Remote Temperature Controllers Quick Selection Guide A Complete Selection For A Wide Range Of Applications Electronic Standalone Controllers T775 Provide on/off, modulating, or reset control in applications where electronic accuracy in addition to remote sensing is desired. Standard Models •Available with one, two or four SPDT relay output stages and/or modulating outputs (0-10 Vdc, 2-10 Vdc, 4-20 mA and electronic Series 90 selectable). All models have built-in time-clock scheduler for setback. • Typical applications include – On/off control of fans, motors and heaters – Proportional or floating control of damper and valve actuators – Outdoor reset of heating and cooling systems T775 Electronic Remote Temperature Controllers Models for Standard Applications Product Number T775A2009 T775B2016 T775B2032 T775B2024 Description Standard Standard-NEMA 4X Standard Standard-NEMA 4X T775B2040 Standard T775M2006 T775M2022 Modulating Modulating-NEMA 4X Relay Outputs 1 SPDT 2 SPDT 2 SPDT 4 SPDT Replaces T775A1001 T775A1019, T775B1000 T775C1009, T775D1008 T775A1027, T775A1035, T775B1018, T775B1026, T775B1040 Analog Outputs 4-20 mA, 0-10 Vdc, 2-10 Vdc & Series 90 # Sensors Included2 1 1 1 1 2 2 1 2 2 2 2 1 1 2 2 1 2 2 1 2 2 2 2 2 2 1 2 2 2 2 2 4 SPDT None 2 SPDT T775E1015, T775E1023, T775E1056, 2 SPDT T775E1064, T775E1098 T775G1005, T775G1013, T775G1021, T775M2014 Modulating-NEMA 4X 4 SPDT T775G1039 T775M2030 Modulating T775E1114, T775F1022, T775F1055, T775F1089 4 SPDT T775R2035 Reset Option T775J1001, T775J1076 2 SPDT T775R2043 Reset Option T775J1019, T775J1027, T775J1035 None T775R2027 Reset Option T775J1043, T775J1050, T775J1068 2 SPDT T775R2001 Reset Option 4 SPDT T775R2019 Reset Option 4 SPDT 1 One floating output eliminates two relay outputs. 2 50021579-001 included with non-NEMA 4X models, and T775-SENS-WR included with NEMA 4X models. T775M2048 1 1 2 Sensor Inputs Available 1 2 2 2 Floating Output1 Modulating 2 1 2 2 2 2 T775 Special Models T775U — Universal model controls pressure, humidity, temperature or any control medium that inputs 1097 ohms PTC, 0-10 Vdc or 4-20 mA. CO2 sensors are compatible but reading displayed in percent, not ppm. T775P — Special boiler model with features like WWSD, Alarming and control of up to 12 stages from a single setpoint using optional 4-relay expansion modules T775S. T775L — Special sequencing module allows configuration of up to 12 relay outputs with one or two setpoints in any number and combination desired. Do 3 heat/7 cool, 6 heat/2 cool, 4 heat/2 heat — whatever you desire. T775 Electronic Remote Temperature Controllers Product Number T775P20032 T775L2007 T775U2006 2 Description Special boiler with reset Stage sequencer with reset option Universal — humidity, pressure, etc. Replaces Models for Special Applications Analog Outputs 4-20 mA, 0-10 Vdc, Relay 2-10 Vdc, Digital Outputs & Series 90 Output 4 SPDT 1 4 SPDT3 H775A1006, H775A1022, H775A1048, H775A1063, 2 SPDT H775B1005, H775C1004, H775D1003, H775E1002 2 Dedicated Pump Output • Sensor Output Inputs # Sensors 1 Available Included Expandable Reset 3 3 • • 2 1 • • 24 Universal - Control to sensor A T775U2016 (universal input) and sensor B 2 SPDT 2 24 (temp) independently. T775S2008 Relay expansion module 4 SPDT Use with T77P or T775L 1 4 or 8 more relays possible with T775S2008 relay expansion module(s). 