC3 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC30420BOX Accessories TBS TGK32 THQD32150X2 315A7060G2 N667CP12004B6 N37P17042B6 192A6976P167 61 GE OEM Load Center Parts Program TM24415U OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 150 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 24 12 8 Total 1-Pole Spaces 24 Note: Main breaker and accessories not included with OEM interior; order separately. 62 GE OEM Load Center Parts Program TM24415U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–3/0 Cu, 2/0–3/0 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 63 GE OEM Load Center Parts Program TM30415U Interior Assembly Part Number TM30415U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 30 circuit, 3-phase, 150 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit Circuit Breaker, TQD225 Style ASM, Support Bracket, Breaker Screw, Support Bracket Mounting Screw, Breaker Mounting to Bracket Screw, Breaker Load Connection 1 1 1 1 1 1 3 1 1 1 200 200 200 200 Front Assembly TM30EC3 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC30420BOX Accessories TBS TGK32 THQD32150X2 315A7060G2 N667CP12004B6 N37P17042B6 192A6976P167 64 GE OEM Load Center Parts Program TM30415U OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 150 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 30 14 10 Total 1-Pole Spaces 30 Note: Main breaker and accessories not included with OEM interior; order separately. 65 GE OEM Load Center Parts Program TM30415U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–3/0 Cu, 2/0–3/0 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 66 GE OEM Load Center Parts Program TM42415U Interior Assembly Part Number TM42415U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 42 circuit, 3-phase, 150 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit Circuit Breaker, TQD225 Style ASM, Support Bracket, Breaker Screw, Support Bracket Mounting Screw, Breaker Mounting to Bracket Screw, Breaker Load Connection 1 1 1 1 1 1 3 1 1 1 200 200 200 200 Front Assembly TM42EDC3 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC4020BOX Accessories TBS TGK42 THQD32150X2 315A7060G2 N667CP12004B6 N37P17042B6 192A6976P167 67 GE OEM Load Center Parts Program TM42415U OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 150 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 42 20 14 Total 1-Pole Spaces 42 Note: Main breaker and accessories not included with OEM interior; order separately. 68 GE OEM Load Center Parts Program TM42415U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–3/0 Cu, 2/0–3/0 Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 69 GE OEM Load Center Parts Program TM24420U Interior Assembly Part Number TM24420U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 24 circuit, 3-phase, 200 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit Circuit Breaker, TQD225 Style ASM, Support Bracket, Breaker Screw, Support Bracket Mounting Screw, Breaker Mounting to Bracket Screw, Breaker Load Connection 1 1 1 1 200 200 200 200 Front Assembly TM24DC3 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC30420BOX Accessories TBS TGK32 THQD32200X2 315A7060G2 N667CP12004B6 N37P17042B6 192A6976P167 70 1 1 1 1 3 GE OEM Load Center Parts Program TM24420U OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 24 12 8 Total 1-Pole Spaces 24 Note: Main breaker and accessories not included with OEM interior; order separately. 