Torque Hinges Damper Hinges -Fixed Torque Type · Torque Adjustable TypeCAD Data QDamper Hinges R Qty.1~19 20~ 0.35 0.7 1.5 3.4 6.9 14.7 15 28 64 32 40 50 36 48 48 18 7.5 21 1.2 4.25 7.5 26 8 32 1.2 4.75 8.5 36 8 32 2 6.5 12 2.1 * Rated torque has a margin of error between +40% and -20%. * Rated torque value is for a single hinge. 1.9 1.7 1.5 1.3 Open-Close Frequencies Days to Ship HHPT7 6 Order Example Part Number HHPR1B QDamper Hinges Q How to select a Torque Hinge. Basically, the lid is operated as shown on right. Calculate necessary torque according to the following formula before selecting a torque hinge that satisfies the specifications. (Assume that the lid's center of gravity lies in the middle.) D P.87 Days 31 J P1 27 60 40 Part Number 10 18.5 3.5 2 Mass (g) No. kg N N · m kgf · cm 6 8-6 8 10 98 0 0 ~ HHPTF HHPTFB (Black Anodize) ** Rated Torque ~ Type * Allowable Load 4.9 50 54 * The allowable load is the value when 2 pieces are used. Order Example Days to Ship 2 -1063 Part Number HHPTF8 6 Days D P.87 S 32 37 42 P1 16 16 21 P2 J € Unit Price 1~8 pcs. S Surface Treatment EN AW-6063/ AlMg0,7Si Anodizing Bushing Polyacetal - Socket Head Cap Screws 1.4567/ X3CrNiCu18-9-4 - Black Anodize Volume € Unit Volume Discount Price Discount 16 13.5 21 13.5 21 8.5 ** Rated torque value is for a single hinge. 9~ 1~8 pcs. Example 9~ Use a hexagon wrench to adjust torque value. EIf tightened with a force of 1.5N-m or more, a hexagon wrench might be damaged. MSDH 71 20 16 20 7.5 71 8 48.5 3 5 7.5 10 Max. Reverse Torque (N-m) Shaft Rotating Direction Selection Max. Usable Torque {N-m} L 0.4 or less R 0.8 or less 1.0 or less (Counterclockwise) 0.6 or less (Clockwise) € Unit Price Torque Maximum Open Angle Direction of Torque Open-Close Lid Damper Maximum Open Angle M Material Body Case (Zinc Die Cast) Hinge (1.4301/X5CrNi18-10) Damper S Surface Treatment Silver Painted - Mass (g) 120 -5~50 410 Days to Ship 8 Days 2,00 EUR/ piece Stopper Operating Temp. Range (°C) Part Number - Shaft Rotating Direction MSDH3 L Express A Direction of Torque Open-Close Lid Max. Useable Angle Order Example Price R Type (Direction of Torque: Clockwise) 90° Torque 120° D P.88 <Basic Principle> The rotation of the vanes compresses the oil and generates control (brake) force to act against work force. EPlease request a quotation for orders of 3 or more identical pieces. Body Case QVolume Discount (ERound down to one Cent.) P.87 Qty. 1~9 10~14 15~19 20~29 Rate € Unit Price 5% 10% 18% EFor orders larger than indicated quantity, please request a quotation. QTable of Selection Guide m (Mass) Part Number M Material Main Body Clear Anodize 21 31 Body Case 8-Ø6.6 Stopper Type 18 7.5 20 16 20 The step of mounting surface is -0.1~+0.3mm. 43 60 80 Part Name 3 71 20 16 20 7.5 71 R13 4− 6.5 11Counterbored P2 48.5 21 86 59 S Bracket D P.87 L Type (Direction of Torque: Counterclockwise) 76.5 HHPTF HHPTFB Lid Damper Side MSDH m(Lid Weight) Bracket mounting position can be adjusted. The lid is removable. Lid 6 Days Days to Ship (Example) When L=0.3m and m=2kg, Max. Torque T=0.3/2x2x9.8=2.94N m. Select two pieces of HHPT15 QAdjustable Torque Type Torque can be easily adjusted with a flat-blade screwdriver. Damper Side L [Formula] Max. Torque T=L/2xm(Weight: kg)x9.8(Newton: N) M Material: Polybutylenterephthalat * Reverse Torque value is for a single damper hinge. Data above are not guaranteed values but reference values of HHPT. Open-Close intervals: 