2 Includes dedicated pump output, equal run time, pump pre-purge and post-purge, WWSD and more. 3 Up to 2 independent non-sequenced relays are also available. 4 First input configurable for temperature 0-5Vdc, 0-10 Vdc, or 4-20 mA; second input is configurable for temperature only. • • Refrigeration Controllers Freeze stats T4031, T6031 L480, L482 For limit or temperature control in refrigerated areas where remote mounting of sensing element is required. Used to limit or control temperature in air conditioning systems or refrigerated enclosures. •Liquid-filled copper elements provide rapid sensing to control the compressor system. •Control temperature in a duct, tank, freezer or cooler. •Controller element can be directly immersed in the controlled medium. • Adjustable control setpoint. • Ambient temperature compensation provides good temperature control. • Applications include freezer cabinets, display cases, beverage coolers, milk cooling tanks and cooling coils. •Can act as a frost alarm operator in storehouses or orchards where frost would damage crops or equipment. Refrigeration Controllers/Freeze Stats Capillary Length Part Number Setpoint Range Output Feet Meters ˚F ˚C L480B1239 20˚ F to 60˚ F 1 SPDT 20 ft 6.1 m 10˚ F 5.6˚ C L480G1044 20˚ F to 60˚ F 1 SPST 20 ft 6.1 m 15˚ F 8˚ C Manual reset L482A1004 15˚ F to 55˚ F 2 SPST, one N.O., one N.C. 20 ft 6.1 m 5˚ F 2.8˚ C Manual reset T4031A1016 -30˚ F to +50˚ F 1 SPST 5 ft 1.52 m 1.0˚ F 0.6˚ C T4031A1073 -30˚ F to +50˚ F 1 SPST 8 ft 2.44 m 3.5˚ F 1.9˚ C Makes on temp fall T6031A1011 15˚ F to 90˚ F 1 SPDT 5 ft 1.5 m 3.5˚ F to 16˚ F 1.9˚ C to 8.9˚ C Makes on temp fall T6031A1029 -30˚ F to +90˚ F 1 SPDT 8 ft 2.4 m 3.5˚ F to 16˚ F 1.9˚ C to 8.9˚ C SuperTradeline T6031A1052 -30˚ F to +90˚ F 1 SPDT 5 ft 1.5 m 3.5˚ F to 16˚ F 1.9˚ C to 8.9˚ C T6031A1060 -30˚ F to +90˚ F 1 SPDT 20 ft 6.1 m 3.5˚ F to 16˚ F 1.9˚ C to 8.9˚ C T6031A1086 -35˚ C to +30˚ C 1 SPDT 8 ft 2.4 m 3.5˚ F to 16˚ F 1.9˚ C to 8.9˚ C T6031A1136 -30˚ F to +90˚ F 1 SPDT 8 ft 2.4 m 3.5˚ F to 16˚ F 1.9˚ C to 8.9˚ C T4031, T6031 L480, L482 Differential Comments Celsius model Remote Temperature Controllers Setpoint Temperature Differential Capillary Length Part Number ˚F ˚C ˚F ˚C Relay Outputs Element Type Feet Meters T4031C1012 40˚ F to 180˚ F 4˚ C to 82˚ C 5˚ F 2.8˚ C 1 SPST, break on temperature rise Copper bulb 5.5 ft 1.7 m T6031C1009 40˚ F to 180˚ F 4˚ C to 82˚ C 2˚ F 1.1˚ C 1 SPDT Copper bulb 5.5 ft 1.7 m T6031C1058 100˚ F to 240˚ F 38˚ C to 116˚ C 2˚ F 1.1˚ C 1 SPDT Stainless steel bulb 5 ft 1.5 m T6031D1015 40˚ to 180˚ F 4˚ C to 82˚ C 5˚ F 2.8˚ C 1 SPDT Copper bulb 5.5 ft 1.7 m T6031D1031 0˚ F to 70˚ F -18˚ C to +21˚ C 5˚ F 2.8˚ C 1 SPDT Copper bulb 5.5 ft 1.7 m T6031D1049 30˚ F to 270˚ F -1˚ C to 132˚ C 7˚ F 3.9˚ C 1 SPDT Copper bulb 5.5 ft 1.7 m T6031G1000 0˚ F to 90˚ F -18˚ C to +32˚ C 2˚ F 1.1˚ C 1 SPDT Copper bulb 6.25 ft 1.6 m 3 Crop-trol Controllers Generic remote bulb controllers T675F T675, T678 Used to control an oil-burning, portable crop dryer. Regulate temperature of air or liquids in ducts, pipes, tanks and boilers. • Suitable for line-voltage, low-voltage or millivolt (Powerpile) switching. • Mounts directly on dryer with sensing bulb in discharge air duct. • Knob extends through case for manual control point