71 GE OEM Load Center Parts Program TM24420U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–300 MCM Cu, 2/0–300 MCM Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 72 GE OEM Load Center Parts Program TM30420U Interior Assembly Part Number TM30420U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 30 circuit, 3-phase, 200 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit Circuit Breaker, TQD225 Style ASM, Support Bracket, Breaker Screw, Support Bracket Mounting Screw, Breaker Mounting to Bracket Screw, Breaker Load Connection 1 1 1 1 1 1 3 1 1 1 200 200 200 200 Front Assembly TM30DC3 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC3220BOX Accessories TBS TGK32 THQD32200X2 315A7060G2 N667CP12004B6 N37P17042B6 192A6976P167 73 GE OEM Load Center Parts Program TM30420U OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 30 14 10 Total 1-Pole Spaces 30 Note: Main breaker and accessories not included with OEM interior; order separately. 74 GE OEM Load Center Parts Program TM30420U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–250 MCM Cu, 2/0–250 MCM Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 75 GE OEM Load Center Parts Program TM42420U Interior Assembly Part Number TM42420U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 42 circuit, 3-phase, 200 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 1 1 1200 Box Assembly 1 16 Bonding Screw Kit Equipment Ground Kit Circuit Breaker, TQD225 Style ASM, Support Bracket, Breaker Screw, Support Bracket Mounting Screw, Breaker Mounting to Bracket Screw, Breaker Load Connection 1 1 1 1 1 1 3 1 1 1 200 200 200 200 Front Assembly TM42EC3 139C5515P5 192A6597P1 THDRWKIT 20 20 Box Assembly LC4222BOX Accessories TBS TGK42 THQD32200X2 315A7060G2 N667CP12004B6 N37P17042B6 192A6976P167 76 GE OEM Load Center Parts Program TM42420U OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 42 20 14 Total 1-Pole Spaces 42 Note: Main breaker and accessories not included with OEM interior; order separately. 77 GE OEM Load Center Parts Program TM42420U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–250 MCM Cu, 2/0–250 MCM Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 78 GE OEM Load Center Parts Program TM42422U Interior Assembly Part Number TM42422U THDWRKIT2 Description Min. Qty. Master Pack Qty. Interior, 42 circuit, 3-phase, 225 A Interior Mounting Screw Kit 1 10 10 10 Assembly, Front and Pan Door Hinge Front Mounting Screw Kit 1 1 3 20 1 1 1200 20 Box Assembly 1 24 Bonding Screw Kit Equipment Ground Kit Circuit Breaker, TQD225 Style ASM, Support Bracket, Breaker Screw, Support Bracket Mounting Screw, Breaker Mounting to Bracket Screw, Breaker Load Connection 1 1 1 1 1 1 3 1 1 1 200 200 200 200 Front Assembly TM42BC3 139C5515P5 192A6597P1 THDWRKIT Box Assembly LC30422BOX Accessories TBS TGL2 (two) THQD32225X2 315A7060G4 N667CP12004B6 N37P17042B6 192A6976P167 79 GE OEM Load Center Parts Program TM42422U OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 225 Maximum Spaces 1" THQL 1-Pole 2-Pole 3-Pole 42 20 14 Total 1-Pole Spaces 42 Note: Main breaker and accessories not included with OEM interior; order separately. 80 GE OEM Load Center Parts Program TM42422U Equipment Ground Terminations Solid, AWG 14–4 Cu 12–10 Al Stranded, AWG 14–4 Cu 12–4 Al Neutral Terminations Solid, AWG 14–8 Cu 12–8 Al Stranded, AWG 12–4 Cu 12–4 Al Wire Sizes Line 1–300 MCM Cu, 2/0–300 MCM Al Neutral Lugs 6–2/0 Cu-Al UL listed (Panelboards No. 67) 60° C and 75° C conductor rating. 22,000 amperes RMS symmetrical short-circuit rating. 81 GE OEM Load Center Parts Program TSF420U Interior Assembly Part Number TSF420U THDWRKIT2 TSF420UN Description Min. Qty. Master Pack Qty. Interior, 4 circuits 1" or 8 circuits 1/2", 1-phase, 200 A Interior Mounting Screw Kit Interior Without Neutral Assembly 1 10 10 1 10 10 Bonding Screw Kit Equipment Ground Kit Main Breaker Retaining Kit 1 1 1 1 1 1 Accessories TBS TGK12 THQLRK1 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 4 2 8 3 82 Total 1-Pole Spaces 8 GE OEM Load Center Parts Program TSLR420U Interior Assembly Part Number TSLR420U THDWRKIT2 TSLR420UN Description