5 times /min. (Single open-close operation=0° 160°) * Considering torque deteriorations caused by aging, temperature and humidity variation, the torque value is set higher than the rated torque value at shipping. Part Number Order Example 20,000 times (LowTorque Range) End Point Example QHow to adjust torque. QBracket Position Change Operating Volume Max. Part Number Reverse € Unit Price Discount Temp. Torque Operating Range Type No. (N-m) * Qty.1~19 20~ Angle (°C) 1A 1B 110 0~40 46 HHPR 2A 0.49~1.27 2B Ambient Temp.(20±15˚C),Operating Humidity Range: 90%RH or Low Reference: Torque variations 2B Starting Point 60° 0° E 110° End Point 15 Or 2A 12 T 10 18 r's pe n m tio Da irec D 27 S 60° (LowTorque Range) End Point 1A 3 14 J 15 Da Di mp re er ct 's ion Starting Point 110° 0° P kgf · cm 60° (LowTorque Range) Mass (g) 3 7 15 W € Unit Price 18 Da Di mp re er ct 's ion 1B 12 HHPT N·m (LowTorque Range) 22 3 No. Mass L (g) 60° End Point 18 Starting Point 110° Example Torque(N-m) Type Rated Torque* Starting Point Combination Examples 36 22 3 14 E T Part Number 110° 2B 36 22 18 r's pe n m tio Da irec D 2A 36 22 10 Volume Discount 1B 36 25 50 78.5 L P 7 4-R3 R 1A Operating Temp. Range: -10°C~50°C Operating Humidity Range: 90%RH or Low Caution - Use 2 hinges. - Align the axes of the two hinges. - Do not use the hinges outdoors or in any places where oil or grease adheres to the hinges. - Do not use the hinges in any places requiring continuous open-close movements. - Vertical use is not assumed given product characteristics. For vertical use, adjust allowable load and torque value to the actual operating conditions. Part Name MMaterial (1) Vane 1.4301/X5CrNi18-10 (2) Resin Barrel Polyacetal (3) Shaft 1.4305/X10CrNiS18-9 (4) Plate 1.4301/X5CrNi18-10 (5) Swage Pin 1.4567/X3CrNiCu18-9-4 4-Ø4.3 20 16 20 W S J (5) HHPR (2) 8 (4) (3) (1) 7.5 HHPT 3 QFixed Torque Type CAD Data L (Dimension of Lid) m 0.2 0.25 0.3 0.32 0.34 0.36 0.38 0.4 0.42 0.44 0.46 0.48 0.5 0.52 0.54 0.56 0.58 0.6 0.5 0.6 0.7 0.8 0.9 1.0 MSDH3 Area 1.2 1.4 1.6 MSDH5 Area 1.8 2.0 MSDH7.5 Area 3.0 MSDH10 Area 4.0 5.0 6.0 7.0 How to Use the Table:Select a damper in the intersecting area of the vertical axis 8.0 (mass of lid: m) and the horizontal axis (dimension of lid in rotating direction: L). 9.0 10.0 Selection Example:When m = 2kg and L = 0.35m, the damper in the intersection of 11.0 the vertical axis of 2kg and the horizontal axis of 0.35m is MSDH5. 12.0 As the inertia moment of the lid, friction at axis and other conditions are ignored, 13.0 selection provided by the table should be considered as references only. 14.0 15.0 QHow to select a damper hinge. kg L Silicon Oil Vanes The lid in a horizontal position generates maximum torque as shown on left. Calculate maximum torque according to the following formula before selecting a damper that satisfies the specifications. m(Lid Weight) [Formula] Max. Torque T=L/2xm(Weight: kg)x9.8(Newton: N) Example) When L=0.4m and m=5kg, Max. Torque T=0.4/2x5x9.8=9.8N-m. Select MSDH10 Note) The selection made by the calculation above is for reference only. The friction resistance and the effect of inertia moment at the hinge were not taken into consideration in the example above. The viscosity of the oil in the damper changes depending on the temperature of the operating environment. Generally, the damping characteristic decreases with rising temperature, whereas it increases with lowering temperature. 2 -1064