adjustment. • Differential setting wheel, located under cover, adjusts difference between cut-in and cut-out temperatures. • Suitable for applications requiring temperature control of air or liquids where controller must be placed outside the sensing area. •Typical uses include control of dampers and valves in heating, cooling and heating-cooling systems. • Fast response models (available for use in return air duct) operate approximately four times faster than standard models. •Controller can be mounted in any position. • Ambient temperature compensation provides good temperature control. Remote Temperature Controllers 4 Element Type Capillary Length (Feet) Differential (˚F) Comments Stainless steel bulb 20 ft 3˚ F to 10˚ F Stainless Steel Bulb 1 SPDT Copper bulb 20 ft 3˚ F to 10˚ F 1 SPDT Copper bulb 20 ft 1˚ F fixed 1 SPDT Copper bulb 20 ft 3.6˚ F to 12˚ F Part Number Setpoint Temperature Relay Outputs T675A1045 0˚ F to 100˚ F 1 SPDT T675A1102 160˚ F to 260˚ F T675A1136 0˚ F to 100˚ F T675A1425 55˚ F to 175˚ F T675A1458 55˚ F to 175˚ F 1 SPDT Copper bulb 5 ft 1˚ F fixed T675A1508 0˚ F to 100˚ F 1 SPDT Copper bulb 5 ft 3˚ F to 10˚ F Includes 107324A Duct Bulb Holder T675A1516 0˚ F to 100˚ F 1 SPDT Copper bulb 5 ft 1˚ F fixed Includes 107324A Duct Bulb Holder T675A1524 55˚ F to 175˚ F 1 SPDT Copper bulb 20 ft 1˚ F fixed T675A1532 160˚ F to 260˚ F 1 SPDT Copper bulb 5 ft 3˚ F to 10˚ F Includes 107324A Duct Bulb Holder T675A1540 55˚ F to 175˚ F 1 SPDT Copper bulb 5 ft 3.6˚ F to 12˚ F Includes 107324A Duct Bulb Holder T675A1565 0˚ F to 100˚ F 1 SPDT Copper bulb 20 ft 3˚ F to 10˚ F Includes 107324A Duct Bulb Holder T675A1706 0˚ F to 100˚ F 1 SPDT Fast response capillary 5 ft 3˚ F to 10˚ F Fast response model, includes 107324A Duct Bulb Holder T675A1722 55˚ F to 175˚ F 1 SPDT Fast response capillary 5 ft 3.6˚ F to 12˚ F Fast response model, includes 107324A Duct Bulb Holder T675A1771 55˚ F to 175˚ F 1 SPDT Fast response capillary 5 ft 1˚ F fixed Fast response model, includes 107324A Duct Bulb Holder T675A1920 -15˚ C to +35˚ C 1 SPDT Copper bulb 20 ft 1.7˚ C to 5.6˚ C Bi-lingual French, Celsius Model T675A2068 -15˚ C to +35˚ C 1 SPDT Copper bulb 1.5 m 1.7˚ C to 5.6˚ C Celsius model T675A2076 -15˚ C to +35˚ C 1 SPDT Copper bulb 1.5 m 0.6˚ C fixed Celsius model T675A2084 -15˚ C to +35˚ C 1 SPDT Copper bulb 6.1 m 1.7˚ C to 5.6˚ C Celsius model T675A2100 15˚ C to 75˚ C 1 SPDT Copper bulb 1.5 m 2˚ C to 6.6˚ C Celsius model T675A2118 75˚ C to 125˚ C 1 SPDT Copper bulb 1.5 m 1.7˚ C to 5.6˚ C Celsius model T675B1002 30˚ F to 50˚ F 1 SPDT Copper bulb 10 ft Manual Reset T675B1010 30˚ F to 50˚ F 1 SPDT Copper bulb 20 ft Manual Reset T675B1028 -20˚ F to +50˚ F 1 SPDT Copper bulb 10 ft Manual Reset T675F1032 80˚ F to 220˚ F 1 SPDT Copper bulb 10 ft 5˚ F to 30˚ F T678A1015 0˚ F to 100˚ F 2 SPDT Copper bulb 20 ft Switch: 3˚ F fixed|/Interstage: 3˚ F to 10˚ F adjustable T678A1155 -15˚ C to +35˚ C 2 SPDT Copper bulb 5 ft 3˚ F Bi-lingual French, Celsius Model T678A1163 5˚ F to 95˚ F 2 SPDT Copper bulb 6.1 m Switch: 1.7˚ C fixed|/Interstage: 1.7˚ C to 5.6˚ C adjustable Celsius model T678A1353 55˚ F to 175˚ F 2 SPDT Copper bulb 5 ft 3.6˚ F Switch: 3.6˚ F fixed|/Interstage: 3.6˚ F to 12˚ F adjustable T678A1361 55˚ F to 175˚ F 2 SPDT Copper bulb 20 ft T678A1395 15˚ C to 75˚ C 2 SPDT Copper bulb 