Min. Qty. Master Pack Qty. Interior, 4 circuits 1" or 8 circuits 1/2", 1-phase, 200 A (125 A for TSLR412CSCU) Interior Mounting Screw Kit Interior Without Neutral Assembly 1 10 10 1 10 10 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Accessories TBS TGK12 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 4 2 8 3 83 Total 1-Pole Spaces 8 GE OEM Load Center Parts Program TSM1212U Interior Assembly Part Number TSM1212U THDWRKIT2 TSM1212UN Description Min. Qty. Master Pack Qty. Interior, 12 circuits 1" or 24 circuits 1/2", 1-phase, 125 A Interior Mounting Screw Kit Interior Without Neutral Assembly 1 10 10 1 10 10 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Accessories TBS TGK12 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 125 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 12 6 24 10 Total 1-Pole Spaces 24 Note: Reverse-fed main breaker retainer not available. 84 GE OEM Load Center Parts Program TSM1610U Interior Assembly Part Number TSM1610U THDWRKIT2 TSM1610UN Description Min. Qty. Master Pack Qty. Interior, 16 circuits 1" or 32 circuits 1/2", 1-phase, 100 A Interior Mounting Screw Kit Interior Without Neutral Assembly 1 10 10 1 10 10 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Accessories TBS TGK12 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 100 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 16 8 32 14 Total 1-Pole Spaces 32 Note: Reverse-fed main breaker retainer not available. 85 GE OEM Load Center Parts Program TSM2020U Interior Assembly Part Number TSM2020U THDWRKIT2 TSM2020UN Description Min. Qty. Master Pack Qty. Interior, 20 circuits 1" or 40 circuits 1/2", 1-phase, 200 A Interior Mounting Screw Kit Interior Without Neutral Assembly 1 10 10 1 10 10 Bonding Screw Kit Equipment Ground Kit Main Breaker Retaining Kit 1 1 1 1 1 1 Accessories TBS TGK12 THQLRK1 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 20 10 40 18 86 Total 1-Pole Spaces 40 GE OEM Load Center Parts Program TSM820U Interior Assembly Part Number TSM820U THDWRKIT2 TSM820UN Description Min. Qty. Master Pack Qty. Interior, 8 circuits 1" or 16 circuits 1/2", 1phase, 200 A (150 A for TSM820CSCU) Interior Mounting Screw Kit Interior Without Neutral Assembly 1 10 10 1 10 10 Bonding Screw Kit Equipment Ground Kit Main Breaker Retaining Kit 1 1 1 1 1 1 Accessories TBS TGK12 THQLRK1 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 8 4 16 6 87 Total 1-Pole Spaces 16 GE OEM Load Center Parts Program TSMR1212U Interior Assembly Part Number TSMR1212U THDWRKIT2 TSMR1212UN Description Min. Qty. Master Pack Qty. Interior, 12 circuits 1" or 24 circuits 1/2", 1-phase, 125 A Interior Mounting Screw Kit Interior Without Neutral Assembly 1 10 10 1 10 10 Bonding Screw Kit Equipment Ground Kit Main Breaker Mounting Kit Reverse-Fed Retaining Kit – Alternate 1 1 1 1 1 1 1 1 Accessories TBS TGK12 TQMH000 THQLKR1 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 125 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 12 6 24 10 For use with THQL, THHQL, or TXQL main breaker. 88 Total 1-Pole Spaces 24 GE OEM Load Center Parts Program TSMR2015U Interior Assembly Part Number TSMR2015U THDWRKIT2 TSMR2015UN Description Min. Qty. Master Pack Qty. Interior, 20 circuits 1" or 40 circuits 1/2", 1phase, 150 A (200 A for TSMR2020CSCU) Interior Mounting Screw Kit Interior Without Neutral Assembly 1 10 10 1 10 10 Bonding Screw Kit Equipment Ground Kit 1 1 1 1 Accessories TBS TGK12 OEM interiors are UL-recognized components listed under UL file E21790. Main Ampere Rating 200 Maximum Spaces 1/2" THQL 1" THQL 1-Pole 2-Pole 1-Pole 2-Pole 20 10 40 18 Total 1-Pole Spaces 40 For main breaker, order THQMV main breaker; includes mounting base. Reverse-fed main breaker available, 100 A max. rating, with THQLRK1 retaining kit. 89