A3.3.3 6” HORIZONTAL CFL DOWNLIGHT Project: LENSED APERTURE Two 26W Quad CH6-226Q-650CL, -650FL, -650PL Fixture Type: Location: Contact/Phone: TV-H6 PRODUCT SPECIFICATIONS DIMENSIONS Lamp Two 26W quad compact fluorescent lamps CFQ26W/ G24q-3 • 4 pin electronic. 11 3/4" Socket Housing Die-formed galvanized steel housing. Ballast 120V thru 277V HPF Electronic with lamp end-of-life protection • 347V HPF Electronic available in Canada • Optional Dimming Ballast available • U.L. listed/CSA certified. 12 1/2" Reflector .050” aluminum reflector with clear Alzak ® finish. Lens Clear Plastic, Fresnel Glass or Prismatic Glass lens. Trim White Baked enamel on aluminum cone • Integral trim ring • Two torsion springs fasten trim to reflector for easy relamping. 5 1/4" Labels U.L. listed for through branch wiring and wet locations • Union made • CSA certified. 6" Testing All reports are based on published industry procedures; field performance may differ from laboratory performance. 7 1/4" Product specifications subject to change without notice. 6 7/8” CEILING CUTOUT INSTALLATION ENGINEERING DATA Mounting Bracket Rough-in section equipped with vertically adjustable mounting brackets (up to 3”) that accept 1⁄2˝ conduit or “C” channels (HB-26 or HB-50), linear flat bars (LB-27) or Patented (US Patent D552,969) Real Nail® 3 bar hangers (HB-1). Junction Box Pre-wired junction box provided with (5)1⁄2˝ and (1)3⁄4˝ knockouts, U.L. listed/CSA certified for through branch wiring, maximum 8 No. 12 AWG 90° C branch circuit conductors (4 in, 4 out) • Junction box provided with removable access plates • Knockouts equipped with pryout slots. Mounting Frame 16-gauge galvanized steel mounting ring with factory installed reflector mounting clips • Rough-in section (junction box, mounting frame and socket assembly) fully assembled for ease of installation • Accommodates 7⁄8˝ ceiling thickness maximum. Total input power Operating AMPS Power Factor T.H.D. Min. starting temperature Crest Factor Ballast Factor 120V-HPF 50W .41A >.98 <10% -5°F/ -20°C <1.5 1.0 277V-HPF 50W .18A >.98 <10% -5°F/ -20°C <1.5 1.0 347V-HPF Canada 43W .13A >.98 <10% 14°F/ -10°C <1.45 .90 ACCESSORIES Catalog No. HB-26 HB-50 HB-1 LB-27 PLK-E Description Two 26˝ C-channel bar hangers Two 50˝ C-channel bar hangers Two 13½" - 25" adjustable Real Nail® 3 bar hangers Two 27˝ linear bar hangers 13-42W emerg. power kit (Elect. Ballast) To order, specify catalog number. PRODUCT CODES OPTIONS Catalog Number Lens/Trim Finish Ballast Wattage and Lamp CH6-226Q-650CL-WH CH6-226Q-650FL-WH CH6-226Q-650PL-WH Clear Plastic/White Fresnel/White Prismatic/White HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. HPF 120V - 277V, Elect. Two 26W Quad CFL Two 26W Quad CFL Two 26W Quad CFL REV-5/15 (Add as suffix to housing or trim) Catalog No. 347 DB120 DB277 Description 347V, HPF Electronic Ballast 120V Dimming Ballast 277V Dimming Ballast Ordering Example: CH6-226Q-347-650PL-WH A3.3.3 6” HORIZONTAL CFL DOWNLIGHT PHOTOMETRIC REPORT Test Report #: PT08993102 Catalog No: CH6-226Q-650PL-WH Total Luminaire Efficiency: 33.50% Luminaire Spacing Criterion: 1.0 Luminaire: Recessed Downlight with Prismatic Diffuser Lamps: Two 26W Quad Tube CFL lamp rated @1800 lumens each/3600 total lumens LENSED APERTURE Two 26W Quad CH6-226Q-650CL, -650FL, -650PL CANDLEPOWER DISTRIBUTION (Candelas) ZONAL LUMEN SUMMARY Degrees Vertical 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Zone Lumens %Lamp %Fixture Average 779 774 759 733 691 631 542 418 305 229 173 134 107 86 0 0 0 0 0 0 - 30° 567 15.8 47.1 0 - 40° 828 23.0 68.7 0 - 60° 1128 31.3 93.6 0 - 90° 1205 33.5 100.0 90 - 180° 0 0 0 0 - 180° 1205 33.5 100.0 COEFFICIENTS OF UTILIZATION–% (Zonal Cavity Method) Effective Floor Cavity Reflectance 20% (ρfc) ρcc 80 70 50 30 10 0 ρw RCR 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 0 1 2 3 4 5 6 7 8 9 10 40 37 33 30 27 25 23 21 20 18 17 40 36 31 28 25 22 20 19 17 16 15 40 35 30 26 23 21 19 17 15 14 13 39 36 33 29 27 25 23 21 19 18 17 39 35 31 27 25 22 20 19 17 16 15 39 34 29 26 23 20 19 17 15 14 13 38 35 31 29 26 24 22 20 19 18 17 38 34 30 27 24 22 20 18 17 16 15 38 33 29 25 23 20 18 17 15 14 13 36 33 30 28 25 23 22 20 19 17 16 36 33 29 26 24 22 20 18 17 16 14 36 32 28 25 22 20 18 17 15 14 13 35 32 29 27 25 23 21 20 18 17 16 35 32 28 26 23 21 19 18 17 15 14 35 31 28 25 22 20 18 17 15 14 13 34 30 27 24 21 19 17 16 15 14 13 ρcc – Ceiling Cavity Reflectance (%) ρw – Wall Reflectance (%) INITIAL FOOTCANDLES AVERAGE INITIAL FOOTCANDLES One Unit, Two 26 Watt, 74.0° Beam Multiple Units (Square Array) Footcandles Footcandles Beam Beam Edge Beam Center Diameter Distance to Illuminated Plane (Feet) Spacing RCR1 RCR4 RCR8 5.0´ 53 39 29 6.0´ 37 27 20 7.0´ 27 20 15 8.0´ 21 15 11 9.0´ 16 12 9 18 10.0´ 13 10 7 20 12.0´ 9 7 5 5.7 21.6 8.8’ 6 3.2 12.2 11.7’ 8 2.1 7.8 14.6’ 10 1.4 5.4 17.5’ 12 1.0 4.0 20.5’ 14 0.8 3.0 23.4’ 16 0.6 2.4 26.3’ 0.5 1.9 29.2’ Ceiling 80% Wall 50% Floor 20% (Beam Edge defined as 50% of Maximum Nadir Candlepower) 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 220 Chrysler Drive • Brampton, Ontario • Canada L6S 6B6 • Phone (905) 792-7335 • Fax (905) 792-0064 Visit us at www.junolightinggroup.com Printed in U.S.A. ©2016 Acuity Brands Lighting, Inc.