1.5 m 2˚ C T678A1437 0˚ F to 100˚ F 2 SPDT Copper bulb 5 ft Switch: 3˚ F fixed|/Interstage: 3˚ F to 10˚ F adjustable T678A1445 55˚ F to 175˚ F 2 SPDT Copper bulb 5 ft Switch: 3.6˚ F fixed|/Interstage: 3.6˚ F to 12˚ F adjustable T678A1478 0˚ F to 100˚ F 2 SPDT Fast response capillary 5 ft Switch: 3˚ F fixed|/Interstage: 3˚ F to 10˚ F adjustable Fast response model T678A1494 55˚ F to 175˚ F 2 SPDT Fast response capillary 5 ft Switch: 3.6˚ F fixed|/Interstage: 3.6˚ F to 12˚ F adjustable Fast response model T678A1627 0˚ F to 100˚ F 2 SPDT Averaging capillary 10 ft Switch: 3.6˚ F fixed|/Interstage: 3.6˚ F to 12˚ F adjustable Celsius model T678A1692 15˚ C to 7˚5 C 2 SPDT Copper bulb 1.5 m 2˚ C Celsius model T678C1005 55˚ F to 85˚ F 2 SPDT Copper bulb 5.5 ft 5˚ F Changeover Stat T678F1002 55˚ F to 85˚ F 2 SPDT Copper bulb 5.5 ft 2.0˚ F Farm controllers T631 Provide line voltage control of heating, cooling and ventilating systems in farm buildings or storage areas. • Use in barns, poultry houses, hog barns, pump houses, milk houses and crop storage houses. • Treated to resist corrosion. • Slots in front and bottom of case provide maximum air circulation over the coiled sensing element. • SPDT snap switches permanently sealed against corrosion. • Easy mounting using screws through holes in back of case. T631 nema-iv Controller T631F, G Provide line voltage control of heating, cooling and ventilating systems in farm buildings, storage areas and industrial environments; watertight, dust-proof enclosure. • Use in barns, brooder houses, poultry houses, hog barns, pump houses, milk houses, crop storage houses and industrial environments. •NEMA 4X enclosure protects thermostat and wiring connections from oil, water, dust, and corrosion. •Clear plastic cover reveals setpoint, discourages tampering. • Sensing element externally mounted for fast response and tin plated to resist corrosion. •Reliable snap switches sealed against contamination. •Insulated case has internal grounding screw for safety. • Meet National Electrical Code Article 547-4 requirements. • Easy mounting with screws through holes in flanges on case. T631F, G Farm Controllers Part Number Setpoint Temperature Relay Outputs Differential Comments T631A1006 35˚ F to 100˚ F 1 SPDT 2.0˚ F Red Finish T631A1022 70˚ F to 140˚ F 1 SPDT 2.0˚ F Red Finish T631A1030 0˚ F to 70˚ F 1 SPDT 3.0˚ F Red Finish T631A1063 -10˚ F to +100˚ F 1 SPDT 3.0˚ F Red Finish T631A1113 35˚ F to 100˚ F 1 SPDT 3.5˚ F Red Finish T631A1154 0˚ C to 40˚ C 1 SPDT 1.1˚ C Scale in Celsius T631B1005 35˚ F to 100˚ F 2 SPDT (1 hp ) 2.0˚ F Red Finish T631B1054 35˚ F to 100˚ F 2 SPDT (1 hp ) 2.0˚ F Red Finish T631C1012 20˚ F to 90˚ F 1 SPDT 3.0˚ F Gray Finish T631C1020 70˚ F to 140˚ F 1 SPDT 2.0˚ F Gray Finish T631C1038 -10˚ C to +30˚ C 1 SPDT 1.7˚ C Scale in Celsius T631C1046 20˚ C to 60˚ C 1 SPDT 1.1˚ C Scale in Celsius T631C1053 35˚ F to 100˚ F 1 SPDT 2.0˚ F Gray Finish T631C1103 -30˚ F to +100˚ F 1 SPDT 5.0˚ F Gray Finish T631F1068 35˚ F to 100˚ F 1 SPDT 2.0˚ F NEMA 4X Housing T631F1084 35˚ F to 100˚ F 1 SPDT 2.0˚ F NEMA 4X Housing T631F1092 35˚ F to 100˚ F 1 SPDT 2.0˚ F NEMA 4X Housing T631G1059 35˚ F to 100˚ F 2 SPDT (1 hp ) 2.0˚ F NEMA 4X Housing 5 proportional temperature controllers T991 For modulating control of water or air temperature in ducts, tanks