kVp, mAs, mA, Dose and Exposure Time Meter All Purpose X-ray Meter Model UXI – Universal X-Ray Instrument This Instrument Measures kVp, mA, mAs, Dose, HVL and Exposure Time The new Universal X-ray Instrument (UXI) is capable of measuring x-ray kVp, mA, mAs, Dose, HVL and exposure time. One exposure is needed for kVp, mA, mAs and dose. Three exposures are needed for an accurate HVL measurement. The built in HVL calculator is used to calculate HVL. Each UXI comes with a 7 inch (178 mm) Android tablet. With the programmable delay, the unit is capable of measuring kVp for exposure times as low as 16 milliseconds. This allows shorter exposure times minimizing xray exposure and wear and tear on the x-ray head. The kVp measurement circuit and control program have been greatly improved compared to our other instruments. Accurate kVp measurements can be made for a wider range of x-ray intensity with less dependancy on distance from the x-ray head. The UXI is connected via a 14 foot (4.3 meter) cable to the tablet. Applications include verification of peak x-ray voltage, constancy checks, calibration of x-rays, and quality assurance measurement of exposure time. The unit is also used for half value layer determination, troubleshooting and repair of x-rays, and quality control. All units come with a Certificate of Calibration. Yearly calibration is suggested. The introduction of the UXI allows service personnel to carry one instrument rather than a Dose Meter, mAs Meter and a kVp Meter. New Improved Instrument In addition to combining several proven instruments into one device, significant improvements have been made in the circuitry to improve accuracy, ease of use and range. There is a graphing capability that shows the x-ray waveform for each exposure. New Software Operating System Improvements have been made in both the internal microcomputer program in the UXI front end and in the tablet to facilitate faster measurements and fewer x-ray exposures. There is no minimum exposure time requirement for mA / mAs measurement. The mA and mAs measurements are more accurate because we are measuring the current for the entire x-ray exposure.The minimum exposure time needed for kVp measurements has been reduced to 16 ms. This allows more flexibility when the x-ray is set up based on mAs rather than exposure time. This new feature virtually eliminates sources of error when certain techniques result in short exposure times. The shorter exposure times also give you less wear and tear on x-ray equipment as well as less x-ray exposure to test personnel. This instrument is capable of measuring dose, kVp, mA, mAs and exposure time in one x-ray exposure. The HVL measurement requires three exposures, two with different thicknesses of Aluminum filtration. The program in the Android tablet can be upgraded as new features are added by connecting to internet. Users will be notified by email when upgrades are available. Features • Combines several instruments • kVp • mA and mAs • dose • x-ray detector and oscilloscope • Easy to use • No need to set for AC / DC • Self-resetting • mA is stored permitting short exposures • Measures kVp, mA, mAs, dose and exposure time simultaneously • kVp is noninvasive • AC and DC x-rays • High accuracy • Battery operated • Two year warranty • Compact size • Durable ABS plastic case • Custom carrying case Typical Applications • • • • • • • • Measurement of exposure Verification of peak x-ray voltage Constancy checks X-ray calibration Quality assurance Measurement of X-ray exposure time Half Value Layer determination Troubleshooting and repair of X-rays Typical Tablet Display Graph Function, 300 ms, half-wave x-ray Carrying Case All UXI units come with a custom Carrying Case, that keeps your instrument and tablet safe and has room for cables and accessories. Specifications for UXI / UXI-L kVp RANGE • UXI: 45 to 125 kV • UXI-L: 40 to 120 kV KVP ACCURACY • 2% +/-1 kV, at 25 to 100 mA for UXI • 2% +/-1 kV, at 10 to 50 mA for UXI-L • 18 to 42 cm from head, for Tungsten target x-ray tube with 1.5 mm Al equivalent filtration EXPOSURE TIME ACCURACY • 1% 2 millisecond (1/5 to 2 sec) • Minimum exposure time is 16 milliseconds MINIMUM EXPOSURE TIME • kVp Measurement • 16 millisec - Short Delay • 40 millisec - Long Delay • Exposure Time Measurement Only • 2 millisec MINIMUM CURRENT (mA) • 7 mA at 50 kV, 10 cm from x-ray source UXI • 5 mA at 50 kV, UXI-L • Also depends on focus / collimating HVL mA / mAs Specifications for 820 RANGE General Specifications DISPLAY • 7 inch (177.8 mm) Tablet CONTROLS / INDICATORS • 200 mA Full Scale • 0.1 mA Resolution (mA or mAs) • 7 inch Nexus II Tablet Display • 10 Ohms Input Impedance • 14 foot (4 meter) USB Cable • 2A Full Scale • Remote Operation via USB • 1 mA Resolution (mA or mAs) • 1 Ohm Input Impedance POWER • Meter automatically selects range ACCURACY • 2% 1 mA on both ranges CONNECTION • Via 5 meter cable with two alligator clips • Tablet battery powers UXI X-ray Detector • via USB Cable BATTERY LIFE • Battery life with tablet is 3 hours of continuous use • Unit comes with AC Charger PHYSICAL SIZE / WEIGHT • UXI X-ray Detector • 150 x 120 x 58.5 mm (5.9 x 4.7 x 2.3") • 500g (0.5 lb) Manufactured by ECC, distributed by: X-2 Engineering Galen J Hiveley x2engineering@msn.com (Email) www.xraypartsdepot.com (Website) X-2 Engineering 2931 West 34th St Unit D Davenport, Iowa 52806 563-320-3458 phone 563-386-1094 fax