and similar applications. • Fast response models (for duct mounting) have coiled sensing element giving at least four times faster response than standard models. • Ambient temperature compensated for the case and tubing. • Sensing element capillary tubing allows remote mounting of sensing element. • Setpoint may be read and adjusted through cover. • Throttling dial inside case adjusts proportional throttling range. T991 Proportional Temperature Controllers Setpoint Temperature Part Number ˚F ˚C Modulating Output T991A1004 0˚ F to 100˚ F -18˚ C to +38˚ C One 135 Ohm Output N/S Copper bulb 5 ft T991A1012 0˚ F to 100˚ F -18˚ C to +38˚ C One 135 Ohm Output N/S Copper bulb Throttling Range ˚F ˚C Comments 1.5 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S 20 ft 6.1 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S T991A1061 160˚ F to 260˚ F 71˚ C to 127˚ C One 135 Ohm Output N/S Copper bulb 5 ft 1.5 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S T991A1079 160˚ F to 260˚ F 71˚ C to 127˚ C One 135 Ohm Output N/S Copper bulb 20 ft 6.1 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S T991A1095 5˚ F to 95˚ F -15˚ C to +35˚ C One 135 Ohm Output N/S Copper bulb 5 ft 1.5 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C Celsius Scale T991A1103 N/S -15˚ C to +35˚ C One 135 Ohm Output N/S Copper bulb 20 ft 6.1 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C Celsius Scale T991A1152 N/S 75˚ C to 125˚ C One 135 Ohm Output N/S Copper bulb 5 ft 1.5 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C Celsius Scale T991A1186 55˚ F to 175˚ F 13˚ C to 79˚ C One 135 Ohm Output N/S Copper bulb 5 ft 1.5 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S T991A1194 55˚ F to 175˚ F 13˚ C to 79˚ C One 135 Ohm Output N/S Copper bulb 20 ft 6.1 m 3.5˚ F to 36˚ F 1.9˚ C to 20˚ C N/S T991A1210 59˚ F to 167˚ F 15˚ C to 75˚ C One 135 Ohm Output N/S Copper bulb 5 ft 1.5 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C Celsius Scale T991A1244 55˚ F to 175˚ F 13˚ C to 79˚ C One 135 Ohm Output N/S Copper bulb 5 ft 1.5 m 3.5˚ F to 36˚ F 1.9˚ C to 20˚ C N/S T991A1269 55˚ F to 175˚ F 13˚ C to 79˚ C One 280 Ohm Output N/S Copper bulb 20 ft 6.1 m 3.5˚ F to 36˚ F 1.9˚ C to 20˚ C 280 ohm T991A1343 55˚ F to 175˚ F 13˚ C to 79˚ C One 280 Ohm Output N/S Copper bulb 5 ft 1.5 m 3.5˚ F to 36˚ F 1.9˚ C to 20˚ C N/S T991A1350 55˚ F to 175˚ F 13˚ C to 79˚ C One 135 Ohm Output N/S Copper averaging element 24 ft 7.3 m 3.5˚ F to 36˚ F 1.9˚ C to 20˚ C N/S T991A1426 0˚ F to 100˚ F -18˚ C to +38˚ C One 135 Ohm Output N/S Copper bulb 5 ft 1.5 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S T991A1715 0˚ F to 100˚ F -18˚ C to +38˚ C One 135 Ohm Output N/S Copper fast response element 5 ft 1.5 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S 13˚ C to 79˚ C One 135 Ohm Output N/S Copper fast response element 5 ft 1.5 m 3.5˚ F to 36˚ F 1.9˚ C to 20˚ C N/S T991A1756 55˚ F to 175˚ F 6 Element Type Capillary Length Feet Meters Relay Outputs T991A1764 0˚ F to 100˚ F -18˚ C to +38˚ C One 135 Ohm Output N/S Copper averaging element 24 ft 7.3 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S T991A2069 0˚ F to 100˚ F -18˚ C to +38˚ C One 135 Ohm Output N/S Copper fast response element 20 ft 6.1 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S T991A2127 0˚ F to 100˚ F N/S One 135 Ohm Output N/S Copper bulb 5 ft 1.5 m 3˚ F to 30˚ F 1.7˚ C to 16.7˚ C N/S Proportional Temperature controllers T915 For ducts, tanks, boilers, pipes and other heat exchangers. • Provide proportioning control of three-wire, low-voltage valve or damper motors. • Used to regulate temperatures of either air or liquids. • All models ambient compensated. • Ambient temperature compensation provides good temperature control. • Temperature setting scale markings in both Fahrenheit and Celsius. • Steel case has a clear plastic cover to make setting readily visible. • Surface mount using two screws through back of case. Proportional Temperature Controllers Part Number T915 Setpoint Temperature ˚F ˚C Modulating Output Capillary Length Relay Outputs Feet Meters ˚F ˚C Comments Differential T915C1407 15˚ F to 90˚ F -10˚ C to +32˚ C One 135 Ohm Output 20 ft 6.1 m 7˚ F to 38˚ F 3.9˚ C to 21.1˚ C N/S T915C1928 80˚ F to 210˚ F 27˚ C to 99˚ C One 135 Ohm Output 5 ft 1.5 m 6˚ F to 32˚ F 3.3˚ C to 17.8˚ C N/S T915C1936 80˚ F to 210˚ F 27˚ C to 99˚ C One 135 Ohm Output 20 ft 6.1 m 6˚ F to 32˚ F 3.3˚ C to 17.8˚ C N/S Electronic remote temperature controllers T7079 Capable of providing on-off temperature control for ducts, tanks, heating and refrigeration units, greenhouses, animal confinement buildings and other applications where electronic accuracy in addition to remote sensing is desired. •Choose from 1 or 2 SPDT relay models. • Two stage models can be configured as 2 heat/2 cool, or 1 heat/1 cool. • Switch selection of heat or cool mode. • Temperature sensing up to 400 feet. • Does not require field calibration. • 10K NTC temperature sensor. • Wide setpoint temperature range. •LED annunciation for both power on and relay state. • Dual setpoint scale (˚F and ˚C). • Models offered with built in isolation transformer for 24 Vac input. • Dual-stage output models can be configured as 2 heat/2 cool, or 1 heat/1 cool. Electronic Remote Temperature Controllers Part Number T7079 Setpoint Temperature ˚F ˚C Differential Relay Outputs Power Input ˚F ˚C T7079A1004 -25˚ F to +105˚ F -32˚ C to +40˚ C 1 SPDT 24 Vac 1˚ F to 30˚ F -17˚ C to +1˚ C T7079A1012 100˚ F to 240˚ F 38˚ C to 116˚ C 1 SPDT 24 Vac 1˚ F to 30˚ F -17˚ C to +1˚ C T7079A1046 -25˚ F to +105˚ F -32˚ C to +40˚ C 1 SPDT 120/240 Vac 1˚ F to 30˚ F -17˚ C to +1˚ C T7079A1053 100˚ F to 240˚ F 38˚ C to 116˚ C 1 SPDT 120/240 Vac 1˚ F to 30˚ F -17˚ C to +1˚ C T7079B1028 -25˚ F to +105˚ F -32˚ C to +40˚ C 2 SPDT 24 Vac 1˚ F to 30˚ F -17˚ C to +1˚ C T7079B1036 100˚ F to 240˚ F 38˚ C to 116˚ C 2 SPDT 24 Vac 1˚ F to 30˚ F -17˚ C to +1˚ C T7079B1044 -25˚ F to +105˚ F -32˚ C to +40˚ C 2 SPDT 120/240 Vac 1˚ F to 30˚ F -17˚ C to +1˚ C T7079B1051 100˚ F to 240˚ F 38˚ C to 116˚ C 2 SPDT 120/240 Vac 1˚ F to 30˚ F -17˚ C to +1˚ C 7 Learn More For more information on Honeywell Remote Temperature Controllers, call 1-800-466-3993 or visit customer.honeywell.com. Automation and Control Solutions In the U.S.: Honeywell 1985 Douglas Drive North Follow us on Twitter: @honeywellcpro Golden Valley, MN 55422-3992 In Canada: YouTube: @honeywellcpro Honeywell Limited 35 Dynamic Drive Toronto, Ontario M1V 4Z9 In Latin America: Honeywell 9315 NW 112th Avenue Miami, FL 33178 customer.honeywell.com 63-9538 PR November 2012 © 2012 Honeywell International Inc.